Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Protection & Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Improved Controller Design of Grid Friendly™ Appliances for Primary Frequency Response

The Grid Friendly$^\textrm{TM}$ Appliance~(GFA) controller, developed at Pacific Northwest National Laboratory, can autonomously switch off the appliances by detecting the under-frequency events. In this paper, the impacts of curtailing frequency threshold on the performance of frequency responsive GFAs are carefully analyzed first. The current method of selecting curtailing frequency thresholds for GFAs is found to be insufficient to guarantee the desired performance especially when the frequency deviation is shallow. In addition, the power reduction of online GFAs could be so excessive that it can even impact the system response negatively. As a remedy to the deficiency of the current controller design, a different way of selecting curtailing frequency thresholds is proposed to ensure the effectiveness of GFAs in frequency protection. Moreover, it is also proposed to introduce a supervisor at each distribution feeder to monitor the curtailing frequency thresholds of online GFAs and take corrective actions if necessary.

Lian, Jianming↗

PLEXUS: A Pattern-Oriented Runtime System Architecture for Resilient Extreme-Scale High-Performance Computing Systems

For high-performance computing (HPC) system designers and users, meeting the myriad challenges of next-generation exascale supercomputing systems requires rethinking their approach to application and system software design. Among these challenges, providing resiliency and stability to the scientific applications in the presence of high fault rates requires new approaches to software architecture and design. As HPC systems become increasingly complex, they require intricate solutions for detection and mitigation for various modes of faults and errors that occur in these large-scale systems, as well as solutions for failure recovery. These resiliency solutions often interact with and affect other system properties, including application scalability, power and energy efficiency. Therefore, resilience solutions for HPC systems must be thoughtfully engineered and deployed.In previous work, we developed the concept of resilience design patterns, which consist of templated solutions based on well-established techniques for detection, mitigation and recovery. In this paper, we use these patterns as the foundation to propose new approaches to designing runtime systems for HPC systems. The instantiation of these patterns within a runtime system enables flexible and adaptable end-to-end resiliency solutions for HPC environments. The paper describes the architecture of the runtime system, named Plexus, and the strategies for dynamically composing and adapting pattern instances under runtime control. This runtime-based approach enables actively balancing the cost-benefit trade-off between performance overhead and protection coverage of the resilience solutions. Based on a prototype implementation of PLEXUS, we demonstrate the resiliency and performance gains achieved by the pattern-based runtime system for a parallel linear solver application.

Hukerikar, Saurabh↗

SU-D-201-04: Evaluation of Elekta Agility MLC Performance Using Statistical Process Control

Purpose: to evaluate the performance and stability of the Elekta Agility MLC model using an automated quality control (QC) test in combination with statistical process control tools. Methods: Leaf positions were collected daily for 11 Elekta units over 5–19 months using the automated QC test, which analyzes 23 MV images to determine the location of MLC leaves relative to the radiation isocenter. The leaf positions are measured at 5 nominal positions, and images are acquired at collimator 0° and 180° to capture all MLC leaves in the field-of-view. Leaf positioning accuracy was assessed using individual and moving range control charts. Control limits were recomputed following MLC recalibration (occurred 1–2 times for 4 units). Specification levels of ±0.5, ±1 and ±1.5mm were tested. The mean and range of duration between out-of-control and out-of-specification events were determined. Results: Leaf position varied little over time, as confirmed by very tight individual control limits (mean ±0.19mm, range 0.09–0.44). Mean leaf position error was −0.03mm (range −0.89–0.83). Due to sporadic out-of-control events, the mean in-control duration was 3.3 days (range 1–23). Data stayed within ±1mm specification for 205 days on average (range 3–372) and within ±1.5mm for the entire date range. Measurements stayed within ±0.5mm for 1 day on average (range 0–17); however, our MLC leaves were not calibrated to this level of accuracy. Conclusion: The Elekta Agility MLC model was found to perform with high stability, as evidenced by the tight control limits. The in-specification durations support the current recommendation of monthly MLC QC tests with a ±1mm tolerance. Future work is on-going to determine if Agility performance can be optimized further using high-frequency QC test results to drive recalibration frequency. Factors that can affect leaf positioning accuracy, including beam spot motion, leaf gain calibration, drifting leaves, and image artifacts, are under investigation.

60 APPLIED LIFE SCIENCES↗

Statistical Framework for Planning a Component Shelf Life Program.

This document outlines a statistical framework for establishing a shelf-life program for components whose performance is measured by the value of a continuous variable such as voltage or function time. The approach applies to both single measurement devices and repeated measurement devices, although additional process control charts may be useful in the case of repeated measurements. The approach is to choose a sample size that protects the margin associated with a particular variable over the life of the component. Deviations from expected performance of the measured variable are detected prior to the complete loss of margin. This ensures the reliability of the component over its lifetime.

47 OTHER INSTRUMENTATION↗

Summary of Observations from the 2017 Federal Radiological Monitoring and Assessment Center (FRMAC) Laboratory Analysis Training and Capstone Event

On August 15th thru 17th, 2017 the Federal Radiological Monitoring and Assessment Center (FRMAC) Laboratory Analysis division, the FRMAC Fly Away Laboratory (FAL), the FRMAC Assessment division, and the Mobile Environmental Response Laboratory (MERL) held a training and capstone event for staff from the Environmental Protection Agency (EPA), Remote Sensing Laboratory (RSL), Lawrence Livermore National Laboratory (LLNL), and Sandia National Laboratories (SNL). LAB-100, "Sample Control Training", LAB-200 "QA Specialist Training", and LAB-300 "Laboratory Analysis Manager Training" was given the first two days of the event. The purpose of the training and capstone event was to meet training requirements for billeted FRMAC Lab Analysis staff from RSL, LLNL, and SNL as well as raise awareness of the FRMAC Lab Analysis process with EPA staff as part of a Federal Emergency Management Agency — Nuclear Incident Response Team (FEMA-NIRT) laboratory standardization project. An objective of the standardization project was to help improve the transition of operations from DOE to EPA during a response. To do this effectively, detailed knowledge of the FRMAC Lab Analysis process by the EPA is needed. This training provided a good opportunity for this knowledge transfer. A capstone was held after the two-day training event to allow participants to practice the skills they learned in a realistic scenario. A scenario that was previously developed for a quarterly Consequence Management drill (i.e. Dark Phoenix) was used as the basis for the capstone, with laboratory analysis focused injects used to drive the exercise play. Each position within the FRMAC Lab Analysis Division exercised to specific objectives and helped to uncover gaps in the established processes. The lessons learned during this capstone are broken out in the following categories: Sample Control, In-Situ Gamma Spectroscopy, Analysis Request Forms (ARF), Shipping, QA/QC, Fly Away Laboratory (FAL), and Management.

54 ENVIRONMENTAL SCIENCES↗

A Transformational Natural Gas Fueled Dynamic SOFC for Data Center in-Rack Power (Final Technical Report)

Data centers consume 250TWh or 1% of global electricity use in 2019. This electricity demand is expected to grow exponentially in the future. The current data center power supply relies on electric grids with diesel engines and batteries as backup; the latter is critically important because a sudden loss of power could erase crucial data, causing catastrophic economic loss. However, such a double protection architecture is costly, inefficient and polluting. In search for better in-rack power system, fuel-cell based generators have recently emerged as a promising alternative to diesel engines and batteries because of its potential to be more cost-effective, more efficient and less polluting. Among many types of fuel cells, solid oxide fuel cells stand out to be a front runner because of their ability to directly operate on natural gas that has an existing infrastructure. However, there are several critical challenges facing SOFC generators to meet the rigorous power requirements of data centers: high cost, poor reliability and more importantly, slow response to the datacenters’ dynamic load change. The unexpected overload conditions in data centers can cause fuel starvation; the latter can initiate microcracks in the anode structure, thus jeopardizing the lifetime of the SOFC generator. The current efforts to increase transient power capabilities of traditional SOFCs and therefore protect SOFC stacks from internal damage during transient loading, rely primarily upon mathematical algorithms. One of the challenges to these control methodologies is the physical limitations of the fuel delivery system such as slow response of mass flow controllers to fast power demand.

30 DIRECT ENERGY CONVERSION↗

Genesis Mission-Enabled Secure AI to Fortify Energy Process Safety (Genesis-SAFE)

Argonne National Laboratory is supporting the U.S. Department of Transportation’s (USDOT’s) Bureau of Transportation Statistics (BTS) with collaborative research on development and application of privacy preserving AI frameworks that leverage unmatched AI expertise and secure computing resources made available through the U.S. Genesis Mission1 . This research advances U.S. energy security goals by supporting a safe offshore energy industry with secure, domain-specific AI tools to analyze confidential industry datasets collected by BTS to rapidly improve identification of hazards, precursors, and systemic safety risks in high-risk operational environments. The staged, security-first approach begins with development and testing of Argonne’s Genesis Mission-enabled Secure AI to Fortify Energy Process Safety (Genesis-SAFE) framework within Argonne’s accredited secure computing enclave (ABLE) leveraging Argonne’s AI scientific assistant substrate (AISAC). Methods to build synthetic datasets were developed together with BTS for use in preparing synthetic datasets that can be used to validate data containment, governance, and security controls in the ABLE environment. Future research directions would focus on applying the Genesis-SAFE framework to CIPSEA-protected datasets entirely within ABLE to support confidentiality-preserving analysis of safety risks, trends, and contributing factors.

Kim, Hyekyung [Argonne National Laboratory (ANL), ↗

Oxide Ferromagnetic Semiconductors for Spin-Electronic Transprt

The objective of this research was to investigate the viability of oxide magnetic semiconductors as potential materials for spintronics. We identified some members of the solid solution series of ilmenite (FeTiO3) and hematite (Fe2O3), abbreviated as (IH) for simplicity, for our investigations based on their ferromagnetic and semiconducting properties. With this objective in focus we limited our investigations to the following members of the modified Fe-titanates: IH33 (ilmenitehematite with 33 atomic percent hematite), IH45 (ilmenite-hematite with 45 atomic percent hematite), Mn-substituted ilmenite (Mn-FeTiO3), and Mn-substituted pseudobrookite (Mn- Fe2TiO5). All of them are: 1. wide bandgap semiconductors with band gaps ranging in values between 2.5 to 3.5 eV; 2. n-type semiconductors; 3.they exhibit well defined magnetic hysteresis loops and 4. their magnetic Curie points are greater than 400K. Ceramic, film and single crystal samples were studied and based on their properties we produced varistors (also known as voltage dependent resistors) for microelectronic circuit protection from power surges, three-terminal microelectronic devices capable of generating bipolar currents, and an integrated structured device with controlled magnetic switching of spins. Eleven refereed journal papers, three refereed conference papers and three invention disclosures resulted from our investigations. We also presented invited papers in three international conferences and one national conference. Furthermore two students graduated with Ph.D. degrees, three with M.S. degrees and one with B.S. degree. Also two post-doctoral fellows were actively involved in this research. We established the radiation hardness of our devices in collaboration with a colleague in an HBCU institution, at the Cyclotron Center at Texas A&M University, and at DOE National Labs (Los Alamos and Brookhaven). It is to be appreciated that we met most of our goals and expanded vastly the scope of research by including investigations of Mn-FeTiO3, Mn-Fe2TiO5 and by producing a novel three terminal device capable of generating bipolar currents besides producing radiation resistant varistors and a magnetically switchable device. Furthermore we conclusively established the radiation hardness of the four modified iron titanates we studied. In all our publications, conference and seminar presentations, dissertations and theses sponsorship of DOE has been acknowledged

36 MATERIALS SCIENCE↗

Human reliability-based MC&A models for detecting insider theft.

Material control and accounting (MC&A) safeguards operations that track and account for critical assets at nuclear facilities provide a key protection approach for defeating insider adversaries. These activities, however, have been difficult to characterize in ways that are compatible with the probabilistic path analysis methods that are used to systematically evaluate the effectiveness of a site's physical protection (security) system (PPS). MC&A activities have many similar characteristics to operator procedures performed in a nuclear power plant (NPP) to check for anomalous conditions. This work applies human reliability analysis (HRA) methods and models for human performance of NPP operations to develop detection probabilities for MC&A activities. This has enabled the development of an extended probabilistic path analysis methodology in which MC&A protections can be combined with traditional sensor data in the calculation of PPS effectiveness. The extended path analysis methodology provides an integrated evaluation of a safeguards and security system that addresses its effectiveness for attacks by both outside and inside adversaries.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Signal Processing for Beam Loss Monitor System at Jefferson Lab

Ion Chamber and Photomultiplier Tube (PMT) are both used for beam loss monitor in the Machine Protection System (MPS) at Jefferson Lab. The requirements of signal processing of these detectors are different, so two VME-based signal processing boards, Beam Loss Monitor (BLM) board and Ion-Chamber board, were developed. The BLM board has fast response (< 1us) and 5 decades dynamic range from 10nA to 1 mA, while the Ion-Chamber board has 8 decades dynamic range from 100 pA to 10 mA and slower response. Both of boards provide functions of machine protection and beam diagnostics, and features of fast shutdown (FSD) interface, beam sync interface, built-in-self-test, remotely controlled bias signals, and on-board memory buffer.

Yan, J.↗

Capacity of ETS-10 supported carbon nanosorbent for removal of multicomponent from off-gas stream

Nuclear fission results in fission and activation products, some of which are volatile under the conditions of used nuclear fuel (UNF) reprocessing. Several volatile radionuclides are released into the atmosphere through offgas stream, which includes {sup 3}H, {sup 14}C, {sup 129}I and noble gases, Kr and Xe. {sup 129}I is a highly mobile and volatile contaminant. It has half-life period about 1.57 x 107 years that tends to bioaccumulate, concentrating in the thyroid glands and affecting bio-metabolism in humans. {sup 85}Kr is a chemically inert radioisotope with a half-life of 10.7 years that continuously accumulate in the environment. Control of emissions of these contaminants is necessary to comply with the stringent regulatory limits placed on their releases to protect human health and environment. Removal of these contaminants has been a challenge since the 1950's, and several methods including cryogenic distillation, fluorocarbon absorption, wet scrubbing, and adsorption have been employed. Currently, adsorption on porous solid sorbent shows the most promise results. Up to now, several sorbents such as silver impregnated mordenite, silver ETS-10, chalcogen based aerogels, and metal organic framework, MOFs have been developed for this purpose. Despite these advances, development of economical and highly active sorbents for complete removal and immobilization of volatile radioactive gases remains a key challenge in realizing advanced fuel cycles. Present research work is focused on the determination of the removal capacity of C'at'ETS-10 sorbent for a multicomponent (iodine and krypton) off-gas stream at ambient temperature. Our previously reported work showed that the 10 wt% C'at'ETS-10 sorbent was active for adsorption of krypton as well as iodine at ambient temperature and pressure. Therefore, 10 wt% C'at'ETS-10 sorbent was synthesized by wet-impregnation technique. The performance evaluation of the prepared nanosorbent was examined for the removal of iodine and krypton from the breakthrough curves obtained using bench scale experimental setup. ETS-10 supported carbon nanoparticles, C'at'ETS-10 nanosorbent was successfully synthesized by wet-impregnation technique. The 1/8 inch pelletized sorbent was used to minimize the pressure drop in adsorption column. The capacity of sorbent was found to be 0.143 mg g{sup -1} for krypton and 24.5 mg g{sup -1} for iodine. This experimental results indicates the C'at'ETS-10 is the effect sorbent for removal of multicomponent, krypton as well as iodine from the off-gas stream at ambient temperature. (authors)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

CERTS Microgrid Laboratory Test Bed

The objective of the CERTS Microgrid Test Bed project was to enhance the ease of integrating energy sources into a microgrid. The project accomplished this objective by developing and demonstrating three advanced techniques, collectively referred to as the CERTS Microgrid concept, that significantly reduce the level of custom field engineering needed to operate microgrids consisting of generating sources less than 100kW. The techniques comprising the CERTS Microgrid concept are: 1 a method for effecting automatic and seamless transitions between grid-connected and islanded modes of operation, islanding the microgrid's load from a disturbance, thereby maintaining a higher level of service, without impacting the integrity of the utility's electrical power grid; 2 an approach to electrical protection within a limited source microgrid that does not depend on high fault currents; and 3 a method for microgrid control that achieves voltage and frequency stability under islanded conditions without requiring high-speed communications between sources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

TU-B-304-00: The Aftermath of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

Bifurcations, chaos and adaptive backstepping sliding mode control of a power system with excitation limitation

The bifurcation and Lyapunov exponent for a single-machine-infinite bus system with excitation model are carried out by varying the mechanical power, generator damping factor and the exciter gain, from which periodic motions, chaos and the divergence of system are observed respectively. From given parameters and different initial conditions, the coexisting motions are developed in power system. The dynamic behaviors in power system may switch freely between the coexisting motions, which will bring huge security menace to protection operation. Especially, the angle divergences due to the break of stable chaotic oscillation are found which causes the instability of power system. Finally, a new adaptive backstepping sliding mode controller is designed which aims to eliminate the angle divergences and make the power system run in stable orbits. Numerical simulations are illustrated to verify the effectivity of the proposed method.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-B-304-01: The Aftermath of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

TU-B-304-02: Quantitative FMEA of TG-142

Although published in 2009, the AAPM TG-142 report on accelerator quality assurance still proves a challenge for full clinical implementation. The choice of methodologies to satisfy TG-142 requirements is critical to a successful application. Understanding the philosophy of TG-142 can help in creating an institution-specific QA practice that is both efficient and effective. The concept of maintaining commissioned beam profiles is still found confusing. The physicist must also consider technologies not covered by TG-142 (i.e. arc therapy techniques). On the horizon is TG-198 report on implementing TG-142. Although the community still lacks a final TG-100 report, performing a failure-mode -and-effects analysis and statistical process control analysis to determine the institution-specific clinical impact of each TG-142 test may be useful for identifying trends for pro-active surveillance. Learning Objectives: To better understand the confusing and controversial aspects of TG-142. To understand what is still missing from TG-142 and how to account for these tests in clinical practice To describe which QA tests in TG-142 yield the largest potential clinical result if not discovered.

60 APPLIED LIFE SCIENCES↗

A generic finite state machine framework for the ACNET control system

A significant level of automation and flexibility has been added to the ACNET control system through the development of a Java-based Finite State Machine (FSM) infrastructure. These FSMs are integrated into ACNET and allow users to easily build, test and execute scripts that have full access to ACNET's functionality. In this paper, a description will be given of the FSM design and its ties to the Java-based Data Acquisition Engine (DAE) framework. Each FSM is part of a client-server model with FSM display clients using Remote Method Invocation (RMI) to communicate with DAE servers heavily coupled to ACNET. A web-based monitoring system that allows users to utilize browsers to observe persistent FSMs will also be discussed. Finally, some key implementations such as the crash recovery FSM developed for the Electron Cooling machine protection system will be presented.

99 GENERAL AND MISCELLANEOUS↗