Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Rating Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Fluid-Dynamic Mechanisms Underlying Wind Turbine Wake Control with Strouhal-Timed Actuation

A reduction in wake effects in large wind farms through wake-aware control has considerable potential to improve farm efficiency. This work examines the success of several emerging, empirically derived control methods that modify wind turbine wakes (i.e., the pulse method, helix method, and related methods) based on Strouhal numbers on the O(0.3). Drawing on previous work in the literature for jet and bluff-body flows, the analyses leverage the normal-mode representation of wake instabilities to characterize the large-scale wake meandering observed in actuated wakes. Idealized large-eddy simulations (LES) using an actuator-line representation of the turbine blades indicate that the n=0 and ±1 modes, which correspond to the pulse and helix forcing strategies, respectively, have faster initial growth rates than higher-order modes, suggesting these lower-order modes are more appropriate for wake control. Exciting these lower-order modes with periodic pitching of the blades produces increased modal growth, higher entrainment into the wake, and faster wake recovery. Modal energy gain and the entrainment rate both increase with streamwise distance from the rotor until the intermediate wake. This suggests that the wake meandering dynamics, which share close ties with the relatively well-characterized meandering dynamics in jet and bluff-body flows, are an essential component of the success of wind turbine wake control methods. A spatial linear stability analysis is also performed on the wake flows and yields insights on the modal evolution. In the context of the normal-mode representation of wake instabilities, these findings represent the first literature examining the characteristics of the wake meandering stemming from intentional Strouhal-timed wake actuation, and they help guide the ongoing work to understand the fluid-dynamic origins of the success of the pulse, helix, and related methods.

17 WIND ENERGY↗

End-User Perspectives on Using Quantitative Real-Time PCR and Genomic Sequencing in the Field

Quantitative real-time PCR and genomic sequencing have become mainstays for performing molecular detection of biological threat agents in the field. There are notional assessments of the benefits, disadvantages, and challenges that each of these technologies offers according to findings in the literature. However, direct comparison between these two technologies in the context of field-forward operations is lacking. Most market surveys, whether published in print form or provided online, are directed to product manufacturers who can address their respective specifications and operations. One method for comparing these technologies is surveying end-users who are best suited for discussing operational capabilities, as they have hands-on experience with state-of-the-art molecular detection platforms and protocols. These end-users include operators in military defense and first response, as well as various research scientists in the public sector such as government and service laboratories, private sector, and civil society such as academia and nonprofit organizations performing method development and executing these protocols in the field. Our objective was to initiate a survey specific to end-users and their feedback. We developed a questionnaire that asked respondents to (1) determine what technologies they currently use, (2) identify the settings where the technologies are used, whether lab-based or field-forward, and (3) rate the technologies according to a set list of criteria. Of particular interest are assessments of sensitivity, specificity, reproducibility, scalability, portability, and discovery power. This article summarizes the findings from the end-user perspective, highlighting technical and operational challenges.

59 BASIC BIOLOGICAL SCIENCES↗

An Approach to Dependence Assessment in Human Reliability Analysis: Application of Lag and Linger Effects

Dependence assessment refers to an approach used in human reliability analysis (HRA) to adjust a human error probability (HEP) for the following action by considering the impact of the preceding action. It has been known to significantly affect the overall results of probabilistic safety assessment (PSA). If the dependence assessment is not adequate, the result could be unconvincing for explaining the operator failures in the context of PSA. To date, several methods and some recent research have identified suggestions for treating dependence issues in HRA; however, these are still exclusively based on the intrinsic approach of the Technique for Human Error Rate Prediction (THERP), an HRA method. THERP inevitably has a challenge with the subjectivity of expert evaluation as well as the requirement for PSA and HRA expertise with resource-intensive and time-consuming processes. This paper suggests an approach to dependence assessment that could not only minimize the influence of expert judgment, but also saves time to perform the analysis with reasonable manpower. It modifies existing HRA methods with considering lag and linger effects to apply dependence effects for them. Based on a representative HRA method, i.e., Standardized Plant Analysis Risk - HRA (SPAR-H), guidance for how to apply lag and linger effects for the HRA method is suggested. Then, an investigation is carried out to compare quantification results of the revised HRA method with that of the original approach based on experimental data.

99 GENERAL AND MISCELLANEOUS↗

Characterization of spent filters from the water polishing system of IEA-R1 Reactor - 15451

The aim of this paper is to report studies performed to determine the activity of gamma emitters present in polypropylene cartridge filters from the polishing system of the IEA-R1 Reactor cooling-water primary circuit. The activities were calculated using the dose rates measured with hand-held detectors, after the ratios of the emission rates of photons were evaluated by gamma spectrometry, and the Point Kernel method, which correlates the activity of a source with the dose rates at various distances. The method described can be used to determine routinely the radioactive inventory of these filters, avoiding the necessity of destructive radiochemical analysis, or the necessity of calibrating the geometry of measurement. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Vertical Axis Wind Turbine (VAWT) with Thermoplastic Composite Blades

Rising concerns about global climate change, planet pollution and increasing use of energy have accelerated wider utilization of renewable energy sources. A recent trend in energy system development is decentralization of power generation systems. The opportunity for individuals or organizations to generate electricity locally decreases losses and part of the electricity price caused by the long-distance power transmission. Vertical axis wind turbines (VAWTs) cannot compete with traditional horizontal axis wind turbines (HAWTs) on the basis of aerodynamic performance or maximum power output generated for a given footprint. However, their ability to perform at a wide range of wind speeds, indifference to wind direction, simplicity of fabrication, transportability and maintainability make them ideal candidates for decentralized installations in urban and residential areas. The project team including Steelhead Composites (SHC), Colorado State University (CSU), National Renewable Energy Laboratory (NREL) and Arkema Inc. designed and fabricated a VAWT rotor assembly with thermoplastic composite blades using novel infusion and fabrication techniques. This full-scale VAWT rotor assembly was designed for a rated power output of 0.5-1 kW, as estimated through analytical computational fluid dynamics (CFD) methods. Those CFD simulations were combined with structural finite element analysis (FEA) to optimize the shape and composite layup of the wind blades. Much of the emphasis of this program was to characterize the recyclable thermoplastic material and composite structural design, in order to take full advantage of the material properties of such composites. Additionally, this project examined the potential of thermoplastic resin systems to transform the way VAWT rotor assemblies are joined both in the factory in in the field, by utilizing thermally welded joints to minimize field failure. The infused composite blades manufactured during this program are an excellent example of these benefits made possible by the Arkema thermoplastic resin system. This prototype blade manufacturing also provided the groundwork to inform decisions for larger scale manufacturing techniques applicable to a commercialization strategy. There is specific commercial interest for small scale VAWT’s that are competitively priced, perform to expectations, and have environmentally conscious end-of-life characteristics. Economic analysis was also conducted to compare designs and material usage, providing an estimated levelized cost of energy (LCOE) for the VAWT. The next steps for commercialization would include testing of the rotor assembly to verify predicted performance, specification of the balance of plant components (generator, inverter, etc.), and identification of a manufacturing partner with capability to scale-up production. This program has showed the potential for a commercially viable product through detailed analysis, material characterization and prototype fabrication.

17 WIND ENERGY↗

High-Dose-Rate Brachytherapy Boost Effect on Local Tumor Control in Young Women With Breast Cancer

Purpose: To evaluate the local control rate and complications of a single fraction of high-dose-rate brachytherapy (HDR BT) boost in women aged 45 yeas and younger after breast-conserving therapy. Methods and Materials: Between 1999 and 2007, 167 patients between the ages of 26 and 45 years old (72 were 40 years old or younger), with stages T1 to T2 invasive breast cancer with disease-free margin status of at least 5 mm after breast-conserving surgery received 46 to 50 Gy whole-breast irradiation plus a 7-Gy HDR-BT boost (“fast boost”). An axillary dissection was performed in 72.5% of the patients and sentinel lymph node biopsy in 27.5%. A supraclavicular area was irradiated in 19% of the patients. Chemotherapy was used in 86% of the patients and hormone treatment in 77%. Clinical nodes were present in 18% and pathological nodes in 29%. The pathological stage was pT0: 5%, pTis: 3%, pT1: 69% and pT2: 23%. Intraductal component was present in 40% and 28% were G3. Results: At a median follow-up of 92 months, 9 patients relapsed on the margin of the implant, and 1 patient in another quadrant, resulting in a 10-year local relapse rate of 4.3% and a breast relapse rate of 4.9%, with breast preservation in 93.4%; no case of mastectomy due to poor cosmesis arose. Actuarial 5- and 10-year disease-free, cause-specific, and overall survival rates were 87.9% and 85.8%, and 92.1% and 88.4%, and 92.1% and 87.3%, respectively. In a univariate analysis, triple-negative cases and negative hormone receptors did worse, but in a multivariate analysis, only the last factor was significant for local and breast control. Asymptomatic fibrosis G2 was recorded in 3 cases, and there were no other late complications. Cosmetic results were good to excellent in 97% of cases. Conclusions: A single dose of 7 Gy using the fast-boost technique is well tolerated, with a low rate of late complications and improved local tumor control in women aged 45 and younger, compared to published data. This approach is recommended in breast-preserving treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Salvage Treatment With Hypofractionated Radiotherapy in Patients With Recurrent Small Hepatocellular Carcinoma

Purpose: To investigate the rates of tumor response and local control in patients with recurrent small hepatocellular carcinoma (HCC) treated with hypofractionated radiotherapy (RT) as a salvage treatment and to evaluate treatment-related toxicities. Methods and Materials: Between 2006 and 2009, a total of 20 patients with recurrent small HCC were treated with hypofractionated RT after the failure of previous treatment. The eligibility criteria for hypofractionated RT were as follows: 1) HCC less than 5 cm, 2) HCC not adjacent to critical organs, 3) HCC without portal vein tumor thrombosis, and 4) less than 15% of normal liver volume that would be irradiated with 50% of prescribed dose. The RT dose was 50 Gy in 10 fractions. The tumor response was determined by CT scans performed 3 months after the end of RT. Results: The median follow-up period after RT was 22 months. The overall survival rates at 1 and 2 years were 100% and 87.9%, respectively. Complete response (CR) was achieved in seven of 20 lesions (35%) evaluated by CT scans performed 3 months after the end of RT. In-field local control was achieved in 85% of patients. Fourteen patients (70%) developed intra-hepatic metastases. Six patients developed grade 1 nausea or anorexia during RT, and two patients had progression of ascites after RT. There was no grade 3 or greater treatment-related toxicities. Conclusions: The current study showed a favorable outcome with respect to hypofractionated RT for small HCC. Partial liver irradiation with 50 Gy in 10 fractions is considered tolerable without severe complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Li{sub x}Co{sub 0.4}Ni{sub 0.3}Mn{sub 0.3}O{sub 2} electrode materials: Electrochemical and structural studies

Graphical abstract: Evolution of the c{sub hex.}/a{sub hex.} ratio with x in LiCo{sub 1−2x}Mn{sub x}Ni{sub x}O{sub 2} solid solution showing that less Li/Ni disorder is observed for x < 0.4. Highlights: ► LiCo{sub 0.4}Ni{sub 0.3}Mn{sub 0.3}O{sub 2} is a member of the LiCo{sub 1−2x}Ni{sub x}Mn{sub x}O{sub 2} solid solution. ► Structural refinement of this cathode material shows no Li/Ni disorder. ► The rhombohedral symmetry was preserved upon lithium removal. ► The discharge capacity reached more than 140 mAh/g at 2C rate and 160 mAh/g at 1C. -- Abstract: LiCo{sub 0.4}Ni{sub 0.3}Mn{sub 0.3}O{sub 2} layered oxide in a member of the LiCo{sub 1−2x}Ni{sub x}Mn{sub x}O{sub 2} solid solution between LiCoO{sub 2} and LiNi{sub 0.5}Mn{sub 0.5}O{sub 2}. Compositions from this solid solution have attracted much attention and have been extensively studied as promising cathode candidates to replace the most popular LiCoO{sub 2} cathode material used in the commercial lithium-ion batteries (LiBs). LiCo{sub 0.4}Ni{sub 0.3}Mn{sub 0.3}O{sub 2} positive electrode material was prepared via the combustion method followed by a thermal treatment at 900 °C for 12 h. This material was characterized by a high homogeneity and a granular shape. The Rietveld refinement evidenced that the structure of this compound exhibits no Ni/Li disorder revealing that the LiCo{sub 1−2x}Ni{sub x}Mn{sub x}O{sub 2} system presents the ideal structure for LiBs application when x < 0.4. The electrochemical performances of the LiCo{sub 0.4}Ni{sub 0.3}Mn{sub 0.3}O{sub 2} sample were measured at different current rates in the 2.7–4.5 V potential range. Its discharge capacity reached 178, 161 and 145 mAhg{sup −1} at C/20, 1C and 2C, respectively. Structural changes in LiCo{sub 0.4}Ni{sub 0.3}Mn{sub 0.3}O{sub 2} upon delithiation were studied using ex situ X-ray diffraction. A continuous solid solution with a rhombohedral symmetry was detected in the whole composition range. This structural stability during the cycling combined with the obtained electrochemical features make this material convenient for the LiBs applications.

36 MATERIALS SCIENCE↗

SU-F-T-271: Comparing IMRT QA Pass Rates Before and After MLC Calibration

Purpose: To compare IMRT QA pass rates before and after an in-house MLC leaf calibration procedure. Methods: The MLC leaves and backup jaws on four Elekta linear accelerators with MLCi2 heads were calibrated using the EPID-based RIT Hancock Test as the means for evaluation. The MLCs were considered to be successfully calibrated when they could pass the Hancock Test with criteria of 1 mm jaw position tolerance, and 1 mm leaf position tolerance. IMRT QA results were collected pre- and postcalibration and analyzed using gamma analysis with 3%/3mm DTA criteria. AAPM TG-119 test plans were also compared pre- and post-calibration, at both 2%/2mm DTA and 3%/3mm DTA. Results: A weighted average was performed on the results for all four linear accelerators. The pre-calibration IMRT QA pass rate was 98.3 ± 0.1%, compared with the post-calibration pass rate of 98.5 ± 0.1%. The TG-119 test plan results showed more of an improvement, particularly at the 2%/2mm criteria. The averaged results were 89.1% pre and 96.1% post for the C-shape plan, 94.8% pre and 97.1% post for the multi-target plan, 98.6% pre and 99.7% post for the prostate plan, 94.7% pre and 94.8% post for the head/neck plan. Conclusion: The patient QA results did not show statistically significant improvement at the 3%/3mm DTA criteria after the MLC calibration procedure. However, the TG-119 test cases did show significant improvement at the 2%/2mm level.

60 APPLIED LIFE SCIENCES↗

Discrete element modeling of granular hopper flow of irregular-shaped deformable particles

Many natural and engineered granular materials have relatively deformable particles. Besides particle size and shape, particle deformability is another salient factor that significantly impacts the material’s flow behavior. Here, in this work, the flow of irregular-shaped deformable particles in a wedge-shaped hopper is investigated using discrete element simulations. A bonded-sphere model is developed to simultaneously capture irregular particle shapes and particle-wise deformations (e.g., compression, deflection, and distortion). Quantitative analysis of the effects of irregular shapes and particle deformations shows that the increase in particle stiffness tends to increase initial packing porosity and decrease the flow rate in the hopper. Rigid particles tend to have clogging issues, whereas deformable particles have less chance to, indicating particle deformation reduces the critical bridging width in the hopper flow. Detailed analysis of stress fields is also conducted to provide insights into the mechanism of particle flow and clogging. Stresses and discharge rates calculated from numerical simulations are compared and show good agreement with Walker’s theory and the extended Beverloo formula. Simulations with various particle shape combinations are also performed and show that the initial packing porosity decreases with an increasing percentage of fibers while the discharge rate has a complex dependency on particle shapes.

09 BIOMASS FUELS↗

Enhancing visible-light photocatalytic performance and stability of Ag3PO4 nanoparticles by coupling with hierarchical flower-like In2S3 microspheres

Highlights: • A hierarchical In{sub 2}S{sub 3}/Ag{sub 3}PO{sub 4} composite photocatalyst was successfully constructed. • In{sub 2}S{sub 3}/Ag{sub 3}PO{sub 4} exhibited greatly boosted visible light photocatalytic activity. • A reasonable Z-scheme charge transfer mechanism was tentatively proposed. - Abstract: In this study, hierarchical In{sub 2}S{sub 3}/Ag{sub 3}PO{sub 4} hybrid photocatalysts were successfully fabricated through an in situ chemical precipitation method and employed to the photocatalytic degradation of methyl orange (MO) under visible light irradiation. As expected, all the In{sub 2}S{sub 3}/Ag{sub 3}PO{sub 4} composites exhibited improved photocatalytic activities compared with individual Ag{sub 3}PO{sub 4} and In{sub 2}S{sub 3}. Dramatically, the optimal apparent degradation rate constant of the In{sub 2}S{sub 3}/Ag{sub 3}PO{sub 4} composite with a theoretical weight content of 4.0% In{sub 2}S{sub 3} was almost 2.3 and 1.6 times higher than that of bare Ag{sub 3}PO{sub 4} and single In{sub 2}S{sub 3}, respectively. The enhanced photocatalytic performance was mainly attributed to the formation of Z-scheme system composed of Ag{sub 3}PO{sub 4}, Ag and In{sub 2}S{sub 3}, which could not only facilitate the transfer and separation of photogenerated charge carriers, but also preserve a strong oxidation and reduction ability. Furthermore, a reasonable Z-scheme charge transfer mechanism was also proposed in detail.

36 MATERIALS SCIENCE↗

SU-E-T-431: Feasiblity of Using CT Scout Images for 2D LDR Brachytherpay Planning

Purpose: i) To show the feasibility of using CT scout images for 2D low-dose rate brachytherapy planning with BrachyVision (version 10.4); ii) to show their advantages and disadvantages over DRRs. Methods: A phantom was constructed to house a Fletcher-Suite applicator. The phantom is made of Styrofoam with metal BBs positioned at well-defined separations. These markers are used to assess the image distortion in the scout images. Unlike DRRs, scout images are distorted only in the direction normal to the couch direction; therefore, they needed to be scaled unidirectionally prior to importing into BrachyVision. In addition to confirming the scaling is performed correctly by measuring distances between well-positioned BB, we also compare a LDR plan using scout images to a 3D CT-based plan. Results: There is no distortion of the image along the couch direction due to the collimation of the CT scanner. The distortion in the transverse plane can be corrected by multiplying by the ratio of distances between source-to-isocenter and source-to-detector. The results show the distance separations between BBs as measured in scout images and by a caliber are within a few millimeters. Dosimetrically, the difference between the dose rates to points A and B based on scout images and on 3D CT are less than a few percents. The accuracy can be improved by correcting for the distortion on the transverse plane. Conclusion: It is possible to use CT scout images for 2D planning in BrachyVision. This is an advantage because scout images have no metal artifacts often present in CT images or DRRs. Another advantage is the lack of distortion in the couch direction. One major disadvantage is that the image distortion due to beam divergence can be large. This is due to the inherent short distance between source-to-isocenter and source-to-detector on a CT scanner.

60 APPLIED LIFE SCIENCES↗

WE-E-BRE-03: Biological Validation of a Novel High-Throughput Irradiator for Predictive Radiation Sensitivity Bioassays

Purpose: The large dose-response variation in both tumor and normal cells between individual patients has led to the recent implementation of predictive bioassays of patient-specific radiation sensitivity in order to personalize radiation therapy. This exciting new clinical paradigm has led us to develop a novel high-throughput, variable dose-rate irradiator to accompany these efforts. Here we present the biological validation of this irradiator through the use of human cells as a relative dosimeter assessed by two metrics, DNA double-strand break repair pathway modulation and intercellular reactive oxygen species production. Methods: Immortalized human tonsilar epithelial cells were cultured in 96-well micro titer plates and irradiated in groups of eight wells to absorbed doses of 0, 0.5, 1, 2, 4, and 8 Gy. High-throughput immunofluorescent microscopy was used to detect γH2AX, a DNA double-strand break repair mechanism recruiter. The same analysis was performed with the cells stained with CM-H2DCFDA that produces a fluorescent adduct when exposed to reactive oxygen species during the irradiation cycle. Results: Irradiations of the immortalized human tonsilar epithelial cells at absorbed doses of 0, 0.5, 1, 2, 4, and 8 Gy produced excellent linearity in γH2AX and CM-H2DCFDA with R2 values of 0.9939 and 0.9595 respectively. Single cell gel electrophoresis experimentation for the detection of physical DNA double-strand breaks in ongoing. Conclusions: This work indicates significant potential for our high-throughput variable dose rate irradiator for patient-specific predictive radiation sensitivity bioassays. This irradiator provides a powerful tool by increasing the efficiency and number of assay techniques available to help personalize radiation therapy.

60 APPLIED LIFE SCIENCES↗

Direct 2-Arm Comparison Shows Benefit of High-Dose-Rate Brachytherapy Boost vs External Beam Radiation Therapy Alone for Prostate Cancer

Purpose: To evaluate the outcomes of patients treated for intermediate- and high-risk prostate cancer with a single schedule of either external beam radiation therapy (EBRT) and high-dose-rate brachytherapy (HDRB) boost or EBRT alone. Methods and Materials: From 2001-2006, 344 patients received EBRT with HDRB boost for definitive treatment of intermediate- or high-risk prostate cancer. The prescribed EBRT dose was 46 Gy in 23 fractions, with a HDR boost of 19.5 Gy in 3 fractions. This cohort was compared to a contemporaneously treated cohort who received EBRT to 74 Gy in 37 fractions, using a matched pair analysis. Three-dimensional conformal EBRT was used. Matching was performed using a propensity score matching technique. High-risk patients constituted 41% of the matched cohorts. Five-year clinical and biochemical outcomes were analyzed. Results: Initial significant differences in prognostic indicators between the unmatched treatment cohorts were rendered negligible after matching, providing a total of 688 patients. Median biochemical follow-up was 60.5 months. The 5-year freedom from biochemical failure was 79.8% (95% confidence interval [CI], 74.3%-85.0%) and 70.9% (95% CI, 65.4%-76.0%) for the HDRB and EBRT groups, respectively, equating to a hazard ratio of 0.59 (95% CI, 0.43-0.81, P=.0011). Interaction analyses showed no alteration in HDR efficacy when planned androgen deprivation therapy was administered (P=.95), but a strong trend toward reduced efficacy was shown compared to EBRT in high-risk cases (P=.06). Rates of grade 3 urethral stricture were 0.3% (95% CI, 0%-0.9%) and 11.8% (95% CI, 8.1%-16.5%) for EBRT and HDRB, respectively (P<.0001). No differences in clinical outcomes were observed. Conclusions: This comparison of 2 individual contemporaneously treated HDRB and EBRT approaches showed improved freedom from biochemical progression with the HDR approach. The benefit was more pronounced in intermediate- risk patients but needs to be weighed against an increased risk of urethral toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-09: In Phantom Full-Implant Validation of Plastic Scintillation Detectors for in Vivo Dosimetry During Low Dose Rate Brachytherapy

Purpose: To validate in a water phantom the use of plastic scintillation detectors to measure dose to the urethra and the rectal wall during a clinically realistic low dose rate (LDR) brachytherapy implant. Methods: A template was designed to replicate a clinically realistic LDR brachytherapy prostate implant inside a water phantom. Twenty-two catheters were inserted, including one mimicking the urethra and another the rectal wall. The needles inserted in the remaining 20 catheters were composed of thin-walled nylon tubes in which I-125 radioactive seeds (Air Kerma Strengths of (0.328±0.020)U) were abutted together with plastic spacers to replicate a typical loading. A plastic scintillation detector (PSD) with a 5-mm long × 1-mm diameter sensitive element was first placed inside the urethra and 1-second measurements were performed for 60s after each needle implant. Measurements were also performed at multiple positions along the urethra once all the needles were inserted. The procedure was then repeated with the PSD placed at the rectal wall. Results: Individual dose-rates ranging from 0.07µGy/s to 1.5µGy/s were measured after each needle implant. The average absolute relative differences were (6.2±3.6)% and (6.9±6.5)% to the values calculated with the TG-43 formalism, for the urethra and rectal wall respectively. These results are within expectations from the error uncertainty budget once accounting for uncertainties in seeds’ strength and positioning. Interestingly, the PSD allowed for unplanned error detection as the study was performed. Finally, the measured dose after the full implant at different positions along the mimicked organs at risk were in agreement with TG-43 values for all of the positions tested. Conclusion: Plastic scintillation detectors could be used as in vivo detectors for LDR brachytherapy as they would provide accurate dose information after each needle implant as well as along the organs at risk at the end of the implant.

60 APPLIED LIFE SCIENCES↗

The Shifted Interface Method: A flexible approach to embedded interface computations

We propose a new embedded finite element method to simulate partial differential equations over domains with internal interfaces. Our approach belongs to the family of surrogate/approximate interface methods and relies on the idea of shifting the location and value of jump interface conditions. This choice has the goal of preserving optimal convergence rates while avoiding small cut cells and related problematic issues, typical of traditional embedded methods. The proposed approach is accurate, robust, efficient, and simple to implement. We apply this concept to internal interface computations in the context of the mixed Poisson problem, also known as the Darcy flow problem. An extensive set of numerical tests is provided to demonstrate the performance of the proposed approach.

42 ENGINEERING↗

Plasma Bubble Column Reactor: A High Throughput Reactor Design for Water Treatment

Plasma-based water treatment (PWT) is a promising technology that can degrade various emerging contaminants. However, PWT application on an industrially viable scale is hindered by the lack of an efficient reactor design that combines enhanced plasma-liquid contact with high liquid throughput. This work investigates the applicability of a bubble column gas-liquid contactor to PWT. A pulsed plasma bubble column reactor (PBCR) with a concentric rod-cylinder electrode configuration was used to correlate contaminant removal performance with the gas-liquid contact parameters of the bubble column. A surfactant, rhodamine B dye, and a nonsurfactant, caffeine, were used as model contaminants at µM concentration levels. The bubble column characteristics, i.e., gas holdup, bubble size distribution, and gas-liquid area, were measured as a function of superficial gas velocity using image-based methods. Degradation rates of both contaminants increased with gas flowrate. For caffeine, the increase was attributed to intensified bulk liquid mixing, while dye degradation increased due to the increased gas-liquid area. Ultimately, we show that bubble column contactors significantly improve the utilization of plasma-generated reactive species toward contaminant degradation by distributing them over a large contact area. As a result, a better match between the plasma species interfacial flux and the interfacial contaminant concentration leads to improved treatment energy efficiency. Furthermore, typical degradation energy efficiencies were ~10 g/kWh for caffeine and ~60 g/kWh for rhodamine B.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗