Measuring Loss Tangents of Substrates for Superconducting Qubits with Part-per-Billion Precision

We report precision measurements of dielectric loss tangents in substrates for superconducting qubits using an ultra-high quality factor niobium SRF cavity operating at millikelvin temperatures and low electric fields. Multiple substrate types and surface treatments are compared to assess how processing impacts microwave dissipation. The RF results are correlated with materials analysis, including ToF-SIMS and XPS, to identify dominant loss mechanisms. This combined study links microscopic surface chemistry to macroscopic performance and provides a framework for materials-driven improvements in qubit coherence and device design.

Bafia, Daniel [Fermilab]↗

Measuring Loss Tangents of Substrates for Superconducting Qubits with Part-per-Billion Precision

We report precision measurements of dielectric loss tangents in substrates for superconducting qubits using an ultra-high quality factor niobium SRF cavity operating at millikelvin temperatures and low electric fields. Multiple substrate types and surface treatments are compared to assess how processing impacts microwave dissipation. The RF results are correlated with materials analysis, including ToF-SIMS and XPS, to identify dominant loss mechanisms. This combined study links microscopic surface chemistry to macroscopic performance and provides a framework for materials-driven improvements in qubit coherence and device design.

Bafia, Daniel [Fermilab]↗

Precision spectroscopy of nuclear decays using quantum optomechanical sensors

This project developed and demonstrated a fundamentally new way to detect individual nuclear decays: rather than capturing the energy that decay products deposit in a detector, we measure the tiny mechanical recoil of the entire micron- or nanometer-sized particle in which the decaying nucleus is embedded. Because momentum is conserved, this approach is sensitive even to neutral, weakly interacting particles, including neutrinos, that escape conventional detectors. During the award, the Yale group reported the first-ever mechanical detection of single nuclear decays, a result featured widely in the scientific press, and pushed the sensitivity of smaller levitated nanoparticles into the quantum measurement regime, reaching an impulse resolution within a factor of five of the fundamental Standard Quantum Limit (SQL), good enough in principle to detect the momentum kicked to the particle by a single emitted neutrino. In parallel, the LBNL group developed the theory of quantum-enhanced (sub-SQL) readout tailored to this experiment, showing how squeezed light can push the sensitivity below the SQL. Together these results establish levitated optomechanical sensors as a new tool for precision nuclear decay spectroscopy, with further applications in neutrino physics, quantum metrology, and nuclear forensics and safeguards.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Electroweak Measurements at the LHC and Tevatron

Various electroweak precision measurements are performed at the hadron colliders Tevatron and LHC.The main ones regard the masses of the W boson, top quark and Higgs boson, and sin 2 theta^l_eff.This talk covers the latter and also other measurements carried out using Drell--Yan decays.The results of the sin 2 theta^l_eff measurements have an accuracy of approximately twice that reached at LEP and SLD. The LEP and SLD accuracy is expected to be approached with Run 2 and Run 3 data and surpassed with high-luminosity LHC data.Other measurements reported are the differential distributions and the full set of decay angular coefficient in Drell--Yan events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibrating the DUNE LArTPC detectors for precision physics

The Deep Underground Neutrino Experiment (DUNE) is an international collaboration focused on studying neutrino oscillation over a long baseline (1300 km). DUNE will make use of a near detector and $\mathcal{O}$(GeV) neutrino beam originating at Fermilab in Batavia, IL, and a far detector operating 1.5 km underground at the Sanford Underground Research Facility in Lead, South Dakota. The near and far detectors will use the LArTPC (Liquid Argon Time Projection Chamber) technology to image neutrino interactions. In order to make precise physics measurements at DUNE, such as the amount of CP violation in the neutrino sector, it is essential to be able to accurately reconstruct particle energies and other kinematic quantities; this in turn necessitates an extensive calibration program for DUNE s LArTPC detectors. In this presentation, we describe the requirements for calibrating the DUNE detectors, emphasizing the challenges of massive multi-kiloton LArTPC detectors which are to operate for multiple years deep underground. A preliminary DUNE detector calibration program, including use of both dedicated calibration hardware and cosmogenic/beam-induced calibration sources, is presented. First results on detector calibration at the ProtoDUNE-SP prototype detector located at CERN, and associated impact on calibrations at the DUNE far detector, are also emphasized.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Precision in Selective Assembly

A method is proposed for calculating the limiting deviation and group tolerances when group interchangeability (selective assembly) is used. The example considered is increase in precision of the gap in the joint between a hydraulic cylinder and the piston rod.

42 ENGINEERING↗

Shedding light on the 239Pu fission source term with new high-precision experiments and advanced fission modeling

In the last decade, there has been a renaissance of fission research resulting in new high-precision experiments and advanced fission modeling. For instance, the Chi-Nu and CEA teams supplied, for the first time, the 239 Pu prompt fission neutron spectrum (PFNS) for broad ranges of incident and outgoing neutron energies. The CEA team also measured 239 Pu average prompt neutron multiplicities, ν ̄ p , with lower statistical uncertainties and a technique significantly different than the one used in the past. The NIFFTE collaboration provided 239 Pu( n ,f)/ 235 U( n ,f) cross section shape ratios with uncertainties below 1% utilizing a novel detector type. Advanced fission event generators were developed, among them CGMF, FIFRELIN, FREYA, and GEF, which calculate post-scission fission observables in a correlated manner. These new experimental data and more consistent fission models change the evaluated PFNS, ν ̄ p , and ( n ,f) cross sections, some only modestly, compared to ENDF/B-VIII.0. In turn, the individual new nuclear data distinctly change simulated effective neutron multiplication factors of fast critical assemblies, but their combined impact is small, while affecting the prediction of LLNL pulsed sphere neutron leakage spectra and reaction rates only within experimental uncertainties. Also, the parameters obtained from fitting to ν ̄ p reproduce various post-scission fission observables within the uncertainties of experimental data. This indicates that new differential experiments and consistent fission modeling reduce compensating errors present in ENDF/B-VIII.0.

fission cross section↗

Low-Frequency Mutational Heterogeneity of Invasive Ductal Carcinoma Subtypes: Information to Direct Precision Oncology

Information regarding the role of low-frequency hotspot cancer-driver mutations (CDMs) in breast carcinogenesis and therapeutic response is limited. Using the sensitive and quantitative Allele-specific Competitor Blocker PCR (ACB-PCR) approach, mutant fractions (MFs) of six CDMs (PIK3CA H1047R and E545K, KRAS G12D and G12V, HRAS G12D, and BRAF V600E) were quantified in invasive ductal carcinomas (IDCs; including ~20 samples per subtype). Measurable levels (i.e., ≥ 1 × 10 -5 , the lowest ACB-PCR standard employed) of the PIK3CA H1047R, PIK3CA E545K, KRAS G12D, KRAS G12V, HRAS G12D, and BRAF V600E mutations were observed in 34/81 (42%), 29/81 (36%), 51/81 (63%), 9/81 (11%), 70/81 (86%), and 48/81 (59%) of IDCs, respectively. Correlation analysis using available clinicopathological information revealed that PIK3CA H1047R and BRAF V600E MFs correlate positively with maximum tumor dimension. Analysis of IDC subtypes revealed minor mutant subpopulations of critical genes in the MAP kinase pathway (KRAS, HRAS, and BRAF) were prevalent across IDC subtypes. Few triple-negative breast cancers (TNBCs) had appreciable levels of PIK3CA mutation, suggesting that individuals with TNBC may be less responsive to inhibitors of the PI3K/AKT/mTOR pathway. These results suggest that low-frequency hotspot CDMs contribute significantly to the intertumoral and intratumoral genetic heterogeneity of IDCs, which has the potential to impact precision oncology approaches.

59 BASIC BIOLOGICAL SCIENCES↗

RADiCAL—Precision Timing, Ultracompact, Radiation-Hard Electromagnetic Calorimetry

To address the challenges of providing high-performance calorimetry in future hadron collider experiments under conditions of high luminosity and high radiation (FCC-hh environments), we conducted R&D on advanced calorimetry techniques suitable for such operation, based on scintillation and wavelength-shifting technologies and photosensor (SiPM and SiPM-like) technology. In particular, we focused our attention on ultra-compact radiation-hard EM calorimeters based on modular structures (RADiCAL modules) consisting of alternating layers of the very dense absorber and scintillating plates, read out via radiation hard wavelength shifting (WLS) solid fiber or capillary elements to photosensors positioned either proximately or remotely, depending upon their radiation tolerance. RADiCAL modules provide the capability to measure simultaneously and with high precision the position, energy and timing of EM showers. This paper provides an overview of the instrumentation and photosensor R&D associated with the RADiCAL program.

Anderson, Thomas↗

Ab Initio Calculations of Possible γ-Gauche Effects in the 13C-NMR for Methine and Carbonyl Carbons in Precise Polyethylene Acrylic Acid Copolymers

The impacts of local polymer chain conformations on the methine and carbonyl 13C-NMR chemical shifts for polyethylene acrylic acid p(E-AA) copolymers were predicted using ab initio methods. Using small molecular cluster models, the magnitude and sign of the γ-gauche torsional angle effect, along with the impact of local tetrahedral structure distortions near the carbonyl group, on the 13C-NMR chemical shifts were determined. These 13C-NMR chemical shift variations were compared to the experimental trends observed for precise p(E-AA) copolymers as a function acid group spacing and degree of zinc-neutralization in the corresponding p(E-AA) ionomers. These ab initio calculations address the future ability of 13C-NMR chemical shift variations to provide information about the local chain conformations in p(E-AA) copolymer materials.

13C-NMR↗

Precision Synthesis of Conjugated Polymer Films by Surface-Confined Stepwise Sonogashira Cross-Coupling

Thin films of poly(arylene ethynylene)-conjugated polymers, including low-energy-gap donor–acceptor polymers, can be prepared via stepwise polymerization utilizing surface-confined Sonogashira cross-coupling. This robust and efficient polymerization protocol yields conjugated polymers with a precise molecular structure and with nanometer-level control of the organization and the uniform alignment of the macromolecular chains in the densely packed film. In addition to high stability and predictable and well-defined molecular organization and morphology, the surface-confined conjugated polymer chains experience significant interchain electronic interactions, resulting in dominating intermolecular π-electron delocalization which is primarily responsible for the electronic and spectroscopic properties of polymer films. The fluorescent films demonstrate remarkable performance in chemosensing applications, showing a turn-off fluorescent response on the sub-ppt (part per trillion) level of nitroaromatic explosives in water. This unique sensitivity is likely related to the enhanced exciton mobility in the uniformly aligned and structurally monodisperse polymer films.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast, Nondestructive and Precise Biomass Measurements Are Possible Using Lidar-Based Convex Hull and Voxelization Algorithms

Light detection and ranging (lidar) scanning tools are available that can make rapid digital estimations of biomass. Voxelization and convex hull are two algorithms used to calculate the volume of the scanned plant canopy, which is correlated with biomass, often the primary trait of interest. Voxelization splits the scans into regular-sized cubes, or voxels, whereas the convex hull algorithm creates a polygon mesh around the outermost points of the point cloud and calculates the volume within that mesh. In this study, digital estimates of biomass were correlated against hand-harvested biomass for field-grown corn, broom corn, and energy sorghum. Voxelization (r = 0.92) and convex hull (r = 0.95) both correlated well with plant dry biomass. Lidar data were also collected in a large breeding trial with nearly 900 genotypes of energy sorghum. In contrast to the manual harvest studies, digital biomass estimations correlated poorly with yield collected from a forage harvester for both voxel count (r = 0.32) and convex hull volume (r = 0.39). However, further analysis showed that the coefficient of variation (CV, a measure of variability) for harvester-based estimates of biomass was greater than the CV of the voxel and convex-hull-based biomass estimates, indicating that poor correlation was due to harvester imprecision, not digital estimations. Overall, results indicate that the lidar-based digital biomass estimates presented here are comparable or more precise than current approaches.

Environmental Sciences & Ecology↗

Siberian Snakes, Figure-8 and Spin Transparency Techniques for High Precision Experiments with Polarized Hadron Beams in Colliders

We present a review of the possibilities to conduct experiments of high efficiency in the nuclear and high energy physics with spin-polarized beams in a collider complex, configuration of which includes Siberian snakes or figure-8 collider ring. Special attention is given to the recently elicited advantageous possibility to conduct high precision experiments in a regime of the spin transparency (ST) when the design global spin tune is close to zero. In this regime, the polarization control is realized by use of spin navigators (SN), which are compact special insertions of magnets dedicated to a high flexibility spin manipulation including frequent spin flips.