Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Moving Toward Focal Therapy in Prostate Cancer: Dual-Isotope Permanent Seed Implants as a Possible Solution

Purpose: To compare the ability of single- and dual-isotope prostate seed implants to escalate biologically effective dose (BED) to foci of disease while reducing prescription dose to the prostate. Methods and Materials: Nine plans, using {sup 125}I, {sup 103}Pd, and {sup 131}Cs alone and in combination were created retrospectively for 2 patients. Ultrasound and MRI/MRS datasets were used for treatment planning. Voxel-by-voxel BED was calculated for single- and dual-isotope plans. Equivalent uniform BED (EUBED) was used to compare plans. The MRS-positive planning target volumes (PTV{sub i}) were delineated along with PTV (prostate + 5 mm), rectum, and urethra. Single-isotope implants, prescribed to conventional doses, were generated to achieve good PTV coverage. The PTV{sub i} were prospectively used to generate implants using mixtures of isotopes. For mixed-radioisotope implants, we also explored the impact on EUBED of lowering prescription doses by 15%. Results: The EUBED of PTV{sub i} in the setting of primary {sup 125}I implant increased 20-66% when {sup 103}Pd and {sup 131}Cs were used compared with {sup 125}I boost. Decreasing prescription dose by 15% in mixed-isotope implants results in a potential 10% reduction in urethral EUBED with preservation of PTV coverage while still boosting PTV{sub i} (up to 80%). When radiobiologic parameters corresponding to more-aggressive disease are assigned to foci, faster-decaying isotopes used in mixed implants have the potential to preserve the equivalent biological effect of mono-isotope implants considering less-aggressive disease distributed in the entire prostate. Conclusions: This is a hypothesis-generating study proposing a treatment paradigm that could be the middle ground between whole-gland irradiation and focal-only treatment. The use of two isotopes concurrent with decreasing the minimal peripheral dose is shown to increase EUBED of selected subvolumes while preserving the therapeutic effect at the level of the gland.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Conducting Well-Controlled Ion Irradiations To Understand Neutron Irradiation Effects In Materials

A firm understanding of the effect of radiation on materials is required to develop predictive models of materials behavior in-reactor and provide a foundation for creating new, more radiation-tolerant materials. Ion irradiation can serve this purpose for nuclear reactor components and is becoming a key element of materials development for advanced nuclear reactors. Ion irradiations can be conducted quickly, at low cost, and with precise control over irradiation temperature, temperature uniformity, dose rate, dose uniformity and total dose. During proton irradiations the 2{sigma}(twice the standard deviation) of the sample temperature is generally below {approx}7 deg. C, the dose rate variation {approx}3%, the dose uncertainty {approx}3%, and there is an excellent temperature and dose uniformity across the irradiated area. In this article, we describe the experimental setup and irradiation procedure used to conduct well-controlled ion irradiations at the University of Michigan.

07 ISOTOPE AND RADIATION SOURCES↗

An Overview Of Activation Analysis Techniques And Applications

Activation analysis can be performed using three different techniques, namely: activation with neutrons, with high-energy photons, and with charged particles. The different features as well as the advantages and drawbacks of these separate techniques will be discussed in this paper. During exposure radionuclides are produced in the activated sample and, the turn, the radiation emitted during radioactive decay (photons in the most cases) is measured with appropriate spectrometers. By evaluating the produced spectra, the elemental components of the activated material can be quantitatively ascertained. Through means of activation analysis, basically any kind of material can be studied. And frequently the sample can be analysed as is(instrumentally without complicated radiochemical separation steps), and in favourable cases, the analysis may be conducted non-destructively, i.e. without removing pieces of the interrogated sample. Several common applications will be discussed in this paper.

07 ISOTOPE AND RADIATION SOURCES↗

Analysis of the effect of heated jet flow on the far field radiation from a noise source

The influence on jet noise radiation of the interaction with the heated moving flow of a parallel twin jet is investigated. An analytical model of jet shielding is developed which consists of the sound field emitted from a stationary, discrete frequency point source impinging on a cylinder of locally parallel flow. The zones in which the various shielding mechanisms dominate are analyzed using the model. The effects of parameters such as jet temperature and flow speed are examined. It is found that the results obtained using the model are comparable to the experimental results for a point noise source impinging on a subsonic isothermal air jet.

Gerhold, C.↗

A tuneable ultra-compact high-power, ultra-short pulsed, bright gamma-ray source based on bremsstrahlung radiation from laser-plasma accelerated electrons

The laser driven plasma wakefield accelerator is a very compact source of high energy electrons. When the quasi-monoenergetic beam from these accelerators passes through dense material, high energy bremsstrahlung photons are emitted in a collimated beam with high flux. We show how a source based on this emission process can produce more than 10{sup 9} photons per pulse with a mean energy of 10 MeV. We present experimental results that show the feasibility of this method of producing high energy photons and compare the experimental results with GEANT4 Montecarlo simulations, which also give the scaling required to evaluate its suitability as method to produce radioisotopes via photo-nuclear reactions or for imaging applications.

07 ISOTOPE AND RADIATION SOURCES↗

High-Resolution X-ray Microprobe Using a Spatial Filter and Its Application to Micro-XAFS Measurements

An x-ray microprobe system with total-reflection mirror optics for trace element analysis has been developed at beamline 37XU of SPring-8. To achieve sub-microprobe, a spatial filter has been installed downstream of a monochromator. Focusing tests have been performed in the x-ray energy range of 6-14 keV. A focused beam size of 0.83 {mu}m(V)x1.35 {mu}m(H) has been obtained at an x-ray energy of 10 keV, and using a spatial filter in the horizontal direction, the beam size is down to 0.84 {mu}m. Micro-x-ray absorption fine structure (XAFS) spectroscopy of submicrometer particles has been done by utilizing the total-reflection mirror optics. It was clearly observed from the nickel K-edge XAFS spectra that the oxidation state of nickel was a mixture of metal and oxide even in the single submicrometer particle.

07 ISOTOPE AND RADIATION SOURCES↗

Development of an X-ray Micro-Laminography System at SPring-8

An x-ray micro-laminography system has been developed at SPring-8 and applied to measurements of planar objects that cannot be observed by x-ray computed tomography. To reconstruct a sectional image parallel to the planar surface, a filtered back-projection technique considering the inclination angle of a rotational axis was developed. Experimental conditions suitable for laminography measurements in this system were investigated. Spatial resolution in the reconstructed plane was almost determined by the detector resolution, while the spatial resolution perpendicular to the planar surface tended to be worse by the artifacts inherent of the laminographic scanning and reconstruction method. A laminated test sample was clearly observed in three dimensions.

07 ISOTOPE AND RADIATION SOURCES↗

On the polarization of resonantly scattered emission lines - 1. Emission and absorption coefficients in an anisotropic radiation field

Source functions and absorptions coefficients for polarized radiation in a given ansiotropic radiation field are calculated for a variety of permitted electric dipole transitions in the L-S coupling limit. Collisional, radiative and magnetic mixing of the ground sublevels are all considered. The polarization of the self-consistent, emergent radiation field is computed, using an anisotropic escape probability formalism to treat the radiative transfer. It is found that the radiative mixing can enhance the polarization for transitions with large angular momentum, and degrees of polarization less than or approximately 10 per cent are obtained for transitions with small angular momentum.

Lee, H. -W.↗

Cylindrical periodic surface lattice as a metadielectric: Concept of a surface-field Cherenkov source of coherent radiation

A two-dimensional (2D), cylindrical, periodic surface lattice (PSL) forming a surface field cavity is considered. The lattice is created by introducing 2D periodic perturbations on the inner surface of a cylindrical waveguide. The PSL facilitates a resonant coupling of the surface and near cutoff volume fields, leading to the formation of a high-Q cavity eigenmode. The cavity eigenmode is described and investigated using a modal approach, considering the model of a cylindrical waveguide partially loaded with a metadielectric. By using a PSL-based cavity, the concept of a high-power, 0.2-THz Cherenkov source is developed. It is shown that if the PSL satisfies certain defined conditions, single-mode operation is observed.

36 MATERIALS SCIENCE↗

Collimator of multiple plates with axially aligned identical random arrays of apertures

A collimator is disclosed for examining the spatial location of distant sources of radiation and for imaging by projection, small, near sources of radiation. The collimator consists of a plurality of plates, all of which are pierced with an identical random array of apertures. The plates are mounted perpendicular to a common axis, with like apertures on consecutive plates axially aligned so as to form radiation channels parallel to the common axis. For near sources, the collimator is interposed between the source and a radiation detector and is translated perpendicular to the common axis so as to project radiation traveling parallel to the common axis incident to the detector. For far sources the collimator is scanned by rotating it in elevation and azimuth with a detector to determine the angular distribution of the radiation from the source.

Hoover, R. B.↗

Measurement of the mass attenuation coefficient from 81 keV to 1333 keV for elemental materials Al, Cu and Pb

The mass attenuation coefficients (μ/ρ) for 3 high purity elemental materials Al, Cu and Pb were measured in the γ-ray energy range from 81 keV up to 1333 keV using {sup 22}Na, {sup 60}Co {sup 133}Ba and {sup 133}Cs as sources of gamma radiation. Well shielded detector (NaI (Tl) semiconductor detector) was used to measure the intensity of the transmitted beam. The measurements were made under condition of good geometry, assuring that any photon absorbed or deflected appreciably does not reach the detector. The measured values are compared with the theoretical ones obtained by Seltzer (1993).

07 ISOTOPE AND RADIATION SOURCES↗

Influence of boundary conditions on the radiation emitted by an accelerated source

We analyze how the radiation emitted by an accelerated source minimally coupled to a massless real scalar field is influenced by the boundary conditions imposed on the field. We find that the response rate of the accelerated source in the presence of nearby boundaries parallel to the direction of the source's motion can be suppressed or enhanced depending on whether Dirichlet or Neumann boundary conditions are imposed on the field. We conclude that the response rate strongly depends on the kind of boundary conditions imposed, just as the sign of the Casimir force depends on the boundary conditions imposed on the field.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Survey of Dust Production in Pebble Bed Reactors Cores

Graphite dust produced via mechanical wear from the pebbles in a pebble bed reactor is an area of concern for licensing. Both the German pebble bed reactors produced graphite dust that contained activated elements. These activation products constitute an additional source term of radiation and must be taken under consideration during the conduct of accident analysis of the design. This paper discusses the available literature on graphite dust production and measurements in pebble bed reactors. Limited data is available on the graphite dust produced from the AVR and THTR-300 pebble bed reactors. Experiments that have been performed on wear of graphite in pebble-bed-like conditions are reviewed. The calculation of contact forces, which are a key driving mechanism for dust in the reactor, are also included. In addition, prior graphite dust predictions are examined, and future areas of research are identified.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗