Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tanks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Characterization of the tank 51 alternate reductant sludge batch 9 slurry sample (HTF-51-15-130)

Tank 51 slurry sample HTF-51-15-130 was collected following sludge washing at the Tank Farm. The sample was received at SRNL and then characterized in preparation for qualification of the alternate reductant Sludge Batch 9 (SB9) flowsheet. In this characterization, densities, solids distribution, elemental constituents, anionic constituents, carbon content, and select radioisotopes were quantified.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impacts of glycolate and formate radiolysis and thermolysis on hydrogen generation rate calculations for the Savannah River Site tank farm

Savannah River Remediation (SRR) personnel requested that the Savannah River National Laboratory (SRNL) evaluate available data and determine its applicability to defining the impact of planned glycolate anion additions to Savannah River Site (SRS) High Level Waste (HLW) on Tank Farm flammability (primarily with regard to H 2 production). Flammability evaluations of formate anion, which is already present in SRS waste, were also needed. This report describes the impacts of glycolate and formate radiolysis and thermolysis on Hydrogen Generation Rate (HGR) calculations for the SRS Tank Farm.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results from the Interim Salt Disposition Program Macrobatch 11 Tank 21H Acceptance Samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of verification of Macrobatch (Salt Batch) 11 for the Interim Salt Disposition Program (ISDP) for processing. This document reports characterization data on the samples of Tank 21H and fulfills the requirements of Deliverable 3 of the Technical Task Request (TTR).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimation of Plutonium-240 Mass in Waste Tanks Using Ultra-Sensitive Detection of Radioactive Xenon Isotopes from Spontaneous Fission

This report details efforts to develop a technique which is able to detect and quantify the mass of 240 Pu in waste storage tanks and other enclosed spaces. If the isotopic ratios of the plutonium contained in the enclosed space is also known, then this technique is capable of estimating the total mass of the plutonium without physical sample retrieval and radiochemical analysis of hazardous material. Results utilizing this technique are reported for a Hanford Site waste tank (TX-118) and a well-characterized plutonium sample in a laboratory environment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Insulation System for Cryogenic Automotive Tanks (iCAT)

The objective of this project was to develop a state-of-the-art Integrated Insulation System for Cryogenic Automotive Tanks (iCAT) using new lightweight, commercially available materials applied with innovative methods that could demonstrate the DOE heat leak targets (< 5-7 W) for a 100 liter (L) cryogenic hydrogen storage tank and require little to no periodic maintenance. The project team focused on developing an integrated system based on a degraded vacuum (from 0.001 torr up to 0.1 torr) environment [Moderate Vacuum], and compared this system to the standard multi-layer insulation (MLI) high vacuum (HV) environment (< 10E-4 torr).

08 HYDROGEN↗

Sensitivity ZAM Modeling Study of Tank 10H VDS Waste Sample (U)

The objective of this work is to study the sensitivity of cesium loading expected on the Tank Closure Cesium Removal (TCCR) columns. Savannah River National Laboratory (SRNL) utilized ZAM, a computer program developed by the research group of Professor Rayford G. Anthony of Texas A&M University, for prediction of cesium loading on the Crystalline Silicotitanate (CST) resin during the processing of Tank 10H Variable Depth Sample (VDS) waste solution.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mercury Dispersion Modeling and Purge Ventilation Stack Height Determination for Tank 41H

The SRNL Atmospheric Technologies Group performed an analysis of mercury emissions from H-Tank Farm – Tank 41H ventilation system exhaust to assess worst case 15-minute and 8-hour average ground level concentrations and evaluate whether the Short-Term Exposure Limit (STEL), or Threshold Limit Value (TLV) levels for mercury will be exceeded during mixing operations. This analysis was also used to establish a minimum stack height at which ambient mercury concentration would not exceed the safety limits. The American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used as the dispersion modelling tool for this analysis. Results indicate that a stack height of 30-ft (for the 25 mg/m 3 emissions case) or 50-ft (for the 50 mg/m 3 emissions case) stacks results in ground level concentrations that do not exceed the STEL or TLV standards.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results from the Interim Salt Disposition Program Macrobatch 11 Tank 21H Acceptance Samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of verification of Macrobatch (Salt Batch) 11 for the Interim Salt Disposition Program (ISDP) for processing. This document reports characterization data on the samples of Tank 21H and fulfills the requirements of Deliverable 3 of the Technical Task Request (TTR).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Sludge Batch 10 Samples from Tank 51H (HTF-51-18-94, -95)

Savannah River National Laboratory characterized sludge samples from Tank 51H that is being used to generate Sludge Batch 10. The composite slurry sample from Tank 51H was analyzed and determined to contain a concentrated salt solution with a sodium concentration of 5.79 M (1.33E+05 mg/L) and insoluble sludge solids content of 7.20 wt% (using all nine replicates from the 3 wt% total solids measurements). Hydroxide is the main anionic species in the salt solution with a concentration of 3.00 M followed by nitrate (0.728 M) and nitrite (0.657 M). The sum of the major cations versus the sum of the major anions from the analysis of the filtered supernatant liquid phase shows a difference of <5% indicating good data quality. The results from the analysis of the digestions of the well mixed composite slurry sample show sodium to be the main component of the total dried solids of the sample followed by aluminum, iron, manganese, and thorium. Additional measurements of the weight percent total solids and density using hand shaking of the sample bottle and recirculation through a peristaltic pump indicate both methods provide adequate mixing of the sludge slurry sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Natural Gas Extraction Condensate Tank Venting and Flaring

This unit process quantifies the amount of gas vented and flared during natural gas production from condensate tanks through flash losses and tank working and breathing losses. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=A56CF16E-36CC-4AEF-90A5-8E548029FD5D

03 NATURAL GAS↗

Natural Gas Extraction Produced Water Tank Venting

This unit process quantifies the amount of gas vented and flared during natural gas production from produced water tanks through flash losses and tank working and breathing losses. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=6D0F3F3B-ECC0-4493-91F7-36F10F381427

03 NATURAL GAS↗

Process Knowledge Concerning Organic Chemicals in Hanford Tank Waste Supernate

This report addresses the specific need to characterize double-shell tank supernates to meet the regulatory requirements and data quality objectives associated with Direct Feed Low Activity Waste, Tank-Side Cesium Removal, Low Activity Waste Pretreatment System, and Test Bed Initiative requirements. The use of process knowledge can greatly reduce the need for chemical analysis to meet regulatory requirements. This will decrease the cost of characterization and improve sample data turnaround times.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Solvent Hold Tank Sample Results for MCU-18-301- 303 (July 2018), MCU-18-357-359-360 (August 2018), and MCU-18-402-410 (September 2018) (Quarterly Report)

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-18-301-302-303, MCU-18- 357-359-360 and MCU-18-402-410 are reported. Most of the conclusions are based on the September SHT sample (MCU-18-402-410). Analyses of the September SHT sample (MCU-18-402-410) indicated that the Modifier (Cs-7SB) and the extractant (MaxCalix) concentrations were below their nominal recommended concentrations (169,000 mg/L and 46,400 mg/L respectively) by 5% and 8% respectively. The suppressor (N,N’,N”–tris(3,7-dimethyloctyl)guanidine or TiDG) concentration has decreased since the April 2018 measurement (Modular Caustic-Side Solvent Extraction Unit or MCU resumed processing radioactive salt solution from May through August 2018) to 241 mg/L, well below the minimum recommended concentration (479 mg/L). The apparent “downwards” trends observed in the TiDG, MaxCalix, and Modifier measurements are consistent with the startup (or Proficiency Runs) of MCU on May 22, 2018; new levels are consistent with the concentrations observed when MCU was fully operational in 2016. This analysis confirms the Isopar™ L addition to the solvent on July 2 and August 9, 2018. This analysis also indicates the solvent did require a trim addition. Based on the current monthly sample, the concentrations of Isopar™ L, MaxCalix, and Modifier are sufficient for continuing operation but are expected to decrease with time. The TiDG concentration was below its recommended level. Periodic characterization and trimming additions to the solvent are recommended. The Semi-Volatile Organic Analysis (SVOA) did not detect any impurities. However, the Fourier Transform Hydrogen Nuclear Magnetic Resonance (FT-HNMR) analysis detected a low concentration of sec-butyl phenol (SBP) at levels of a few ppm. The impurity concentration was highest in the July sample and consistently detected in the August and September samples (but always a few ppm or less). The source of this impurity is due to the degradation of the Modifier. Another impurity observed in the samples was mercury. Based on the September SHT sample, up to 17 ± 3 micrograms of mercury per mL of solvent was detected (the average of the Direct Mercury Analysis (DMA) and X-Ray Fluorescence (XRF) methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 9 and 10 (SB 10 was recently added to Tank 49H in March 2017). The gamma concentration (~2.3E5 dpm/mL) measured in the September SHT samples was consistent with previous values observed when MCU was fully operational (for example, between December 2016 and January 2017) and it was lower than the April SHT measurement. The “dip” in the gamma measurement for the May 2018 SHT sample was due to Isopar™ L addition to MCU during April and May 2018. The laboratory will continue to monitor the quality of the solvent for any new impurities or degradation of the solvent components.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tank 241-AN-107 Study for Semi-Volatile Organics in 2017 Grab Samples and Carbonation of Composite for Solids Precipitation and Caustic Demand

Tank 241-AN-107 waste is known to contain high concentrations of complexing organics, and caustic sodium hydroxide has been added due to depleted free hydroxide in the waste. Eight grab samples were taken in August 2017 for routine chemical analyses. Investigations of the tank’s organic contents and solids precipitation at lower pH levels by CO 2 gas, as well as the performance of caustic demand testing at lower pH ranges were examined. Sub-micron particles were visible, suspended in the supernate, using scanning electron microscopy. Trace amounts of precipitation floating on the surface of the supernate were observed and were collected with the surface liquid samples for investigation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hanford Double Shell Waste Tank Corrosion Studies (Final Report FY2018)

For FY18, Savannah River National Laboratory (SRNL) focused on four main tasks in its study of corrosion of Hanford Double-Shell Tanks (DSTs). The New Limits task focused on the development of a pitting factor as a localized corrosion predictor. Electrochemical experiments were directed towards pitting factors between 1 and 2 (i.e., borderline conditions) and separating the effects of chloride and fluoride in the pitting factor equation. In addition, long term immersion testing experiments with partial and completely immersed coupons in solutions with a wide range of pitting factors were tested. Secondary liner studies continued this year with a new vapor corrosion inhibition (VCI) strategy in which ground water (GW) simulants at a specified concentration of commercial VCI were mixed. The specific concentrations were recommended by Cortec® and was compared with similar concentration of GW with calcium carbonate. The anodic drift task utilized a simulant corresponding to AN-107 waste tank chemistry. The chemistry was studied with three different surface conditions: mill-scale, partial mill-scale and ground to 600 grit to study the impact of different surfaces on the potential drift. The final task was focused on ammonia concentration determination of a vapor space corrosion (VSC) test vessel using Quartz-Enhanced Photoacoustic Spectroscopy (QEPAS) detector. A summary of each task is presented below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Double Shell Waste Tank Corrosion Studies (Final Report FY2019)

During fiscal year (FY) 2019, the Savannah River National Laboratory (SRNL) focused on four primary tasks for Hanford Double Shell Tanks (DSTs) corrosion studies. The first task, New Limits, was a continuation from the electrochemical work started in FY16, to expand electrochemical testing to elevated temperatures and elevated hydroxide concentrations and evaluate how these factors will influence pitting corrosion. Using the pitting factor (PF) equation, these new conditions were validated to provide a conservative estimate for the susceptibility of pitting corrosion on legacy carbon steel. The second task, Secondary Liner Corrosion, focused on Vapor Space Corrosion (VSC) and immersion testing studies using two commercially available vapor corrosion inhibitors (VCIs). For this FY, the VCI strategy was applied mid-experiment to determine performance on weathered coupons. The third task, Long-Term Open Circuit Potential (OCP) Drift, was performed using simplified simulated chemistries to evaluate change in pitting corrosion risk due to evolution of corrosion potential for mill-scale and freshly polished 600-grit surfaces. Finally, the fourth task, Microbiologically-Influenced Corrosion (MIC) studies, was focused on the study of leak detection pit (LDP) water sent from the Hanford tank farm for determination of bacteria that can be conducive to corrosion using commercially available kits: BART TM and MICkit® 5. In addition, this FY, a secondary task was added which was a continuation of the study of the Quartz-enhanced Photoacoustic Spectroscopy (QEPAS) system. Work was started but was ultimately not pursued. A summary of each task performed is presented below.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗