At least 1,621 records · Page 90

10 Boron-film-based gas detectors at ESS

The development of detectors for the European Spallation Source is an important parallel element to the effort put into the design and construction of the neutron source and instruments. The 10Boron-film-based detector developments that started over a decade ago as basic detector concepts have now reached technical maturity after intense prototyping work and numerous testing campaigns. Several of the ESS beamlines that will soon enter the commissioning phase started welcoming the detector systems built with the 10 B-film converter technology. The real-size demonstrators evolved in the last 2–3 years into a diverse suite of gas proportional counters for use in diffraction, reflectometry and small-angle scattering studies in spite of the operational complexity posed by the requirements for large-area coverage, low material budget and robustness for operation in the high-flux and high-radiation environment of ESS. The detectors are now being shipped to ESS or undergoing the last performance and calibration tests before being handed over to the instrument teams for installation in the host beamlines. A common feature of these detector systems is the very large number of readout channels that they are instrumented with in order to fulfill the demanding requirements for sensitivity, spatial resolution and count-rate capability. Across all of the detector types that will operate at ESS, the integration, testing and commissioning of the read-out technologies and software tools for data reduction, calibration and analysis are the focus of the detector and integration teams. These will yield a wealth of knowledge about their operation as well as initial results on the in-situ performance, a very important asset to ensure rapid commissioning of the detectors when neutrons from the ESS source become available. In this paper we will give an overview of the 10 B-film-based detector technologies included in the ESS detector suite that are currently facing the transition from the production phase to installation and integration with the other beamline components, which comes with its own specific challenges of both organizational and technical nature.

47 OTHER INSTRUMENTATION↗

Pulse Mode Calibration of the Micro Pocket Fission Detector

The Micro-Pocket Fission Detector (MPFD) is a neutron sensor currently under development in the High Temperature Test Laboratory (HTTL) for use as a supporting instrument during material testing experiments performed at TREAT. The detector has the capability to observe the real-time neutron population while surviving the harsh radiation, and temperature conditions, which sets it apart from most neutron sensitive devices. The next step in the instrument development process is to define a method of calibrating pulse-mode operations. This procedure will allow the detector to be calibrated to allow for absolute measurements of localized neutron population in real time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Neutron Component in Patients under High Energy Radiotherapy By Means of an On Line and In Vivo procedure

The use of improved radiotherapy methods has raised the concern about second cancer induction. Epidemiological studies have shown a major incidence of secondary cancer in radiotherapy patients compared to patients subjected to another type of treatment. In this regard, it is important to determine the peripheral dose received by the patient during the treatment. While photon doses have been deeply contemplated, neutron contamination in high energy photon beams is still a subject of research and discussion. In the present work, we introduce a new procedure based on a digital device that allows real time neutron contamination evaluation. Several irradiations of an anthropomorphic phantom have been carried out in a variety of facilities and treatments. The purpose was to correlate the measurements from the digital detector with the neutron doses obtained in the phantom by Monte Carlo simulations and experimental measurements. A model has been designed to calculate the organ equivalent dose and risk estimates during any therapeutic session. The procedure has been used to monitor more than 1000 patients showing its applicability in clinical routine. It can be used both for inductive and retrospective studies with a reasonable uncertainty. Thus, this could provide the necessary information to complement the dosimetry of patient and estimate the treatment risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transport phenomena in intrinsic semiconductors and insulators at high current densities: Suppression of the broken neutrality drift

It is shown that, in addition to the diffusion and broken neutrality drift (BND) modes well-known for insulators and very lightly doped semiconductors, the quasineutral drift (QND) mode is possible. The transition from the BND to QND mode is accompanied by the appearance of a portion with a very sharp current rise in the current-voltage characteristic. This effect is observed in a new type of semiconductor detectors (CIDs, Current Injected Detectors) of high-intensity neutron and proton radiation, suggested, in particular, for Large Hadron Collider. The effect is unambiguously attributed now to the presence of radiation-induced deep centers in a semiconductor. It is shown, however, in this paper that the effect of a very sharp rise in current upon a slight increase in voltage is even possible when there are no deep centers. An equation adequately describing the possible transport modes in intrinsic semiconductors and insulators is derived. The results of an analytical study are confirmed by an adequate simulation.

36 MATERIALS SCIENCE↗

RICH (Robotic Interface Control & Handling) System for VULCAN

High flux neutron beam and high efficiency detectors warrant quick turn arounds of neutron diffraction measurements at the engineering materials diffractometer VULCAN. Efficient change and alignment of samples and automatic measurements at VULCAN are desired for better use of neutron beam time by users. In this work, we aim to develop a proof-of-concept Robotic Interactive Control & Handling System (RICH) for sample handling at VULCAN that could assist high throughput experiments and reduce the overhead time significantly. This was realized by a six-axis desktop robot with trained AI models. The trained AI models can recognize and locate samples in various types of positions in a live video stream. In addition, we developed smart algorithms which used our models on multiple cameras to recognize where samples are with respect to multiple point of views, and then using user-inputted parameters, align them to perform complex measurements.

42 ENGINEERING↗

Future of the MUSiC Experiment Data

The Measurements of Uranium Subcritical and Critical (MUSiC) experiment was a highly enriched uranium (HEU) experiment performed at the National Criticality Experiments Research Center (NCERC) executed between December 2020 and April 2021. The experiment intended to measure criticality and reactor kinetics parameters in a bare HEU system. The experiment concurrently measured radiation signatures from the system while utilizing different neutron source types. This was an attempt to benchmark both detectors and analysis techniques against one another for identical measurements. The experiment consisted of the Rocky Flats HEU hemi-shells constructed into ten configurations spanning between deeply subcritical (about 14 kgs) to supercritical (about 60 kgs). Two of the ten configurations were supercritical and the other eight were subcritical. The two supercritical configurations, often referred to as the critical configurations, were documented into an International Criticality Safety Benchmark Evaluation Project (ICSBEP) benchmark evaluation and submitted to the technical review group (TRG). The subcritical configurations of the MUSiC experiment were examined using three different detection systems. The systems include: the NoMAD He-3 neutron detector which consists of 15 He-3 tubes surrounded by a polyethylene matrix, a liquid scintillator system called the Rossi-α Measurement Rapid Organic Discriminating Detector (RAM-RODD), and a trans-stilbene organic scintillator array (OSCAR) provided by the University of Michigan. The NoMAD and RAM-RODD data are planned to be evaluated in two separate ICSBEP evaluations utilizing neutron noise methods such as Feynman Variance-to-Mean, Rossi-α and the pulsed neutron source method. Each of the subcritical configurations were examined using three different source types including: a Cf-252 source in the center, with only the intrinsic neutron source in the HEU, and with an external D-T neutron generator.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The effect of deadtime and electronic transients on the predelay bias in neutron coincidence counting

In neutron coincidence counting using the shift register autocorrelation technique, a predelay is inserted before the opening of the (R+A)-gate. Operationally the purpose of the predelay is to ensure that the (R+A)- and A-gates have matched effectiveness, otherwise a bias will result when the difference between the gates is used to calculate the accidentals corrected net reals coincidence rate. The necessity for the predelay was established experimentally in the early practical development and deployment of the coincidence counting method. The choice of predelay for a given detection system is usually made experimentally, but even today long standing traditional values (e.g., 4.5 µs) are often used. This, at least in part, reflects the fact that a deep understanding of why a finite predelay setting is needed and how to control the underlying influences has not been fully worked out. We attempt, in this paper, to gain some insight into the problem. One aspect we consider is the slowing down, thermalization, and diffusion of neutrons in the detector moderator. The other is the influence of deadtime and electronic transients. These may be classified as non-ideal detector behaviors because they are not included in the conventional model used to interpret measurement data. From improved understanding of the effect of deadtime and electronic transients on the predelay bias in neutron coincidence counting, the performance of both future and current coincidence counters may be improved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TREAT HODOSCOPE – A Predictive Simulation Model

The Transient Reactor Test Facility (TREAT) reactor is being restarted after over two decades of standby operation. TREAT is designed to test the time-dependent behavior of nuclear fuel during simulated reactor accidents. One of the principle data collection systems of TREAT is the fast neutron hodoscope which is used to observe the motion of the fuel test specimen as it is being damaged, deformed, or melted over the course of the power transient. The hodoscope is a grid of ex-core collimator channels paired with a bank of fast neutron sensitive radiation detectors. These detectors have historically been calibrated using empirical methods utilizing measurement data from smaller power pulses. Given modern computational capabilities this work sets out to establish a predictive computational capability of the fast neutron flux field exiting the hodoscope to support these calibrations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Application of the backward extrapolation method to pulsed neutron sources

We report particle detectors operated in pulse mode are subjected to the dead-time effect. When the average of the detector counts is constant over time, correcting for the dead-time effect is simple and can be accomplished by analytical formulas. However, when the average of the detector counts changes over time it is more difficult to take into account the dead-time effect. When a subcritical nuclear assembly is driven by a pulsed neutron source, simple analytical formulas cannot be applied to the measured detector counts to correct for the dead-time effect because of the sharp change of the detector counts over time. This work addresses this issue by using the backward extrapolation method. The latter can be applied not only to a continuous (e.g. californium) external neutron source but also to a pulsed external neutron source (e.g. by a particle accelerator) driving a subcritical nuclear assembly. Finally, the backward extrapolation method allows to obtain from the measured detector counts both the dead-time value and the real detector counts.

43 PARTICLE ACCELERATORS↗

Fabrication of Black Body Grids by Thick Film Printing for Quantitative Neutron Imaging

Neutron imaging offers deep penetration through many high-Z materials while also having high sensitivity to certain low-Z isotopes such as 1H, 6Li, and 10B. This unique combination of properties has made neutron imaging an attractive tool for a wide range of material science and engineering applications. However, measurements made by neutron imaging or tomography are generally qualitative in nature due to the inability of detectors to discriminate between neutrons which have been transmitted through the sample and neutrons which are scattered by the sample or within the detector. Recent works have demonstrated that deploying a grid of small black bodies (BBs) in front of the sample can allow for the scattered neutrons to be measured at the BB locations and subsequently subtracted from the total measured intensity to yield a quantitative transmission measurement. While this method can be very effective, factors such as the scale and composition of the sample, the beam divergence, and the resolution and construction of the detector may require optimization of the grid design to remove all measurement biases within a given experimental setup. Therefore, it is desirable to have a method by which BB grids may be rapidly and inexpensively produced such that they can easily be tailored to specific applications. In this work, we present a method for fabricating BB patterns by thick film printing of Gd2O3 and evaluate the performance with variation in feature size and number of print layers with cold and thermal neutrons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Experimental Validation of the Methodology for Partial Defect Verification of the Pressurized Water Reactor Spent Fuel Assemblies

A set of controlled experiments and Monte Carlo simulation studies with actual commercial pressurized water reactor (PWR) spent fuel assemblies were performed in order to validate an earlier proposal for partial defect testing of the PWR spent fuel assemblies. The proposed methodology involved insertion of tiny neutron and gamma detectors into the guide tubes of PWR assemblies, measurements and data evaluation. One of the key features of the data evaluation method was the concept of the base signature obtained by normalizing the ratio of gamma to neutron signals at each measurement position. As the base signature is relatively invariant to the characteristic variations of spent fuel assemblies such as initial fuel enrichment, cooling time, and burn-up, the methodology could be a powerful verification method which does not require operator declared information on the spent fuel. The benchmarking experiments indeed demonstrated that the methodology can be used for partial defect verification of the PWR spent fuel assemblies without operator declared data. The results from the experiments were compared with the simulations and the agreement between the two was well within ten percent. Thus, based on the simulation studies and benchmarking measurements, the methodology developed promises to be a powerful and practical way to detect partial defects that constitute 10% or more of the total active fuel pins. This far exceeds the detection threshold of 50% missing pins from a spent fuel assembly, a threshold defined by the IAEA Safeguards Criteria.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Statistical neutron capture in the limit of low nuclear level density

A major barrier in the study of neutron-induced nuclear reactions is the impossibility of direct measurements with short-lived radioactive isotopes. For these exotic nuclei, theoretical inputs such as the Photon Strength Function (PSF) are poorly constrained. At Los Alamos National Laboratory, the Detector for Advanced Neutron Capture Experiments (DANCE) provides direct measurements of γ-ray cascades following neutron capture reactions on stable or long-lived radioactive nuclei. While Hauser-Feshbach calculations can provide reasonable predictions for neutron capture on heavy nuclei, their application to neutron-rich light nuclei with low nuclear level densities and low neutron separation energies is questionable. In this paper, we report on the γ-ray spectra from individual neutron resonances from the 96 Zr(n, γ) reaction, with an emphasis on the sensitivity of of the γ-ray spectra to different PSF models. The comparison of the measured γ-ray spectra with predicted spectra does not support the addition of a low-energy enhancement of the size reported in many charged-particle reaction measurements, but the sensitivity of the γ-ray spectra to different PSF models is weak.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling filters for formation of mono-energetic neutron beams in the research reactor IRT MEPhI and optimization of radiation shielding for liquid-xenon detector

The paper considers formation of mono-energetic neutron beams at the entrance of experimental channels in research reactors for various applications. The problem includes the following steps: 1. Full-scale mathematical model of the research IRT MEPhI was developed for numerical evaluations of neutron spectra and neutron spatial distribution in the area of experimental channels. 2. Modeling of filters in the channel to shift neutron spectrum towards the required mono-energetic line was performed. 3. Some characteristics of neutron beams at the entrance of detector were evaluated. The filter materials were selected. The calculations were carried out with application of the computer code based on the high-precision Monte-Carlo code MCNP. As a result, mathematical model was created for the filter which is able to form mono-energetic (24 keV) neutron beam. The study was carried out within the frames of the research project on development of Russian emission detector with liquid noble gas to observe rare processes of neutrino scattering and particles of hypothetical dark matter in atomic nuclei. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of MCNPX-PoliMi Fission Models

We present new results on the measurement of correlated, outgoing neutrons from spontaneous fission events in a Cf-252 source. 16 EJ-309 liquid scintillation detectors are used to measure neutron-neutron correlations for various detector angles. Anisotropy in neutron emission is observed. The results are compared to MCNPX-PoliMi simulations and good agreement is observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of Neutron Uncertainty Types

The assessment of neutron data requires understanding the uncertainty. The uncertainty of the final quantities of interest, neutron multiplication and mass, is a combination of many other uncertainties because it is a combination of many other variables. The equations for the values of neutron multiplication and mass are quite complex. The relations between the many contributing variables and their uncertainties are complicated leading to complications in combining them. Additionally, some are statistical in nature, while others are systematic. In an effort to better understand and quantify the total uncertainty in neutron multiplication and SNM mass, they have been subdivided into four categories: setup, detector response, nuclear data, and object characterization. This paper discusses the four categories and what types of uncertainties are in each of them. This effort attempts to generalize this process for any neutron detector, but many of our examples show the Next Generation Multiplicity Detector (MC-15).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Possible application of scintillation detectors with semiconductor PMT for cosmic-neutron and gamma-ray detection

Solar system planets exploration and cosmic neutrons and gamma-ray flux research have been dynamically evolving for several decades. Different scintillation crystals are used for this purpose along with photo signal receivers, such as vacuum photomultiplier tubes (PMT). Many studies are being performed in order to provide alternative devices for photon signal capture: PIN-diodes,avalanche photodiodes, semiconductor silicon photomultipliers. We study the applicability of a silicon PMT in employing highresolution crystals in space applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NeutronSTARS Detector Modeling Report

Directly measuring (n,2n) cross sections on short-lived actinides presents a number of experimental challenges: scattered beam can produce a neutron background in the detectors, fission produces a substantial neutron background, and making a target from a short-lived isotope can be extremely difficult. The surrogate reaction technique is an experimental method for measuring cross sections on short-lived isotopes, and it provides a unique solution for measuring (n,2n) cross sections which addresses all three of these concerns. This technique involves measuring a charged-particle reaction cross section, where the reaction populates the same compound nucleus as the reaction of interest.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗