Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase separation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

The Rb-Sr age of a crystalline rock from Apollo 16.

Sample 68415 is one of the few large crystalline rocks returned from Apollo 16. A meaningful age may be obtained if the sample studied represents silicate material which was isotopically homogenized at the last time it was melted. It is also assumed that the constituent phases of the sample have remained closed systems subsequent to that time. The material was crushed and separated into different fractions with the aid of heavy liquids. It was found that the mineral separates are mixtures of at least three distinct phases with intrinsically different Rb/Sr ratios. An age of 3.84 aeon was determined.

Papanastassiou, D. A.↗

Permeation Properties of Disordered Metal-Organic Framework Membranes Made by Vapor Phase Ligand Treatment

Zeolitic imidazolate frameworks (ZIFs) are nanoporous molecular sieves offering exciting opportunities for membrane- and adsorption-based gas separations. The Tsapatsis group developed an all-vapor-phase ligand induced permselectivation (LIPS) method for the fabrication of ZIF nanocomposite membranes. The LIPS method consists of a combination of atomic layer deposition of a dense oxide inside the mesopores of a porous support followed by transformation of the dense oxide deposit to nanoporous ZIF by exposure to sublimated vapors of an imidazolate ligand. It enables the formation of thin nanocomposite films consisting of ZIF deposited inside pores with diameters smaller than 10 nm. Vapor-phase conversion of the impermeable ZnO to ZIF increases flux of certain gases more than others. Vapor phase linker/ligand treatment (VPLT) can further modify the properties of LIPS and other membranes. The combination of LIPS with VPLT provides an all-vapor methodology for making and modifying ZIF membranes with the ability to control the ZIF deposit composition and the level of confinement in a variety of mesoporous supports. The propylene/propane separation performance of LIPS/VPLT ZIF membranes confined (entirely or partially) inside mesopores is remarkably superior to that of most conventional ZIF membranes consisting of unconfined (deposited on the external surface of porous supports) polycrystalline films. The accomplishments of this award are: (i) understanding of the LIPS process using mathematical models of atomic layer deposition (ALD), (ii) development of surface modification methods (vapor, e-beam, plasma, and X-ray treatments) to tune permeation properties, (iii) microstructural control of ZIF-8 films using ALD (support modification, direct ALD, and by use of in situ permeability monitoring), (iv) molecular simulations, and (v) thin film characterization and adsorption measurements using spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Modified LC/MS/MS Method with Enhanced Sensitivity for the Determination of Scopolamine in Human Plasma

Intranasal scopolamine is a choice drug for the treatment of motion sickness during space flight because of its quick onset of action, short half-life and favorable sideeffects profile. The dose administered usually ranges between 0.1 and 0.4 mg. Such small doses make it difficult to detect concentrations of scopolamine in biological fluids using existing sensitive LC/MS/MS method, especially when the biological sample volumes are limited. To measure scopolamine in human plasma to facilitate pharmacokinetic evaluation of the drug, we developed a sensitive LC/MS/MS method using 96 well micro elution plates for solid phase extraction (SPE) of scopolamine in human plasma. Human plasma (100-250 micro L) were loaded onto Waters Oasis HLB 96 well micro elution plate and eluted with 50 L of organic solvent without evaporation and reconstitution. HPLC separation of the eluted sample was performed using an Agilent Zorbax SB-CN column (50 x 2.1 mm) at a flow rate of 0.2 mL/min for 3 minutes. The mobile phase for separation was 80:20 (v/v) methanol: ammonium acetate (30 mM) in water. Concentrations of scopolamine were determined using a Micromass Quattro Micro(TM) mass spectrometer with electrospray ionization (ESI). ESI mass spectra were acquired in positive ion mode with multiple reaction monitoring for the determination of scopolamine m/z = 304.2 right arrow 138.1 and internal standard hyoscyamine m/z = 290.2 right arrow 124.1. The method is rapid, reproducible, specific and has the following parameters: scopolamine and the IS are eluted at about 1.1 and 1.7 min respectively. The linear range is 25-10000 pg/mL for scopolamine in human plasma with correlation coefficients greater than 0.99 and CV less than 0.5%. The intra-day and inter-day CVs are less than 15% for quality control samples with concentrations of 75,300, and 750 pg/mL of scopolamine in human plasma. SPE using 96 well micro elution plates allows rapid sample preparation and enhanced sensitivity for the LC/MS/MS determination of scopolamine in a small volume of biological samples. The new method is also cost effective since it uses a small volume of organic solvents compared to the methods using SPE cartridges or regular 96 well SPE plates. This method can be successfully used for bioavailability and pharmacokinetic evaluations of scopolamine, especially when volumes of biological samples are limited. Further investigation to use automated SPE system with 96 well micro elution plates is planned.

Wang, Zuwei↗

Lithium isotopic analysis in depleted lithium salts

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. Here, in this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts across both depleted and natural isotopic abundances. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for online process monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

Relaxing USOS Solar Array Constraints for Russian Vehicle Undocking

With the retirement of Space Shuttle cargo delivery capability and the ten year life extension of the International Space Station (ISS) more emphasis is being put on preservation of the service life of ISS critical components. Current restrictions on the United States Orbital Segment (USOS) Solar Array (SA) positioning during Russian Vehicle (RV) departure from ISS nadir and zenith ports cause SA to be positioned in the plume field of Service Module thrusters and lead to degradation of SAs as well as potential damage to Sun tracking Beta Gimbal Assemblies (BGA). These restrictions are imposed because of the single fault tolerant RV Motion Control System (MCS), which does not meet ISS Safety requirements for catastrophic hazards and dictates 16 degree Solar Array Rotary Joint position, which ensures that ISS and RV relative motion post separation, does lead to collision. The purpose of this paper is to describe a methodology and the analysis that was performed to determine relative motion trajectories of the ISS and separating RV for nominal and contingency cases. Analysis was performed in three phases that included ISS free drift prior to Visiting Vehicle separation, ISS and Visiting Vehicle relative motion analysis and clearance analysis. First, the ISS free drift analysis determined the worst case attitude and attitude rate excursions prior to RV separation based on a series of different configurations and mass properties. Next, the relative motion analysis calculated the separation trajectories while varying the initial conditions, such as docking mechanism performance, Visiting Vehicle MCS failure, departure port location, ISS attitude and attitude rates at the time of separation, etc. The analysis employed both orbital mechanics and rigid body rotation calculations while accounting for various atmospheric conditions and gravity gradient effects. The resulting relative motion trajectories were then used to determine the worst case separation envelopes during the clearance analysis. Analytical models were developed individually for each stage and the results were used to build initial conditions for the following stages. In addition to the analysis approach, this paper also discusses the analysis results, showing worst case relative motion envelopes, the recommendations for ISS appendage positioning and the suggested approach for future analyses.

Menkin, Evgeny↗

The structure of radio sources 3C 273B and 3C 84 deduced from the 'closure' phases and visibility amplitudes observed with three-element interferometers

The derived 'closure' phase relation for a three-element interferometer is used in a presented analysis of data obtained from observations at 7.8 GHz of the radio sources 3C 273B and 3C 84 by antennas in Massachusetts, California, Alaska, and Sweden (the first two antennas were used in combination with each of the last two separately to form two three-element interferometers). The brightness distribution is found for each source by expansion of both the fringe amplitude and the fringe phase in separate Fourier series.

Rogers, A. E. E.↗

Comparison of the MODIS Multilayer Cloud Detection and Thermodynamic Phase Products with CALIPSO and CloudSat

CALIPSO and CloudSat, launched in June 2006, provide global active remote sensing measurements of clouds and aerosols that can be used for validation of a variety of passive imager retrievals derived from instruments flying on the Aqua spacecraft and other A-Train platforms. The most recent processing effort for the MODIS Atmosphere Team, referred to as the "Collection 5" stream, includes a research-level multilayer cloud detection algorithm that uses both thermodynamic phase information derived from a combination of solar and thermal emission bands to discriminate layers of different phases, as well as true layer separation discrimination using a moderately absorbing water vapor band. The multilayer detection algorithm is designed to provide a means of assessing the applicability of 1D cloud models used in the MODIS cloud optical and microphysical product retrieval, which are generated at a 1 h resolution. Using pixel-level collocations of MODIS Aqua, CALIOP, and CloudSat radar measurements, we investigate the global performance of the thermodynamic phase and multilayer cloud detection algorithms.

Platnick, Steven↗

Comparison of the MODIS Collection 5 Multilayer Cloud Detection Product with CALIPSO

CALIPSO, launched in June 2006, provides global active remote sensing measurements of clouds and aerosols that can be used for validation of a variety of passive imager retrievals derived from instruments flying on the Aqua spacecraft and other A-Train platforms. The most recent processing effort for the MODIS Atmosphere Team, referred to as the Collection 5 scream, includes a research-level multilayer cloud detection algorithm that uses both thermodynamic phase information derived from a combination of solar and thermal emission bands to discriminate layers of different phases, as well as true layer separation discrimination using a moderately absorbing water vapor band. The multilayer detection algorithm is designed to provide a means of assessing the applicability of 1D cloud models used in the MODIS cloud optical and microphysical product retrieval, which are generated at a 1 km resolution. Using pixel-level collocations of MODIS Aqua, CALIOP, we investigate the global performance of multilayer cloud detection algorithms (and thermodynamic phase).

Platnick, Steven↗

Organics in water contamination analyzer, phase 1

The requirements which would result in identifying the components of an automatic analytical system for the analysis of specific organic compounds in the space station potable water supply are defined. The gas chromatographic system for such an analysis is limited to commercially available off-the-shelf hardware and includes the sample inlet, an ionization detector, capillary columns as well as computerized compound identification. The sampling system will be a special variation of the purge and trap Tenax mode using six-port valves and a 500 microliter water sample. Capillary columns used for the separating of contaminants will be bonded phase fused silica with a silicone stationary phase. Two detectors can be used: photoionization and far ultraviolet, since they are sensitive and compatible with capillary columns. A computer system evaluation and program with the principle of compound identification based on the retention index is presented.

Source record↗

The structure of particle-laden jets and nonevaporating sprays

Mean and fluctuating gas velocities, liquid mass fluxes and drop sizes were in nonevaporating sprays. These results, as well as existing measurements in solid particle-laden jets, were used to evaluate models of these processes. The following models were considered: (1) a locally homogeneous flow (LHF) model, where slip between the phases was neglected; (2) a deterministic separated flow (DSF) model, where slip was considered but effects of particle dispersion by turbulence were ignored; and (3) a stochastic separated flow (SSF) model, where effects of interphase slip and turbulent dispersion were considered using random-walk computations for particle motion. The LHF and DSF models did not provide very satisfactory predictions over the present data base. In contrast, the SSF model performed reasonably well - including conditions in nonevaporating sprays where enhanced dispersion of particles by turbulence caused the spray to spread more rapidly than single-phase jets for comparable conditions. While these results are encouraging, uncertainties in initial conditions limit the reliability of the evaluation. Current work is seeking to eliminate this deficiency.

Shuen, J. S.↗

A -type antiferromagnetic order in the Zintl-phase insulator EuZn 2 P 2

Zintl phases, containing strongly covalently bonded frameworks with separate ionically bonded ions, have emerged as a critical materials family in which to couple magnetism and strong spin-orbit coupling to drive diverse topological phases of matter. Here we report the single-crystal synthesis, magnetic, thermodynamic, transport, and theoretical properties of the Zintl compound EuZn 2 P 2 that crystallizes in the anti-La 2 O 3 (CaAl 2 Si 2 ) P-3m1 structure, containing triangular layers of Eu 2+ ions. In-plane resistivity measurements reveal insulating behavior with an estimated activation energy of E g = 0.11eV. Specific heat and magnetization measurements indicate antiferromagnetic ordering at T N = 23K. Curie-Weiss analysis of in-plane and out of plane magnetic susceptibility from T = 150 to 300 K yields p eff = 8.61 for μ 0 H⊥c and p eff = 7.74 for μ 0 H//c, close to the expected values for the 4f 7 J = S = 7/2 Eu 2+ ion and indicative of weak anisotropy. Below T N , a significant anisotropy of χ ⊥ /χ // ≈ 2.3 develops, consistent with A-type magnetic order as observed in isostructural analogs and as predicted by the density functional theory calculations reported herein. The positive Weiss temperatures of θ W =19.2K for μ 0 H⊥c and θ W =41.9K for μ 0 H//c show a similar anisotropy and suggest competing ferromagnetic and antiferromagnetic interactions. Comparing Eu magnetic ordering temperatures across trigonal EuM 2 X 2 (M= divalent metal, X= pnictide) shows that EuZn 2 P 2 exhibits the highest ordering temperature, with variations in T N correlating with changes in expected dipolar interaction strengths within and between layers and independent of the magnitude of electrical conductivity. These results provide experimental validation of the crystochemical intuition that the cation Eu 2+ layers and the anionic (M 2 X 2 ) 2– framework can be treated as electronically distinct subunits, enabling further predictive materials design.

36 MATERIALS SCIENCE↗

Characterizing Porous and Nonporous Phenolic Resins from Molecular Dynamics Simulations

Phenolic resins are an important component of many ablative heat shield materials, which protect spacecrafts from the extreme temperatures reached during atmospheric entry. Examples include the high-density Heritage Carbon Phenolic (HCP) used in the Pioneer-Venus and Galileo missions, as well as the low-density Phenolic Impregnated Carbon Ablator (PICA) used in the Mars Science Laboratory and Mars 2020 missions. Additionally, recent developments within NASA have produced the mid-density Heatshield for Extreme Entry Environment Technology (HEEET) and its derivative 3D Woven Mid-Density Carbon Phenolic (3MDCP). Unlike the nonporous phenolic in HCP, PICA and HEEET/3MDCP are fabricated by infusing preforms with diluted phenolic formulations to obtain a lower density porous matrix. Despite the importance of the phenolic phase to the material response during entry, the variation in properties of porous and nonporous phenolic is not well understood. Here, we present an investigation of porous and nonporous phenolic resins using molecular dynamics (MD) simulations. Resin cure is mimicked in the simulations through the inclusion of representative reaction templates to generate accurate models of the complex crosslinked structures. To create porous models, explicit solvent molecules are included during the cure simulations. We observe nanoscale separation of the phenolic and solvent phases, which results in significant differences in the final structures of porous and nonporous models. In addition to a quantitative assessment of the network structure and porosity, we elucidate the effects of the phenolic formulation on the final material properties. These results are compared with experimental data as appropriate.

phenolic↗

Comparison of automated pre-column and post-column analysis of amino acid oligomers

It has been shown that various amino acids will polymerize under plausible prebiotic conditions on mineral surfaces, such as clays and soluble salts, to form varying amounts of oligomers (n = 2-6). The investigations of these surface reactions required a quantitative method for the separation and detection of these amino acid oligomers at the picomole level in the presence of nanomole levels of the parent amino acid. In initial high-performance liquid chromatography (HPLC) studies using a classical postcolumn o-phthalaldehyde (OPA) derivatization ion-exchange HPLC procedure with fluorescence detection, problems encountered included lengthy analysis time, inadequate separation and large relative differences in sensitivity for the separated species, expressed as a variable fluorescent yield, which contributed to poor quantitation. We have compared a simple, automated, pre-column OPA derivatization and reversed-phase HPLC method with the classical post-column OPA derivatization and ion-exchange HPLC procedure. A comparison of UV and fluorescent detection of the amino acid oligomers is also presented. The conclusion reached is that the pre-column OPA derivatization, reversed-phase HPLC and UV detection produces enhanced separation, improved sensitivity and faster analysis than post-column OPA derivatization, ion-exchange HPLC and fluorescence detection.

NASA Discipline Exobiology↗

Implementation and evaluation of multi-dual mode counter-current chromatography in the CUP Modeler software

Counter-current chromatography (CCC) is a separation technique that utilizes immiscible solvent pairs as stationary and mobile phases, which imparts numerous benefits compared to solid-liquid chromatography including the ability to treat either the more-dense or less-dense solvent layer as the mobile phase. Multi-dual mode (MDM) is a CCC elution mode capable of improving the separation of closely eluting compounds by alternating upper- and lower-layer solvent flows in opposing directions within the same separation. While some effort has been made to model MDM, implementation of these models in experimental design has yet to be widely adopted. Accordingly, we further developed our previously published cell utilized partitioning (CUP) model to include MDM predictions with CCC and packaged the full suite of CUP modeling capabilities into a user-friendly, open-source tool called the CUP Modeler. The mathematical model for MDM CCC was derived and validated with experimental separation of ethyl guaiacol (EG) and ethyl phenol (EP), two compounds that co-elute in our previously demonstrated reductive catalytic fractionation (RCF) lignin monomer isolation method. The developed MDM model provided insights into the effect of multiple operating parameters - including stationary phase retention, flow rate, column efficiency, feed concentration ratio, selectivity factor, and solute distribution ratios - on the separation yields, productivity, and purities. Our model agreed with prevailing understanding of MDM but also revealed new insights including that the ideal distribution ratios for co-eluting solutes to be separated by MDM is between 1.1 and 1.5, with the lower value ideally close to 1.25. Overall, this work provides fundamental insights for MDM process design and enables broader adoption of general liquid-liquid chromatography with a new, open-source user-friendly interface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reactive Extrusion of Waste Plastics with Compatibilizer and Lightly Pyrolyzed Crumb Rubber for Asphalt Modification

Modifying asphalt is a potentially high-value application for reusing waste plastics because of the high-volume usage of asphalt in highway construction. However, simply blending hot plastics and asphalt encounters difficulties related to the poor solubility of polymers, which limits the formation of a swollen network with asphalt molecules. The polymer phases also tend to coalesce and separate from asphalt during high-temperature storage in static conditions. The present study developed an innovative process to stabilize waste plastics in asphalt and improve binder storage stability by using lightly pyrolyzed crumb rubber together with a chemical compatibilizer. Both polymers were extruded to produce a thermoplastic elastomer (TPE) for asphalt modification. The mechanical performance and chemical reactions of TPEs were characterized via tension test and Fourier transform infrared spectroscopy. The storage stability and rheological properties of modified binder blends were evaluated through laboratory asphalt stability test and dynamic shear rheometer test. Polymer phases and network structures were characterized through optical microscopy. It was found that the pyrolyzed and reactive extrusion process improved the rubber solubility and polymer interaction, and therefore the storage stability of modified binder blends. The co-existence of rigid plastic and soft rubbery regimes in an entangled network provided a promising pathway to improve the mechanical performance of asphalt binders in both high- and low-temperature domains.

Ma, Yuetan↗

At-source Recovery of Rare Earth Elements from Coal Mine Drainage

Conventional acid mine drainage (AMD) treatment consists of pH adjustment, oxidation, and separation of solid precipitates from discharge quality water. Alkaline addition increases the pH to the range 7 to 9 to precipitate the regulated metals Al and Mn ions as hydroxides. Mechanical or chemical oxidation then converts the reduced iron species Fe 2+ to Fe 3+ which precipitates at a low pH value as ferric hydroxide (Fe(OH) 3 ). Co-precipitation of Rare Earth Elements (REEs) with hydroxides creates a gangue-rich matrix from which REEs must be separated. Fe(OH)3 is generally the most abundant gangue-forming metal. Current research by the project team has shown raw, untreated AMD has an average total rare earth element content (TREE) of about 287 μg/L (0.287 ppm). Operators of AMD-producing facilities are obliged to treat it to neutralize acidity and remove regulated metals (e.g., iron (Fe), aluminum (Al), and manganese (Mn)) prior to discharge. Ongoing research indicates conventional AMD treatment concentrates TREE in resulting precipitates (AMD sludge) by an average factor of 2,635x to an average dry weight, elemental concentration of 708 g/t (ppm). While the economics of recovering REEs from AMD sludge are appealing, much of the cost of REE recovery would be incurred during separation of REEs from the gangue metals: Fe, Al, and Mn. Significant gains can be made by precipitating REEs when most of these gangue metals are still in solution. Significant improvements in REE extraction efficiency can be obtained through separation of REEs from the aqueous phase AMD, upstream of conventional AMD treatment by: 1) creating an enriched REE feedstock, 2) producing a more consistent feedstock, 3) reducing transportation costs to an REE refinery, 4) reducing acid consumption in the acid leaching step, and 5) reducing the volume of waste produced at the ALSX plant. This project is exploring two novel approaches for extracting REEs upstream of the conventional AMD treatment plants to create a purified REE feedstock while leaving the bulk of the Fe, Al, and Mn in solution for subsequent treatment. While the average TREE concentration of raw AMD is low and individual sites range between 10 and 2,200 μg/L, successful at-source REE separation will generate a superior feedstock to a conventional ALSX process and significantly improve the economics and environmental performance of REE extraction from AMD. AMD can be classified into two types: type A is net acid and iron is partly oxidized while type B is net alkaline, and iron occurs in the reduced, ferrous state. In Case A, the pH is raised slightly, which will precipitate Fe 3+ and Al 3+ but not REEs. The other important type of AMD is net alkaline water found in flooded, anoxic deep mines. These generally have a pH > 6.0 and are net alkaline. REE concentrations are also much lower than those found in acidic AMD while the volumes and flux are much higher. Most of these are pumped discharges with almost no Al. Case B AMD is strongly reduced and, like Case A water, Fe and Mn ions are similarly reduced and therefore soluble at pH <9.0. REEs and an array of transition ions will be the only trivalent cations in this type of AMD. In Case B, both upward pH adjustment under reducing conditions and application of an electrochemically stimulated supported liquid membrane strategy to separate REEs from ferrous ion will be explored.

01 COAL, LIGNITE, AND PEAT↗

Phase partitioning in space and on earth

The influence of gravity on the efficiency and quality of the impressive separations achievable by bioparticle partitioning is investigated by demixing polymer phase systems in microgravity. The study involves the neutral polymers dextran and polyethylene glycol, which form a two-phase system in aqueous solution at low concentrations. It is found that demixing in low-gravity occurs primarily by coalescence, whereas on earth the demixing occurs because of density differences between the phases.

Van Alstine, James M.↗