Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tracking system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Fragmentation of 200 and 244 MEV/u Carbon Beams in Thick Tissue-Like Absorbers

Stacks consisting of thin CR-39 sheets sandwiched between thick lucite and water absorbers were perpendicularly bombarded by C-12 ions at 200 and 244 MeV/u. Track radius distributions representing the charge composition of the fragmented beams were automatically measured by a particle track analysis system. After analysis of the nuclear charge distributions, the total charge removal cross-sections and elemental production cross-sections of fragments with atomic numbers from 5 to 3, were obtained down to the lower energies (approx. 50 and 100 MeV/u, respectively). It has been found that the measured total charge removal cross-section agrees with theoretical predictions within approx. 10% and very well with previous experiments in corresponding energy regions. Two model calculations for production of B fragment are in good agreement with our measured data while a third model overestimates it by approx. 12%. Theoretical cross-sections for Be and Li fragments differ strongly among the different models and from measured values.

Golovchenko, A. N.↗

X-33 Ascent Flight Controller Design by Trajectory Linearization: A Singular Perturbational Approach

The flight control of X-33 poses a challenge to conventional gain-scheduled flight controllers due to its large attitude maneuvers from liftoff to orbit and reentry. In addition, a wide range of uncertainties in vehicle handling qualities and disturbances must be accommodated by the attitude control system. Nonlinear tracking and decoupling control by trajectory linearization can be viewed as the ideal gain-scheduling controller designed at every point on the flight trajectory. Therefore it provides robust stability and performance at all stages of flight without interpolation of controller gains and eliminates costly controller redesigns due to minor airframe alteration or mission reconfiguration. In this paper, a prototype trajectory linearization design for an X-33 ascent flight controller is presented along with 3-DOF and 6-DOF simulation results. It is noted that the 6-DOF results were obtained from the 3-DOF design with only a few hours of tuning, which demonstrates the inherent robustness of the design technique. It is this "plug-and-play" feature that is much needed by NASA for the development, test and routine operations of the RLV'S. Plans for further research are also presented, and refined 6-DOF simulation results will be presented in the final version of the paper.

Zhu, J. Jim↗

Fluorescence Studies of Protein Crystal Nucleation

One of the most powerful and versatile methods for studying molecules in solution is fluorescence. Crystallization typically takes place in a concentrated solution environment, whereas fluorescence typically has an upper concentration limit of approximately 1 x 10(exp -5)M, thus intrinsic fluorescence cannot be employed, but a fluorescent probe must be added to a sub population of the molecules. However the fluorescent species cannot interfere with the self-assembly process. This can be achieved with macromolecules, where fluorescent probes can be covalently attached to a sub population of molecules that are subsequently used to track the system as a whole. We are using fluorescence resonance energy transfer (FRET) to study the initial solution phase self-assembly process of tetragonal lysozyme crystal nucleation, using covalent fluorescent derivatives which crystallize in the characteristic P432121 space group. FRET studies are being carried out between cascade blue (CB-lys, donor, Ex 376 nm, Em 420 nm) and lucifer yellow (LY-lys, acceptor, Ex 425 nm, Em 520 nm) asp101 derivatives. The estimated R0 for this probe pair, the distance where 50% of the donor energy is transferred to the acceptor, is approximately 1.2 nm, compared to 2.2 nm between the side chain carboxyls of adjacent asp101's in the crystalline 43 helix. The short CB-lys lifetime (approximately 5 ns), coupled with the large average distances between the molecules ((sup 3) 50 nm) in solution, ensure that any energy transfer observed is not due to random diffusive interactions. Addition of LY-lys to CB-lys results in the appearance of a second, shorter lifetime (approximately 0.2 ns). Results from these and other ongoing studies will be discussed in conjunction with a model for how tetragonal lysozyme crystals nucleate and grow, and the relevance of that model to microgravity protein crystal growth

Pusey, Marc L.↗

A Low Cost GPS System for Real-Time Tracking of Sounding Rockets

In an effort to minimize the need for costly, complex, tracking radars, the German Space Operations Center has set up a research project for GPS based tracking of sounding rockets. As part of this project, a GPS receiver based on commercial technology for terrestrial applications has been modified to allow its use under the highly dynamical conditions of a sounding rocket flight. In addition, new antenna concepts are studied as an alternative to proven but costly wrap-around antennas.

Markgraf, M.↗

A Daytime Aspect Camera for Balloon Altitudes

We have designed, built, and flight-tested a new star camera for daytime guiding of pointed balloon-borne experiments at altitudes around 40km. The camera and lens are commercially available, off-the-shelf components, but require a custom-built baffle to reduce stray light, especially near the sunlit limb of the balloon. This new camera, which operates in the 600-1000 nm region of the spectrum, successfully provided daytime aspect information of approximately 10 arcsecond resolution for two distinct star fields near the galactic plane. The detected scattered-light backgrounds show good agreement with the Air Force MODTRAN models, but the daytime stellar magnitude limit was lower than expected due to dispersion of red light by the lens. Replacing the commercial lens with a custom-built lens should allow the system to track stars in any arbitrary area of the sky during the daytime.

Dietz, Kurt L.↗

X-33 Ascent Flight Controller Design by Trajectory Linearization: A Singular Perturbational Approach

The flight control of X-33 poses a challenge to conventional gain-scheduled flight controllers due to its large attitude maneuvers from liftoff to orbit and reentry. In addition, a wide range of uncertainties in vehicle handling qualities and disturbances must be accommodated by the attitude control system. Nonlinear tracking and decoupling control by trajectory linearization can be viewed as the ideal gain-scheduling controller designed at every point on the flight trajectory. Therefore it provides robust stability and performance at all stages of flight without interpolation of controller gains, and eliminates costly controller redesigns due to minor airframe alteration or mission reconfiguration. A prototype trajectory linearization design for X-33 ascent flight controller was designed and tested with 3-DOF and 6-DOF simulations during the 10 weeks SFFP. It is noted that the 6-DOF results were obtained from the 3-DOF design with only a few hours of tuning, which demonstrates the inherent robustness of the design technique. It is this "plug-and-play" feature that is much needed by NASA for the development, test and routine operations of the RLVs. Plans for further research are also presented.

Zhu, J. Jim↗

Orbit Determination Support for the Microwave Anisotropy Probe (MAP)

The Microwave Anisotropy Probe (MAP) is a Medium Class Explorers (MIDEX) mission produced in partnership between Goddard Space Flight Center (GSFC) and Princeton University. The main science objective of the MAP mission is to produce an accurate full-sky map of the cosmic microwave background temperature fluctuations anisotropy. MAP was launched from the Cape Canaveral Air Force Station Complex 17 aboard a Delta II 7425-10 expendable launch vehicle at exactly 19:46:46.183 UTC on June 30, 2001. The spacecraft received a nominal direct insertion by the Delta into a 185 km circular orbit. MAP was then maneuvered into a sequence of phasing loops designed to set up a lunar swingby (gravity-assisted acceleration) of the spacecraft onto a transfer trajectory to a Lissajous orbit about the Earth-Sun L2 point. The mission duration is approximately 27 months with 3 to 4 months of transfer time to the final mission orbit about L2. The MAP transfer orbit consisted of 3.5 phasing loops: the first loop has a 7-day period, the second and third loops have a 9-day period, and the last half loop has a 4-day period as illustrated in Figure 1, which also indicates the placement of maneuvers. A Pfinal correction maneuver was performed 18 hours after the last perigee to more closely achieve the targeted lissajous orbit. The lunar encounter or swingby took place approximately 30 days after launch. After the lunar encounter, the spacecraft will cruise for approximately 120 days before it arrives at L2. A Mid-Course Correction (MCC) maneuver was executed seven days after the swingby to further refine the trajectory. Once the MAP satellite is injected into the L2 Lissajous orbit, it will perform occasional stationkeeping maneuvers to maintain the Lissajous orbit for a minimum of two years (and a goal of four years). Because of its complex orbital characteristics, the mission provided a unique challenge to orbit determination (OD) support in many orbital regimes. Extensive trajectory error covariance analysis was performed to predict ephemeris accuracy for the OD process using a Bayesian least-squares technique. The orbit determination error analysis is essential for maneuver planning and maneuver recovery study. Several tracking scenarios were investigated for each phase of the mission. This paper provides a summary of the premission trajectory covariance error analysis, as well as actual real-time OD results. The use and impact of the various tracking stations, systems, and measurements will be discussed. Details of the operational OD support and the inferred OD accuracy will be presented, and the results will be compared to the premission covariance analysis, In addition, there will be a discussion of the challenges presented to OD support including delta-Vs at apogee as well as perigee, and effects due to spacecraft attitude mode, in light of their implications to the OD accuracy and covariance analysis.

Truong, Son H.↗

Daytime Aspect Camera for Balloon Altitudes

We have designed, built, and flight-tested a new star camera for daytime guiding of pointed balloon-borne experiments at altitudes around 40 km. The camera and lens are commercially available, off-the-shelf components, but require a custom-built baffle to reduce stray light, especially near the sunlit limb of the balloon. This new camera, which operates in the 600- to 1000-nm region of the spectrum, successfully provides daytime aspect information of approx. 10 arcsec resolution for two distinct star fields near the galactic plane. The detected scattered-light backgrounds show good agreement with the Air Force MODTRAN models used to design the camera, but the daytime stellar magnitude limit was lower than expected due to longitudinal chromatic aberration in the lens. Replacing the commercial lens with a custom-built lens should allow the system to track stars in any arbitrary area of the sky during the daytime.

Dietz, Kurt L.↗

The Livingstone Model of a Main Propulsion System

Livingstone is a discrete, propositional logic-based inference engine that has been used for diagnosis of physical systems. We present a component-based model of a Main Propulsion System (MPS) and say how it is used with Livingstone (L2) in order to implement a diagnostic system for integrated vehicle health management (IVHM) for the Propulsion IVHM Technology Experiment (PITEX). We start by discussing the process of conceptualizing such a model. We describe graphical tools that facilitated the generation of the model. The model is composed of components (which map onto physical components), connections between components and constraints. A component is specified by variables, with a set of discrete, qualitative values for each variable in its local nominal and failure modes. For each mode, the model specifies the component's behavior and transitions. We describe the MPS components' nominal and fault modes and associated Livingstone variables and data structures. Given this model, and observed external commands and observations from the system, Livingstone tracks the state of the MPS over discrete time-steps by choosing trajectories that are consistent with observations. We briefly discuss how the compiled model fits into the overall PITEX architecture. Finally we summarize our modeling experience, discuss advantages and disadvantages of our approach, and suggest enhancements to the modeling process.

Bajwa, Anupa↗

Orbit Determination Support for the Microwave Anisotropy Probe (MAP)

NASA's Microwave Anisotropy Probe (MAP) was launched from the Cape Canaveral Air Force Station Complex 17 aboard a Delta II 7425-10 expendable launch vehicle on June 30, 2001. The spacecraft received a nominal direct insertion by the Delta expendable launch vehicle into a 185-km circular orbit with a 28.7deg inclination. MAP was then maneuvered into a sequence of phasing loops designed to set up a lunar swingby (gravity-assisted acceleration) of the spacecraft onto a transfer trajectory to a lissajous orbit about the Earth-Sun L2 Lagrange point, about 1.5 million km from Earth. Because of its complex orbital characteristics, the mission provided a unique challenge for orbit determination (OD) support in many orbital regimes. This paper summarizes the premission trajectory covariance error analysis, as well as actual OD results. The use and impact of the various tracking stations, systems, and measurements will be also discussed. Important lessons learned from the MAP OD support team will be presented. There will be a discussion of the challenges presented to OD support including the effects of delta-Vs at apogee as well as perigee, and the impact of the spacecraft attitude mode on the OD accuracy and covariance analysis.

Bauer, Frank↗

Evaluation of the Space Shuttle Transatlantic Abort Landing Atmospheric Sounding System

A study was conducted to determine the quality of thermodynamic and wind data measured by or derived from the Transatlantic Abort Landing (TAL) Atmospheric Sounding System (TASS). The system has Global Positioning System (GPS) tracking capability and includes a helium-filled latex balloon that carries an instrument package (sonde) and various ground equipment that receives and processes the data from the sonde. TASS is used to provide vertical profiles of thermodynamic and low-resolution wind data in support of Shuttle abort landing operations at TAL sites. TASS uses GPS to determine height, wind speed, and wind direction. The TASS sonde has sensors that directly measure air temperature and relative humidity. These are then used to derive air pressure and density. Test flights were conducted where a TASS sonde and a reference sonde were attached to the same balloon and the two profiles were compared. The objective of the testing was to determine if TASS thermodynamic and wind data met Space Shuttle Program (SSP) accuracy requirements outlined in the Space Shuttle Launch and Landing Program Requirements Document (PRD).

Leahy, Frank B.↗

Fragmentation of 200 and 244 MeV/u Carbon Beams in Thick Tissue-Like Absorbers

Stacks consisting of thin CR-39 sheets sandwiched between thick Lucite and water absorbers were perpendicularly bombarded by C-12 ions at 200 and 244 MeV/u. Track radius distributions representing the charge composition of the fragmented beams were automatically measured by a particle track analysis system. After analysis of the nuclear charge distributions, the total charge removal cross sections and elemental production cross sections of fragments with atomic numbers from 5 to 3, were obtained down to the lower energies (approximately 50 and 100 MeV/u, respectively). It has been found that the measured total charge removal cross section agrees with theoretical predictions within approximately 10% and very well with previous experiments in corresponding energy regions. Two model calculations for production of B fragment are in good agreement with our measured data while a third model overestimates it by approximately 12%. Theoretical cross sections for Be and Li fragments differ strongly among the different models and from measured values.

Golovchenko, A. N.↗

External merology truss technology demonstration (KITE)

To achieve micro-arcsecond astrometry, SIM's external metrology system must track the relative changes of three baseline vectors with a precision of tens of picometers over a one-hour time scale.

metrology interferometry corner cube truss picomet↗

Generalized Orbital Projections of a Sublimating Ice Particle

The issue of orbital debris resulting from human activities in space is a growing concern for the space users' community. Waste generated in Low Earth Orbit (LEO) can stay in orbit for a long time, creating significant hazards for other spacecraft flying at lower intercepting orbits. Many spacecraft, especially crewed vehicles, are required to vent fluids into space. These fluids include propellant, wastewater, excess condensate, and others. It is important to analyze the behavior of particles that result from these activities, since each individual particle is capable of damaging or destroying a spacecraft in a lower, crossing orbit, and such particles are invisible to tracking radar systems on the ground. The deorbit trajectory of an ice particle is complex. It depends on factors including attitude of the vehicle during vent, initial velocities of particles, altitude at which the vent occurred, and numerous evaporation and sublimation factors. These include contamination within the vented water, evolution of bubbles within the clear water, and sun flux factors such as time of the year and current beta angle. The purpose of this study is to examine the influences of these factors on the trajectories of ice particles resulting from condensate water dumps, and to bound the safe trajectories of spacecraft that lie below the venting spacecraft.

Menkin, Evgeny↗

Target-Tracking Camera for a Metrology System

An analog electronic camera that is part of a metrology system measures the varying direction to a light-emitting diode that serves as a bright point target. In the original application for which the camera was developed, the metrological system is used to determine the varying relative positions of radiating elements of an airborne synthetic aperture-radar (SAR) antenna as the airplane flexes during flight; precise knowledge of the relative positions as a function of time is needed for processing SAR readings. It has been common metrology system practice to measure the varying direction to a bright target by use of an electronic camera of the charge-coupled-device or active-pixel-sensor type. A major disadvantage of this practice arises from the necessity of reading out and digitizing the outputs from a large number of pixels and processing the resulting digital values in a computer to determine the centroid of a target: Because of the time taken by the readout, digitization, and computation, the update rate is limited to tens of hertz. In contrast, the analog nature of the present camera makes it possible to achieve an update rate of hundreds of hertz, and no computer is needed to determine the centroid. The camera is based on a position-sensitive detector (PSD), which is a rectangular photodiode with output contacts at opposite ends. PSDs are usually used in triangulation for measuring small distances. PSDs are manufactured in both one- and two-dimensional versions. Because it is very difficult to calibrate two-dimensional PSDs accurately, the focal-plane sensors used in this camera are two orthogonally mounted one-dimensional PSDs.

Liebe, Carl↗

Heterodyne Interferometer Angle Metrology

A compact, high-resolution angle measurement instrument has been developed that is based on a heterodyne interferometer. The common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer setup, an optical mask is used to sample the measurement laser beam reflecting back from a target surface. Angular rotations, around two orthogonal axes in a plane perpendicular to the measurement- beam propagation direction, are determined simultaneously from the relative displacement measurement of the target surface. The device is used in a tracking telescope system where pitch and yaw measurements of a flat mirror were simultaneously performed with a sensitivity of 0.1 nrad, per second, and a measuring range of 0.15 mrad at a working distance of an order of a meter. The nonlinearity of the device is also measured less than one percent over the measurement range.

Hahn, Inseob↗