Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Proteomic Analysis of Saliva in HIV-positive Heroin Addicts Reveals Proteins Correlated with Cognition

The prevalence of HIV-associated neurocognitive disorders (HAND) remains high despite effective antiretroviral therapies. Multiple etiologies have been proposed over the last few years to account for this phenomenon, including the neurotoxic effects of antiretrovirals and co-morbid substance abuse. However, no underlying molecular mechanism has been identified. Emerging evidence in several fields has linked the gut to brain diseases, but the effect of the gut on the brain during HIV infection has not been explored. Saliva is the most accessible gut biofluid, and is therefore of great scientific interest for diagnostic and prognostic purposes. This study presents a longitudinal, liquid chromatography-mass spectrometry-based quantitative proteomics study investigating saliva samples taken from 8 HIV-positive (HIV+) and 11 -negative (HIV-) heroin addicts. In the HIV+ group, 58 proteins were identified that show significant correlations with cognitive scores and that implicate disruption of protein quality control pathways by HIV. Notably, no proteins from the HIV- heroin addict cohort showed significant correlations with cognitive scores. In addition, the majority of correlated proteins have been shown to be associated with exosomes, allowing us to propose that the salivary glands and/or oral epithelium may modulate brain function during HIV infection through the release of discrete packets of proteins in the form of exosomes.

Environmental Molecular Sciences Laboratory↗

Two (or more) for one: Identifying classes of household energy- and water-saving measures to understand the potential for positive spillover

A key component of behavior-based energy conservation programs is the identification of target behaviors. A common approach is to target behaviors with the greatest energy-saving potential. The concept of behavioral spillover introduces further considerations, namely that adoption of one energy-saving behavior may increase (or decrease) the likelihood of other energy-saving behaviors. This research aimed to identify and describe household energy- and water-saving measure classes within which positive spillover is likely to occur (e.g., adoption of energy-efficient appliances may correlate with adoption of water-efficient appliances), and explore demographic and psychographic predictors of each. Nearly 1,000 households in a California city were surveyed and asked to report whether they had adopted 75 different energy- and/or water-saving measures. Principal Component Analysis and Network Analysis based on correlations between adoption of these diverse measures revealed and characterized eight water-energy-saving measure classes: Water Conservation, Energy Conservation, Maintenance and Management, Efficient Appliance, Advanced Efficiency, Efficient Irrigation, Green Gardening, and Green Landscaping. Understanding these measure classes can help guide behavior-based energy program developers in selecting target behaviors and designing interventions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Chemistry data from soils and soil incubation experiments from the whole-soil warming experiment at Blodgett Forest, CA, 2018, from: “Metabolic capabilities mute positive response to direct and indirect impacts of warming throughout the soil profile”

This dataset contains soil chemistry data of soils from the whole-soil warming experiment at Blodgett Forest in June 2018, and from laboratory incubation experiments conducted with a subset of those soils. Soil samples were collected at five different depths down to 80 cm from soil plots continuously heated by 4°C above ambient temperature for 4.5 years, and from the respective unheated control plots. Incubation experiments were conducted for 28 days with soils collected between 10-30 cm (“surface soils”) and 60-80 cm (“subsoils”) from heated and unheated field plots, amended in the laboratory with cellobiose (C, carbon amendment), or cellobiose plus ammonium and phosphate (CNP, combined carbon, nitrogen and phosphorus amendment). The dataset includes separate files for: (i) total carbon and nitrogen concentrations of initial field soils; (ii) carbon dioxide efflux rates at multiple times throughout the incubation experiments, and respective cumulative carbon dioxide efflux rates, as well as inorganic nitrogen concentrations at the beginning and end of the incubations, and net nitrogen mineralization rates and carbon use efficiency calculated at the end of the incubation. Analysis of these data has been published in Dove et al., (2021), “Metabolic capabilities mute positive response to direct and indirect impacts of warming throughout the soil profile. Nat. Commun. 12:2089”, https://doi.org/10.1038/s41467-021-22408-5. This research was performed as part of the TES Belowground Biogeochemistry SFA project at Lawrence Berkeley National Laboratory.

54 ENVIRONMENTAL SCIENCES↗

Performance Test of the Next Generation X-Ray Beam Position Monitor System for The APS Upgrade

The Advanced Photon Source is developing its next major upgrade (APS-U) based on the multi-bend achromat lattice. Improved beam stability is critical for the upgrade and will require keeping short-time beam angle change below 0.25 µrad and long-term angle drift below 0.6 µrad. A reliable white x-ray beam diagnostic system in the front end will be a key part of the planned beam stabilization system. This system includes an x-ray beam position monitor (XBPM) based on x-ray fluorescence (XRF) from two specially designed GlidCop A-15 absorbers, a second XBPM using XRF photons from the Exit Mask, and two white beam intensity monitors using XRF from the photon shutter and Compton-scattered photons from the front end beryllium window or a retractable diamond film in windowless front ends. We present orbit stability data for the first XBPM used in the feedback control during user operations, as well as test data from the second XBPM and the intensity monitors. They demonstrate that the XBPM system meets APS-U beam stability requirements.

Yang, B.↗

Beam Position Monitoring System for Fermilab’s Muon Campus

A Beam Position Monitor (BPM) system has been designed for Fermilab Muon Campus. The BPM system measures Turn-by-Turn orbits as well as Closed Orbits (average of multiple turns). While in the early commissioning phase of this program, preliminary measurements have been made using these BPMs. This paper discusses the design and implementation of these BPMs.

43 PARTICLE ACCELERATORS↗

The study of high-frequency pick-ups for electron beam position measurements in the AWAKE common beamline

The common beamline of the AWAKE experiment at CERN involves the co-propagation of two particle beams: protons with 48 nC bunch charge and 250 ps bunch length, and electrons with up to 600 pC bunch charge and approximately 4 ps bunch length. The existing operational beam position monitors at AWAKE cannot measure the electron bunches whilst the more-intense proton bunches are present, due to their low operating frequency. In order to try to address this challenge, two different types of high-frequency pick-ups were studied, a conical-shaped button pick-up and a Cherenkov diffraction radiation-based pick-up designed to operate at around 30 GHz. Both devices were installed at AWAKE and were connected to two identical read-out systems designed by TRIUMF. This contribution presents and discusses the results obtained from beam-based measurements during the current experimental year.

43 PARTICLE ACCELERATORS↗

Software Architecture for Next Generation Beam Position Monitors at Fermilab

The Fermilab Accelerator Division / Instrumentation Department develops Beam Position Monitor (BPM) systems in-house to support its sprawling accelerator complex. Two new BPM systems have been deployed and another upgraded over the last two years. These systems are based on a combination of VME and Gigabit Ethernet connected hardware and a common Linux-based embedded software platform with modular components. The architecture of this software platform and the considerations for adapting to future machines or upgrade projects will be described.

43 PARTICLE ACCELERATORS↗

Position Paper - Business Breakout

This “Business of File Systems and Archives” position paper will describe several LLNL best practices that help formulate and optimize the cost/benefit analysis all center’s face in their quest to provide an ongoing, exceptional computing environment within a finite budget.

97 MATHEMATICS AND COMPUTING↗

Rechargeable aluminum batteries with conducting polymers as positive electrodes

This report is a summary of research results from an Early Career LDRD project con-ducted from January 2012 to December 2013 at Sandia National Laboratories. Demonstrated here is the use of conducting polymers as active materials in the posi-tive electrodes of rechargeable aluminum-based batteries operating at room tempera-ture. The battery chemistry is based on chloroaluminate ionic liquid electrolytes, which allow reversible stripping and plating of aluminum metal at the negative elec-trode. Characterization of electrochemically synthesized polypyrrole films revealed doping of the polymers with chloroaluminate anions, which is a quasi-reversible reac-tion that facilitates battery cycling. Stable galvanostatic cycling of polypyrrole and polythiophene cells was demonstrated, with capacities at near-theoretical levels (30-100 mAh g -1 ) and coulombic efficiencies approaching 100%. The energy density of a sealed sandwich-type cell with polythiophene at the positive electrode was estimated as 44 Wh kg - 1, which is competitive with state-of-the-art battery chemistries for grid-scale energy storage.

25 ENERGY STORAGE↗

: Small Animal SPECT/CT System Based on Position-Sensitive Semiconductor Detectors

We developed a SPECT/CT system for small-animal imaging utilizing a mechanically cooled, position-sensitive germanium detector for the SPECT camera. The detector offers better energy resolution than any other detector previously used for SPECT and demonstrates dual-isotope imaging capabilities superior to that of current commercial small-animal SPECT systems. We also explored a unique SPECT camera configuration consisting of a silicon detector and germanium detector stacked one behind the other and located behind a multi-pinhole collimator. This scheme is intended for imaging iodine-123 radiotracer distributions, with the ~30 keV x-ray emissions detected in the silicon detector and the 159 keV gamma-ray emissions passing through the silicon and detected in the germanium detector. Image reconstruction methods for combining this multi-energy, multi-magnification data were developed and it was shown that inclusion of the silicon data reduced artifacts in comparison to the germanium data alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of the Reactor Position Independent Monitor (PIM) Diagnostic

In this note I analyze the physics determining the proposed reactor position independent monitor (PIM), which is the ratio ( 240 Pu/ 239 Pu) 1/3 × ( 135 Cs/ 137 Cs) 1/2 . The PIM ratios in any reactor fuel is shown to increase monotonically with the time over which the fuel is irradiated. This is because the Cs ratio determines the neutron flux, while the Pu isotopic ratio is determined by the flux times the irradiation time. If the irradiation time for all fuel rods across the reactor is fixed, the PIM ratio is approximately constant in all rods. However, no information can be extracted from the PIM ratio on Pu isotopics unless both the flux (or Cs ratio) and the irradiation time (from, say, Ru isotopics) are known separately, i.e., the PIM ratio is not a fundamental parameter of any reactor. Thus, unless the PIM ratio has been measured for the specific fuel under interrogation, no information can be deduced from measurements or reactor simulations of PIM ratios in different fuel from the same reactor. However, if a PIM measurement has been in one spent fuel rod from a given reactor, all other rods that are known to have been in the reactor for the same irradiation period can be assumed to have approximately the same PIM ratio.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

University of California, San Diego (UCSD) Sky Imager Cloud Position Study Field Campaign Report

During the University of California, San Diego (UCSD) Sky Imager Cloud Position Study, two University of California, San Diego Sky Imagers (USI) (Figure 1) were deployed the U.S. Department of Energy(DOE)’s Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains SGP) research facility. The UCSD Sky Imagers were placed 1.7 km apart to allow for stereographic determination of the cloud height for clouds over approximately 1.5 km. Images with a 180-degree field of view were captured from both systems during daylight hours every 30 seconds beginning on March 11, 2013 and ending on November 4, 2013. The spatial resolution of the images was 1,748 × 1,748, and the intensity resolution was 16 bits using a high-dynamic-range capture process. The cameras use a fisheye lens, so the images are distorted following an equisolid angle projection.

58 GEOSCIENCES↗

Beam Position Monitor and Energy Analysis at the Fermilab Accelerator Science and Technology Facility

Fermilab Accelerator Science and Technology Facility has produced its first beam with an energy of 20 MeV. This energy is obtained by the acceleration at the Electron Gun and the Capture Cavity 2 (CC2). When fully completed, the accelerator will consist of a photoinjector, one International Liner Collider (ILC)-type cryomodule, multiple accelerator R&D beamlines, and a downstream beamline to inject 300 MeV electrons into the Integrable Optics Test Accelerator (IOTA). We calculated the total energy of the beam and the corresponding energy to the Electron Gun and CC2. Subsequently, a Beam Position Monitors (BPM) error analysis was done, to calculate the device actual resolution.

43 PARTICLE ACCELERATORS↗

High-accuracy local positioning network for the alignment of the Mu2e experiment.

This Diploma thesis describes the establishment of a high-precision local positioning network and accelerator alignment for the Mu2e physics experiment. The process of establishing new network consists of few steps: design of the network, pre-analysis, installation works, measurements of the network and making adjustments. Adjustments were performed using two approaches. First is a geodetic approach of taking into account the Earth’s curvature and the metrological approach of a pure 3D Cartesian system on the other side. The comparison of those two approaches is performed and evaluated in the results and compared with expected differences. The effect of the Earth’s curvature was found to be significant for this kind of network and should not be neglected. The measurements were obtained with Absolute Tracker AT401, leveling instrument Leica DNA03 and gyrotheodolite DMT Gyromat 2000. The coordinates of the points of the reference network were determined by the Least Square Meth od and the overall view is attached as Annexes.

43 PARTICLE ACCELERATORS↗

An Angular Method with Position Control for Block Mesh Squareness Improvement

We optimize a target function de ned by angular properties with a position control term for a basic stencil with a block-structured mesh, to improve element squareness in 2D and 3D. Comparison with the condition number method shows that besides a similar mesh quality regarding orthogonality can be achieved as the former does, the new method converges faster and provides a more uniform global mesh spacing in our numerical tests.

97 MATHEMATICS AND COMPUTING↗

High Efficiency, Low EMI and Positioning Tolerant Wireless Charging of EVs

The objective of this project is to develop, implement, and demonstrate a wireless power transfer (WPT) system that is capable of the following metrics: Total system efficiencies of more than 85 percent with minimum 20 cm coil-to-coil gap; System output power at least 6.6 kW; but design system up to 19.2 kW for future higher power study; Maximum lateral positioning tolerance achievable while meeting regulatory emission guidelines.

25 ENERGY STORAGE↗