Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PLUGGING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Analysis of ZTE MRI application to sandstone and carbonate

Micro-tomography (μCT) and nuclear magnetic resonance (NMR) have been used to characterize porous media for decades. Here, Magnetic Resonance Imaging (MRI) enables direct visualization of pore architecture and many pulse sequences exist. In this work, we tested the MRI pulse sequence Zero Echo Time (ZTE) to study sandstone and carbonate for its ability to address short relaxation times. We aimed at resolving two fluid conduit scales, i.e. pores and fractures. In this research, we study tighter porous systems than those previously reported using ZTE. Additionally, Pore Cluster Analysis (PCA), combined with ZTE, can be used to analyze pore-fracture connectivity of relatively large core plugs. We show that ZTE can resolve two-scale pore systems simultaneously, i.e. fractures and pores. By combining Time-Domain NMR pore-size analysis and PCA, we show that careful selection of resolution is necessary to understand transport in porous media.

02 PETROLEUM↗

Dilution-Free Analysis from Picoliter Droplets by Nano-Electrospray Ionization Mass Spectrometry

The expanding role of microfluidics for chemical and biochemical analysis is due to factors including the favorable scaling of separation performance with reduced channel dimensions,[1] flexibility afforded by computer-aided device design, and the ability to integrate multiple sample handling and analysis steps into a single platform.[2] Such devices enable smaller liquid volumes and sample sizes to be handled than can be achieved on the benchtop, where sub-microliter volumes are difficult to work with and where sample losses to the surfaces of multiple reaction vessels become prohibitive. A particularly attractive microfluidic platform for sample-limited analyses employs aqueous droplets or plugs encapsulated by an immiscible oil.[3,4] Each droplet serves as a discrete compartment or reaction chamber enabling, e.g., high throughput screening[5,6] and kinetic studies[7-9] of femto- to nanoliter samples, as well as the encapsulation[10-12] and lysis[10] of individual cells with limited dilution of the cellular contents

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CuS and Cu 2 S as Cathode Materials for Lithium Batteries: A Review [A Review on CuS and Cu 2 S as Cathode Materials for Lithium Batteries]

Nowadays, lithium-ion batteries (LIBs) take a very important role for energy storage. LIBs are dominant in consumer electronics, and they have also entered the market of hybrid electric vehicles (HEVs), plug-in HEVs, and pure EVs. However, state-of-the-art LIBs are electrochemically intercalation-based and are still limited in energy density and power rates. To address these challenges and others (e. g. safety issues and cost), conversion-based copper sulfides (Cu x S, 1≤x≤2) have been investigated as alternative cathodes for improved electrochemical performance, that is, higher energy density, better cycling stability, and enhanced rate capability. In this paper, we summarize the recent research progress on Cu x S to gain a better understanding of the material's electrochemical mechanisms and develop feasible strategies for improving its performance.

25 ENERGY STORAGE↗

A Pipeline Transport Correlation for Slurries with Small but Dense Particles

Most correlations/models for minimum transport or critical velocity of slurry were developed for slurries composed of particles greater than ~100-200 µm diameter with narrow particle-size distributions which is typical of the minerals industry. Many other process industries handle smaller particles. In particular waste slurries at the U.S. Department of Energy's Hanford Site have broad size distributions and significant fractions of smaller particles. Despite the size of these wastes, recent PNNL studies indicate that the small particles might be of sufficient density to pose a significant risk for pipeline deposition and plugging. To allow predictive assessment of deposition of fine dense particles for waste slurry transport at the U.S. DOE Hanford site, a pipeline-transport correlation for critical velocity was developed using a simple power-law between two dimensionless numbers important for slurry transport, the deposition Froude and Archimedes numbers. The correlation accords well with experimental data for slurries with Archimedes numbers <80 and is an adequate pipeline design guide for processing Hanford waste slurry.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effectiveness of purging on preventing gas emission buildup in wood pellet storage

Storage of wood pellets has resulted in deadly accidents in connection with off-gassing and self-heating. A forced ventilation system should be in place to sweep the off-gases and control the thermal conditions. In this study, multiple purging tests were conducted in a pilot scale silo to evaluate the effectiveness of a purging system and quantify the time and volume of the gas needed to sweep the off-gases. To identify the degree of mixing, residence time distribution of the tracer gas was also studied experimentally. Large deviations from plug flow suggested strong gas mixing for all superficial velocities. As the velocity increased, the system dispersion number became smaller, which indicated less degree of mixing with increased volume of the purging gas. Finally, one-dimensional modelling and numerical simulation of the off-gas concentration profile gave the best agreement with the measured gas concentration at the bottom and middle of the silo.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, no sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed.

59 BASIC BIOLOGICAL SCIENCES↗

CO 2 mineralization in volcanogenic sandstones: geochemical characterization of the Etchegoin formation, San Joaquin Basin

Abstract Volcanogenic sandstones are typically rich in volcanic rock fragments that can provide reactive minerals for CO 2 mineralization in a scenario of CO 2 sequestration. To quantitatively evaluate the extent and time scale of CO 2 mineralization in potential reservoir formations, we characterized example high‐porosity volcanic sand from the San Joaquin Valley of southern Central California. Samples were collected from the volcanic‐rich members of the Etchegoin Formation in the San Joaquin Basin near Coalinga, California. Thin sections made from these samples were examined under petrographic microscope to identify mineral compositions, and then scanning electron microscopy (SEM) and energy dispersive x‐ray spectroscopy (EDX) were used to gather quantitative information on mineral abundances, distribution, and reactive surface areas. Porosity and permeability were also measured using core plugs made from outcrop samples. Results show that the Etchegoin volcanic sandstone has a high percentage (10–15%) of reactive minerals (pyroxenes, Fe‐Ti spinel and clays), and high reactive surface areas at about 1 m 2 /kg. Reactive transport modeling is conducted and shows that these reactive minerals could mineralize 92% of injected and capillary‐trapped CO 2 within 1000 years of injection. Possible effects of heterogeneity on CO 2 injection and mineralization are also studied using the reactive transport code TOUGHREACT. Vertical heterogeneity of mineralogy and hydrology increases both CO 2 injectivity and mineralization. Available volcanogenic sandstones worldwide like the Etchegoin sandstone are summarized from the literature, with formations from the western USA that have CO 2 sequestration potential emphasized.© 2015 Society of Chemical Industry and John Wiley & Sons, Ltd

Zhang, Shuo↗

eSHAFTS: Integrated and graphical drug design software based on 3D molecular similarity

With the development of computer technology, computer‐aided drug design (CADD) has become an important means for drug research and development, and its representative method is virtual screening. Various virtual screening platforms have emerged in an endless stream and play great roles in the field of drug discovery. With the increasing number of compound molecules, virtual screening platforms face two challenges: low fluency and low visibility of software operations. In this article, we present an integrated and graphical drug design software eSHAFTS based on three‐dimensional (3D) molecular similarity to overcome these shortcomings. Compared with other software, eSHAFTS has four main advantages, which are integrated molecular editing and drawing, interactive loading and analysis of proteins, multithread and multimode 3D molecular similarity calculation, and multidimensional information visualization. Experiments have verified its convenience, usability, and reliability. By using eSHAFTS, various tasks can be submitted and visualized in one desktop software without locally installing any dependent plug‐ins or software. The software installation package can be downloaded for free at http://lilab.ecust.edu.cn/home/resource.html . © 2019 Wiley Periodicals, Inc.

He, Gaoqi↗

Plant science decadal vision 2020–2030: Reimagining the potential of plants for a healthy and sustainable future

Abstract Plants, and the biological systems around them, are key to the future health of the planet and its inhabitants. The Plant Science Decadal Vision 2020–2030 frames our ability to perform vital and far‐reaching research in plant systems sciences, essential to how we value participants and apply emerging technologies. We outline a comprehensive vision for addressing some of our most pressing global problems through discovery, practical applications, and education. The Decadal Vision was developed by the participants at the Plant Summit 2019, a community event organized by the Plant Science Research Network. The Decadal Vision describes a holistic vision for the next decade of plant science that blends recommendations for research, people, and technology. Going beyond discoveries and applications, we, the plant science community, must implement bold, innovative changes to research cultures and training paradigms in this era of automation, virtualization, and the looming shadow of climate change. Our vision and hopes for the next decade are encapsulated in the phrase reimagining the potential of plants for a healthy and sustainable future. The Decadal Vision recognizes the vital intersection of human and scientific elements and demands an integrated implementation of strategies for research (Goals 1–4), people (Goals 5 and 6), and technology (Goals 7 and 8). This report is intended to help inspire and guide the research community, scientific societies, federal funding agencies, private philanthropies, corporations, educators, entrepreneurs, and early career researchers over the next 10 years. The research encompass experimental and computational approaches to understanding and predicting ecosystem behavior; novel production systems for food, feed, and fiber with greater crop diversity, efficiency, productivity, and resilience that improve ecosystem health; approaches to realize the potential for advances in nutrition, discovery and engineering of plant‐based medicines, and "green infrastructure." Launching the Transparent Plant will use experimental and computational approaches to break down the phytobiome into a "parts store" that supports tinkering and supports query, prediction, and rapid‐response problem solving. Equity, diversity, and inclusion are indispensable cornerstones of realizing our vision. We make recommendations around funding and systems that support customized professional development. Plant systems are frequently taken for granted therefore we make recommendations to improve plant awareness and community science programs to increase understanding of scientific research. We prioritize emerging technologies, focusing on non‐invasive imaging, sensors, and plug‐and‐play portable lab technologies, coupled with enabling computational advances. Plant systems science will benefit from data management and future advances in automation, machine learning, natural language processing, and artificial intelligence‐assisted data integration, pattern identification, and decision making. Implementation of this vision will transform plant systems science and ripple outwards through society and across the globe. Beyond deepening our biological understanding, we envision entirely new applications. We further anticipate a wave of diversification of plant systems practitioners while stimulating community engagement, underpinning increasing entrepreneurship. This surge of engagement and knowledge will help satisfy and stoke people's natural curiosity about the future, and their desire to prepare for it, as they seek fuller information about food, health, climate and ecological systems.

59 BASIC BIOLOGICAL SCIENCES↗

OpenGraphGym: A Parallel Reinforcement Learning Framework for Graph Optimization Problems

This paper presents an open-source, parallel AI environment (named OpenGraphGym) to facilitate the application of reinforcement learning (RL) algorithms to address combinatorial graph optimization problems. This environment incorporates a basic deep reinforcement learning method, and several graph embeddings to capture graph features, it also allows users to rapidly plug in and test new RL algorithms and graph embeddings for graph optimization problems. This new open-source RL framework is targeted at achieving both high performance and high quality of the computed graph solutions. This RL framework forms the foundation of several ongoing research directions, including 1) benchmark works on different RL algorithms and embedding methods for classic graph problems; 2) advanced parallel strategies for extreme-scale graph computations, as well as 3) performance evaluation on real-world graph solutions.

Zheng, Weijian↗

Cometabolic Bioremediation

Cometabolic bioremediation is probably the most underappreciated bioremediation strategy currently available. Cometabolism strategies stimulate only indigenous microbes with the ability to degrade the contaminant and cosubstrate, e.g., methane, propane, toluene, and others. This highly targeted stimulation insures that only those microbes that can degrade the contaminant are targeted, thus reducing amendment costs, well and formation plugging, etc. Cometabolic bioremediation has been used on some of the most recalcitrant contaminants, e.g., PCE, TCE, MTBE, TNT, dioxane, atrazine. Methanotrophs have been demonstrated to produce methane monooxygenase, an oxidase that can degrade over 1000 compounds. Cometabolic bioremediation also has the advantage of being able to degrade contaminants to trace concentrations, since the biodegrader is not dependent on the contaminant for carbon or energy. In the Gulf of Mexico and in the Arctic Tundra, we have recently found that natural attenuation can be a cometabolic process also. Increasingly we are finding that in order to protect human health and the environment that we must remediate to lower and lower concentrations, especially for compounds like endocrine disrupters and trace organics, thus cometabolism may be the best and may be the only possibility that we have to bioremediate some contaminants.

Hazen, Terry C.↗

The lightcone bootstrap and the spectrum of the 3d Ising CFT

In this paper. we compute numerically the dimensions and OPE coefficients of several operators in the 3d Ising CFT, and then try to reverse-engineer the solution to crossing symmetry analytically. Our key tool is a set of new techniques for computing infinite sums of SL(2,R) conformal blocks. Using these techniques, we solve the lightcone bootstrap to all orders in an asymptotic expansion in large spin, and suggest a strategy for going beyond the large spin limit. We carry out the first steps of this strategy for the 3d Ising CFT, deriving analytic approximations for the dimensions and OPE coefficients of several infinite families of operators in terms of the initial data $\{\Delta_\sigma,\Delta_\epsilon,f_{\sigma\sigma\epsilon},f_{\epsilon\epsilon\epsilon},c_T\}$. The analytic results agree with numerics to high precision for about 100 low-twist operators (correctly accounting for O(1) mixing effects between large-spin families). Plugging these results back into the crossing equations, we obtain approximate analytic constraints on the initial data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Embolization of the Internal Iliac Artery: Cost-Effectiveness of Two Different Techniques

The purpose of this study was to compare the cost-effectiveness of coils versus the Amplatzer Vascular Plug (AVP) for occlusion of the internal iliac artery (IAA). Between 2002 and January 2006, 13 patients (mean age 73 {+-} 13 years) were referred for stent-grafting of abdominal aortic aneurysm (n = 6); type I distal endoleak (n = 3), isolated iliac aneurysm (n = 3), or rupture of a common iliac aneurysm (n = 1). In all patients, extension of the stent-graft was needed because the distal neck was absent. Two different techniques were used to occlude the IIA: AVP in seven patients (group A) and coil embolization in six patients (group C). Immediate results and direct material costs were assessed retrospectively. Immediate success was achieved in all patients, and simultaneous stent-grafting was successfully performed in two of six patients in group C versus five of seven patients in group A. In all group A patients, a single AVP was sufficient to achieve occlusion of the IIA, accounting for a mean cost of 485 Euro , whereas in group C patients, an average of 7 {+-} 3 coils were used, accounting for a mean cost of 1,745 Euro . Mean average cost savings using the AVP was 1,239 Euro . When IIA occlusion is needed, the AVP allows a single-step procedure at significant cost savings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Testing Percutaneous Arterial Closure Devices: An Animal Model

The ovine superficial femoral artery was used for testing the efficacy of percutaneous arterial closure devices (PACDs) in their developmental stage. Two topical devices containing chitostan, one staple-mediated PACD and a porcine small intestinal submucosa plug, were tested by follow-up angiography in 37 sheep. Absence or presence of bleeding and time to bleeding cessation were the main criteria for evaluation of PAVD efficacy. The results of these tests directed modification of individual PACDs and improved their efficacy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Obesity: An Independent Risk Factor for Insufficient Hemostasis Using the AngioSeal Vascular Closure Device After Antegrade Puncture

Purpose: This study was designed to investigate the efficacy of the AngioSeal vascular closure device after antegrade puncture of the femoral artery. Methods: In a prospective study, 120 consecutive patients underwent lower limb vascular intervention by an antegrade access to the common femoral artery (CFA). After intervention, a 6F (n = 88) or an 8F (n = 32) AngioSeal vascular closure device was used to achieve hemostasis. The technical success or the cause of failure was documented. In addition, the coagulation status (platelets, INR, prothrombin time, atrial thromboplastin time (PTT)), hypertonus, locoregional habitus of the groin, body mass index (BMI), presence of calcifications, and history of previous surgical interventions of the CFA were evaluated. Results: Hemostasis was achieved in 97 patients (81%). In 12 patients (10%), persistent bleeding of the puncture site required manual compression. In another nine patients (8%) a kink of the sheath obviated the passage of the collagen plug toward the vessel, and in two patients the anchor dislodged out of the vessel, requiring manual compression. There were no significant differences between the groups of successful and unsuccessful sealing regarding the mean platelets (241 vs. 254 * 10{sup 9}/l; P = 0.86), INR (1.06 vs. 1.02; P = 0.52), prothrombin time (90% vs. 90%; P = 0.86), and PTT (30 vs. 31 s; P = 0.82). However, unsuccessful sealing was more likely in obese patients with an increased BMI (26.6 vs. 28.8 kg/m{sup 2}; P = 0.04). Conclusions: Obesity seems to be an independent risk factor for insufficient sealing using the AngioSeal vascular closure device after antegrade puncture of the CFA. In 8% of our patients, hemostasis could not be achieved due to kink of the flexible sheath.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transsplenic Access to the Portal Vein for Management of Vascular Complication in Patients with Chronic Liver Disease

Purpose: To evaluate the safety and feasibility of percutaneous transsplenic access to the portal vein for management of vascular complication in patients with chronic liver diseases. Methods: Between Sept 2009 and April 2011, percutaneous transsplenic access to the portal vein was attempted in nine patients with chronic liver disease. Splenic vein puncture was performed under ultrasonographic guidance with a Chiba needle, followed by introduction of a 4 to 9F sheath. Four patients with hematemesis or hematochezia underwent variceal embolization. Another two patients underwent portosystemic shunt embolization in order to improve portal venous blood flow. Portal vein recanalization was attempted in three patients with a transplanted liver. The percutaneous transsplenic access site was closed using coils and glue. Results: Percutaneous transsplenic splenic vein catheterization was performed successfully in all patients. Gastric or jejunal varix embolization with glue and lipiodol mixture was performed successfully in four patients. In two patients with a massive portosystemic shunt, embolization of the shunting vessel with a vascular plug, microcoils, glue, and lipiodol mixture was achieved successfully. Portal vein recanalization was attempted in three patients with a transplanted liver; however, only one patient was treated successfully. Complete closure of the percutaneous transsplenic tract was achieved using coils and glue without bleeding complication in all patients. Conclusion: Percutaneous transsplenic access to the portal vein can be an alternative route for portography and further endovascular management in patients for whom conventional approaches are difficult or impossible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Celiac Injury Due to Arcuate Ligament: An Endovascular Approach

Celiac trunk injures are rare events, with high mortality rates and difficult management. Endovascular treatment may be considered to avoid bleeding. We report a case of severe bleeding in a 37-year-old man resulting from celiac trunk stretching after a motorcycle crash. Because direct celiac trunk catheterization was not possible, a retrograde catheterization of the common hepatic artery was performed via the superior mesenteric artery. Two vascular plugs (type IV) were released, and the exclusion of the celiac trunk origin was completed with the deployment of an aortic cuff. The patient's clinical condition immediately improved, and after 6 months' follow-up, imaging confirmed the complete exclusion of the celiac trunk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Suitability of Exoseal Vascular Closure Device for Antegrade Femoral Artery Puncture Site Closure

Purpose. To assess the efficacy and safety of the Exoseal vascular closure device for antegrade puncture of the femoral artery. Methods. In a prospective study from February 2011 to January 2012, a total of 93 consecutive patients received a total of 100 interventional procedures via an antegrade puncture of the femoral artery. An Exoseal vascular closure device (6F) was used for closure in all cases. Puncture technique, duration of manual compression, and use of compression bandages were documented. All patients were monitored by vascular ultrasound and color-coded duplex sonography of their respective femoral artery puncture site within 12 to 36 h after angiography to check for vascular complications. Results. In 100 antegrade interventional procedures, the Exoseal vascular closure device was applied successfully for closure of the femoral artery puncture site in 96 cases (96 of 100, 96.0 %). The vascular closure device could not be deployed in one case as a result of kinking of the vascular sheath introducer and in three cases because the bioabsorbable plug was not properly delivered to the extravascular space adjacent to the arterial puncture site, but instead fully removed with the delivery system (4.0 %). Twelve to 36 h after the procedure, vascular ultrasound revealed no complications at the femoral artery puncture site in 93 cases (93.0 %). Minor vascular complications were found in seven cases (7.0 %), with four cases (4.0 %) of pseudoaneurysm and three cases (3.0 %) of significant late bleeding, none of which required surgery. Conclusion. The Exoseal vascular closure device was safely used for antegrade puncture of the femoral artery, with a high rate of procedural success (96.0 %), a low rate of minor vascular complications (7.0 %), and no major adverse events.

62 RADIOLOGY AND NUCLEAR MEDICINE↗