Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PERMANENT MAGNETS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Effect of oxygen potential on Co solubility limit in La–Co co-substituted magnetoplumbite-type strontium ferrite

Highlights: • Oxygen pressure control dramatically affect the substitution range of La–Co co-substituted Sr M-type hexaferrite. • Successful synthesis of LaFe{sub 11}CoO{sub 19} under high oxygen pressure. • LaFe{sub 11}CoO{sub 19} achieves the highest anisotropic field. - Abstract: La–Co co-substituted magnetoplumbite-type (M-type) strontium ferrite is typically used as a base material for high-performance hard ferrite magnets. Generally, the unquenched orbital moment of Co{sup 2+}, substituted for Fe{sup 3+}, is thought to enhance magnetic anisotropy and then coercivity. La{sup 3+} is substituted for Sr{sup 2+} to compensate for the charge unbalance associated with Co{sup 2+} substitution. Even if the synthesis starts with equal amounts of Co and La, the Co contents of the resulting samples are generally lower than the La contents because of the partial reduction of Fe{sup 3+} to Fe{sup 2+}. We studied how the oxygen potential suppresses the formation of Fe{sup 2+} and expands the Co solubility range in this system. Polycrystalline samples, synthesized under oxygen partial pressures of 0.2, 1.0, and 387 atm, were characterized by powder X-ray diffraction, wavelength-dispersive X-ray analysis, and magnetization measurements. We reveal that the application of higher oxygen pressure dramatically expands the Co solubility range, resulting in the enhancement in magnetic anisotropy. We successfully synthesized Sr-free LaFe{sub 11}CoO{sub 19} with high magnetic anisotropy using the hot isostatic pressure (HIP) technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetization reversal mechanism of a sintered Nd-Fe-B magnet with Dy segregation

The magnetization reversal mechanism of a sintered Nd-Fe-B magnet with Dy segregation near grain boundaries (GB) was studied using spin polarized scanning electron spectroscopy and magnetization measurements. More fine magnetic domains near GB were found in the magnet with Dy segregation than in the magnet without treatment. Magnetic modifications near the GB had no effect on the magnetization development. The domain wall motion of a quasihard magnetic component in the magnet with Dy segregation was suppressed in comparison with those in the magnet without treatment; this could also be confirmed in the different behaviors of asymmetry components toward a magnetic field direction between both magnets. From analyzing the probability of rotating magnetization near the GB, the magnetization reversal of the magnet with Dy segregation was more difficult to produce than those of the magnet without treatment.

36 MATERIALS SCIENCE↗

Optimization of a Packed Particle Magnetocaloric Refrigerator: A Combined Experimental and Theoretical Study

Magnetocaloric refrigeration has strong potential towards achieving high efficiency hydrogen liquefaction. Optimising parameters such as particle size and operating cycles can have a significant impact on liquefaction performance. Here, this work reports on a room temperature magnetocaloric refrigeration prototype designed with helium as the heat transfer fluid and packed particle Gd 0.8875 Ce 0.1025 Si 0.84 Cr 0.19 as the refrigerant. The temperature spans and cooling power with three different particle sizes at two different operating cycles were measured. A maximum temperature span of 16.7 K and a maximum cooling power of 8.6 W·kg –1 were obtained. Reduction of performance in the faster cycle was observed in larger particles due to insufficient thermal diffusion time and its implications for cryogenic temperatures are discussed. A numerical model was developed based on the experimentally observed variation of the temperature span and cooling power with particle size and cycle duration. This model was then used to study the competing effects of viscous dissipation and thermal diffusion for different particle sizes and cycle durations.

08 HYDROGEN↗

FePt:C/Fe graded and nongraded films with controllable coercivity fabricated by magnetron sputtering and postannealing

Graded and nongraded FePt:C(hard)/Fe(soft) films with different structures are fabricated by magnetron sputtering and postannealing. Due to the interdiffusion between FePt and C layers during the annealing process, films with a continuous variation in anisotropy are realized by varying the C concentration in the FePt hard layer. In comparison to the FePt/Fe bilayer, the coercivities of graded and nongraded films are effectively reduced. However, the mechanisms of reduction are different. Moreover, adding a nonmagnetic C layer not only tailors the gradient of anisotropy, but also weakens the intergranular exchange interaction.

36 MATERIALS SCIENCE↗

Energy Differential Response of Cancer Cells for Low Dose Irradiation:Impact of Monoenergetic Brachytherapy Sources

Purpose: The purpose of this work was to evaluate the energy differential response of cancer cells under identical dose exposure to asses the relevancy of mono-energetic sources for Brachytherapy treatments. Method and Materials: An electron energy spectrum impinging on lived breast cancer cell lines (MDA321) was obtained by placing a 19.65 {micro}Ci {sup 90}Sr/{sup 90}Y radioactive source in front of a non-uniform magnetic field constructed from two 5.08 x 5.0 cm x 2.54 cm neodimium ion permanent dipole magnets with a 1 cm separation gap. The cell lines were placed on the exit pole face of the magnet and were subsequently irradiated with different electron energies ranging from about 0.75 MeV to 1.85 MeV. The energy distribution was accurately measured with a scintillating fiber detector system that provided a 0.5% agreement with ICRU and a 5% energy resolution. The dosimetry was performed using a series of data acquired with a {sup 9}Sr/{sup 90}Y 4.5 mCi SIA-6 eye applicator, 6-21 MeV fixed energies from a Varian 2100 EX linac, EBT Gafchromic and Kodak ERT2 films, and an ion chamber detector. The accuracy of the dose rate obtained at different locations along and away from the magnet inside the cell containers was within 10.7%. Results: The cell lines were irradiated with a 0.5-4 Gy dose range. The data indicate a very strong differential energy response for electrons around 1 MeV (more lethal) compare to those with lesser or greater energy and a survival rate of at most 10% at very low dose (0.5-2 Gy). Conclusion: Mono-energetic Brachytherapy sources may provide a new pathway for radio-therapy treatment optimizations following a dedicated study showing very unusual high lethality in a specific energy window for MDA321 breast cancer cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Renewal Plan for the Advanced Photon Source

With coordination from the APS Renewal Steering Committee (the members of which are the co-authors of this paper), staff and users of the U.S. Department of Energy's Advanced Photon Source (APS) at Argonne National Laboratory are in the process of developing a renewal plan for the facility. The renewal is a coordinated upgrade of the accelerator, beamlines, and associated technical structure that will enable users of the APS to address key scientific challenges in the coming decades. The cost of the renewal is estimated to be from $300M to $400M and to take approximately six years from start to finish.

43 PARTICLE ACCELERATORS↗

Study on corrosion behaviors of sintered Nd-Fe-B magnets in different environmental conditions

Nd-Fe-B magnets have outstanding magnetic properties, but their corrosion resistance is poor because the rare-earth-rich phases in them are easily oxidized. In this article, we report an investigation of the corrosion behaviors of sintered Nd-Fe-B magnets with varied compositions in different corrosion conditions. The weight losses of the magnets after corrosion testing were measured after brushing off the corrosion products. The magnetic flux losses of the magnets were measured using a fluxmeter. A scanning electron microscope equipped with an energy dispersive x-ray analysis system was employed to observe the corrosion morphology. It was found that the humid-heat resistance of the magnets was obviously improved by partially substituting Dy for Nd and adding minor Co. The corrosion products and morphologies of Nd-Fe-B magnets for the autoclave test were different from those for the constant humid-heat test. The corrosion rates of the magnets for the former were much slower than for the latter; this is probably because the high-pressure steam led to an oxygen-deficient atmosphere, and the liquid film on the surface of the magnet specimens hindered the diffusion of oxygen into the bulk for the autoclave test.

36 MATERIALS SCIENCE↗

Anisotropy induced large exchange bias behavior in ball milled Ni-Co-Mn-Sb alloys

We report the effect of decrease in the grain size on the structural, magnetic and exchange bias (EB) behavior in ball milled Ni{sub 50-x}Co{sub x}Mn{sub 38}Sb{sub 12} (x=0 and 5) Heusler alloys. The existence of a wide range of grain sizes in the ball milled samples results in dramatic changes in the structural and magnetic properties. For x=0, a large EB field of 3.2 kOe is observed in the ball milled sample, compared to a value of 245 Oe of the bulk sample. This increase is attributed to the enhanced exchange coupling between the soft and hard magnetic particles.

36 MATERIALS SCIENCE↗

Electroplating hard magnetic SmCo for magnetic microactuator applications

Patterned SmCo thin films were electroplated from an aqueous solute containing glycine by using dc and pulse dc current on the beaker level. Micromolds prepared by photolithography allow an accurate pattern transfer for patterned deposition of the material. A flux guide of a magnetic microactuator was chosen as a pattern, and Al{sub 2}O{sub 3} was used as the substrate. Au and Cr were investigated as seed layer materials. The content of Sm in the SmCo films is strongly dependent on the applied cathodic current density. A relative Sm content of up to 13.8 at. % could be determined by energy dispersive x-ray (EDX) spectroscopy. The SmCo thin films were annealed at 560 deg. C in a vacuum oven. Vibrating sample magnetometer (VSM) measurements were applied to characterize the magnetic properties. This film features hard magnetic properties with an intrinsic coercivity H{sub ci} of up to 44 kA/m. Electron probe microanalysis (EPMA) measurements showed that up to 40 at. % of O may be integrated in these films. The phases in the deposited films were determined by applying X-ray diffraction (XRD) measurements. These films consist of a mixture of SmCo alloy, Sm oxide, and Co.

36 MATERIALS SCIENCE↗

Medium grain niobium SRF cavity production technology for science frontiers and accelerator applications

Herein we present the cost-effective production of superconducting radio frequency (SRF) cavities made of medium grain (MG) niobium (Nb) discs directly sliced from forged and annealed billet. This production method provides clean surface conditions and reliable mechanical characteristics with sub-millimeter average grain size resulting in stable SRF cavity production. We propose to apply this material to particle accelerator in the science and industrial applications. The science applications require high field gradients(≥ 30 MV/m) particularly in pulsed mode. The industrial applications require high $Q_0$ values with moderate gradients (~ 20 MV/m) in CW mode operation. This paper describes the MG Nb disc production recently demonstrated and discusses future prospects for application in advanced particle accelerators in the science and industrial applications.

47 OTHER INSTRUMENTATION↗

Building America Top Innovations 2013 Profile – High-Performance Furnace Blowers

This Top Innovations profile describes Lawrence Berkeley National Laboratory's work with furnace blower design that led to the creation of a standard for rating blowers, credits for the use of good blowers in Federal tax credit programs and energy codes, and consideration in current federal rulemaking procedures.

air conditioner↗

A polyvalent harmonic coil testing method for small-aperture magnets

A method to characterize permanent and fast-pulsed iron-dominated magnets with small apertures is presented. The harmonic coil measurement technique is enhanced specifically for small-aperture magnets by (1) in situ calibration, for facing search-coil production inaccuracy, (2) rotating the magnet around its axis, for correcting systematic effects, and (3) measuring magnetic fluxes by stationary coils at different angular positions for measuring fast pulsed magnets. This method allows a quadrupole magnet for particle accelerators to be characterized completely, by assessing multipole field components, magnetic axis position, and field direction. In this paper, initially the metrological problems arising from testing small-aperture magnets are highlighted. Then, the basic ideas of the proposed method and the architecture of the corresponding measurement system are illustrated. Finally, experimental validation results are shown for small-aperture permanent and fast-ramped quadrupole magnets for the new linear accelerator Linac4 at CERN (European Organization for Nuclear Research).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure-property relationship of nanocrystalline Pr{sub 2}Co{sub 14}B-based hard magnetic film

Nanocrystalline Pr{sub 2}Co{sub 14}B-based films are deposited on two types of substrates at 600 deg. C by radio frequency magnetron sputtering. All samples are composed of a hard magnetic phase Pr{sub 2}Co{sub 14}B and a small amount of a soft magnetic phase Co{sub 3}B. The film sputtered on the thermally oxidized silicon wafer has a more dispersed distribution of Co{sub 3}B and a smaller average grain size of Pr{sub 2}Co{sub 14}B than that deposited on alumina substrates; therefore, the former film shows a stronger intergrain exchange coupling action (IECA) than the latter film. In addition, the coercivity (8.6 kOe) and ratio (0.68) of remanence to saturation magnetization of the film sputtered on thermally oxidized silicon wafers are considerably higher than those (0.4 kOe and 0.56) of the film deposited on alumina substrates. In the case of the film sputtered on alumina substrates, the size of most magnetic domains is comparable to the average grain size of magnetic phases, implying the occurrence of a weak IECA. However, in the case of the film sputtered on thermally oxidized silicon wafers, the size of most magnetic domains is considerably larger than the mean grain size of magnetic phases, indicating the occurrence of a strong IECA. The effect of the IECA on the coercivity of specimens is determined by analyzing the temperature dependence of coercivity in the framework of a nucleation model.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Technological developments and accelerator improvements for the FRIB beam power ramp-up

The Facility for Rare Isotope Beams (FRIB) began operation with 1 kW beam power for scientific users in May 2022 upon completion of 8 years of project construction. The ramp-up to the ultimate beam power of 400 kW, planned over a 6-year period, will enable the facility to reach its full potential for scientific discovery in isotope science and applications. In December 2023, a record-high beam power of 10.4 kW uranium was delivered to the target. Technological developments and accelerator improvements are being made over the entire facility and are key to completion of the power ramp-up. Major technological developments entail the phased deployment of high-power beam-intercepting systems, including the charge strippers, the charge selection systems, the production target, and the beam dump, along with support systems, including non-conventional utilities (NCU) and remote handling facilities. Major accelerator improvements include renovations to aging legacy systems associated with experimental beam lines and system automation for improved operational efficiency and better machine availability. Experience must be gained to safely handle the increased radiological impacts associated with high beam power; extensive machine studies and advanced beam tuning procedures are needed to minimize uncontrolled beam losses for the desired operating conditions. This paper discusses the technological developments and accelerator improvements with emphasis on major R&D efforts.

43 PARTICLE ACCELERATORS↗

Solid core dipoles and switching power supplies: Lower cost light sources?

As a result of improvements in power semiconductors, moderate frequency switching supplies can now provide the hundreds of amps typically required by accelerators with zero-to-peak noise in the kHz region ~ 0.06% in current or voltage mode. Modeling was undertaken using a finite electromagnetic program to determine if eddy currents induced in the solid steel of CEBAF magnets and small supplemental additions would bring the error fields down to the 5ppm level needed for beam quality. The expected maximum field of the magnet under consideration is 0.85 T and the DC current required to produce that field is used in the calculations. An additional 0.1% current ripple is added to the DC current at discrete frequencies 360 Hz, 720 Hz or 7200 Hz. Over the region of the pole within 0.5% of the central integrated BdL the resulting AC field changes can be reduced to less than 1% of the 0.1% input ripple for all frequencies, and a sixth of that at 7200 Hz. Doubling the current, providing 1.5 T central field, yielded the same fractional reduction in ripple at the beam for the cases checked. A small dipole was measured at 60, 120, 360 and 720 Hz in two conditions and the results compared to the larger model for the latter two frequencies with surprisingly good agreement. Thus, for light sources with aluminum vacuum vessels and full energy linac injection, the combination of solid core dipoles and switching power supplies may result in significant cost savings.

acceleration cavities and magnets superconducting ↗

The KATRIN superconducting magnets: Overview and first performance results

The KATRIN experiment aims for the determination of the effective electron anti-neutrino mass from the tritium beta-decay with an unprecedented sub-eV sensitivity. The strong magnetic fields, designed for up to 6 T, adiabatically guide β-electrons from the source to the detector within a magnetic flux of 191 Tcm 2 . A chain of ten single solenoid magnets and two larger superconducting magnet systems have been designed, constructed, and installed in the 70-m-long KATRIN beam line. The beam diameter for the magnetic flux varies from 0.064 m to 9 m, depending on the magnetic flux density along the beam line. Two transport and tritium pumping sections are assembled with chicane beam tubes to avoid direct "line-of-sight" molecular beaming effect of gaseous tritium molecules into the next beam sections. The sophisticated beam alignment has been successfully cross-checked by electron sources. In addition, magnet safety systems were developed to protect the complex magnet systems against coil quenches or other system failures. The main functionality of the magnet safety systems has been successfully tested with the two large magnet systems. The complete chain of the magnets was operated for several weeks at 70% of the design fields for the first test measurements with radioactive krypton gas. The stability of the magnetic fields of the source magnets has been shown to be better than 0.01% per month at 70% of the design fields. This paper gives an overview of the KATRIN superconducting magnets and reports on the first performance results of the magnets.

47 OTHER INSTRUMENTATION↗

FEM models and Fourier decomposition of three thick septa

Here, the CEBAF recirculating linear accelerator uses 26 septa: 8 thin, 17 thick and one Lamberston. We report here on detailed FEM models of one thick current-sheet septum, the Lambertson, and a new thick-septum concept which contains features of both. The last has higher-order field components within a factor of two of the current-sheet septum and much lower current density in the conductor were it used as a 'drop-in' replacement in CEBAF. There are accelerator layouts in which the new concept is superior to the current sheet septum in both harmonic content and current density.

47 OTHER INSTRUMENTATION↗