Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sample Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Fabrication and processing of next-generation oxygen carrier materials for chemical looping combustion

Among numerous methods of controlling the global warming effect, Chemical Looping Combustion is known to be the most viable option currently. A key factor to a successful chemical looping process is the presence of highly effective oxygen carriers that enable fuel combustion by going through oxidation and reduction in the presence of air and fuel respectively. In this study, CaMnO 3-δ was used as the base material and doped on the A-site (Sr or La) and B-site (Fe, Ti, Zn and Al) by 10 mol % of dopants. Solid state reaction followed by mechanical extrusion (optimized paste formula) was used as the preparation method A series of novel doped perovskite-type oxygen carrier particles (Ca x La (Or Sa) 1-x Mn 1-y ByO 3-δ (B-site = Fe, Ti, Al, or Zr)) were synthesized by the proposed extrusion formula. The produced samples were characterized with XRD, SEM, BET and TGA techniques. According to the results obtained from TGA analysis, the oxygen capacity of the samples ranged between 1.2 for CLMZ and 1.75 for CSMF. Reactivity and oxygen uncoupling behaviors of the prepared samples were also evaluated using a fluidized bed chemical looping reactor using methane as the fuel at four different temperatures (800, 850, 900, 950 °C). All of the oxygen carriers showed oxygen uncoupling behavior and they were able to capture and release oxygen. Mass-based conversion of the perovskites was calculated and temperature increase proved to increase the mass-based conversion rate in all of the samples under study. Gas yield was calculated at 950 °C as well, and results showed that CLMZ, CM and CSMF showed 100% gas yields and CLMF and CSMZ showed approximately 85% yield in fluidized bed reactor, which is a high and acceptable quantity. Based on extended reactor tests the modified calcium manganese perovskite structures (CSMF) can be a good candidate for future pilot tests.

30 DIRECT ENERGY CONVERSION↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

Raman thermometry: Effective temperature of the nonuniform temperature field induced by a Gaussian laser

Raman spectroscopy is a widely applied analytical technique with numerous applications that is based on inelastic scattering of monochromatic light, which is typically provided by a laser. Irradiation of a sample by a laser beam is always accompanied by an increase in the sample temperature, which may be unwanted or may be beneficial for studying temperature-related effects and determining thermal parameters. This work reports analyses of the temperature field induced by a Gaussian laser to calculate the Raman scattered intensity related to each temperature value of the nonuniform field present on the sample. The effective temperature of the probed field, calculated as an average weighted by the laser intensity, is demonstrated to be about 70% of the maximum temperature irrespective of the absorption coefficient or the laser focus. Finally, using crystalline silicon as a model material, it is shown that this effective value closely approximates the temperature value identified from the thermally related peak shift.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Flux Estimation of a PuBe source using Delayed Gamma Neutron Activation Analysis

For handling and storage of a highly radioactive source, it is necessary to have an accurate knowledge of the radioactive source as well as the neutron flux. Recently, due to radiation safety requirements, a PuBe alpha-neutron source at an activation facility at IIT-Kanpur had to be taken out of its original damaged howitzer and placed inside a new shielded container. While, this effort was successful in reducing the radiation dose, and making the setup safe for laboratory measurements, the new source moderator configuration left the new Pu-Be source spectrum unknown. Therefore, in this work we have used delayed gamma neutron activation analysis (DGNAA) of aluminum, copper, iron, manganese (found in iron), and silver for thermal neutron flux estimation of the Pu-Be neutron source. A series of DGNAA measurements with different samples were carried out to find the value of the average thermal neutron flux of a Pu-Be neutron source at Indian Institute of Technology-Kanpur. The order of the thermal neutron flux is found to be nearly 1.64 x 10{sup 5} excluding aluminum. Upon including aluminum, the value of thermal neutron flux decreases to 1.57x10{sup 5}. We have used common metals (like aluminum, silver, copper and iron) to calculate the thermal neutron flux. The calculated value of the thermal neutron flux is consistent for all the metals except for iron. Iron is giving a value almost four times larger than the average calculated value of the thermal neutron flux using other six samples. The reason is currently being investigated. The DGNAA technique came out to be a very useful technique. Now that we know the thermal neutron flux of the Pu-Be source, our future work will include improving the safety and shielding calculations for our activation facility at IIT-Kanpur. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Historic climate, cosmogenic 10Be, denudation-rate, and geospatial datasets from the Pikes Peak region, Colorado, USA

This data package contains geographic information system (GIS) layers and tabular datasets associated with the study of elevation-dependent denudation rates on Pikes Peak in the Front Range of the Rocky Mountains, Colorado, USA. The package includes GIS layers used to produce the study-area map, including sample locations, sample watershed boundaries, the Pikes Peak batholith, Pleistocene glacier extent, weather station locations, and elevation and hillshade rasters, together with comma-separated value (CSV) tables and matching CSV data dictionaries. These mapped layers provide the geographic framework for interpreting denudation patterns across the Pikes Peak region and for relating sample locations to watershed geometry, bedrock setting, glacial history, and nearby climate stations. The first group of tables reports climate and geospatial context for the study area. These files include station-based temperature and precipitation data used to characterize elevational gradients in mean annual climate and monthly climate seasonality, sample locations, denudation-rate and topographic metrics, fixed frost-cracking model parameters, frost-cracking intensity and precipitation-frequency metrics, and stream-power inversion results. Together, these data provide the basis for evaluating how denudation varies with elevation, climate, and landscape form across sampled catchments on Pikes Peak. The second group of tables reports cosmogenic nuclide and erosion-model results used in the denudation analysis. Included files contain accelerator mass spectrometry (AMS) measurements for in situ-produced cosmogenic beryllium-10 (10Be), including sample identifiers, measured 10Be:9Be ratios, analytical uncertainties, carrier mass, quartz mass, blank corrections, blank-group statistics, and calculated 10Be concentrations and uncertainties. Additional tables summarize stream-power-law inversion results for sampled catchments, including optimized model parameters, predicted erosion rates, residual metrics, channel-pixel counts, and convergence status, as well as regression equations and summary statistics used to evaluate relationships among elevation, climate, frost cracking, precipitation forcing, and denudation rate. The package contains GIS files, comma-separated value files (.csv), Microsoft Excel files (.xlsx), CSV data dictionaries, a file-level metadata table, and a readme text file.

10Be cosmogenic nuclides↗

Implementation of structural response sensitivity calculations in a large-scale finite-element analysis system

The methodology used to implement structural sensitivity calculations into a major, general-purpose finite-element analysis system (SPAR) is described. This implementation includes a generalized method for specifying element cross-sectional dimensions as design variables that can be used in analytically calculating derivatives of output quantities from static stress, vibration, and buckling analyses for both membrane and bending elements. Limited sample results for static displacements and stresses are presented to indicate the advantages of analytically calculating response derivatives compared to finite difference methods. Continuing developments to implement these procedures into an enhanced version of SPAR are also discussed.

Giles, G. L.↗

Sample band spreading phenomena in ground and space-based electrophoretic separators

Sample stream spreading in the transverse direction (direction perpendicular to the chamber center plane) is calculated for two ground-based and one space-based continuous flow electrophoresis chambers. The magnitude of transverse sample stream spreading is shown to be a function of the difference in electrical conductivity between the sample and curtain buffer. Sample/buffer conductivity mismatch distorts the normally uniform electrical field in the vicinity of the sample to produce transverse field components which, in turn, deflect sample material toward the chamber walls. These results indicate that nongravity effects are important and must be resolved in order for space-based continuous flow electrophoresis to achieve its maximum potential.

Rhodes, Percy H.↗

Monthly Sewer Monitoring Report for LLNL Livermore Site, April 2020

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyzes these compliance samples, and results (Tables 1–3) are used to establish LLNL compliance with the 2019–2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported (Table 4) for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L). The results are presented in Table 5. In addition to the sampling noted above, the SMS continuously monitors LLNL sewage effluent in real-time for flow rate, pH, metals, and radioactivity. Standard measurement methods are used to monitor flow and pH to determine permit compliance. Unique nonstandard analytical methods monitor for the presence of metals and radioactivity using x-ray fluorescence (XRF) and gamma spectroscopy, respectively. If an anomalous condition is detected by the monitoring system, an alarm activates LLNL’s Sewer Diversion Facility (SDF) and Livermore Water Reclamation Plant (LWRP) operators are notified that a potential release has occurred.

54 ENVIRONMENTAL SCIENCES↗

Detailed high-accuracy megavoltage transmission measurements: A sensitive experimental benchmark of EGSnrc

Purpose: There are three goals for this study: (a) to perform detailed megavoltage transmission measurements in order to identify the factors that affect the measurement accuracy, (b) to use the measured data as a benchmark for the EGSnrc system in order to identify the computational limiting factors, and (c) to provide data for others to benchmark Monte Carlo codes. Methods: Transmission measurements are performed at the National Research Council Canada on a research linac whose incident electron parameters are independently known. Automated transmission measurements are made on-axis, down to a transmission value of {approx}1.7%, for eight beams between 10 MV (the lowest stable MV beam on the linac) and 30 MV, using fully stopping Be, Al, and Pb bremsstrahlung targets and no fattening filters. To diversify energy differentiation, data are acquired for each beam using low-Z and high-Z attenuators (C and Pb) and Farmer chambers with low-Z and high-Z buildup caps. Experimental corrections are applied for beam drifts (2%), polarity (2.5% typical maximum, 6% extreme), ion recombination (0.2%), leakage (0.3%), and room scatter (0.8%)-the values in parentheses are the largest corrections applied. The experimental setup and the detectors are modeled using EGSnrc, with the newly added photonuclear attenuation included (up to a 5.6% effect). A detailed sensitivity analysis is carried out for the measured and calculated transmission data. Results: The developed experimental protocol allows for transmission measurements with 0.4% uncertainty on the smallest signals. Suggestions for accurate transmission measurements are provided. Measurements and EGSnrc calculations agree typically within 0.2% for the sensitivity of the transmission values to the detector details, to the bremsstrahlung target material, and to the incident electron energy. Direct comparison of the measured and calculated transmission data shows agreement better than 2% for C (3.4% for the 10 MV beam) and typically better than 1% for Pb. The differences can be explained by acceptable photon cross section changes of Less-Than-Or-Slanted-Equal-To 0.4%. Conclusions: Accurate transmission measurements require accounting for a number of influence quantities which, if ignored, can collectively introduce errors larger than 10%. Accurate transmission calculations require the use of the most accurate data and physics options available in EGSnrc, particularly the more accurate bremsstrahlung angular sampling option and the newly added modeling of photonuclear attenuation. Comparison between measurements and calculations implies that EGSnrc is accurate within 0.2% for relative ion chamber response calculations. Photon cross section uncertainties are the ultimate limiting factor for the accuracy of the calculated transmission data (Monte Carlo or analytical).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Volume Measurements of Laser-generated Pits for In Situ Geochronology using KArLE (Potassium-Argon Laser Experiment)

The Potassium-Argon Laser Experiment( KArLE), is composed of two main instruments: a spectrometer as part of the Laser-Induced Breakdown Spectroscopy (LIBS) method and a Mass Spectrometer (MS). The LIBS laser ablates a sample and creates a plasma cloud, generating a pit in the sample. The LIBS plasma is measured for K abundance in weight percent and the released gas is measured using the MS, which calculates Ar abundance in mols. To relate the K and Ar measurements, total mass of the ablated sample is needed but can be difficult to directly measure. Instead, density and volume are used to calculate mass, where density is calculated based on the elemental composition of the rock (from the emission spectrum) and volume is determined by pit morphology. This study aims to reduce the uncertainty for KArLE by analyzing pit volume relationships in several analog materials and comparing methods of pit volume measurements and their associated uncertainties.

French, R. A.↗

Novel Hybrid Monte Carlo/Deterministic Technique for Shutdown Dose Rate Analyses of Fusion Energy Systems

The rigorous 2-step (R2S) method uses three-dimensional Monte Carlo transport simulations to calculate the shutdown dose rate (SDDR) in fusion reactors. Accurate full-scale R2S calculations are impractical in fusion reactors because they require calculating space- and energy-dependent neutron fluxes everywhere inside the reactor. The use of global Monte Carlo variance reduction techniques was suggested for accelerating the neutron transport calculation of the R2S method. The prohibitive computational costs of these approaches, which increase with the problem size and amount of shielding materials, inhibit their use in the accurate full-scale neutronics analyses of fusion reactors. This paper describes a novel hybrid Monte Carlo/deterministic technique that uses the Consistent Adjoint Driven Importance Sampling (CADIS) methodology but focuses on multi-step shielding calculations. The Multi-Step CADIS (MS-CADIS) method speeds up the Monte Carlo neutron calculation of the R2S method using an importance function that represents the importance of the neutrons to the final SDDR. Using a simplified example, preliminarily results showed that the use of MS-CADIS enhanced the efficiency of the neutron Monte Carlo simulation of an SDDR calculation by a factor of 550 compared to standard global variance reduction techniques, and that the increase over analog Monte Carlo is higher than 10,000.

hybrid Monte Carlo/deterministic↗

The diagnostic capability of x-ray scattering parameters for the characterization of breast cancer

Purpose: The evaluation of the diagnostic capability of easy to measure x-ray scattering profile characterization parameters for the detection of breast cancer in excised samples. The selected parameters are the full width at half maximum (FWHM) and area under the x-ray scattering profile of breast tissue in addition to the ratio of scattering intensities (I{sub 2}/I{sub 1}%) at 1.6 nm{sup -1} to that at 1.1 nm{sup -1} (corresponding to scattering from soft and adipose tissues, respectively). Methods: A histopathologist is asked to classify 36 excised breast tissue samples into healthy or malignant. A conventional x-ray diffractometer is used to acquire the scattering profiles of the investigated samples. The values of three profile characterization parameters are calculated and the diagnostic capability of each is evaluated by determining the optimal cutoffs of scatter diagrams, calculating the diagnostic indices, and plotting the receiver operating characteristic (ROC) curves. Results: At the calculated optimal cutoff for each of the examined parameters, the sensitivity ranged from 78% (for area under curve) up to 94% (for FWHM), the specificity ranged from 94%[for I{sub 2}/I{sub 1}% and area under curve] up to 100% (for FWHM), and the diagnostic accuracy ranged from 86% (for area under curve) up to 97% (for FWHM). The area under the ROC curves is greater than 0.95 for all of the investigated parameters, reflecting a highly accurate diagnostic performance. Conclusions: The discussed tests offered a means to quantitatively evaluate the performance of the suggested breast tissue x-ray scattering characterization parameters. The performance results are promising, indicating that the evaluated parameters would be considered a tool for fast, on spot probing of breast cancer in excised tissue samples.

60 APPLIED LIFE SCIENCES↗

KSSOLV 2.0: An efficient MATLAB toolbox for solving the Kohn-Sham equations with plane-wave basis set

KSSOLV (Kohn-Sham Solver) is a MATLAB toolbox for performing Kohn-Sham density functional theory (DFT) calculations with a plane-wave basis set. KSSOLV 2.0 preserves the design features of the original KSSOLV software to allow users and developers to easily set up a problem and perform ground-state calculations as well as to prototype and test new algorithms. Furthermore, it includes new functionalities such as new iterative diagonalization algorithms, k-point sampling for electron band structures, geometry optimization and advanced algorithms for performing DFT calculations with local, semi-local, and hybrid exchange-correlation functionals. It can be used to study the electronic structures of both molecules and solids. So, we describe these new capabilities in this work through a few use cases. We also demonstrate the numerical accuracy and computational efficiency of KSSOLV on a variety of examples.

97 MATHEMATICS AND COMPUTING↗

MCNP 6.2.0 Delayed-Particle Production Improvements

Development began on a delayed-particle physics package for the Monte Carlo Radiation transport code MCNPX in 2004 incorporating the CINDER90 depletion code and delayed particle libraries. When MCNP5 was merged with MCNPX to form MCNP6 in 2010, this delayed-particle capability was passed on and has been continuously improved in subsequent versions of MCNP6. Today, the delayed-particle feature in MCNP6 allows for the production of delayed neutrons, gammas, betas, and alpha particles. Future development includes the addition of delayed-positron production in the next release of MCNP6. Delayed particles can be sampled with MCNP using the ACT card in conjunction with the FISSION and NONFISS keywords. The user can specify one or more of the four available delayed-particle types mentioned above on one or both of the FISSION and NONFISS keywords. If a delayed-particle type is selected on the FISSION keyword, then delayed production of that particle from fission products and their progeny will be produced. Likewise, if a delayed-particle type is selected on the NONFISS keyword then delayed production of that particle from non-fission interactions and spontaneous decay will be produced. In some cases, the sheer number of delayed particles that can be produced from nuclear reactions and spontaneous decay (i.e. hundreds of delayed gamma lines when spontaneous fission is possible) can make it difficult to achieve converged solutions in an efficient and timely manner. Truncation methods are the simplest form of variance reduction and can be used to decrease convergence times by limiting calculations to the phase space of interest. This paper introduces several such truncation methods that allow the user to restrict the number of possible delayed particles available for sampling to only those of interest in the problem. It is important to stress that the use of any truncation method should be verified by first assessing the impact of the truncated particles (i.e. by disabling the truncation) for one or more baseline cases. In addition to these new methods, a new delayed-gamma sampling algorithm implemented in MCNP 6.2.0 is introduced. Comparisons to ENDF data and analytical benchmarking with the new algorithm show a substantial improvement in accuracy over previous versions. New improvements to the delayed-particle capability have been added to MCNP 6.2.0. These improvements include an updated treatment of the THRESH keyword which omits delayed-particle lines below a set amplitude, and addition of the PECUT and HLCUT keywords which allow the user to truncate delayed-particles lines based on energy and half-life, respectively. The delayed-gamma sampling algorithm has also been improved to allow exact energy sampling. Comparisons of MCNP calculations directly to ENDF data and analytical benchmarks have verified the significant improvement in the new delayed gamma sampling algorithm. (authors)

97 MATHEMATICS AND COMPUTING↗

Velocity surface measurements for ZnO films over /001/-cut GaAs

A potential application for a piezoelectic film deposited on a GaAs substrate is the monolithic integration of surface acoustic wave (SAW) devices with GaAs electronics. Knowledge of the SAW properties of the filmed structure is critical for the optimum design of such devices. In this article, the measurements of the velocity surface, which directly affects the SAW diffraction, on the bare and metallized ZnO/SiO2 or Si3N4/GaAs /001/-cut samples are reported using two different techniques: (1) knife-edge laser probe, (2) line-focus-beam scanning acoustic microscope. Comparisons, such as measurement accuracy and tradeoffs, between the former (dry) and the latter (wet) method are given. It is found that near the group of zone axes (110) propagation direction the autocollimating SAW property of the bare GaAs changes into a noncollimating one for the layered structure, but a reversed phenomenon exists near the group of zone axes (100) direction. The passivation layer of SiO2 or Si3N4 (less than 0.2 micrometer thick) and the metallization layer change the relative velocity but do not significantly affect the velocity surface. On the other hand, the passivation layer reduces the propagation loss by 0.5-1.3 dB/microseconds at 240 MHz depending upon the ZnO film thickness. Our SAW propagation measurements agree well with theorectical calculations. We have also obtained the anisotropy factors for samples with ZnO films of 1.6, 2.8, and 4.0 micrometer thickness. Comparisons concerning the piezoelectric coupling and acoustic loss between dc triode and rf magnetron sputtered ZnO films are provided.

Kim, Yoonkee↗

Dual-temperature acoustic levitation and sample transport apparatus

The properties of a dual-temperature resonant chamber to be used for acoustical levitation and positioning have been theoretically and experimentally studied. The predictions of a first-order dissipationless treatment of the generalized wave equation for an inhomogeneous medium are in close agreement with experimental results for the temperature dependence of the resonant mode spectrum and the acoustic pressure distribution, although the measured magnitude of the pressure variations does not correlate well with the calculated one. Ground-based levitation of low-density samples has been demonstrated at 800 C, where steady-state forces up to 700 dyn were generated.

Trinh, E.↗

Quantifying Feedback from Narrow Line Region Outflows in Nearby Active Galaxies. IV. The Effects of Different Density Estimates on the Ionized Gas Masses and Outflow Rates

Active galactic nuclei (AGN) can launch outflows of ionized gas that may influence galaxy evolution, and quantifying their full impact requires spatially resolved measurements of the gas masses, velocities, and radial extents. We previously reported these quantities for the ionized narrow-line region outflows in six low-redshift AGN, where the gas velocities and extents were determined from Hubble Space Telescope long-slit spectroscopy. However, calculating the gas masses required multicomponent photoionization models to account for radial variations in the gas densities, which span ∼6 orders of magnitude. To simplify this method for larger samples with less spectral coverage, we compare these gas masses with those calculated from techniques in the literature. First, we use a recombination equation with three different estimates for the radial density profiles. These include constant densities, those derived from [S ii], and power-law profiles based on constant values of the ionization parameter (U). Second, we use single-component photoionization models with power-law density profiles based on constant U, and allow U to vary with radius based on the [O iii]/Hβ ratios. We find that assuming a constant density of nH = 10(^2) cm(^−3) overestimates the gas masses for all six outflows, particularly at small radii where the outflow rates peak. The use of [S ii] marginally matches the total gas masses, but also overestimates at small radii. Overall, single-component photoionization models where U varies with radius are able to best match the gas mass and outflow rate profiles when there are insufficient emission lines to construct detailed models.

Mitchell Revalski↗

Mercury biomagnification and the trophic structure of the ichthyofauna from a remote lake in the Brazilian Amazon

The present study assesses mercury biomagnification and the trophic structure of the ichthyofauna from the Puruzinho Lake, Brazilian Amazon. In addition to mercury determination, the investigation comprised the calculation of Trophic Magnification Factor (TMF) and Trophic Magnification Slope (TMS), through the measurements of stable isotopes of carbon (δ{sup 13}C) and nitrogen (δ{sup 15}N) in fish samples. These assessments were executed in two different scenarios, i.e., considering (1) all fish species or (2) only the resident fish (excluding the migratory species). Bottom litter, superficial sediment and seston were the sources used for generating the trophic position (TP) data used in the calculation of the TMF. Samples from 84 fish were analysed, comprising 13 species, which were categorized into four trophic guilds: iliophagous, planktivorous, omnivorous and piscivorous fish. The δ{sup 13}C values pointed to the separation of the ichthyofauna into two groups. One group comprised iliophagous and planktivorous species, which are linked to the food chains of phytoplankton and detritus. The other group was composed by omnivorous and piscivorous fish, which are associated to the trophic webs of phytoplankton, bottom litter, detritus, periphyton, as well as to food chains of igapó (blackwater-flooded Amazonian forests). The TP values suggest that the ichthyofauna from the Puruzinho Lake is part of a short food web, with three well-characterized trophic levels. Mercury concentrations and δ{sup 13}C values point to multiple sources for Hg input and transfer. The similarity in Hg levels and TP values between piscivorous and planktivorous fish suggests a comparable efficiency for the transfer of this metal through pelagic and littoral food chains. Regarding the two abovementioned scenarios, i.e., considering (1) the entire ichthyofauna and (2) only the resident species, the TMF values were 5.25 and 4.49, as well as the TMS values were 0.21 and 0.19, respectively. These findings confirm that Hg biomagnifies through the food web of Puruzinho Lake ichthyofauna. The migratory species did not significantly change mercury biomagnification rate in Puruzinho Lake; however, they may play a relevant role in Hg transport. The biomagnification rate (TMS value) in Puruzinho Lake was higher than the average values for its latitude, being comparable to TMS values of temperate and polar systems (marine and freshwater environments). - Highlights: • Mercury biomagnified in food web of a remote Amazonian lake. • δ{sup 13}C and δ{sup 15}N values suggest multiple Hg sources in food web with 3 trophic levels. • We found similar Hg transfer efficiencies in pelagic and littoral food chains. • Migration may influence the trophic structure assessment performed with δ{sup 15}N. • The migrating species did not significantly alter the biomagnification calculation.

54 ENVIRONMENTAL SCIENCES↗