EXPERIMENTAL AND THEORETICAL STUDIES ON THE FORMATION OF DETONATION WAVES IN VARIABLE GEOMETRY TUBES
Formation of detonation waves by oxygen-hydrogen fuel mixture in variable geometry tubes
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Formation of detonation waves by oxygen-hydrogen fuel mixture in variable geometry tubes
I will attempt to determine mathematically the buckling-strength curves of various centrally loaded light-metal tubes which exhibit conspicuous differences of behavior under compressive loads. For this purpose I will employ Von Karman's method, after adapting it to special conditions.
Propanal is an aldehyde intermediate formed during the hydrocarbon combustion process. Potentially, the use of oxygenated biofuels reduces greenhouse gas emissions; however, it also results in increased toxic aldehyde by-products, mainly formaldehyde, acetaldehyde, acrolein, and propanal. These aldehydes are carcinogenic, and therefore it is important to understand their formation and destruction pathways in combustion systems. In this work, ignition delay times were measured behind reflected shock waves for stoichiometric (Φ = 1) mixtures of propanal (CH 3 CH 2 CHO) and oxygen (O 2 ) in argon bath gas at temperatures of 1129 K < T < 1696 K and pressures around 1 and 6 atm. Measurements were conducted using the kinetics shock tube facility at the University of Central Florida. Current results were compared to available data in the literature as well as to the predictions of three propanal combustion kinetic models: Politecnico di Milano (POLIMI), National University of Ireland at Galway, and McGill mechanisms. In addition, a continuous wave-distributed feedback interband cascade laser centered at 3403.4 nm was used for measuring methane (CH 4 ) and propanal time histories behind the reflected shock waves during propanal pyrolysis. Concentration time histories were obtained at temperatures between 1192 and 1388 K near 1 atm. Sensitivity analysis was carried for both ignition delay time and pyrolysis measurements to reveal the important reactions that were crucial to predicting the current experimental results. Adjustments to the POLIMI mechanism were adopted to better match the experimental data. Further research was suggested for the H abstraction reaction rates of propanal. Finally, in addition to extending the temperature and pressure region of literature ignition delay times, we provide the first high-temperature species concentration time histories during propanal pyrolysis.
Shock tube experiments have been carried out on 2–methyl–1–butene (2M1B), 2–methyl–2–butene (2M2B), and 3–methyl–1–butene (3M1B)—the three isomers of methyl butene compound. Here, carbon monoxide (CO) time–histories and ignition delay times are obtained behind reflected shockwaves over the temperature range of 1350–1630 K and pressures of 8.3–10.5 atm with stoichiometric mixtures of 0.075% fuel in O 2 /Ar. Comparative ignition study reveals that 3M1B ignites significantly faster than the other two isomers, while 2M1B dissociates earlier but ignites later than 2M2B. Possible mechanisms for this behavior are discussed with ignition delay time sensitivity and reaction path analysis. In addition, time–resolved CO measurements are compared with three different reaction mechanisms from the literature. Sensitivity analyses have been carried out to identify important reactions that need attention to accurately predict the chemistry of these isomers. Further investigation into the rates of unimolecular fuel decomposition reactions and C 3 H 3 + O 2 = CH 2 CO + HCO reaction are suggested based on the current investigation.
Thin monofilamentary Fe/MgB{sub 2} superconducting wires without barriers are investigated by means of electrical transport measurements and surface and structural analysis methods. Small diameter wires are fabricated by pellet-in-tube method (PeIT) to obtain a high uniform initial filling density and heat treated as a function of various sintering temperatures and times. The results are discussed in terms of the grain connectivity, Fe{sub 2}B phase formation, and the relation between wire diameter and sintering conditions. We suggest that PeIT has a crucial importance to achieve homogeneous initial filling density, which leads to the fabrication of uniform long-length MgB{sub 2} wires.
The ability to predict the behavior of composite structures under impact conditions is an important challenge for engineering analysis since it requires modeling beyond the elasticity and into failure initiation and propagation. Crushing of laminate composites is the result of a combination of several and complex failure mechanisms, which are not always possible to reproduce together in a single finite element analysis (FEA). In this paper, models based on lamina-level failure criteria have been used to predict the onset of damage; once failure initiates, the mechanisms of failure propagation require reducing the material properties using several degradation schemes. Among the composite material models available in LS-DYNA, MAT-ENHANCED-COMPOSITE-DAMAGE (MAT-54) has been chosen for modeling the axial crushing of composite tubes with various resistant sections and wall slope, given the reduced experimental input parameters to insert into the card definition. Comparison with experimental data shows that such material model is able to successfully reproduce the crushing behavior, even if the numerical results are strictly correlated with some model parameters which cannot be measured experimentally or are purely mathematical expedients. Therefore, extensive calibration of these parameters by trial-and-error is necessary to achieve successful simulation results. Once done it for a structure made of the same composite material, it is possible to adopt the same card configuration for all the other cases, obtaining good agreement between numerical and experimental results. After, the attempt to model the same geometries using the MAT-LAMINATED-COMPOSITE-FABRIC (MAT-58) card with the same parameter values previously calibrated has been done obtaining results comparable with the experimental data.
Conventional mammographic image contrast is derived from x-ray absorption, resulting in breast structure visualization due to density gradients that attenuate radiation without distinction between transmitted, scattered, or refracted x-rays. Diffraction-enhanced imaging (DEI) allows for increased contrast with decreased radiation dose compared to conventional mammographic imaging because of monochromatic x-rays, its unique refraction-based contrast mechanism, and excellent scatter rejection. However, a lingering drawback to the clinical translation of DEI has been the requirement for synchrotron radiation. The authors laboratory developed a DEI prototype (DEI-PR) using a readily available tungsten x-ray tube source and traditional DEI crystal optics, providing soft tissue images at 60 keV. Images of full-thickness human breast tissue specimens were acquired on synchrotron-based DEI (DEI-SR), DEI-PR, and digital mammographic systems. A panel of expert radiologists evaluated lesion feature visibility and correlation with pathology after receiving training on the interpretation of refraction contrast mammographic images. For mammographic features (mass, calcification), no significant differences were detected between the DEI-SR and DEI-PR systems. Benign lesions were perceived as better seen by radiologists using the DEI-SR system than the DEI-PR system at the [111] reflectivity, with generalizations limited by small sample size. No significant differences between DEI-SR and DEI-PR were detected for any other lesion type (atypical, cancer) at either crystal reflectivity. Thus, except for benign lesion characterizations, the DEI-PR system's performance was roughly equivalent to that of the traditional DEI system, demonstrating a significant step toward clinical translation of this modality for breast cancer applications.
The ignition of iso-octane/air and iso-octane/O{sub 2}/Ar ({proportional_to}20% O{sub 2}) mixtures was studied in a shock tube at temperatures of 868-1300 K, pressures of 7-58 atm, and equivalence ratios {phi}=1.0, 0.5, and 0.25. Ignition times were determined using endwall OH* emission and sidewall piezoelectric pressure measurements. Measured iso-octane/air ignition times agreed well with the previously published results. Mixtures with argon as the diluent exhibited ignition times 20% shorter, for most conditions, than those with nitrogen as the diluent (iso-octane/air mixtures). The difference in measured ignition times for mixtures containing argon and nitrogen as the diluent gas can be attributed to the differing heat capacities of the two diluent species and the level of induction period heat release prior to ignition. Kinetic model predictions of ignition time from three mechanisms are compared to the experimental data. The mechanisms overpredict the ignition times but accurately capture the influence of diluent gas on iso-octane ignition time, indicating that the mechanisms predict an appropriate amount of induction period heat release. (author)
Ethanol oxidation was studied by measuring CO time-histories and ignition delay times behind reflected shockwaves at elevated pressures. In this study, experimental conditions included a temperature range of 960–1580 K, pressure range of 17.8–23.9 atm, and initial fuel concentrations of 6.54% and 0.25% with nitrogen and argon used as bath gasses, respectively. The equivalence ratio for high fuel loading was kept constant at 1.0, and for low fuel loading equivalence ratios were 1.0 and 0.5. For high fuel loading, early heat/energy release was observed in nearly all ignition delay time measurements, indicative of preignition; however, data collected are in good agreement with model predictions. These events are interpreted as a transition from mild to strong ignition. For the low fuel loading cases (Φ = 1.0 and 0.5), no early heat/energy release was observed. Comparisons of measured CO concentration profiles with the predictions from kinetic mechanisms of Metcalfe et al. (2013), Mittal et al. (2014), and Zhang et al. (2018) were made assuming constant internal energy and volume for the test gas. Such comparisons in addition with performed sensitivity and pathway analyses for CO formation revealed lower temperature sensitivity to the bimolecular reaction of methyl and hydroperoxyl radicals given by CH 3 + HO 2 CH 3 O + OH, and H-atom abstraction by the hydroperoxyl radical at the alpha site on ethanol given by elementary reaction C 2 H 5 OH + HO 2 =sC 2 H 4 OH + H 2 O 2 . Furthermore, the current study provides important validation targets for ethanol chemical kinetic mechanisms and highlights the benefits of time-history measurements at various temperatures and pressures in a shock tube, which are scare in the literature.
The pyrolytic reactions of n-propyl and i-propyl radicals and their precursors have been investigated at elevated temperatures and pressures (600 – 900 K and 5 – 8 bar). The studies were performed in a miniature high repetition rate shock tube with synchrotron vacuum ultraviolet photoionization mass spectrometry yielding comprehensive datasets of temporal and photoionization energy dependencies of reagents and products. The propyl radicals were generated by pyrolysis of alkyl nitrites. In addition to the main decomposition path, NO elimination, the mass spectra allowed an alternative minor path via HNO elimination to be identified and quantified. For the n-propyl precursor the HNO elimination route accounted for 9% of the alkyl nitrite while for the i-propyl precursor it was 2.5%. These values are in good agreement with a recent study on i-butyl radicals in the same apparatus at similar conditions. The ratio of disproportionation/recombination was obtained for n- propyl from the relative concentrations of n-hexane and propene and for i-propyl from 2,3-dimethyl butane and propene. For n-propyl the ratio is 0.3 and 1.2 for i-propyl, both are independent of temperature and pressure over the experimental range. The disproportionation/recombination ratios are about a factor of 2 higher than prior evaluations that are based mainly on room temperature data. The experimental results are some of the first from the apparatus used and comments are made about the technique, challenges encountered, and suggestions for future developments.
Surface mass loss rates due to sublimation and oxidation at temperatures of 3000–7000 K have been measured in a shock tube for graphite and carbon black (CB) particles. Diagnostics are presented for measuring surface mass loss rates by diffuse backlit illumination extinction imaging and thermal emission. Here, the surface mass loss rate is found by regression fitting extinction and emission signals with an independent spherical primary particle assumption. Measured graphite sublimation and oxidation rates are reported to be an order of magnitude greater than CB sublimation and oxidation rates. It is speculated that the difference between CB and graphite surface mass loss rates is largely due to the primary particle assumption of the presented technique which misrepresents the effective surface area of an aggregate particle where primary particles overlap and shield inner particles. Measured sublimation rates are compared to sublimation models in the literature, and it is seen graphite shows fair agreement with the models while CB underestimates, likely a result of the particle shielding affect not being considered in the sublimation model.
By contrast with the conventional heat transfer fluid (water), the microencapsulated phase change material (MPCM) suspension, with a small temperature difference between storing and releasing heat, is of much larger apparent specific heat and much higher thermal energy storage capacity. It has been suggested to serve as a dual-functional medium for thermal energy transport and/or storage. The heat transfer characteristics of a kind of MPCM suspension, formed by microencapsulating industrial-grade 1-bromohexadecane (C{sub 16}H{sub 33}Br) as phase change material, were experimentally studied for laminar flow in a circular tube under constant heat flux. A new expression of Ste is put forward in the paper, according to the physical definition of Stefan number. The results in the experiments show: (a) the dimensionless internal wall temperature of the MPCM suspension is lower than pure water, and the decrease can be up to 30% of that of water; (b) the heat transfer enhancement ratio can be 1.42 times of that of water at x{sup +} = 4.2 x 10{sup -2} for 15.8 wt% MPCM suspension, which is not as much as in some references; and (c) the pump consumption of the MPCM suspension system decrease greatly for the larger heat transfer rate compared with water, due to phase change, the decrease can be up to 67.5% of that of water at q = 750 W (15.8 wt%). The kind of MPCM suspension has good application feasibility in practice. (author)
Pressure drop behaviour of ice slurry based on ethanol-water mixture in circular horizontal tubes has been experimentally investigated. The secondary fluid was prepared by mixing ethyl alcohol and water to obtain initial alcohol concentration of 10.3% (initial freezing temperature -4.4 C). The pressure drop tests were conducted to cover laminar and slightly turbulent flow with ice mass fraction varying from 0% to 30% depending on test conditions. Results from flow tests reveal much higher pressure drop for higher ice concentrations and higher velocities in comparison to the single phase flow. However for ice concentrations of 15% and higher, certain velocity exists at which ice slurry pressure drop is same or even lower than for single phase flow. It seems that higher ice concentration delay flow pattern transition moment (from laminar to turbulent) toward higher velocities. In addition experimental results for pressure drop were compared to the analytical results, based on Poiseulle and Buckingham-Reiner models for laminar flow, Blasius, Darby and Melson, Dodge and Metzner, Steffe and Tomita for turbulent region and general correlation of Kitanovski which is valid for both flow regimes. For laminar flow and low buoyancy numbers Buckingham-Reiner method gives good agreement with experimental results while for turbulent flow best fit is provided with Dodge-Metzner and Tomita methods. Furthermore, for transport purposes it has been shown that ice mass fraction of 20% offers best ratio of ice slurry transport capability and required pumping power. (author)
Experimental investigation of heat transfer characteristics of circular tube fitted with straight full twist insert has been presented. The heat transfer coefficient increases with Reynolds number and decreasing spacer distance with maximum being 2 in. spacer distance for both the type of twist inserts. Also, there is no appreciable increase in heat transfer enhancement in straight full twist insert with 2 in. spacer distance. Experiments were carried out in turbulent flow using straight full twist insert with 4 in. spacer and similar trend of increasing Nusselt number with Reynolds number was observed. Performance evaluation analysis was made and the maximum performance ratio was obtained for each twist insert corresponding to the Reynolds number of 2550. (author)
A detailed experimental investigation is carried out to study the flow boiling heat transfer behavior of R-134a/R-290/R-600a (91%/4.068%/4.932% by mass) refrigerant mixture in smooth horizontal tubes of diameter 9.52 and 12.7 mm. The heat transfer coefficients of the mixture are experimentally measured under varied heat flux conditions for stratified flow patterns using a coaxial counter-current heat exchanger test section. The tests are conducted for refrigerant inlet temperatures between -9 and 5 C and mass flow rates ranging from 3 to 5 g s{sup -1}. Kattan-Thome-Favrat maps are used to confirm the flow patterns for the tested conditions. The magnitude of the heat transfer coefficient with respect to flow patterns and different mechanisms of boiling are discussed. The heat transfer coefficient of the refrigerant mixture is also compared with that of R-134a for selected working conditions. The significance of nucleate boiling in the overall heat transfer process under these testing conditions is highlighted. (author)
In the present study, the influences of twin-counter/co-twisted tapes (counter/co-swirl tape) on heat transfer rate (Nu), friction factor (f) and thermal enhancement index ({eta}) are experimentally determined. The twin counter twisted tapes (CTs) are used as counter-swirl flow generators while twin co-twisted tapes (CoTs) are used as co-swirl flow generators in a test section. The tests are conducted using the CTs and CoTs with four different twist ratios (y/w = 2.5, 3.0, 3.5 and 4.0) for Reynolds numbers range between 3700 and 21,000 under uniform heat flux conditions. The experiments using the single twisted tape (ST) are also performed under similar operation test conditions, for comparison. The experimental results demonstrate that Nusselt number (Nu), friction factor (f) and thermal enhancement index ({eta}) increase with decreasing twist ratio (y/w). The results also show that the CTs are more efficient than the CoTs for heat transfer enhancement. In the range of the present work, heat transfer rates in the tube fitted with the CTs are around 12.5-44.5% and 17.8-50% higher than those with the CoTs and ST, respectively. The maximum thermal enhancement indices ({eta}) obtained at the constant pumping power by the CTs with y/w = 2.5, 3.0, 3.5 and 4.0, are 1.39, 1.24, 1.12 and 1.03, respectively, while those obtained by using the CoTs with the same range of y/w are 1.1, 1.03, 0.97 and 0.92, respectively. In addition, the empirical correlations of the heat transfer (Nu), friction factor (f) and thermal enhancement index ({eta}) are also reported. (author)
Purpose: To determine the effect of prophylactic gastrostomy tube (GT) placement on acute and long-term outcome for patients treated with definitive chemoradiotherapy for locally advanced head and neck cancer. Methods and Materials: One hundred twenty consecutive patients were treated with chemoradiotherapy for Stage III/IV head and neck cancer to a median dose of 70 Gy (range, 64-74 Gy). The most common primary site was the oropharynx (66 patients). Sixty-seven patients (56%) were treated using intensity-modulated radiotherapy (IMRT). Seventy patients (58%) received prophylactic GT placement at the discretion of the physician before initiation of chemoradiotherapy. Results: Prophylactic GT placement significantly reduced weight loss during radiation therapy from 43 pounds (range, 0 to 76 pounds) to 19 pounds (range, 0 to 51 pounds), which corresponded to a net change of -14% (range, 0% to -30%) and -8% (range, +1% to -22%) from baseline, respectively (p < 0.001). However, the proportion of patients who were GT-dependent at 6- and 12-months after treatment was 41% and 21%, respectively, compared with 8% and 0%, respectively, for those with and without prophylactic GT (p < 0.001). Additionally, prophylactic GT was associated with a significantly higher incidence of late esophageal stricture compared with those who did not have prophylactic GT (30% vs. 6%, p < 0.001). Conclusions: Although prophylactic GT placement was effective at preventing acute weight loss and the need for intravenous hydration, it was also associated with significantly higher rates of late esophageal toxicity. The benefits of this strategy must be balanced with the risks.
Future large water Cherenkov and scintillator detectors have been proposed for measurements of long baseline neutrino oscillations, proton decay, supernova and solar neutrinos. To ensure cost-effectiveness and optimize scientific reach, one of the critical requirements for such detectors are large-area, high performance photomultiplier tubes (PMTs). One candidate for such a device is the Hamamatsu R11780, a 12 in. PMT that is available in both standard and high quantum efficiency versions. Measurements of the single photoelectron response characteristics, relative efficiencies of the standard and high quantum efficiency versions, a preliminary measurement of the absolute quantum efficiency of the standard quantum efficiency version, and a two-dimensional scan of the relative efficiency across the photocathode surface are presented in this paper. All single photoelectron investigations were made using a Cherenkov light source at room temperature at a gain of 1×10 7 . These results show that the R11780 PMT is an excellent candidate for such large optical detectors.