Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

SU-E-T-249: Neutron Model Upgrade for Radiotherapy Patients Monitoring Using a New Online Detector

Purpose: The purpose of this work is to improve the existing methodology to estimate neutron equivalent dose in organs during radiotherapy treatments, based on a Static Random Access Memory neutron detector (SRAMnd) [1]. This is possible thanks to the introduction of a new digital detector with improved characteristics, which is able to measure online the neutron fluence rate in the presence of an intense photon background [2]. Its reduced size, allows the direct estimation of doses in specific points inside an anthropomorphic phantom (NORMA) without using passive detectors as TLD or CR-39. This versatility will allow not only to improve the existing models (generic abdomen and H and N [1]) but to generate more specific ones for any technique. Methods: The new Thermal Neutron Rate Detector (TNRD), based on a diode device sensitized to thermal neutrons, have been inserted in 16 points of the phantom. These points are distributed to infer doses to specific organs. Simultaneous measurements of these devices and a reference one, located in front of the gantry, have been performed for the mentioned generic treatments, in order to improve the existing model. Results: These new devices have shown more precise since they agree better with Monte Carlo simulations. The comparison of the thermal neutron fluence, measured with TNRD, and the existing models, converted from events to fluence, shows an average improvement of (3.90±3.37) % for H and N and (12.61±9.43) % for abdomen, normalized to the maximum value. Conclusion: This work indicates the potential of these new devices for more precise neutron equivalent dose estimation in organs, as a consequence of radiotherapy treatments. The simplicity of the process makes possible to establish more specific models that will provide a better dose estimation. References[1] Phys Med Biol 2012; 57:6167–6191.[2] A new active thermal neutron detector. Radiat. Prot. Dosim. (in press)

60 APPLIED LIFE SCIENCES↗

Commissioning optically stimulated luminescence in vivo dosimeters for fast neutron therapy

Purpose: Clinical in vivo dosimeters intended for use with photon and electron therapies have not been utilized for fast neutron therapy because they are highly susceptible to neutron damage. The objective of this work was to determine if a commercial optically stimulated luminescence (OSL) in vivo dosimetry system could be adapted for use in fast neutron therapy. Methods: A 50.5 MeV fast neutron beam generated by a clinical neutron therapy cyclotron was used to irradiate carbon doped aluminum oxide (Al{sub 2}O{sub 3}:C) optically simulated luminescence dosimeters (OSLDs) in a solid water phantom under standard calibration conditions, 150 cm SAD, 1.7 cm depth, and 10.3 × 10.0 cm field size. OSLD fading and electron trap depletion studies were performed with the OSLDs irradiated with 20 and 50 cGy and monitored over a 24-h period to determine the optimal time for reading the dosimeters during calibration. Four OSLDs per group were calibrated over a clinical dose range of 0–150 cGy. Results: OSLD measurement uncertainties were lowered to within ±2%–3% of the expected dose by minimizing the effect of transient fading that occurs with neutron irradiation and maintaining individual calibration factors for each dosimeter. Dose dependent luminescence fading extended beyond the manufacturer’s recommended 10 min period for irradiation with photon or electron beams. To minimize OSL variances caused by inconsistent fading among dosimeters, the observed optimal time for reading the OSLDs postirradiation was between 30 and 90 min. No field size, wedge factor, or gantry angle dependencies were observed in the OSLDs irradiated by the studied fast neutron beam. Conclusions: Measurements demonstrated that uncertainties less than ±3% were attainable in OSLDs irradiated with fast neutrons under clinical conditions. Accuracy and precision comparable to clinical OSL measurements observed with photons can be achieved by maintaining individual OSLD calibration factors and minimizing transient fading effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Program of Fundamental-Interaction Research for the Ultracold-Neutron Source at the the WWR-M Reactor

The use of ultracold neutrons opens unique possibilities for studying fundamental interactions in particles physics. Searches for the neutron electric dipole moment are aimed at testing models of CP violation. A precise measurement of the neutron lifetime is of paramount importance for cosmology and astrophysics. Considerable advances in these realms can be made with the aid of a new ultracold-neutron (UCN) supersource presently under construction at Petersburg Nuclear Physics Institute. With this source, it would be possible to obtain an UCN density approximately 100 times as high as that at currently the best UCN source at the high-flux reactor of the Institute Laue–Langevin (ILL, Grenoble, France). To date, the design and basic elements of the source have been prepared, tests of a full-scale source model have been performed, and the research program has been developed. It is planned to improve accuracy in measuring the neutron electric dipole moment by one order of magnitude to a level of 10{sup −27} to 10{sup −28}e cm. This is of crucial importance for particle physics. The accuracy in measuring the neutron lifetime can also be improved by one order of magnitude. Finally, experiments that would seek neutron–antineutron oscillations by employing ultracold neutrons will become possible upon reaching an UCN density of 10{sup 3} to 10{sup 4} cm{sup −3}. The current status of the source and the proposed research program are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatial corrections for pulsed-neutron reactivity measurements.

For pulsed-neutron experiments performed in a subcritical reactor, the reactivity obtained from the area-ratio method is sensitive to detector positions. The spatial effects are induced by the presence of both the prompt neutron harmonics and the delayed neutron harmonics in the reactor. The traditional kinetics distortion factor is only limited to correcting the spatial effects caused by the fundamental prompt-{alpha} mode. In this paper, we derive spatial correction factors fp and fd to account for spatial effects induced by the prompt neutron harmonics and the delayed neutron harmonics, respectively. Our numerical simulations with the FX2-TH time-dependent multigroup diffusion code indicate that the high-order prompt neutron harmonics lead to significant spatial effects and cannot be neglected in calculating the spatial correction factors. The prompt spatial correction factor fp can be simply determined by the ratio of the normalized detector responses corresponding to the fundamental k-mode and the prompt neutron flux integrated over the pulse period. Thus, it is convenient to calculate and provides physically intuitive explanations on the spatial dependence of reactivity measured in the MUSE-4 experiments: overestimation of the subcriticality in regions close to the external neutron source and underestimation of the subcriticality away from the source but within the fuel region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Survey of Students from the National School on Neutron and X-ray Scattering: Communication Habits and Preferences

Oak Ridge National Laboratory (ORNL) offers the scientific community unique access to two types of world-class neutron sources at a single site - the Spallation Neutron Source (SNS) and the High Flux Isotope Reactor (HFIR). The 85-MW HFIR provides one of the highest steady-state neutron fluxes of any research reactor in the world. And the SNS is one of the world's most intense pulse neutron beams. Management of these resources is the responsibility of the Neutron Sciences Directorate (NScD). NScD started conducting the National School on Neutron and X-ray Scattering (NXS) in conjunction with the Advanced Photon Source (APS) at Argonne National Laboratory in 2007. This survey was conducted to determine the most effective ways to reach students with information about what SNS and HFIR offer the scientific community, including content and communication vehicles. The emphasis is on gaining insights into compelling messages and the most effective channels, e.g., Web sites and social media, for communicating with students about neutron science The survey was conducted in two phases using a classic qualitative investigation to confirm language and content followed by a survey designed to quantify issues, assumptions, and working hypotheses. Phase I consisted of a focus group in late June 2010 with students attending NXS. The primary intent of the group was to inform development of an online survey. Phase two consisted of an online survey that was developed and pre-tested in July 2010 and launched on August 9, 2010 and remained in the field until September 9, 2010. The survey achieved an overall response rate of 48% for a total of 157 completions. The objective of this study is to determine the most effective ways to reach students with information about what SNS and HFIR offer the scientific community, including content and communication vehicles. The emphasis is on gaining insights into compelling messages and the most effective channels, e.g., Web sites, social media, for communicating with students about neutron science.

43 PARTICLE ACCELERATORS↗

Fast Neutron Shielding [Slides]

• In Neutron shielding, neutron energy is the primary determinant of shield characteristics. • Fast Neutrons (E ≥1 MeV) must first me thermalized with high neutron scattering materials. • These thermal neutrons can then be absorbed or shielded with high cross sections for neutron absorption. • Rain-gauges, which utilize principles of nucleic detection, operate with thermal neutron detectors. • Systems such as He-3 detectors measure rain by correlating neutron moderation with rain level. • From this relationship its possible to determine unknown levels of substance with a known detector signal strength.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimizing Laser-accelerated Ion Beams for a Collimated Neutron Source

High-flux neutrons for imaging and materials analysis applications have typically been provided by accelerator- and reactor-based neutron sources. A novel approach is to use ultraintense (>1018W/cm2) lasers to generate picosecond, collimated neutrons from a dual target configuration. In this article, the production capabilities of present and upcoming laser facilities are estimated while independently maximizing neutron yields and minimizing beam divergence. A Monte-Carlo code calculates angular and energy distributions of neutrons generated by D-D fusion events occurring within a deuterated target for a given incident beam of D+ ions. Tailoring of the incident distribution via laser parameters and microlens focusing modifies the emerging neutrons. Projected neutron yields and distributions are compared to conventional sources, yielding comparable on-target fluxes per discharge, shorter time resolution, larger neutron energies and greater collimation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

THE INTERMEDIATE NEUTRON-CAPTURE PROCESS AND CARBON-ENHANCED METAL-POOR STARS

Carbon-enhanced metal-poor (CEMP) stars in the Galactic Halo display enrichments in heavy elements associated with either the s (slow) or the r (rapid) neutron-capture process (e.g., barium and europium, respectively), and in some cases they display evidence of both. The abundance patterns of these CEMP- s / r stars, which show both Ba and Eu enrichment, are particularly puzzling, since the s and the r processes require neutron densities that are more than ten orders of magnitude apart and, hence, are thought to occur in very different stellar sites with very different physical conditions. We investigate whether the abundance patterns of CEMP- s / r stars can arise from the nucleosynthesis of the intermediate neutron-capture process (the i process), which is characterized by neutron densities between those of the s and the r processes. Using nuclear network calculations, we study neutron capture nucleosynthesis at different constant neutron densities n ranging from 10{sup 7}–10{sup 15} cm{sup -3}. With respect to the classical s process resulting from neutron densities on the lowest side of this range, neutron densities on the highest side result in abundance patterns, which show an increased production of heavy s -process and r -process elements, but similar abundances of the light s -process elements. Such high values of n may occur in the thermal pulses of asymptotic giant branch stars due to proton ingestion episodes. Comparison to the surface abundances of 20 CEMP- s / r stars shows that our modeled i -process abundances successfully reproduce observed abundance patterns, which could not be previously explained by s -process nucleosynthesis. Because the i -process models fit the abundances of CEMP- s / r stars so well, we propose that this class should be renamed as CEMP- i .

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of an RPM based on Gd-lined plastic scintillator for neutron and gamma detection [ANIMMA--2015-IO-372]

A Radiation Portal Monitor (RPM) was developed by the Istituto Nazionale di Fisica Nucleare (INFN) and Ansaldo Nucleare (ANN) within the FP7 SCINTILLA European project. The system was designed to detect both gamma and neutron radiation with a single technology. It is conceived to monitor vehicle and cargo containers in transits across borders or ports, to find radioactive elements and to avoid illegal trafficking of strategic nuclear materials. The system is based on a {sup 3}He-free neutron detection technology using plastic scintillators coupled to Gadolinium to detect and discriminate gamma from neutron signals. During the 3 years of the SCINTILLA project the construction and test of the first two prototypes drove the definition of the final layout of a full RPM system consisting of two twin pillars as a portal for vehicle and cargo container scan. A custom System Control Software (SCS) manages the electronics of the RPM, the ancillary devices and the data analysis. The combination of the detector layout and of the software functionalities enables both to distinguish neutrons and gammas and to identify the energy range of a detected gamma source. The system was initially characterized via static tests with gamma and neutron sources in the INFN laboratory. These measurements were used to calibrate the detector, evaluate the response of the single pillars as well as of the full system, and optimize the RPM configuration and discrimination algorithm. During this phase, specific tests were performed to study the stability over time of the system, monitoring the measured the neutron and gamma count rates over periods of several weeks. The results allow us to demonstrate the reliability and robustness of the RPM. In a second time the RPM performance was studied via dynamic tests performed during the SCINTILLA test and benchmark campaigns. These measurements took place in the JRC ITRAP+10 facility at Ispra (Varese-Italy). The laboratory is equipped with an experimental set-up for dynamic tests of multiple systems according to international standards. The performed measurements utilized radioactive sources with activities selected according to ANSI and IEC standards to test the detector alarm performances in terms of gamma and neutron response, sensitivity to high gamma fields, sensitivity to moderated neutron sources as well as false alarm rates (FAR). In addition, the RPM was tested in challenging configurations exceeding the requirements set by international standards to determine the real limits of the system. The results obtained during these campaigns demonstrated that the system detection efficiency is not only compliant to international standards for its category, but often exceeds them, demonstrating the validity of the chosen technology and of the implemented layout. The positive performance also showed the effectiveness of the SCS and of its functionalities. To further demonstrate the system capabilities, a test in a real-life environment of the RPM is planned to happen in a near future by installing the detectors in a seaport. In this presentation I will give an overview of the RPM characteristics, of its performances as determined in the test campaign mentioned above and of future plans, to demonstrate how this technology can be an effective choice for the realization of {sup 3}He-free RPM detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose Mapping from a DD Neutron Generator at the University of Sharjah

The University of Sharjah recently acquired a model DD109.4M neutron generator from Adelphi Technology. The generator is moderated and has three neutron ports which are capable of providing fast and thermal neutrons. This neutron generator is intended to be used for various studies like neutron activation analysis, neutron imaging, and profiling and irradiation effects. It is imperative that appropriate measures are taken in order to minimize the radiation dose to the operators, students, and the public. The resulting dose must not exceed the limits set by the UAE Federal Authority for Nuclear Regulations (FANR) and the International Atomic Energy Agency (IAEA). The objective of this study is to generate a neutron and photon dose map of the generator room and its surrounding using simulations, experimentally verify this dose mapping, and set the operating and safety procedures for the neutron generator. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Benchmarking of the MCNPX predictions of the neutron time-emission spectra at LANSCE - 25332

We currently operate Mark-III generation of the spallation neutron target-moderator-reflector-shield (TMRS) assembly at the Manuel Lujan Jr. Neutron Scattering Center of the Los Alamos Neutron Science Center (LANSCE). Mark-III is scheduled for replacement with the next-generation TMRS Mark-IV in 2020. Mark-IV enhances the neutronic performance in the eV-MeV energy range by increasing intensity and improving energy resolution. The increased eV-MeV neutron flux, together with the elevated gamma-ray background, has implications for the radiation shielding of the neutron flight paths and scientific instruments. To update the shielding design, we need to maintain a thoroughly benchmarked MCNPX model of the entire TMRS assembly. In this article we use our detailed MCNPX model of Mark-III to calculate the neutron time-emission spectra. With these spectra we generate the resolution function for SAMMY calculations of capture cross section in {sup 197}Au in the resonance region between 70 eV and 1 keV. We compare the calculated data with the experimental data measured with the DANCE instrument using the neutron time-of-flight technique. We show that our current model predicts measurements accurately and thus provides a solid base for developing the radiation shielding design of the new TMRS assembly. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Contribution To Degradation Study, Behavior Of Unsaturated Polyester Resin Under Neutron Irradiation

Applications of unsaturated polyester thermosetting resins are numerous in construction sector, in transport, electric spare parts manufactures, consumer goods, and anticorrosive materials. This survey reports the effect of thermosetting polymer degradation (unsaturated polyester): degradation by neutrons irradiation. In order to evaluate the deterioration of our material, some comparative characterizations have been done between standard samples and damaged ones. Scanning electron microscopy (SEM), ultrasonic scanning, hardness test (Shore D) are the techniques which have been used. The exposure to a neutrons flux is carried out in the column of the nuclear research reactor of Draria (Algiers-Algeria). The energetic profile of the incidental fluxes is constituted of fast neutrons (PHI{sub R} = 3.10{sup 12} n.cm{sup -2}.s{sup -1}, E = 2 Mev) of thermal neutrons (PHI{sub TH} = 10{sup 13} n.cm{sup -2}.s{sup -1}; E = 0.025 ev) and epithermal neutrons (PHI{sub epi} = 7.10{sup 11} n.cm{sup -2}.s{sup -1}; E>4,9 ev). The received dose flow is 0,4 Kgy. We notice only a few scientific investigations can be found in this field. In comparison with the standard sample (no exposed) it is shown that the damage degree is an increasing process with the exposure. Concerning the description of irradiation effects on polymers, we can advance that several reactions are in competition: reticulation, chain break, and oxidation by radical mechanism. In our case the incidental particle of high energy fast neutrons whose energy is greater or equal to 2 Mev, is braked by the target with a nuclear shock during which the incidental particle transmits a part of its energy to an atom. If the energy transfer is sufficient, the nuclear shock permits to drive out an atom of its site the latter will return positioning interstitially, the energy that we used oversteps probably the energy threshold (displacement energy). This fast neutrons collision with target cores proceeds to an indirect ionization by the preliminary creation of excited secondary species that will generate ionization. Scanning electron microscopy (SEM) performed with an acceleration tension of 0,7 kV shows clearly the caused damage. This observation seems to indicate the presence of major chain breaks for the sample bombarded during 90 minutes. Let us note that the presence of benzenic cores improves behavior toward radiations indeed the chemical function recognized as the most stable to radiations is the aromatic ring. In order to value the rigidity of our material we have determined the Young's modulus . The values are 7.17, 7.60, 8.39 and 8.96 Gpa respectively for blank samples, 30, 60 and 90 minutes exposure ones. Thus, we remark an increase of Young's modulus that can be interpreted in terms of reticulation, provided to use the level of irradiation dose.

36 MATERIALS SCIENCE↗

New measurement system for on line in core high-energy neutron flux monitoring in materials testing reactor conditions

Flux monitoring is of great interest for experimental studies in material testing reactors. Nowadays, only the thermal neutron flux can be monitored on line, e.g., using fission chambers or self-powered neutron detectors. In the framework of the Joint Instrumentation Laboratory between SCK-CEN and CEA, we have developed a fast neutron detector system (FNDS) capable of measuring on line the local high-energy neutron flux in fission reactor core and reflector locations. FNDS is based on fission chambers measurements in Campbelling mode. The system consists of two detectors, one detector being mainly sensitive to fast neutrons and the other one to thermal neutrons. On line data processing uses the CEA depletion code DARWIN in order to disentangle fast and thermal neutrons components, taking into account the isotopic evolution of the fissile deposit. The first results of FNDS experimental test in the BR2 reactor are presented in this paper. Several fission chambers have been irradiated up to a fluence of about 7 x 10{sup 20} n/cm{sup 2}. A good agreement (less than 10% discrepancy) was observed between FNDS fast flux estimation and reference flux measurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Focusing adaptive-optics for neutron spectroscopy at extreme conditions

Neutron Spectroscopy employing extreme-conditions sample environments is nowadays a crucial tool for the understanding of fundamental scientific questions as well as for the investigation of materials and chemical-physical properties. For all these kinds of studies, an increased neutron flux over a small sample area is needed. The prototype of a focusing neutron guide component, developed and produced completely at the neutron source FRM II in Garching (Germany), has been installed at the time-of-flight (TOF) disc-chopper neutron spectrometer TOFTOF and came into routine-operation. The design is based on the compressed Archimedes' mirror concept for finite-size divergent sources. It represents a unique device combining the supermirror technology with Adaptive Optics, suitable for broad-bandwidth thermal-cold TOF neutron spectroscopy (here optimized for 1.4–10 Å). It is able to squeeze the beam cross section down to a square centimeter, with a more than doubled signal-to-background ratio, increased efficiency at high scattering angles, and improved symmetry of the elastic resolution function. We present a comparison between the simulated and measured beam cross sections, as well as the performance of the instrument within real experiments. This work intends to show the unprecedented opportunities achievable at already existing instruments, along with useful guidelines for the design and construction of next-generation neutron spectrometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Neutron-Radiation Tolerance of Lithium Indium Diselenide Semiconductors

Herein we discuss lithium indium diselenide (LISe) as a semiconductor that holds promise for neutron imaging sensor technologies because of its high neutron absorption efficiency and its corresponding ability to discriminate between gamma rays and neutrons. However, being a semiconductor, LISe may not be sufficiently radiation hard for practical application in radiation hard environments. Therefore, a systematic evaluation of the changes in material and electronic properties of LISe after high neutron fluence exposures is investigated. Herein, the characterization methods are utilized which included UV–vis, X-ray diffraction, radioluminescence, Raman, fourier transform infrared spectroscopy (FTIR), current–voltage, and neutron sensing. Characteristics of LISe material that appeared in the literature are identified herein along with several that are expected to appear based on theoretical analyses. The results obtained show clear changes in the material properties of LISe after neutron exposure up to a fluence of 10 16 n cm -2 . However, LISe is still able to sense neutrons above the background at 10 16 n cm -2 , suggesting that LISe may be suitable for use in neutron imaging sensors at neutron imaging facilities.

36 MATERIALS SCIENCE↗

Improved fission neutron energy discrimination with 4 He detectors through pulse filtering

Our paper presents experimental and computational techniques implemented for 4 He gas scintillation detectorsfor inducedfission neutron detection. Fission neutrons are produced when natural uranium samples are activelyinterrogated by 2.45 MeV deuterium-deuterium fusion reaction neutrons. Fission neutrons of energies greaterthan 2.45 MeV can be distinguished by their different scintillation pulse height spectra since 4 He detectorsretain incident fast neutron energy information. To enable the preferential detection of fast neutrons up to10 MeV and suppress low-energy event counts, the detector photomultiplier gain is lowered and triggerthreshold is increased. Pile-up and other unreliable events due to the interrogating neutronflux and backgroundradiation arefiltered out prior to the evaluation of pulse height spectra. With these problem-specific calibrationsand data processing, the 4 He detector's accuracy at discriminatingfission neutrons up to 10 MeV is improvedand verified with 252 Cf spontaneousfission neutrons. Given the 4 He detector's ability to differentiate fastneutron sources, this proof-of-concept active-interrogation measurement demonstrates the potential of specialnuclear materials detection using a 4 He fast neutron detection system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental validation of a high fidelity Monte Carlo neutron transport model of the MIT graphite exponential pile

High-fidelity modeling and simulation were performed for the MIT graphite exponential pile (MGEP) using Monte Carlo neutron transport codes OpenMC and MCNP, and the results were validated by experimental data. The MGEP is being used as the test bed for the design of an autonomous control system for the pile's neutron flux distribution. The main contribution of this work is to generate the training data sets of neutron flux distributions with different locations of control rods that perturb the neutron flux profiles. First, code -to-code cross verification between OpenMC and MCNP was performed to ensure consistency of the numerical modeling within statistical uncertainties. To validate the accuracy of this high-fidelity model, a series of neutron flux measurements were conducted using a Helium-3 (He-3) neutron detector on a mobile platform that is placed inside the pile. Second, the neutron flux profiles were measured in four vertical layers of interest, and compared to the corresponding simulation results. The comparison results shows that the root mean square error is less than 2.5% in the two upper layers, and less than 4.5% in all four measured layers. Here the results validated the accuracy of the modeling and simulation. Finally, the relative change of the neutron flux profiles from moving control rods was analyzed, which identified the layer that has the best sensitivity regarding the control rods movements. Thus, this work identified and provided training data sets of both simulated and experimental neutron flux profiles in the most sensitive layer, paving the path forward to the real-time experimental demonstration of the autonomous control system.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Novel techniques for constraining neutron-capture rates relevant for r -process heavy-element nucleosynthesis

The rapid-neutron capture process (r process) is identified as the producer of about 50% of elements heavier than iron. This process requires an astrophysical environment with an extremely high neutron flux over a short amount of time ( seconds), creating very neutron-rich nuclei that are subsequently transformed to stable nuclei via beta decay. In 2017, one site for the r process was confiimed: the advanced LIGO and advanced Virgo detectors observed two neutron stars merging, and immediate follow-up measurements of the electromagnetic transients demonstrated an "afterglow" over a broad range of frequencies fully consistent with the expected signal of an r process taking place. Although neutronstar mergers are now known to be r-process element factories, contributions from other sites are still possible, and a comprehensive understanding and description of the r process is still lacking. One key ingredient to large-scale r-process reaction networks is radiative neutron-capture ( n , γ ) rates, for which there exist virtually no data for extremely neutron rich nuclei involved in the r process. Due to the current status of nuclear-reaction theory and our poor understanding of basic nuclear properties such as level densities and average g-decay strengths, theoretically estimated ( n , γ ) rates may vary by orders of magnitude and represent a major source of uncertainty in any nuclear-reaction network calculation of r-process abundances. Here in this review, we discuss new approaches to provide information on neutron-capture cross sections and reaction rates relevant to the r process. In particular, we focus on indirect, experimental techniques to measure radiative neutron-capture rates. While direct measurements are not available at present, but could possibly be realized in the future, the indirect approaches present a first step towards constraining neutron-capture rates of importance to the r process.

(n, γ,) cross sections↗