Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Preliminary Simulations for Geometric Optimization of a High-Energy Delayed Gamma Spectrometer for Direct Assay of Pu in Spent Nuclear Fuel

High-energy, beta-delayed gamma-ray spectroscopy is under investigation as part of the Next Generation Safeguard Initiative effort to develop non-destructive assay instruments for plutonium mass quantification in spent nuclear fuel assemblies. Results obtained to date indicate that individual isotope-specific signatures contained in the delayed gamma-ray spectra can potentially be used to quantify the total fissile content and individual weight fractions of fissile and fertile nuclides present in spent fuel. Adequate assay precision for inventory analysis can be obtained using a neutron generator of sufficient strength and currently available detection technology. In an attempt to optimize the geometric configuration and material composition for a delayed gamma measurement on spent fuel, the current study applies MCNPX, a Monte Carlo radiation transport code, in order to obtain the best signal-to-noise ratio. Results are presented for optimizing the neutron spectrum tailoring material, geometries to maximize thermal or fast fissions from a given neutron source, and detector location to allow an acceptable delayed gamma-ray signal while achieving a reasonable detector lifetime while operating in a high-energy neutron field. This work is supported in part by the Next Generation Safeguards Initiative, Office of Nuclear Safeguards and Security, National Nuclear Security Administration.

Delayed Gamma Spectroscopy, active interrogation, ↗

A Bayesian Method for Identifying Contaminated Detectors in Low-Level Alpha Spectrometers

Analyses used for radiobioassay and other radiochemical tests are normally designed to meet specified quality objectives, such relative bias, precision, and minimum detectable activity (MDA). In the case of radiobioassay analyses for alpha emitting radionuclides, a major determiner of the process MDA is the instrument background. Alpha spectrometry detectors are often restricted to only a few counts over multi-day periods in order to meet required MDAs for nuclides such as plutonium-239 and americium-241. A detector background criterion is often set empirically based on experience, or frequentist or classical statistics are applied to the calculated background count necessary to meet a required MDA. An acceptance criterion for the detector background is set at the multiple of the estimated background standard deviation above the assumed mean that provides an acceptably small probability of observation if the mean and standard deviation estimate are correct. The major problem with this method is that the observed background counts used to estimate the mean, and thereby the standard deviation when a Poisson distribution is assumed, are often in the range of zero to three counts. At those expected count levels it is impossible to obtain a good estimate of the true mean from a single measurement. As an alternative, Bayesian statistical methods allow calculation of the expected detector background count distribution based on historical counts from new, uncontaminated detectors. This distribution can then be used to identify detectors showing an increased probability of contamination. The effect of varying the assumed range of background counts (i.e., the prior probability distribution) from new, uncontaminated detectors will be is discussed.

alpha↗

Two-dimensional fourier transform spectrometer

The present invention relates to a system and methods for acquiring two-dimensional Fourier transform (2D FT) spectra. Overlap of a collinear pulse pair and probe induce a molecular response which is collected by spectral dispersion of the signal modulated probe beam. Simultaneous collection of the molecular response, pulse timing and characteristics permit real time phasing and rapid acquisition of spectra. Full spectra are acquired as a function of pulse pair timings and numerically transformed to achieve the full frequency-frequency spectrum. This method demonstrates the ability to acquire information on molecular dynamics, couplings and structure in a simple apparatus. Multi-dimensional methods can be used for diagnostic and analytical measurements in the biological, biomedical, and chemical fields.

47 OTHER INSTRUMENTATION↗

Combined distance-of-flight and time-of-flight mass spectrometer

A combined distance-of-flight mass spectrometry (DOFMS) and time-of-flight mass spectrometry (TOFMS) instrument includes an ion source configured to produce ions having varying mass-to-charge ratios, a first detector configured to determine when each of the ions travels a predetermined distance, a second detector configured to determine how far each of the ions travels in a predetermined time, and a detector extraction region operable to direct portions of the ions either to the first detector or to the second detector.

47 OTHER INSTRUMENTATION↗