Optical Design of Multi-field Integral Field Unit Spectrograph for the ORCAS Keck Instrument Development II (ORKID II) Instrument

We have designed an Integral Field Unit Spectrometer for the ORCAS Keck Instrument Development II (ORKID II) Instrument. Building on the success of the ORKID instrument (which achieved 15.1 masec FWHM visible spectrum imaging), ORKID II will add Integral Field Spectroscopy to analyze Active Galactic Nuclei (AGN), Supernovae redshift and brightness, and other science observations. Several design options have been explored based on image slicers manufactured by the Canon Corporation’s machining process. Field layouts can include up to three disparate spatial sampling, with a lower limit of 6.7 masec. Spectral resolutions are considered from R 100 to R 10,000. The modular design of the concept allows for configuring the instrument for various observing campaigns.

Instrumentation and Photography↗

Optical Air Flow Measurements for Flight Tests and Flight Testing Optical Air Flow Meters

Optical air flow measurements can support the testing of aircraft and can be instrumental to in-flight investigations of the atmosphere or atmospheric phenomena. Furthermore, optical air flow meters potentially contribute as avionics systems to flight safety and as air data systems. The qualification of these instruments for the flight environment is where we encounter the systems in flight testing. An overview is presented of different optical air flow measurement techniques applied in flight and what can be achieved with the techniques for flight test purposes is reviewed. All in-flight optical airflow velocity measurements use light scattering. Light is scattered on both air molecules and aerosols entrained in the air. Basic principles of making optical measurements in flight, some basic optical concepts, electronic concepts, optoelectronic interfaces, and some atmospheric processes associated with natural aerosols are reviewed. Safety aspects in applying the technique are shortly addressed. The different applications of the technique are listed and some typical examples are presented. Recently NASA acquired new data on mountain rotors, mountain induced turbulence, with the ACLAIM system. Rotor position was identified using the lidar system and the potentially hazardous air flow profile was monitored by the ACLAIM system.

Jentink, Henk W.↗

The Canadian Galactic Emission Mapper: A New 8-10 GHz Telescope To Map the Polarization of the Northern Sky

The Canadian Galactic Emission Mapper (CGEM) radio telescope is mapping polarized Galactic foregrounds from 8-10 GHz to aid in the search for B-modes in the Cosmic Microwave Background (CMB). Here we describe the design and early on-sky characterization of the CGEM optics. CGEM employs an on-axis, hat feed optical design that is a body of revolution (BOR) and exhibits excellent intrinsic polarization purity. We describe how we have optimized the optics with a novel framework that can directly minimize simulated intensity to polarized intensity (T → P) leakage in angular power spectrum space. The optimized optics exhibit simulated T → P leakage that is orders of magnitude below anticipated CℓBB for r = 10 −3 when scaled from 8-10 GHz to the CMB observing window near 95 GHz. We go on to describe the mechanical design of the optics, including a novel secondary mirror support made from Astroquartz composite that has low loss, low dielectric constant, and preserves the BOR symmetry of the optics. We then showcase the early on-sky performance of the optics with observations of the Sun and satellites, which probe the beam to 40dB down from the peak. A beam model for the deployed CGEM optics based on electromagnetic simulations is in excellent agreement with the on-sky data.

cosmic microwave background↗

Analysis of Observed Contamination Through SAGE III's First Year on Orbit

SAGE III is a payload on the International Space Station that conducts measurements of ozone and other atmospheric constituents through the use of a moderate resolution spectrometer with an operating wavelength range of 290 nm to 1550 nm. Because of the optically sensitive nature of the payload, a suite of eight Thermoelectric Quartz Crystal Microbalances (TQCMs) were included to monitor the operating environment. During the rst year of operation, the SAGE III TQCMs were instrumental in detecting several periods of higher contamination and localizing their sources. A clear window made from quartz crystal covers the instrument assembly's aperture. Under nominal operating conditions, this window is only open during science gathering activities. However, if the rates of contamination accumulation are detected to be above the background rate, the window will be kept closed during science gathering to protect the optically sensitive instrument mirror. An analysis of the signal transmissions through the window for the wavelengths of 290 nm to 1550 nm has been conducted to determine any possible degradation of the window and potential in uence on science data collected to date, and established a baseline for future analysis.

Thompson, Michael P.↗

Laser-optical blade tip clearance measurement system

The need for blade tip clearance instrumentation has been intensified recently by advances in technology of gas turbine engines. A new laser-optical measurement system has been developed to measure single blade tip clearances and average blade tip clearances between a rotor and its gas path seal in rotating component rigs and complete engines. The system is applicable to fan, compressor and turbine blade tip clearance measurements. The engine mounted probe is particularly suitable for operation in the extreme turbine environment. The measurement system consists of an optical subsystem, an electronic subsystem and a computing and graphic terminal. Bench tests and environmental tests were conducted to confirm operation at temperatures, pressures, and vibration levels typically encountered in an operating gas turbine engine.

Barranger, J. P.↗

Testing of Large Diameter Fresnel Optics for Space Based Observations of Extensive Air Showers

The JEM-EUSO mission will detect extensive air showers produced by extreme energy cosmic rays. It operates from the ISS looking down on Earth's night time atmosphere to detect the nitrogen fluorescence and Cherenkov produce by the charged particles in the EAS. The JEM-EUSO science objectives require a large field of view, sensitivity to energies below 50 EeV, and must fit within available ISS resources. The JEM-EUSO optic module uses three large diameter, thin plastic lenses with Fresnel surfaces to meet the instrument requirements. A bread-board model of the optic has been manufactured and has undergone preliminary tests. We report the results of optical performance tests and evaluate the present capability to manufacture these optical elements.

Adams, James H.↗

Evaluation of Wing Load Calibration and Sensing Methods Using Conventional Strain Gages and a Fiber Optic Sensing System Installed on a Straight Tapered Wing

State-of-the-art instrumentation techniques have provided an opportunity to obtain greater insight into structural wing loads during flight. An investigation was undertaken to research new wing instrumentation and load sensing techniques for measuring accurate in-flight spanwise load distributions on wing structures. A straight tapered wing was instrumented with both conventional foil strain gages at five spanwise wing stations and fiber optic strain sensors at every half inch along the entire wing span. Thirty-nine unique load cases were applied to the wing lower surface using hydraulic actuators to obtain various shear, bending moment, and torque load distributions on the wing. This paper will highlight three load calibration approaches. Conventional linear regression calibration methods were applied to foil strain gages providing a single wing station vertical shear, bending moment, and torque load. Linear regression methods were applied to a fiber optic sensing system to provide bending moment and torque spanwise load distributions. A load sensing scheme using strain derived wing shape information derived from a single load case provided vertical shear and bending moment spanwise load distribution information. Aspects of the three different approaches will be compared and contrasted to inform the reader of the benefits or disadvantages of each. Instrument installation, sensor characteristics, test execution aspects, and recommended calibration techniques will be discussed.

structural mechanics↗

Digital system for dynamic turbine engine blade displacement measurements

An instrumentation concept for measuring blade tip displacements which employs optical probes and an array of micro-computers is presented. The system represents a hitherto unknown instrumentation capability for the acquisition and direct digitization of deflection data concurrently from all of the blade tips of an operational engine rotor undergoing flutter or forced vibration. System measurements are made using optical transducers which are fixed to the case. Measurements made in this way are the equivalent of those obtained by placing three surface-normal displacement transducers at three positions on each blade of an operational rotor.

Kiraly, L. J.↗

A Unique, Optically Accessible Flame Tube Facility for Lean Combustor Studies

A facility that allows interrogation of combusting flows by advanced diagnostic methods and instrumentation has been developed at the NASA Lewis Research Center. An optically accessible flame tube combustor is described which has high temperature, pressure, and air flow capabilities. The windows in the combustor measure 3.8 cm axially by 5.1 cm radially, providing 67% optical access to the 7.6 cm x 7.6 cm cross section flow chamber. Advanced gas analysis instrumentation is available through a gas chromatography/mass spectrometer system (GC/MS), which has on-line capability for heavy hydrocarbon measurement with resolution to the parts per billion level. The instrumentation allows one to study combusting flows and combustor subcomponents, such as fuel injectors and air swirlers. Planar Laser Induced Fluorescence (PLIF) can measure unstable combustion species, which cannot be obtained with traditional gas sampling. This type of data is especially useful to combustion modellers. The optical access allows measurements to have high spatial and temporal resolution. GC/MS data and PLIF images of OH- are presented from experiments using a lean direct injection (LDI) combustor burning Jet-A fuel at inlet temperatures ranging from 810 K to 866 K, combustor pressures up to 1380 kPa, and equivalence ratios from 0.41 to 0.59.

Hicks, Yolanda R.↗

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser↗

Two-Year Cosmology Large Angular Scale Surveyor (CLASS) Observations: 40GHz Telescope Pointing, Beam Profile, Window Function, and Polarization Performance

The Cosmology Large Angular Scale Surveyor (CLASS) is a telescope array that observes the cosmic microwave background (CMB) over 75% of the sky from the Atacama Desert, Chile, at frequency bands centered near 40, 90, 150, and 220 GHz. CLASS measures the large angular scale (1°~< θ >=90°) CMB polarization to constrain the tensor-to-scalar ratio at the r ∼ 0.01 level and the optical depth to last scattering to the sample variance limit. This paper presents the optical characterization of the 40 GHz telescope during its first observation era, from 2016 September to 2018 February. High signal-to-noise observations of the Moon establish the pointing and beam calibration. The telescope boresight pointing variation is <0°. 023 (<1.6% of the beam’s full width at half maximum (FWHM)). We estimate beam parameters per detector and in aggregate, as in the CMB survey maps. The aggregate beam has an FWHM of 1°.579 ± 0°.001 and a solid angle of 838 ± 6 μsr, consistent with physical optics simulations. The corresponding beam window function has a sub-percent error per multipole at ℓ < 200. An extended 90° beam map reveals no significant far sidelobes. The observed Moon polarization shows that the instrument polarization angles are consistent with the optical model and that the temperature-to-polarization leakage fraction is <10(exp −4) (95% C.L.). We find that the Moon-based results are consistent with measurements of M42, RCW 38, and Tau A from CLASS’s CMB survey data. In particular, Tau A measurements establish degree- level precision for instrument polarization angles.

Xu, Zhilei↗

WMAP Observatory Thermal Design and On-Orbit Thermal Performance

The Wilkinson Microwave Anisotropy Probe (WMAP) observatory, launched June 30, 2001, is designed to measure the cosmic microwave background radiation with unprecedented precision and accuracy while orbiting the second Lagrange point (L2). The instrument cold stage must be cooled passively to <95K, and systematic thermal variations in selected instrument components controlled to less than 0.5 mK (rms) per spin period. This paper describes the thermal design and testing of the WMAP spacecraft and instrument. Flight thermal data for key spacecraft and instrument components are presented from launch through the first year of mission operations. Effects of solar flux variation due to the Earth's elliptical orbit about the sun, surface thermo-optical property degradations, and solar flares on instrument thermal stability are discussed.

Glazer, Stuart D.↗

Design and performance of the cryogenic focal plane optics assembly for the Infrared Astronomical Satellite (IRAS)

The Infrared Astronomical Satellite (IRAS) has successfully completed its mission of providing an unbiased all-sky survey of astronomical objects in the 8 to 120 micrometer wavelength region. The design and performance of the Focal Plane Optics Assembly (FPOA) for the IRAS instrument is described in this paper. The FPOA consists of 62 survey field stops, 62 individual small field lenses, 124 small spectral filters, and a precision multi-part aluminum housing. The FPOA is capable of repeated thermal cycling from ambient temperature to 2 Kelvin. The spectral filters, along with the detector spectral responses, provide infrared bandpasses of 8-15, 18-30, 46-78, and 85-117 micrometers. The combination of very long wavelengths, liquid helium temperatures, and small size provided a significant design challenge. Spectral filter and field lens designs for the four spectral bands are described. Also, discussed are techniques which were developed for mechanical mounting of the small lenses and spectral filters, and to assure their optical alignment.

Bamberg, J. A.↗

Sample shape and boundary dependence of measured transverse thermal properties

In spite of increased interest in thermal Hall measurements for the analysis of insulating quantum materials, there remains large uncertainty in such measurements due to contact misalignment. In this paper, we propose that sample geometry and uncertain boundary conditions provide an additional source of uncertainty in the measurement of $D_{xy}$ or $κ_{xy}$. By running simple simulations in an open source finite-element solver, we demonstrate that measured $D_{xy}$ can be changed by a non-negligible fraction in samples with similar width and length. This geometric corrective factor depends on the distinction between a uniform heat flow and constant temperature boundary couplings to a bath. Sample geometry and boundary conditions can be accounted for through simulation or by using rectangular samples to make thermal Hall measurements more reliable and reproducible. Finally, we detail a contactless optical method for measuring $D_{xy}$ based on an existing photothermal microscope technique. This method is insensitive to the longitudinal diffusivity pollution caused by contact misalignment.

36 MATERIALS SCIENCE↗

GOES-R Dual Isolation

The Geostationary Operational Environmental Satellite-R Series (GOES-R) is the first of the next generation geostationary weather satellites, scheduled for delivery in late 2015. GOES-R represents a quantum increase in Earth and solar weather observation capabilities, with 4 times the resolution, 5 times the observation rate, and 3 times the number of spectral bands for Earth observations. With the improved resolution, comes the instrument suite's increased sensitive to disturbances over a broad spectrum 0-512 Hz. Sources of disturbance include reaction wheels, thruster firings for station keeping and momentum management, gimbal motion, and internal instrument disturbances. To minimize the impact of these disturbances, the baseline design includes an Earth Pointed Platform (EPP), a stiff optical bench to which the two nadir pointed instruments are collocated together with the Guidance Navigation & Control (GN&C) star trackers and Inertial Measurement Units (IMUs). The EPP is passively isolated from the spacecraft bus with Honeywell D-Strut isolators providing attenuation for frequencies above approximately 5 Hz in all six degrees-of-freedom. A change in Reaction Wheel Assembly (RWA) vendors occurred very late in the program. To reduce the risk of RWA disturbances impacting performance, a secondary passive isolation system manufactured by Moog CSA Engineering was incorporated under each of the six 160 Nms RWAs, tuned to provide attenuation at frequencies above approximately 50 Hz. Integrated wheel and isolator testing was performed on a Kistler table at NASA Goddard Space Flight Center. High fidelity simulations were conducted to evaluate jitter performance for four topologies: 1) hard mounted no isolation, 2) EPP isolation only, 2) RWA isolation only, and 4) dual isolation. Simulation results demonstrate excellent performance relative to the pointing stability requirements, with dual isolated Line of Sight (LOS) jitter less than 1 micron rad.

GN&C Engineering↗

Measurement of surface reactions in the space environment

The Atomic Oxygen Measurement Spacecraft, ATOMS, and a suite of associated instruments, designed to measure the performance of improved atomic-oxygen-resistant materials and coatings in orbit and to telemeter the resulting data and video images to earth at intervals during a one-year mission, have been described in a definition study sponsored by the Langley Research Center under NASA's In-Space Technology Experiments Program. The objective of the program is to work toward an improvement of base materials and surface coatings which will resist the serious degradation experienced by the external surfaces of LEO spacecraft as a result of the ablative effects of atmospheric oxygen, possibly catalyzed by solar UV radiation. This miniature orbiting laboratory includes a radio-frequency mass spectrometer, a set of osmium actinometers, and a scanning optical microscope. The design of these instruments and their use in the overall experiment are discussed.

Abdou, Wedad A.↗

Optical Detection of Blade Flutter

Dynamic strain gages mounted on rotor blades are used as the primary instrumentation for detecting the onset of flutter and defining the vibratory mode and frequency. Optical devices are evaluated for performing the same measurements as well as providing supplementary information on the vibratory characteristics. Two separate methods are studied: stroboscopic imagery of the blade tip and photoelectric scanning of blade tip motion. Both methods give visual data in real time as well as video tape records. The optical systems are described, and representative results are presented. The potential of this instrumentation in flutter research is discussed.

Nieberding, W. C.↗

Intensity Modulated Fiber Optic Sensor: A Novel Grid Measurement Unit

This paper presents a novel approach to physical displacement-based power grid measuring via an Intensity Modulated Fiber Optic Sensor (IMFOS). An IMFOS utilizes one fiber to transmit the intensity modulation light from its Electro-Optic controller to a fiber optic probe. The power grid voltage and current can induce physical displacements in transducers via the piezoelectric effect and the Lorentz law, respectively, which then result in a distance change between the optical probe and the reflective surface of the transducers. In parallel, multiple fibers are used to collect the reflective light for electro-optic conversion. Furthermore, a National Instruments-based characterization platform is set up for performance evaluation. Here, the testing result demonstrates that the IMFOS is immune to the inherent DC and low-frequency saturation issues prevalent in conventional potential and current transformers. Finally, the IMFOS is implemented in a Universal Grid Analyzer to illustrate its applicability for phasor estimation in actual power grids.

42 ENGINEERING↗