Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLE POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Enhancements on the Convex Programming Based Powered Descent Guidance Algorithm for Mars Landing

In this paper, we present enhancements on the powered descent guidance algorithm developed for Mars pinpoint landing. The guidance algorithm solves the powered descent minimum fuel trajectory optimization problem via a direct numerical method. Our main contribution is to formulate the trajectory optimization problem, which has nonconvex control constraints, as a finite dimensional convex optimization problem, specifically as a finite dimensional second order cone programming (SOCP) problem. SOCP is a subclass of convex programming, and there are efficient SOCP solvers with deterministic convergence properties. Hence, the resulting guidance algorithm can potentially be implemented onboard a spacecraft for real-time applications. Particularly, this paper discusses the algorithmic improvements obtained by: (i) Using an efficient approach to choose the optimal time-of-flight; (ii) Using a computationally inexpensive way to detect the feasibility/ infeasibility of the problem due to the thrust-to-weight constraint; (iii) Incorporating the rotation rate of the planet into the problem formulation; (iv) Developing additional constraints on the position and velocity to guarantee no-subsurface flight between the time samples of the temporal discretization; (v) Developing a fuel-limited targeting algorithm; (vi) Initial result on developing an onboard table lookup method to obtain almost fuel optimal solutions in real-time.

Guidance↗

Simultaneous Laser Ranging and Communication from an Earth-Based Satellite Laser Ranging Station to the Lunar Reconnaissance Orbiter in Lunar Orbit

We report a free space laser communication experiment from the satellite laser ranging (SLR) station at NASA Goddard Space Flight Center (GSFC) to the Lunar Reconnaissance Orbiter (LRO) in lunar orbit through the on board one-way Laser Ranging (LR) receiver. Pseudo random data and sample image files were transmitted to LRO using a 4096-ary pulse position modulation (PPM) signal format. Reed-Solomon forward error correction codes were used to achieve error free data transmission at a moderate coding overhead rate. The signal fading due to the atmosphere effect was measured and the coding gain could be estimated.

fee-space optical communication↗

Hygroscopicity Evaluation of Halide Scintillators

A collaborative study of relative hygroscopicity of anhydrous halide scintillators grown at various laboratories is presented. We have developed a technique to evaluate moisture sensitivity of both raw materials and grown crystals, in which the moisture absorption rate is measured using a gravimetric analysis. Degradation of the scintillation performance was investigated by recording gamma-ray spectra and monitoring the photopeak position, count rate and energy resolution. The accompanying physical degradation of the samples exposed to ambient atmosphere was photographically recorded as well. The results were compared with ben

Zhuravleva, M↗

Super resolution for magneto-optical microscopy

Sub-diffraction limited magneto-optical microscopy, such as Kerr or Faraday effect microscopy, provide many advantages to fields of science and technology for measuring, or imaging, the magnetization structures and magnetization domains of materials. Disclosed is a method and system for performing sub-diffraction limited magneto-optic microscopy. The method includes positioning a microlens or microlens layer relative to a surface of a sample to image the surface of the sample, forming a photonic nanojet to probe the surface of the sample, and receiving light reflected by the surface of the sample or transmitted through the sample at an imaging sensor. The methods and associated systems and devices enable sub-diffraction limited imaging of magnetic domains at resolutions 2 to 8 times the classical diffraction limit.

te Velthuis, Suzanne Gabriëlle Everdine↗

The surface chemical composition of lunar samples and its significance for optical properties

The surface Fe, Ti, Ca, and Si concentrations in a variety of soil and rock samples from all the Apollo sites are determined using an Auger spectrometer plus a single-pass cylindrical-mirror analyzer with a standard 15-stage BeCu electron multiplier. It is found that there are no great differences between the surface and bulk concentrations of any of the four elements in the rock samples, but the surface Fe and Ti concentrations in soil samples are higher than the bulk concentrations. Results are also reported for solar-wind simulation experiments in which a pulverized rock sample was bombarded with 2-keV alpha-particles corresponding to about a 30,000-yr dose of the solar-wind proton component. These results indicate that the chemical change induced on the surface of a rock powder by positive-ion bombardment is similar to the change from bulk to surface chemical composition in lunar soil samples. A clear correlation is observed between the surface Fe concentration and albedo of the soil samples.

Gold, T.↗

Stabilization of positive charge on polytetrafluoroethylene electret films treated with titanium-tetrachloride vapor

The surface of polytetrafluoroethylene films was treated with titanium-tetrachloride vapor. The treatment was carried out in a flow reactor by means of molecular-layer deposition, a method from the arsenal of chemical nanotechnology. X-ray photoelectron spectroscopy reveals that such a treatment results in considerable changes in the chemical composition at and near the surface of the fluoropolymer film. Both, defluorination and oxidation of the surface were observed. At the same time, samples treated with titanium tetrachloride show a significant enhancement in the thermal stability of the positive homocharge. The thermally stimulated surface-potential-decay curves were observed to shift to higher temperatures by more than 100 deg. C

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High temperature neutron diffraction investigation of U 3 Si 2

The U-Si system is actively undergoing studies due to its promise as a component of an accident tolerant nuclear fuel. In this work, the crystal structure of the U 3 Si 2 compound in the U-Si system was investigated as a function of temperature from room temperature to 1298 K for a sample of approximately 42.02 at.% Si composition and 1373 K for a sample with approximately 42.10 at.% Si using high temperature time-of-flight neutron diffraction on the High-Pressure Preferred Orientation (HIPPO) diffractometer at Los Alamos Neutron Science Center (LANSCE). The simultaneous Rietveld refinement of five histograms from the five HIPPO detector backs (40°, 60°, 90°, 120°, and 145°) provided datasets for the lattice parameters, anisotropic atomic displacement parameters, and atomic positions as a function of temperature. To explore the possibility of a homogeneity range, two sample compositions were analyzed, a 40.02 at.% Si (near stoichiometric) and a potentially hyperstoichiometric (40.10 at.% Si) sample. While minor differences in the anisotropic atomic displacement parameters between the two samples were observed, over the entire investigated temperature range no additional phases were found indicative of a single phase sample and the ability of the U 3 Si 2 compound to accommodate nonstoichiometry, suggesting that the U 3 Si 2 compound is not a line compound confirming previous determinations. However, the differences observed in the average coefficient of linear thermal expansion identified between the two compositions warrant future investigation.

36 MATERIALS SCIENCE↗

A design for large-area fast photo-detectors with transmission-line readout and waveform sampling.

We present a preliminary design and the results of simulation for a photo-detector module to be used in applications requiring the coverage of areas of many square meters with time resolutions less than 10 picoseconds and position resolutions of less than a millimeter for charged particles. The source of light is Cherenkov light in a radiator/window; the amplification is provided by panels of micro-pores functionalized to act as microchannel plates (MCPs). The good time and position resolution stems from the use of an array of parallel 50 Omega transmission lines (strips) as the collecting anodes. The anode strips feed multi-GS/sec sampling chips which digitize the pulse waveform at each end of the strip, allowing a measurement of the time from the average of the two ends, and a 2-dimensional position measurement from the difference of times on a strip, and, in the orthogonal direction, the strip number, or a centroid of the charges deposited on adjacent strips. The module design is constructed so that large areas can be 'tiled' by an array of modules.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comparing Bacterial Community Composition between Healthy and White Plague-Like Disease States in Orbicella annularis Using PhyloChip™ G3 Microarrays

Coral disease is a global problem. Diseases are typically named or described based on macroscopic changes, but broad signs of coral distress such as tissue loss or discoloration are unlikely to be specific to a particular pathogen. For example, there appear to be multiple diseases that manifest the rapid tissue loss that characterizes ‘white plague.’ PhyloChip™ G3 microarrays were used to compare the bacterial community composition of both healthy and white plague-like diseased corals. Samples of lobed star coral (Orbicella annularis, formerly of the genus Montastraea [1]) were collected from two geographically distinct areas, Dry Tortugas National Park and Virgin Islands National Park, to determine if there were biogeographic differences between the diseases. In fact, all diseased samples clustered together, however there was no consistent link to Aurantimonas coralicida, which has been described as the causative agent of white plague type II. The microarrays revealed a large amount of bacterial heterogeneity within the healthy corals and less diversity in the diseased corals. Gram-positive bacterial groups (Actinobacteria, Firmicutes) comprised a greater proportion of the operational taxonomic units (OTUs) unique to healthy samples. Diseased samples were enriched in OTUs from the families Corynebacteriaceae, Lachnospiraceae, Rhodobacteraceae, and Streptococcaceae. Much previous coral disease work has used clone libraries, which seem to be methodologically biased toward recovery of Gram-negative bacterial sequences and may therefore have missed the importance of Gram-positive groups. The PhyloChip™data presented here provide a broader characterization of the bacterial community changes that occur within Orbicella annularis during the shift from a healthy to diseased state.

59 BASIC BIOLOGICAL SCIENCES↗

The Radio Fundamental Catalogue. I. Astrometry

We present the all-sky catalogue of absolute positions and estimates of correlated flux density of 21,942 compact radio sources determined from processing interferometric visibility data of virtually all VLBI observing sessions at 2 to 23~GHz from 72 programs suitable for absolute astrometry collected for 30 years. We used a novel technique of generation of a dataset of fused observables that allowed us to incorporate all available data in our analysis. The catalogue is the most complete and most precise to date. It forms the foundation and reference for positional astronomy, space geodesy, space navigation, population analysis of active galactic nuclei (AGNs), and provides calibrators for phase-referencing for differential astrometry and VLBI astrophysical observations. Its accuracy was evaluated through a detailed accounting systematic errors, rigorous decimation tests, comparison of different datasets, and comparison with other catalogues. The catalogue samples preferentially the AGNs with a strong contemporary parsec-scale synchrotron emission. Its milliarcsecond level positional accuracy allows association of these AGNs with detections in a wide range of the electromagnetic spectrum from low-frequency radio to gamma-rays and high energy neutrinos. We describe the innovative data processing and calibration technique in full detail, report the in depth analysis of random and systematic positional errors, and provide the list of associations with large surveys at different wavelengths.

Astronomy↗

Magnetic microparticle-based multimer detection system for the detection of prion oligomers in sheep

Transmissible spongiform encephalopathies (TSEs) are zoonotic fatal neurodegenerative diseases in animals and humans. TSEs are commonly known as bovine spongiform encephalopathy in cattle, scrapie in sheep and goats, chronic wasting disease in cervids, and Creutzfeldt–Jakob disease in humans. The putative transmissible agents are infectious prion proteins (PrPSc), which are formed by the conversion of the normal prion protein on the glycoprotein cell surface in the presence of other PrPSc. Reports of the transmission of TSEs through blood raised considerable concern about the safety of blood and blood products. To address this issue, many laboratories attempted to develop a sensitive and accurate blood diagnostic test to detect PrPSc. Previously, we reported that, compared to normal controls, the multimer detection system (MDS) was more efficient in detecting PrPSc in infected hamster brain homogenate, mouse plasma spiked with purified PrPSc from scrapie mouse brain, and scrapie-infected hamster plasmas. MDS differentiates prion multimers from the cellular monomer through the multimeric expression of epitopes on prion multimers, in contrast to the monomeric form. In this study, MDS detected PrPSc in plasma samples from scrapie-infected sheep expressing clinical symptoms, demonstrating 100% sensitivity and specificity in these samples. Plasma samples from asymptomatic lambs at the preclinical stage (8-month-old naturally infected offspring of scrapie-infected parents expressing a highly susceptible genotype) tested positive with 50% sensitivity and 100% specificity. In the first of two coded analyses using clinical scrapie-infected sheep and normal healthy samples, MDS successfully identified all but one of the clinical samples with 92% sensitivity and 100% specificity. Similar results were obtained in the second coded analysis using preclinical samples. MDS again successfully identified all but one of the samples with 87% sensitivity and 100% specificity. The false-negative sample was subjected to a protease pretreatment. In conclusion, MDS could accurately detect scrapie in plasma samples at both preclinical and clinical stages. From these studies, we conclude that MDS could be a promising tool for the early diagnosis of TSEs from blood samples.

59 BASIC BIOLOGICAL SCIENCES↗

Antineutrino Physics at MINOS

We present two new measurements of antineutrino properties based on a data sample corresponding to 3.2x10{sup 20} protons-on-target, exploiting MINOS' unique ability to distinguish positive and negative muons and thus separate charged current neutrino and antineutrino interactions event-by-event. The first measurement takes advantage of the 6% antineutrino component of the NuMI neutrino beam to measure antineutrino oscillations between the near and far detectors. We observe 42 events at the far detector with an expectation of 58.3{+-}7.6(stat.){+-}3.6(syst.) assuming CPT-conserving oscillations, excluding (5.0<{delta}m-bar{sup 2}<81)x10{sup -3}eV{sup 2} at 90% confidence at maximal mixing. We also present a search for neutrino-antineutrino transitions {nu}{sub mgr}{yields}{nu}-bar{sub {mu}}, which would result in an excess of antineutrino events in the Far Detector relative to the rate expected from the intrinsic antineutrino component in the neutrino beam. We observe no excess and set a limit of 0.026 on the transition probability at 90% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Tile-Based Fisher Ratio Analysis of Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry (GC × GC – TOFMS) Data using a Null Distribution Approach

Multi-dimensional chromatographic instrumentation produces information-rich, and chemically complex data containing meaningful chemical signals and/or chemical patterns. Two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS) is a prominent instrumental platform that has been applied extensively for discovery-based experimentation, where samples are sufficiently volatile or amenable to derivatization. Use of GC × GC – TOFMS and associated data analysis strategies aim to uncover meaningful chemical signals or chemical patterns. However, for complex samples, meaningful chemical information is often buried in a background of less meaningful chemical signal and noise. In this report, we utilize the tile-based F-ratio software in concert with the standard addition method by spiking non-native chemicals into a diesel fuel matrix at low concentrations. While the previous work studied the concentration range of 100-1000 ppm, the current study focuses on the 0 ppm to 100 ppm analyte spike range. This study demonstrates the sensitivity and selectivity of the tile-based F-ratio software for discovery of true positives in the non-targeted analysis of a chemically complex and analytically challenging sample matrix. By exploring the low concentration spike levels, we gain a better understanding of the limit of detection (LOD) of the tile-based F-ratio software with GC × GC – TOFMS data.

Parsons, Brendon A.↗

Deployment of a Fast-GCMS System to Measure C2 to C5 Carbonyls, Methanol and Ethanol Aboard Aircraft

Through funding of this proposal, a fast response gas chromatograph/mass spectrometer (FGCMS) instrument to measure less than or equal to C4 carbonyl compounds and methanol was developed for the NASA GTE TRACE-P (Global Tropospheric Experiment, Transport And Chemical Evolution Over The Pacific) mission. The system consists of four major components: sample inlet, preconcentration system, gas chromatograph (GC), and detector. The preconcentration system is a custom-built cryogen-conservative system. The GC is a compact, custom-built unit that can be temperature programmed and rapidly cooled. Detection is accomplished with an Agilent Technologies 5973 mass spectrometer. The FGCMS instrument provides positive identification because the compounds are chromatographically separated and mass selected. During TRACE-P, a sample was analyzed every 5 minutes. The FGCMS limit of detection was between 5 and 75 pptv, depending on the compound. The entire instrument package is contained in a standard NASA instrument rack (106 cm x 61 cm x 135 cm), consumes less than 1200 watts and is fully automated with LabViEW 6i. Methods were developed or producing highly accurate gas phase standards for the target compounds and for testing the system in the presence of potential interferents. This report presents data on these tests and on the general overall performance of the system in the laboratory and aboard the DC-8 aircraft during the mission. Vertical profiles for acetaldehyde, methanol, acetone, propanal, methyl ethyl ketone, and butanal from FGCMS data collected over the entire mission are also presented.

Apel, Eric C.↗

Air, surface, and wastewater surveillance of SARS-CoV-2; a multimodal evaluation of COVID-19 detection in a built environment

Environmental surveillance of infectious organisms holds tremendous promise to reduce human-to-human transmission in indoor spaces through early detection. In this study we determined the applicability and limitations of wastewater, indoor high-touch surfaces, in-room air, and rooftop exhaust air sampling methods for detecting SARS-CoV-2 in a real world building occupied by residents recently diagnosed with COVID-19. We concurrently examined the results of three 24-hour environmental surveillance techniques, indoor surface sampling, exhaust air sampling and wastewater surveillance, to the known daily census fluctuations in a COVID-19 isolation dormitory. Additionally, we assessed the ability of aerosol samplers placed in the large volume lobby to detect SARS-CoV-2 multiple times per day. Our research reveals an increase in the number of individuals confirmed positive with COVID-19 as well as their estimated human viral load to be associated with statistically significant increases in viral loads detected in rooftop exhaust aerosol samples (p = 0.0413), wastewater samples (p = 0.0323,), and indoor high-touch surfaces (p < 0.001)). We also report that the viral load detected in lobby aerosol samples was statistically higher in samples collected during presence of occupants whose COVID-19 diagnostic tests were confirmed positive via qPCR compared to periods when the lobby was occupied by either contact-traced (suspected positive) individuals or during unoccupied periods (p = 0.0314 and <2e–16). We conclude that each daily (24h) surveillance method, rooftop exhaust air, indoor high-touch surfaces, and wastewater, provide useful detection signals for building owner/operator(s). Furthermore, we demonstrate that exhaust air sampling can provide spatially resolved signals based upon ventilation exhaust zones. Additionally, we find that indoor lobby air sampling can provide temporally resolved signals useful during short duration sampling periods (e.g., 2-4 hours) even with intermittent occupancy by occupants diagnosed with COVID-19.

60 APPLIED LIFE SCIENCES↗

Examining the self-interaction of dark matter through central cluster galaxy offsets

ABSTRACT While collisionless cold dark matter models have been largely successful in explaining a wide range of observational data, some tensions still exist, and it remains possible that dark matter possesses a non-negligible level of self-interactions. In this paper, we investigate a possible observable consequence of self-interacting dark matter: offsets between the central galaxy and the centre of mass of its parent halo. We examine 23 relaxed galaxy clusters in a redshift range of 0.1–0.3 drawn from clusters in the Dark Energy Survey and the Sloan Digital Sky Survey which have archival Chandra X-ray data of sufficient depth for centre and relaxation determination. We find that most clusters in our sample show non-zero offsets between the X-ray centre, taken to be the centroid within the cluster core, and the central galaxy position. All of the measured offsets are larger, typically by an order of magnitude, than the uncertainty in the X-ray position due to Poisson noise. In all but six clusters, the measured offsets are also larger than the estimated, combined astrometric uncertainties in the X-ray and optical positions. A more conservative cut on concentration to select relaxed clusters marginally reduces but does not eliminate the observed offset. With our more conservative sample, we find an estimated median X-ray to central galaxy offset of $\mu = 6.0 ^{+ 1.4}_{- 1.5}$ kpc. Comparing to recent simulations, this distribution of offsets is consistent with some level of dark matter self-interaction, though further simulation work is needed to place constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

SPRUCE Phospholipid Fatty Acid (PLFA) Abundances, August 2021-June 2022

This data set provides the results for phospholipid fatty acid analysis (PLFA) of peat samples collected from ambient plots in the SPRUCE experiment site, with experimental plot samples still being processed. The samples used to generate this data set were collected on 2021-08-23 and 2022-06-21. This data set includes abundances for groups of lipids indicating total biomass, fungi, Gram-positive bacteria, Gram-negative bacteria, actinomycetes, and anaerobic bacteria. This data set contains one file in comma separate (*.csv) format. Samples: On each sampling date, cores extending to 200 cm were collected and subsampled at 10 cm intervals from 0 and 100 cm and 25 cm intervals below 100 cm depth in Plot 7 and 21. During the lipid extraction procedure, samples were pooled into the following depth increments in order to obtain sufficient material to achieve adequate lipid yield: 0-10, 10-20, 20-30, 30-50, 50-100, and 100-150, and 150-200 cm.

actinomycetes↗

Cautionary Notes on Cosmogenic W-182 and Other Nuclei in Lunar Samples

Leya et al. (2000) showed that neutron capture on Ta-181 results in a production rate of Ta-182 (decays with a half-life of 114 days to W-182) sufficiently high to cause significant shifts in W-182 abundances considering the neutron fluences due to the cosmic ray cascade that were known to occur near the lunar surface. Leya et al. concluded that this cosmogenic production of W-182 may explain the large positive epsilon(sub W-182) values that Lee et al. (1997) had reported in some lunar samples rather than being produced from decay of now extinct Hf-182 (bar tau = 13 x 10(exp 6) yr). If the large range in epsilon(sub W-182) of lunar samples (0 to +11 in whole rock samples) was due to decay of now extinct Hf-182, it would require a very early time of formation and differentiation of the lunar crust-mantle system (with high Hf/W ratios) during the earliest stages of Earth s accretion. This result was both surprising and difficult to understand. The ability to explain these results by a more plausible mechanism is therefore very attractive. In a recent report Lee et al. (2002) showed that there were excesses of W-182 and that epsilon(sub W-182) was correlated with the Ta/W ratios in the mineral phases of individual lunar rock samples. This is in accord with W-182 variations in lunar samples being produced by cosmic-ray induced neutron capture on Ta-182.

Yin, Qingzhu↗