Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “READOUT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Reminiscence of Classical Chaos in Driven Transmons

Transmon qubits are ubiquitously used in superconducting quantum information processor architectures. Strong drives are required to realize fast, high-fidelity, gates and measurements, including parametrically activated processes. Here, we show that even off-resonant drives, in regimes routinely used in experiments, can cause strong modifications to the structure of the transmon spectrum rendering a large part of it chaotic. Accounting for the full nonlinear dynamics of the transmon in a Floquet-Markov formalism, we find that these chaotic states, often neglected through the hypothesis that the anharmonicity is weak, strongly impact the lifetime of the transmon’s computational states. In particular, we observe that chaos-assisted quantum phase slips greatly enhance band dispersions. In the presence of a measurement resonator, we find that approaching chaotic behavior correlates with strong transmon-resonator hybridization, and an average resonator response centered on the bare resonator frequency. These results lead to a photon-number threshold characterizing the appearance of chaos-induced quantum demolition effects during strong-drive operations, such as dispersive qubit readout. The phenomena described here are expected to be present in all circuits based on low-impedance Josephson junctions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal Zeno Dragging for Quantum Control: A Shortcut to Zeno with Action-Based Scheduling Optimization

The quantum Zeno effect asserts that quantum measurements inhibit simultaneous unitary dynamics when the “collapse” events are sufficiently strong and frequent. This applies in the limit of strong continuous measurement or dissipation. It is possible to implement a dissipative control that is known as “Zeno dragging” by dynamically varying the monitored observable, and hence also the eigenstates, which are attractors under Zeno dynamics. This is similar to adiabatic processes, in that the Zeno-dragging fidelity is highest when the rate of eigenstate change is slow compared to the measurement rate. We demonstrate here two theoretical methods for using such dynamics to achieve control of quantum systems. The first, which we shall refer to as “shortcut to Zeno,” is analogous to the shortcuts to adiabaticity (counterdiabatic driving) that are frequently used to accelerate unitary adiabatic evolution. In the second approach, we apply the Chantasri-Dressel-Jordan stochastic action [PRA 88, 042110 (2013)], and demonstrate that the extremal-probability readout paths derived from this are well suited to setting up a Pontryagin-style optimization of the Zeno-dragging schedule. A fundamental contribution of the latter approach is to show that an action suitable for measurement-driven control optimization can be derived quite generally from statistical arguments. Implementing these methods on the Zeno dragging of a qubit, we find that both approaches yield the same solution, namely, that the optimal control is a unitary that matches the motion of the Zeno-monitored eigenstate. We then show that such a solution can be more robust than a unitary-only operation and we comment on solvable generalizations of our qubit example embedded in larger systems. These methods open up new pathways toward systematically developing dynamic control of Zeno subspaces to realize dissipatively stabilized quantum operations. Published by the American Physical Society 2024

Physics↗

Coherence-mediated quantum thermometry in a hybrid circuit quantum electrodynamics architecture

Quantum thermometry plays a critical role in the development of low-temperature sensors and quantum information platforms. Here, in this work, we propose and analyze a hybrid circuit quantum electrodynamics architecture in which a superconducting qubit is dispersively coupled to two distinct bosonic modes: one initialized in a weak coherent state as a phase reference and information buffer and the other coupled to a thermal environment. We show that the qubit serves as a sensitive readout of the probe mode, mapping the interplay between thermal and coherent photon-number fluctuations onto measurable dephasing. This coherence-mediated mechanism enables improved sensitivity to thermal energy fluctuations in the sub-millikelvin regime through Ramsey interferometry. We derive analytic expressions for the probe coherence envelope, compute the quantum Fisher information for temperature estimation, and demonstrate numerically that the presence of a coherent reference enhances the qubit's sensitivity to small changes in thermal photon occupancy. Our results establish a coherence-enabled approach to thermometry and provide a scalable platform for future calorimetric sensing in high-energy physics and quantum metrology.

Zhu, Shaojiang [Fermi National Accelerator Laborat↗

Quantum nanophotonic interface for tin-vacancy centers in thin-film diamond

The negatively charged tin-vacancy center in diamond (SnV − ) is an excellent solid state qubit with optically-addressable transitions and a long electron spin coherence time at elevated (∼1.7 K). However, implementing scalable quantum nodes with high-fidelity optical readout of the electron spin state requires efficient photon emission and collection from the system. Here, in this manuscript, we report a quantum photonic interface for SnV−centers based on one-dimensional photonic crystal cavities fabricated in diamond thin films. Furthermore, we provide a rigorous description of the spontaneous emission dynamics of our system, taking into account individual contributions from both the C and D transitions of the emitter. This allows for determination of Purcell factors per transition and, by extension, the C/D branching ratio SnV− zero phonon line. We observe quality factors up to ~6000 across this sample, and measure up to a 12-fold lifetime reduction, which translates into a Purcell factor of 𝐹 𝐶 =26.2±1.5 for a targeted C transition. By considering the cavity mode polarization alignment with the C and D transition dipole moments, we validate the C/D branching ratio to be 𝜂 BR =0.75±0.01, in line with previous theoretical and experimental findings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of Synchronization between Two Quantum van der Pol Oscillators in Trapped Ions

Synchronization is a hallmark of collective behavior that emerges when nonlinear systems interact, spanning scales from mechanical oscillators to planetary orbits. As a universal phenomenon, it underpins the study of complex systems and has far-reaching technological implications. While classical synchronization has a long and rich history, it has not been observed experimentally between multiple quantum limit-cycle oscillators despite a decade of theoretical investigations. We realize synchronization between two quantum van der Pol oscillators by engineering dissipation in a mixed-isotope trapped-ion quantum simulator. The synchronized state is encoded in a fixed relative phase between the oscillators that is inaccessible to individual measurements and revealed only through joint readout of both oscillators, in stark contrast to the system in the (deterministic) classical limit where synchronization can be observed via individual phase measurements. We further show that the relative phase can be precisely controlled and that the chain of two oscillators can synchronize to an external field, suggesting applications in sensing. Our results provide a promising pathway for studying more complex synchronized quantum dynamics beyond two oscillators, where a theoretical treatment becomes increasingly challenging, and it remains to be understood whether genuinely quantum features persist in such cases.

Liu, Jiarui↗

Optical cycling on thorium monoxide for an improved test of fundamental symmetries

Optical cycling refers to repeated excitation and spontaneous emission on an electronic transition in an atom or molecule. Optical cycling in molecules can enable a wide range of quantum control and readout techniques, but unfortunately it has only been demonstrated on a small class of alkalilike or alkaline-earth-like molecules. Thorium monoxide (ThO), a molecule used in one of the most precise permanent electron electric dipole moment (eEDM) searches (ACME†) [Andreev et al., Nature (London) 562, 355 (2018)], does not fall into this category. In this work, we demonstrate the first optical cycling on this nonconventional class over a range of experimental parameter space, including laser intensity, polarization switching rate, and interaction time. We show that both the 𝐽 = 1 and 𝐽 = 2 rotational levels of ThO molecule are capable of cycling an average of 11(2) photons with a single laser, at scattering rates of 1.9⁢(6) × 10 6 and 2.3⁢(7) × 10 6 s −1 , respectively, before population is lost to other vibronic levels. We outline a scheme to apply this demonstrated optical cycling in an ACME-style eEDM measurement, improving the detection efficiency by over fourfold compared to noncycling fluorescence detection. This would lead to over a twofold enhancement in the statistical sensitivity of the eEDM search. This optical-cycling scheme can be further extended to scatter ∼100 photons, which would enable a wider range of quantum control and sensing using ThO molecules.

Atomic & molecular processes in external fields↗

A scanning CCD detector for powder diffraction measurements

Several different approaches have traditionally been used for detection of X-ray powder diffraction patterns, including area detectors, point detectors and position-sensitive detectors. Each has advantages. This paper discusses use of a low-cost CCD detector attached to a diffractometer arm, where line-by-line readout of the CCD is coupled to continuous motion of the arm. When this type of detector is used and where X-ray optics are employed to focus the source image onto the detector plane both high-resolution and rapid measurements can be performed, with data collection over a complete 2θ range. This is particularly advantageous for synchrotron applications but valuable also for Guinier diffractometer laboratory instruments. Peak resolutions are shown to be moderately better than what can be obtained with a position-sensitive detector and significantly better than with an area detector. Many samples have intrinsically broadened peak shapes for which little improvement in data quality could be obtained with an analyzer-crystal detector. With comparable numbers of modules, these CCD data collection speeds can be close to those with position-sensitive detectors, but without the low-angle asymmetry seen in the latter.

Toby, B. H.↗

Outrunning free radicals in room-temperature macromolecular crystallography

A systematic increase in lifetime is observed in room-temperature protein and virus crystals through the use of reduced exposure times and a fast detector. A significant increase in the lifetime of room-temperature macromolecular crystals is reported through the use of a high-brilliance X-ray beam, reduced exposure times and a fast-readout detector. This is attributed to the ability to collect diffraction data before hydroxyl radicals can propagate through the crystal, fatally disrupting the lattice. Hydroxyl radicals are shown to be trapped in amorphous solutions at 100 K. The trend in crystal lifetime was observed in crystals of a soluble protein (immunoglobulin γ Fc receptor IIIa), a virus (bovine enterovirus serotype 2) and a membrane protein (human A{sub 2A} adenosine G-protein coupled receptor). The observation of a similar effect in all three systems provides clear evidence for a common optimal strategy for room-temperature data collection and will inform the design of future synchrotron beamlines and detectors for macromolecular crystallography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

X-ray Characterization of a Multichannel Smart-Pixel Array Detector

The Voxtel VX-798 is a prototype X-ray pixel array detector (PAD) featuring a silicon sensor photodiode array of 48 x 48 pixels, each 130 mu m x 130 mu m x 520 mu m thick, coupled to a CMOS readout application specific integrated circuit (ASIC). The first synchrotron X-ray characterization of this detector is presented, and its ability to selectively count individual X-rays within two independent arrival time windows, a programmable energy range, and localized to a single pixel is demonstrated. During our first trial run at Argonne National Laboratory's Advance Photon Source, the detector achieved a 60 ns gating time and 700 eV full width at half-maximum energy resolution in agreement with design parameters. Each pixel of the PAD holds two independent digital counters, and the discriminator for X-ray energy features both an upper and lower threshold to window the energy of interest discarding unwanted background. This smart-pixel technology allows energy and time resolution to be set and optimized in software. It is found that the detector linearity follows an isolated dead-time model, implying that megahertz count rates should be possible in each pixel. Measurement of the line and point spread functions showed negligible spatial blurring. When combined with the timing structure of the synchrotron storage ring, it is demonstrated that the area detector can perform both picosecond time-resolved X-ray diffraction and fluorescence spectroscopy measurements.

CMOS ASIC↗

First experimental feasibility study of VIPIC: a custom-made detector for X-ray speckle measurements

The Vertically Integrated Photon Imaging Chip (VIPIC) was custom-designed for X-ray photon correlation spectroscopy, an application in which occupancy per pixel is low but high time resolution is needed. VIPIC operates in a sparsified streaming mode in which each detected photon is immediately read out as a time- and position-stamped event. This event stream can be fed directly to an autocorrelation engine or accumulated to form a conventional image. The detector only delivers non-zero data (sparsified readout), greatly reducing the communications overhead typical of conventional frame-oriented detectors such as charge-coupled devices or conventional hybrid pixel detectors. This feature allows continuous acquisition of data with timescales from microseconds to hours. In this work VIPIC has been used to measure X-ray photon correlation spectroscopy data on polystyrene latex nano-colliodal suspensions in glycerol and on colloidal suspensions of silica spheres in water. Relaxation times of the nano-colloids have been measured for different temperatures. These results demonstrate that VIPIC can operate continuously in the microsecond time frame, while at the same time probing longer timescales.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-energy micrometre-scale pixel direct conversion X-ray detector

The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. Here, the technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.

36 MATERIALS SCIENCE↗

Abridged spectral matrix inversion: parametric fitting of X-ray fluorescence spectra following integrative data reduction

Recent improvements in both X-ray detectors and readout speeds have led to a substantial increase in the volume of X-ray fluorescence data being produced at synchrotron facilities. This in turn results in increased challenges associated with processing and fitting such data, both temporally and computationally. Herein an abridging approach is described that both reduces and partially integrates X-ray fluorescence (XRF) data sets to obtain a fivefold total improvement in processing time with negligible decrease in quality of fitting. The approach is demonstrated using linear least-squares matrix inversion on XRF data with strongly overlapping fluorescent peaks. This approach is applicable to any type of linear algebra based fitting algorithm to fit spectra containing overlapping signals wherein the spectra also contain unimportant (non-characteristic) regions which add little (or no) weight to fitted values, e.g. energy regions in XRF spectra that contain little or no peak information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gaia: segmented germanium detector for high-energy X-ray fluorescence and spectroscopic imaging

We present Gaia, a monolithic array of 96 high-purity germanium pixel detectors integrated with a custom low-noise application-specific integrated circuit (ASIC) and a field-programmable gate array (FPGA)-based data acquisition system. The sensor operates at ∼100 K using a commercial closed-cycle cryocooler, with the in-vacuum electronics thermally isolated from the cold finger to ensure thermal stability. The system demonstrates an average energy resolution of 711 eV at 122 keV, measured using a 57 Co source, and 253 eV at 5.89 keV, measured with 55 Fe across all channels. The readout architecture incorporates a high-performance FPGA paired with a dual-core ARM processor, forming a complete embedded Linux-based computing platform. Communication between the processor and FPGA is handled via memory-mapped I/O, and data are streamed over high-speed gigabit Ethernet. A full-scale 384-pixel Gaia detector, based on this 96-element module, is currently under fabrication.

36 MATERIALS SCIENCE↗

Real-time data processing for serial crystallography experiments

We report the use of streaming data interfaces to perform fully online data processing for serial crystallography experiments, without storing intermediate data on disk. The system produces Bragg reflection intensity measurements suitable for scaling and merging, with a latency of less than 1 s per frame. Our system uses the CrystFEL software in combination with the ASAP::O data framework. In a series of user experiments at PETRA III, frames from a 16 megapixel Dectris EIGER2 X detector were searched for peaks, indexed and integrated at the maximum full-frame readout speed of 133 frames per second. The computational resources required depend on various factors, most significantly the fraction of non-blank frames ('hits'). The average single-thread processing time per frame was 242 ms for blank frames and 455 ms for hits, meaning that a single 96-core computing node was sufficient to keep up with the data, with ample headroom for unexpected throughput reductions. Further significant improvements are expected, for example by binning pixel intensities together to reduce the pixel count. We discuss the implications of real-time data processing on the `data deluge' problem from recent and future photon-science experiments, in particular on calibration requirements, computing access patterns and the need for the preservation of raw data.

47 OTHER INSTRUMENTATION↗

SAD phasing of XFEL data depends critically on the error model

A nonlinear least-squares method for refining a parametric expression describing the estimated errors of reflection intensities in serial crystallographic (SX) data is presented. This approach, which is similar to that used in the rotation method of crystallographic data collection at synchrotrons, propagates error estimates from photon-counting statistics to the merged data. Here, it is demonstrated that the application of this approach to SX data provides better SAD phasing ability, enabling the autobuilding of a protein structure that had previously failed to be built. Estimating the error in the merged reflection intensities requires the understanding and propagation of all of the sources of error arising from the measurements. One type of error, which is well understood, is the counting error introduced when the detector counts X-ray photons. Thus, if other types of random errors (such as readout noise) as well as uncertainties in systematic corrections (such as from X-ray attenuation) are completely understood, they can be propagated along with the counting error, as appropriate. In practice, most software packages propagate as much error as they know how to model and then include error-adjustment terms that scale the error estimates until they explain the variance among the measurements. If this is performed carefully, then during SAD phasing likelihood-based approaches can make optimal use of these error estimates, increasing the chance of a successful structure solution. In serial crystallography, SAD phasing has remained challenging, with the few examples of de novo protein structure solution each requiring many thousands of diffraction patterns. Here, the effects of different methods of treating the error estimates are estimated and it is shown that using a parametric approach that includes terms proportional to the known experimental uncertainty, the reflection intensity and the squared reflection intensity to improve the error estimates can allow SAD phasing even from weak zinc anomalous signal.

59 BASIC BIOLOGICAL SCIENCES↗

Skipper-CCD Output Sensitivity Improvement with a Common Source Cascode Amplifier

A Skipper-CCD output has been traditionally readout in a source follower configuration, also known as common drain, mainly because in this configuration a good compromise between sensitivity, noise and speed is achieved. In this work a different approach is presented: the output transistor is connected in a common source configuration and an external cascode device is added in series, obtaining a voltage gain higher than unity without increasing significantly the parasitic capacitance due to Miller effect and thus increasing the obtained voltage per electron of charge. The proposed output stage improves the sensitivity 3.4 times when compared with the traditionally used stage while keeping almost the same equivalent noise charge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

International Cyber Incident Repository System: Information Sharing on a Global Scale

According to the 2016 Internet Security Threat Report, the largest number of cyber attacks were recorded last year (2015), reaching a total of 430 million incidents throughout the world. As the number of cyber incidents increases, the need for information and intelligence sharing increases, as well. This fairly large increase in cyber incidents is driving the need for an international cyber incident data reporting system. The goal of the cyber incident reporting system is to make available shared and collected information about cyber events among participating international parties. In its 2014 report, Insurance Industry Working Session Readout Report-Insurance for CyberRelated Critical Infrastructure Loss: Key Issues, on the outcomes of a working session on cyber insurance, the U.S. Department of Homeland Security observed that “many participants cited the need for a secure method through which organizations could pool and share cyber incident information” and noted that one underwriter emphasized the importance of internationally harmonized data taxonomies. This cyber incident data reporting system could benefit all nations that take part in reporting incidents to provide a more common operating picture. In addition, this reporting system could allow for trending and anticipated attacks and could potentially benefit participating members by enabling them to get in front of potential attacks. The purpose of this paper is to identify options for consideration for such a system in fostering cooperative cyber defense.

Joyce, Amanda L.↗

Discriminating Quantum States with Quantum Machine Learning

Quantum machine learning (QML) algorithms have obtained great relevance in the machine learning (ML) field due to the promise of quantum speedups when performing basic linear algebra subroutines (BLAS), a fundamental element in most ML algorithms. By making use of BLAS operations, we propose, implement and analyze a quantum k-means (qk-means) algorithm with a low time complexity of O(NKlog(D)I/C) to apply it to the fundamental problem of discriminating quantum states at readout. Discriminating quantum states allows the identification of quantum states |0⟩ and |1⟩ from low-level in-phase and quadrature signal (IQ) data, and can be done using custom ML models. In order to reduce dependency on a classical computer, we use the qk-means to perform state discrimination on the IBMQ Bogota device and managed to find assignment fidelities of up to 98.7% that were only marginally lower than that of the k-means algorithm. We also performed a cross-talk benchmark on the quantum device by applying both algorithms to perform state discrimination on a combination of quantum states and using Pearson Correlation coefficients and assignment fidelities of discrimination results to conclude on the presence of cross-talk on qubits. Evidence shows cross-talk in the (1, 2) and (2, 3) neighboring qubit couples for the analyzed device.

Quiroga, David↗