Results of Hg Speciation Testing on 2Q15 Tank 50 WAC and Cs-Decontaminated Tank 21 Waste Samples (Rev.1)

The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team. The fourth shipment of samples was designated to include 2Q15 Tank 50 WAC material (HTF-50-15-39) collected on April 7, 2015, and Tank 21 material (HTF-21-15-32, HTF-21-15-36, and HTF-21-15-37) the first collected on March 9 and the second two collected on April 6, 2015. The combined samples were subjected to Cs-decontamination through the use of MCU solvent. Samples were collected with the minimum possible free headspace and refrigerated prior to final dilution.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sludge batch 9 (SB9) accepance evaluation: Radionuclide concentrations in tank 51 SB9 qualification sample prepared at SRNL

Presented in this report are radionuclide concentrations required as part of the program of qualifying Sludge Batch 9 (SB9) for processing in the Defense Waste Processing Facility (DWPF). The SB9 material is currently in Tank 51 and has been washed and prepared for transfer to Tank 40. The acceptance evaluation needs to be completed prior to the transfer of the material in Tank 51 to Tank 40. The sludge slurry in Tank 40 has already been qualified for DWPF processing and is currently being processed as Sludge Batch 8 (SB8). The radionuclide concentrations were measured or estimated in the Tank 51 SB9 Washed Qualification Sample prepared at Savannah River National Laboratory (SRNL). This sample was prepared from a three liter sample of Tank 51 sludge slurry (HTF-51-15-81) taken on July 23, 2015. The sample was delivered to SRNL where it was initially characterized in the Shielded Cells. Under the direction of Savannah River Remediation (SRR) it was then adjusted per the Tank Farm washing strategy as of October 20, 2015. This final slurry now has a compositioniv expected to be similar to that of the slurry in Tank 51 after final preparations have been made for transfer of that slurry to Tank 40.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Manipulation of Samples at Extreme Temperatures for Fast in-situ Synchrotron Measurements

An aerodynamic sample levitation system with laser beam heating was integrated with the APS beamlines 6 ID-D, 11 ID-C and 20 BM-B. The new capability enables in-situ measurements of structure and XANES at extreme temperatures (300-3500 °C) and in conditions that completely avoid contact with container surfaces. In addition to maintaining a high degree of sample purity, the use of aerodynamic levitation enables deep supercooling and greatly enhanced glass formation from a wide variety of melts and liquids. Development and integration of controlled extreme sample environments and new measurement techniques is an important aspect of beamline operations and user support. Processing and solidifying liquids is a critical value-adding step in manufacturing semiconductors, optical materials, metals and in the operation of many energy conversion devices. Understanding structural evolution is of fundamental importance in condensed materials, geology, and biology. The new capability provides unique possibilities for materials research and helps to develop and maintain a competitive materials manufacturing and energy utilization industry. Test samples were used to demonstrate key features of the capability including experiments on hot crystalline materials, liquids at temperatures from about 500 to 3500 °C. The use of controlled atmospheres using redox gas mixtures enabled in-situ changes in the oxidation states of cations in melts. Significant innovations in this work were: (i) Use of redox gas mixtures to adjust the oxidation state of cations in-situ (ii) Operation with a fully enclosed system suitable for work with nuclear fuel materials (iii) Making high quality high energy in-situ x-ray diffraction measurements (iv) Making high quality in-situ XANES measurements (v) Publishing high impact results (vi) Developing independent funding for the research on nuclear materials This SBIR project work led to a commercial instrument product for the niche market of processing and studying materials in extreme conditions. MDI registered the trademark “Instruments for Innovation®” and sells products under this trademark. SBIR is the ideal vehicle for funding developments such as this since the total market size is relatively small meaning that venture investments to develop products cannot typically be obtained. The sale of niche market instruments for work in extreme conditions has been several million dollars over the last decade. The work to develop and build and sell this instrument has created stable high paying jobs in the technology manufacturing sector. Outreach enabled by this research helped with PhD thesis research, supported three undergraduate interns and one local high school student. In addition, several scientific articles were published, papers were presented at international conferences, and a workshop was held.

36 MATERIALS SCIENCE↗

2015 Long-Term Hydrologic Monitoring Program Sampling and Analysis Results Report for Project Rulison, Co

The U.S. Department of Energy (DOE) Office of Legacy Management conducted annual sampling at the Rulison, Colorado, Site for the Long-Term Hydrologic Monitoring Program (LTHMP) on May 20–22 and 27, 2015. Several of the land owners were not available to allow access to their respective properties, which created the need for several sample collection trips. This report documents the analytical results of the Rulison monitoring event and includes the trip report and the data validation package (Appendix A). The groundwater and surface water monitoring were shipped to the GEL Group Inc. laboratories for analysis. All requested analyses were successfully completed. Samples were analyzed for gamma-emitting radionuclides by high- resolution gamma spectrometry. Tritium was analyzed using two methods, the conventional tritium method, which has a detection limit on the order of 400 picocuries per liter (pCi/L), and the enriched method (for selected samples), which has a detection limit on the order of 3 pCi/L.

54 ENVIRONMENTAL SCIENCES↗

Results of initial analyses of the salt (macro) batch 10 tank 21H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 10 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 10 composite sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amount of solids, or unusual colors. Further sample results will be reported in a future document. This memo satisfies part of Deliverable 3 of the Technical Task Request (TTR).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Pipeline for Large Data Processing Using Regular Sampling for Unstructured Grids

Large simulation data requires a lot of time and computational resources to compute, store, analyze, visualize, and run user studies. Today, the largest cost of a supercomputer is not hardware but maintenance, in particular energy consumption. Our goal is to balance energy consumption and cognitive value of visualizations of resulting data. This requires us to go through the entire processing pipeline, from simulation to user studies. To reduce the amount of resources, data can be sampled or compressed. While this adds more computation time, the computational overhead is negligible compared to the simulation time. We built a processing pipeline at the example of regular sampling. The reasons for this choice are two-fold: using a simple example reduces unnecessary complexity as we know what to expect from the results. Furthermore, it provides a good baseline for future, more elaborate sampling methods. We measured time and energy for each test we did, and we conducted user studies in Amazon Mechanical Turk (AMT) for a range of different results we produced through sampling.

97 MATHEMATICS AND COMPUTING↗

Analytical results from salt batch 9 routine DSSHT and SEHT monthly samples

Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 9 have been analyzed for 238 Pu, 90 Sr, 137 Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Cs removal continues to be acceptable, with decontamination factors (DF) averaging 25700 (107% RSD). The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior, other than lacking the anticipated degree of dilution that is calculated to occur during Modular Caustic-Side Solvent Extraction Unit (MCU) processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Final Report: Sampling-Based Algorithms for Estimating Structure in Big Data.

The purpose of this project was to develop sampling-based algorithms to discover hidden struc- ture in massive data sets. Inferring structure in large data sets is an increasingly common task in many critical national security applications. These data sets come from myriad sources, such as network traffic, sensor data, and data generated by large-scale simulations. They are often so large that traditional data mining techniques are time consuming or even infeasible. To address this problem, we focus on a class of algorithms that do not compute an exact answer, but instead use sampling to compute an approximate answer using fewer resources. The particular class of algorithms that we focus on are streaming algorithms , so called because they are designed to handle high-throughput streams of data. Streaming algorithms have only a small amount of working storage - much less than the size of the full data stream - so they must necessarily use sampling to approximate the correct answer. We present two results: * A streaming algorithm called HyperHeadTail , that estimates the degree distribution of a graph (i.e., the distribution of the number of connections for each node in a network). The degree distribution is a fundamental graph property, but prior work on estimating the degree distribution in a streaming setting was impractical for many real-world application. We improve upon prior work by developing an algorithm that can handle streams with repeated edges, and graph structures that evolve over time. * An algorithm for the task of maintaining a weighted subsample of items in a stream, when the items must be sampled according to their weight, and the weights are dynamically changing. To our knowledge, this is the first such algorithm designed for dynamically evolving weights. We expect it may be useful as a building block for other streaming algorithms on dynamic data sets.

97 MATHEMATICS AND COMPUTING↗

Subsurface Noble Gas Sampling Manual

The intent of this document is to provide information about best available approaches for performing subsurface soil gas sampling during an On Site Inspection or OSI. This information is based on field sampling experiments, computer simulations and data from the NA-22 Noble Gas Signature Experiment Test Bed at the Nevada Nuclear Security Site (NNSS). The approaches should optimize the gas concentration from the subsurface cavity or chimney regime while simultaneously minimizing the potential for atmospheric radioxenon and near-surface Argon-37 contamination. Where possible, we quantitatively assess differences in sampling practices for the same sets of environmental conditions. We recognize that all sampling scenarios cannot be addressed. However, if this document helps to inform the intuition of the reader about addressing the challenges resulting from the inevitable deviations from the scenario assumed here, it will have achieved its goal.

58 GEOSCIENCES↗

Treatment of Nuclear Data Covariance Information in Sample Generation

This report summarizes a NEAMS (Nuclear Energy Advanced Modeling and Simulation) project focused on developing a sampling capability that can handle the challenges of generating samples from nuclear cross-section data. The covariance information between energy groups tends to be very ill-conditioned and thus poses a problem using traditional methods for generated correlated samples. This report outlines a method that addresses the sample generation from cross-section matrices.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results of initial analyses of the salt (macro) batch 11 Tank 21H qualification samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 11 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 11 composite sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amounts of solids, or unusual colors. Further sample results will be reported in a future document. This memo satisfies part of Deliverable 3 of the Technical Task Request (TTR).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sample Generation for Nuclear Data

This report summarizes a NEAMS (Nuclear Energy Advanced Modeling and Simulation) project focused on developing a sampling capability that can handle the challenges of generating samples from nuclear cross-section data. The covariance information between energy groups tends to be very ill-conditioned and thus poses a problem using traditional methods for generated correlated samples. This report outlines a method that addresses the sample generation from cross-section matrices. The treatment allows one to assume the cross sections are distributed with a multivariate normal distribution, lognormal distribution, or truncated normal distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced Diagnostic and Sample Preparation Platform for Early Threat Surveillance

Emerging infectious diseases present a profound threat to global health, economic development, and political stability, and therefore represent a significant national security concern for the United States. The increased prevalence of international travel and globalized trade further amplify the threat of infectious disease outbreaks of catastrophic effect. The key to containing and eradicating an outbreak before it goes global is rapid identification of index cases and initial clusters of affected individuals. This depends upon establishment of a biosurveillance network that effectively reaches infectious disease hotspots in even the most remote regions of the world and provides a network-integrated, location-appropriate diagnostic capability. At present, there are two critical needs which must be addressed in order to extend biosurveillance activities beyond centralized laboratory facilities: 1) A simple, reliable, and safe method for immediate stabilization of clinical specimens in the field; and 2) A flexible sample processing platform that enables in-field preparation of clinical specimens for rapid, on-site analysis using a variety of diagnostic assay platforms. These needs are not necessarily mutually exclusive; in fact, we propose that they are most efficiently addressed by a deployable sample processing platform that immediately stabilizes the information content of clinical specimens through transformation of the inherently unstable analytes of interest into stable equivalents that are appropriately formatted for downstream analysis. In order to address this problem, we have developed a sample processing pipeline and microfluidics-based platform modules enabling: 1) Extraction of total RNA from finger-stick quantities of human whole blood; and 2) Microscale synthesis of appropriately-formatted cDNA products that capture the information content of blood RNA in a stable form that supports pathogen detection and/or characterization via PCR and/or Second Generation Sequencing (SGS). Through this research we have discovered new, effective solutions for problems that thus far have hindered use of digital microfluidics (DMF) in biomedical applications. Our work reveals a clear path forward to fieldable, automated sample processing systems that will enable rapid, on-site identification of usual-suspect and novel pathogens in clinical specimens for improved biosurveillance.

59 BASIC BIOLOGICAL SCIENCES↗

Ultra-Sensitive Measurements of Large-Volume Radioxenon Samples Using an Ultra-Low-Background Proportional Counter (ULBPC) (Final Report)

This project investigated the feasibility of analyzing radioxenon samples in much larger quantities than currently used by the International Monitoring System (IMS). There is interest within the PTS and the international community in the ability to obtain xenon samples using the output of industrial oxygen plants, which could provide samples that are larger by three orders of magnitude, or more, than those currently provided by IMS stations. Such samples would best be analyzed using internal-source gas proportional counters, though the details of that approach and its sensitivity and limits were previously not examined. This report details the outcomes of a task designed to 1) analyze xenon radioisotope data collected previously via internal-source gas proportional counting and 2) collect additional gas proportional counter measurements to determine feasible gas blends for large volume xenon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tank 22 Supernate Sample Characterization for Select Radionuclides

The Savannah River National Laboratory (SRNL) was requested by Savannah River Remediation (SRR), through a Technical Assistance Request (G-TAR-H-00007) to provide additional sample characterization on unfiltered Tank 22 supernate identified as sample HTF-22-18-117, which was delivered to SRNL Shielded Cells on December 14, 2018. A summary of the average analytical results for this unfiltered Tank 22 supernate liquid follows. The density of the unfiltered Tank 22 supernate is 1.008 g/mL, 0.2%RSD. The Tank 22 supernate sample was analyzed for a total of 45 radionuclide species, with 15 of these radionuclides showing activity levels above minimum detectable activity of at least one replicate. Cesium-137 showed the highest activity at 2.90E+07 dpm/mL, 2.35 %RSD (1.30E-02 Ci/ L) with U-235 showing the lowest measurable activity at an average of 1.66E-01 dpm/mL, 6.26 %RSD (7.49E-11 Ci/L). The primary beta emitting radionuclides in the unfiltered Tank 22 supernate sample include Sr-90, Y-90 and Cs-137 at average activity concentrations of 1.10E-05, 1.10E-05 and 1.30E-02 Ci/L, respectively. The primary gamma emitting radionuclide is Ba-137 m at an average activity concentration of 1.23E-02 Ci/L (note that the activity concentration for Ba-137 m was calculated as 94.7% the Cs-137 activity concentration).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analytical Results from Salt Batch 10 Routine DSSHT and SEHT Monthly Samples

Strip Effluent (SE) Hold Tank (SEHT) and Decontaminated Salt Solution (DSS) Hold Tank (DSSHT) samples from several “microbatches” of the Integrated Salt Disposition Project (ISDP) “macrobatch” Salt Batch 10 have been analyzed for 238 Pu, 90 Sr, 137 Cs, cations (via Inductively Coupled Plasma Emission Spectroscopy - ICPES), and in some cases anions (via Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatches. In the Modular Caustic-Side Solvent Extraction Unit (MCU), the Cs removal continues to exceed process requirements. The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior except for slightly elevated amounts of sodium in the SE samples. This summary represents the final Salt Batch processed through MCU prior to commencement of process and transfer line tie-ins to support the startup of the Salt Waste Processing Facility (SWPF).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

California GAMA Special Study: Excess Nitrogen and Methane in Noble Gas Samples

The most prominent constituent causing concern for drinking water resources in California is nitrate. Denitrification in the unsaturated zone and in groundwater naturally reduces nitrate concentrations, controls the fate of groundwater nitrate and determines the time scale over which changes in management practice will result in improvements in water quality. Quantifying denitrification is also important in estimating nutrient loading to groundwater through time. Measurements of dissolved nitrogen gas can detect and quantify saturated zone denitrification; and LLNL with GAMA funding has developed benchtop instrumentation to measure dissolved nitrogen in groundwater. This technique, membrane-inlet mass spectrometry (MIMS) requires the collection of an additional sample and is not routinely included in current GAMA water quality monitoring surveys. Incorporating dissolved nitrogen analysis into current water quality monitoring protocols without requiring an additional sample or separate analysis is the most cost-effective way to expand the database of dissolved nitrogen concentrations and document the prevalence of saturated-zone denitrification in California groundwater. The GAMA Priority Basin, Shallow Aquifer Assessment, and Special Study water quality monitoring programs routinely use dissolved noble gas and tritium analyses to constrain groundwater travel times and recharge. Noble gases are collected as a 10-mL water sample in a crimped copper tube and are analyzed by noble gas mass spectrometry (NGMS). Nitrogen, methane and carbon dioxide, can now also be measured in copper tubes and analyzed by the same LLNL NGMS system, which has been upgraded to allow such analyses. In the case of the GAMA Shallow Aquifer Assessment project, this will automatically provide dissolved nitrogen analyses at little or no incremental cost. A significant advantage of this technique is that archival copper tube noble gas samples can be analyzed using the technique. The dissolved nitrogen analyses – combined with nitrate analyses and the NGMS age information – will provide unique insight into nitrate sources, inputs, transport, and reaction rates.

54 ENVIRONMENTAL SCIENCES↗

Results of Initial Analyses of the Salt Waste Processing Facility (SWPF) Batch 2 Tank 21H Qualification Samples

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Salt Waste Processing Facility (SWPF) Batch 2 for processing. This document reports the initial expedited results of the analyses of the Tank 21H qualification sample. Analysis of the Tank 21H SWPF Batch 2 sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amounts of solids, or unusual color. Further sample results will be reported in a future document. This memo satisfies part of Deliverable 3 of the Technical Task Request (TTR).