Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NOISE REDUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Experimental measurements of moving noise sources

The far-field pressure was measured from three different types of moving sources: a point monopole, a small model jet, and an aircraft. Results for the pressure time history produced by the point source show good agreement with those predicted analytically. Both actual and simulated forward motion of the model jet show reductions in noise levels with forward speed at all angles between the source and observer. Measurement with the aircraft over both an anechoic floor and over the ground yields a method for evaluating the transfer function for ground reflections at various angles between the moving aircraft and measurement position.

Maestrello, L.↗

Liquid crystal polymer receiver modules for electron cyclotron emission imaging on the DIII-D tokamak

A new generation of millimeter-wave heterodyne imaging receiver arrays has been developed and demonstrated on the DIII-D electron cyclotron emission imaging (ECEI) system. Improved circuit integration, improved noise performance, and enhanced shielding from out-of-band emission are made possible by using advanced liquid crystal polymer (LCP) substrates and monolithic microwave integrated circuit (MMIC) receiver chips. This array exhibits ~15 dB additional gain and >30× reduction in noise temperature compared to previous generation ECEI arrays. Each LCP horn-waveguide module houses a 3 × 3 mm GaAs MMIC receiver chip, which consists of a low noise millimeter-wave preamplifier, balanced mixer, and IF amplifier together with a local oscillator multiplier chain driven at ~12 GHz. A proof-of-principle partial LCP instrument with 5 poloidal channels was installed on DIII-D in 2017, with a full proof-of-principle system (20 poloidal × 8 radial channels) installed and commissioned in early 2018. The enhanced shielding of the LCP modules is seen to greatly reduce the sensitivity of ECEI signals to out-of-band microwave noise which has plagued previous ECEI studies on DIII-D. As a result, the LCP ECEI system is expected to be a valuable diagnostic tool for pedestal region measurements, focusing particularly on electron temperature evolution during edge localized mode bursting.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noise suppression by active optics in low-dose electron microscopy

Low-dose electron microscopy of radiation sensitive biological specimens achieves only limited resolution because of the inherently weak signal buried in noise. Here, we propose to reduce the noise by using a deformable mirror similar to the Castaing-Henry device to manipulate phase of the electron waves. The method takes advantage of quantum nature of the measurement and nonrandomness of any specimen structure of interest. The simulation revealed 9.7% reduction of noise for the representative case of the ribosome. Increasingly better figures are expected as knowledge about a specimen improves.

43 PARTICLE ACCELERATORS↗

Effect of individual blade control on noise radiation

In a joint research program of NASA Ames Research Center, ZF Luftfahrttechnik, the German Aerospace Research Establishment (DLR), and EUROCOPTER Deutschland, a wind tunnel test was performed to evaluate the effects of Individual Blade Control (IBC) on rotor noise. This test was conducted in the 40x80 ft wind tunnel at NASA Ames Research Center, utilizing a full scale MBB-BO 105 four-bladed rotor system. Three microphones were installed for determination of the radiated noise, two of them on a moveable traverse below the advancing blade side and one in a fixed location below the retreating side. Acoustic results are presented for flight conditions with Blade-Vortex-Interaction (BVI) noise radiation. High noise level reductions were measured for single harmonic control inputs. In addition to the single harmonic inputs, multi-harmonic inputs were evaluated by superimposing 2/rev to 6/rev harmonics. For the first time the efficiency of sharp wavelets (60 deg and 90 deg width) on acoustic noise were measured. In order to achieve an adequate wavelet shape at the blade tip, corrections were made to account for the blade torsional behavior. In parallel with the acoustic measurements, vibratory loads were measured during the BVI flight condition to correlate the effects of IBC on noise and vibrations. It is shown how noise levels and vibrations are affected by specific IBC control inputs. In addition, correlations are made between noise levels and acoustic time histories with IBC phase and amplitude variations. For one IBC input mode with high noise reducing efficiency, a sweep of the moveable microphone traverse below the advancing side shows the effect on BVI noise directivity.

Swanson, S. M.↗

Concepts for reduction of blade-vortex interaction noise

A model is developed to determine the critical parameters that control noise generation by blade-vortex interaction (BVI). The equations for evaluation BVI are derived. The analysis of BVI using the model reveals that the interaction is dependent on incoming vortex strength, blade lift, the interaction length, and the miss distance of the interaction. Several methods for reduction of the noise source are proposed.

Hardin, J. C.↗

TH-C-18A-01: Is Automatic Tube Current Modulation Still Necessary with Statistical Iterative Reconstruction?

Purpose: Automatic tube current modulation (TCM) has been widely used in modern multi-detector CT to reduce noise spatial nonuniformity and streaks to improve dose efficiency. With the advent of statistical iterative reconstruction (SIR), it is expected that the importance of TCM may diminish, since SIR incorporates statistical weighting factors to reduce the negative influence of photon-starved rays. The purpose of this work is to address the following questions: Does SIR offer the same benefits as TCM? If yes, are there still any clinical benefits to using TCM? Methods: An anthropomorphic CIRS chest phantom was scanned using a state-of-the-art clinical CT system equipped with an SIR engine (Veo™, GE Healthcare). The phantom was first scanned with TCM using a routine protocol and a low-dose (LD) protocol. It was then scanned without TCM using the same protocols. For each acquisition, both FBP and Veo reconstructions were performed. All scans were repeated 50 times to generate an image ensemble from which noise spatial nonuniformity (NSN) and streak artifact levels were quantified. Monte-Carlo experiments were performed to estimate skin dose. Results: For FBP, noise streaks were reduced by 4% using TCM for both routine and LD scans. NSN values were actually slightly higher with TCM (0.25) than without TCM (0.24) for both routine and LD scans. In contrast, for Veo, noise streaks became negligible (<1%) with or without TCM for both routine and LD scans, and the NSN was reduced to 0.10 (low dose) or 0.08 (routine). The overall skin dose was 2% lower at the shoulders and more uniformly distributed across the skin without TCM. Conclusion: SIR without TCM offers superior reduction in noise nonuniformity and streaks relative to FBP with TCM. For some clinical applications in which skin dose may be a concern, SIR without TCM may be a better option. K. Li, W. Zhao, D. Gomez-Cardona: Nothing to disclose; G.-H. Chen: Research funded, General Electric Company Research funded, Siemens AG Research funded, Varian Medical Systems, Research funded, Hologic, Inc.

60 APPLIED LIFE SCIENCES↗

Principal Component Noise Filtering for NAST-I Radiometric Calibration

The National Polar-orbiting Operational Environmental Satellite System (NPOESS) Airborne Sounder Testbed- Interferometer (NAST-I) instrument is a high-resolution scanning interferometer that measures emitted thermal radiation between 3.3 and 18 microns. The NAST-I radiometric calibration is achieved using internal blackbody calibration references at ambient and hot temperatures. In this paper, we introduce a refined calibration technique that utilizes a principal component (PC) noise filter to compensate for instrument distortions and artifacts, therefore, further improve the absolute radiometric calibration accuracy. To test the procedure and estimate the PC filter noise performance, we form dependent and independent test samples using odd and even sets of blackbody spectra. To determine the optimal number of eigenvectors, the PC filter algorithm is applied to both dependent and independent blackbody spectra with a varying number of eigenvectors. The optimal number of PCs is selected so that the total root-mean-square (RMS) error is minimized. To estimate the filter noise performance, we examine four different scenarios: apply PC filtering to both dependent and independent datasets, apply PC filtering to dependent calibration data only, apply PC filtering to independent data only, and no PC filters. The independent blackbody radiances are predicted for each case and comparisons are made. The results show significant reduction in noise in the final calibrated radiances with the implementation of the PC filtering algorithm.

Tian, Jialin↗

Computerized Generation and Simulation of Meshing and Contact of New Type of Novikov-Wildhaber Helical Gears

In this report, we propose a new geometry for low-noise, increased-strength helical gears of the Novikov-Wildhaber type. Contact stresses are reduced as a result of their convex-concave gear tooth surfaces. The gear tooth surfaces are crowned in the profile direction to localize bearing contact and in the longitudinal direction to obtain a parabolic function of transmission errors. Such a function results in the reduction of noise and vibrations. Methods for the generation of the proposed gear tooth surfaces by grinding and hobbing are considered, and a tooth contact analysis (TCA) computer program to simulate meshing and contact is applied. The report also investigates the influence of misalignment on transmission errors and shift of bearing contact. Numerical examples to illustrate the developed approaches are proposed. The proposed geometry was patented by Ford/UIC (Serial Number 09-340-824, pending) on June 28, 1999.

Litvin, Faydor L.↗

Trajectory Generation for Noise-Constrained Autonomous Flight Operations

One of the major factors in acceptance of aircraft operating in urban areas is noise. In this work, we build on a framework for trajectory generation in order to account for limits on acousticmetrics at one ormore observer locations. The spatial trajectories are generated using Bézier polynomials and satisfy dynamic, acoustic, and mission constraints. The trajectories also guarantee spatial or temporal separation between vehicles for multi-vehicle operations. A simulation example is provided that demonstrates the reduction in noise levels at a set of measurement locations.

Ackerman, Kasey A.↗

Mixer nozzle-externally blown flap noise tests

A summary is given of the noise suppression tests conducted for the STOL aircraft. The tests were made using a large scale mixer nozzle and externally blown flap model. Data were obtained over a range of nozzle exhaust velocities (172 to 284 m/sec) and flap angles. Comparisons were made between the results of the mixer nozzle and those obtained with a standard single convergent nozzle. The resulting conclusions show that a reduction in noise level did occur using the mixer nozzle system.

Goodykoontz, J. H.↗

Inflight simulation experiments on turbulent jet mixing noise

The effects of aircraft forward motion on pure turbulent mixing noise from unheated jets are examined experimentally in the inflight simulation mode. Both acoustic and flow characteristics are determined by testing model-scale nozzles in an anechoic free-jet facility and a wind tunnel, respectively. Scaling laws are derived from each set of experiments and are found to be complementary. The implications are discussed in detail. In particular, it is shown that the measured reduction in noise at 90 deg to the jet axis is a pure source alteration effect.

Tanna, H. K.↗

On the Vortex Sound from Rotating Rods

The motion of different bodies imersed in liquid or gaseous media is accompanied by characteristic sound which is excited by the formation of unstable surfaces of separation behind the body, usually disintegrating into a system of discrete vortices(such as the Karman vortex street due to the flow about an infintely long rod, etc.).In the noise from fans,pumps,and similar machtnery, vortexnQif3eI?Yequently predominates. The purpose of this work is to elucidate certain questions of the dependence ofthis sound upon the aerodynamic parameters and the tip speed of the rotating rods,or blades. Although scme material is given below,insufficientto calculate the first rough approximation to the solution of this question,such as the mechanics of vortex formation,never the less certain conclusions maybe found of practical application for the reduction of noise from rotating blades.

Yudin, E. Y.↗

The feasibility of a piecewise-linear dynamic bowtie filter

Purpose: The prepatient attenuator (or 'bowtie filter') in CT is used to modulate the flux as a function of fan angle of the x-ray beam incident on the patient. Traditional, static bowtie filters are tailored only for very generic scans and for the average patient. The authors propose a design for a dynamic bowtie that can produce a time-dependent piecewise-linear attenuation profile. This dynamic bowtie may reduce dynamic range, dose or scatter, but in this work they focus on its ability to reduce dynamic range, which may be particularly important for systems employing photon-counting detectors. Methods: The dynamic bowtie is composed of a set of triangular wedges. Each wedge is independently moved in order to produce a time-dependent piecewise-linear attenuation profile. Simulations of the bowtie are conducted to estimate the dynamic range reduction in six clinical datasets. The control of the dynamic bowtie is determined by solving a convex optimization problem, and the dose is estimated using Monte Carlo techniques. Beam hardening artifacts are also simulated. Results: The dynamic range is reduced by factors ranging from 2.4 to 27 depending on the part of the body studied. With a dynamic range minimization objective, the dose to the patient can be reduced from 6% to 33% while maintaining peak image noise. Further reduction in dose may be possible with a specific dose reduction objective. Beam hardening artifacts are suppressed with a two-pass algorithm. Conclusions: A dynamic bowtie producing a time-dependent, piecewise-linear attenuation profile is possible and can be used to modulate the flux of the scanner to the imaging task. Initial simulations show a large reduction in dynamic range. Several other applications are possible.

60 APPLIED LIFE SCIENCES↗

Noise generated by convected gusts interacting with swept airfoil cascades

An analysis is developed for the noise generated by the interaction of a rotor viscous wake with a cascade of swept stator vanes. The stator vanes span a channel formed by infinite parallel walls and containing a subsonic mean flow. High frequency interactions, for which the noise generation is concentrated at the vane leading edge, are considered. The analysis utilizes a superposition of the solution to the isolated stator vane problem, presented in an earlier paper, to develop an approximate solution to the cascade problem. The rotor wake model includes the features of wake circumferential lean and a linear spanwise variation of the magnitude of the wake deficit velocity. Calculations are presented which show that, for rotor wakes with moderate circumferential lean, stator sweep produces substantial reductions in noise level. The vane sweep must be oriented to enhance the phase lags along the vane leading edge produced by wake lean. The noise levels are found to be fairly insensitive to spanwise variations in the wake deficit.

Envia, E.↗

Importance sampling variance reduction for the Fokker–Planck rarefied gas particle method

The Fokker–Planck approximation to the Boltzmann equation, solved numerically by stochastic particle schemes, is used to provide estimates for rarefied gas flows. This paper presents a variance reduction technique for a stochastic particle method that is able to greatly reduce the uncertainty of the estimated flow fields when the characteristic speed of the flow is small in comparison to the thermal velocity of the gas. The method relies on importance sampling, requiring minimal changes to the basic stochastic particle scheme. We test the importance sampling scheme on a homogeneous relaxation, planar Couette flow and a lid-driven-cavity flow, and find that our method is able to greatly reduce the noise of estimated quantities. Significantly, we find that as the characteristic speed of the flow decreases, the variance of the noisy estimators becomes independent of the characteristic speed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noise suppression for dual-energy CT via penalized weighted least-square optimization with similarity-based regularization

Purpose: Dual-energy CT (DECT) expands applications of CT imaging in its capability to decompose CT images into material images. However, decomposition via direct matrix inversion leads to large noise amplification and limits quantitative use of DECT. Their group has previously developed a noise suppression algorithm via penalized weighted least-square optimization with edge-preservation regularization (PWLS-EPR). In this paper, the authors improve method performance using the same framework of penalized weighted least-square optimization but with similarity-based regularization (PWLS-SBR), which substantially enhances the quality of decomposed images by retaining a more uniform noise power spectrum (NPS). Methods: The design of PWLS-SBR is based on the fact that averaging pixels of similar materials gives a low-noise image. For each pixel, the authors calculate the similarity to other pixels in its neighborhood by comparing CT values. Using an empirical Gaussian model, the authors assign high/low similarity value to one neighboring pixel if its CT value is close/far to the CT value of the pixel of interest. These similarity values are organized in matrix form, such that multiplication of the similarity matrix to the image vector reduces image noise. The similarity matrices are calculated on both high- and low-energy CT images and averaged. In PWLS-SBR, the authors include a regularization term to minimize the L-2 norm of the difference between the images without and with noise suppression via similarity matrix multiplication. By using all pixel information of the initial CT images rather than just those lying on or near edges, PWLS-SBR is superior to the previously developed PWLS-EPR, as supported by comparison studies on phantoms and a head-and-neck patient. Results: On the line-pair slice of the Catphan{sup ©}600 phantom, PWLS-SBR outperforms PWLS-EPR and retains spatial resolution of 8 lp/cm, comparable to the original CT images, even at 90% reduction in noise standard deviation (STD). Similar performance on spatial resolution is observed on an anthropomorphic head phantom. In addition, results of PWLS-SBR show substantially improved image quality due to preservation of image NPS. On the Catphan{sup ©}600 phantom, NPS using PWLS-SBR has a correlation of 93% with that via direct matrix inversion, while the correlation drops to −52% for PWLS-EPR. Electron density measurement studies indicate high accuracy of PWLS-SBR. On seven different materials, the measured electron densities calculated from the decomposed material images using PWLS-SBR have a root-mean-square error (RMSE) of 1.20%, while the results of PWLS-EPR have a RMSE of 2.21%. In the study on a head-and-neck patient, PWLS-SBR is shown to reduce noise STD by a factor of 3 on material images with image qualities comparable to CT images, whereas fine structures are lost in the PWLS-EPR result. Additionally, PWLS-SBR better preserves low contrast on the tissue image. Conclusions: The authors propose improvements to the regularization term of an optimization framework which performs iterative image-domain decomposition for DECT with noise suppression. The regularization term avoids calculation of image gradient and is based on pixel similarity. The proposed method not only achieves a high decomposition accuracy, but also improves over the previous algorithm on NPS as well as spatial resolution.

60 APPLIED LIFE SCIENCES↗

Slot antenna SIS mixers for submillimeter wavelengths

We are developing improved versions of a slot antenna SIS mixer which we have previously described. The initial work demonstrated a double sideband noise temperature of 420 K for a 500 GHz quasi-optical SIS mixer employing a twin-slot antenna on a quartz dielectric substrate. A quartz hyperhemispherical lens is used to focus the incoming radiation onto the twin-slot antenna. The advantages of a twin-slot antenna include a low impedance (35 omega) and a clean, symmetric beam pattern into the dielectric with a 70 percent efficiency. In our original mixer, the radiation was coupled from the two slot antennas onto superconducting microstrip lines which fed the SIS junction. By performing an impedance transformation using tapered lines and by feeding the radiation from the two slots to the junction in parallel, the effective (real) impedance seen by the junction was reduced to just 4 omega. This very low impedance allowed a junction area of 2.3 sq micron to be used at 500 GHz, which was manufactured using optical lithography. However, no attempt was made to tune out the junction capacitance. We estimate that this capacitance reduces the impedance coupling efficiency to eta(sub Z) approx. equals 0.23, for our junction with omega R(sub N) C = 5.3 at 500 GHz. The recent development of techniques using electron-beam lithography to manufacture junctions with very small areas (approx. equals 0.1 sq microns) now allows considerably more flexibility in the design of SIS mixer circuits. We have redesigned the slot-antenna mixer to take advantage of this possibility. In particular, we have included a novel circuit which allows the junction capacitance to be tune out over a broad bandwidth. For instance, mixers designed for 800 GHz using NbN/MgO/NbN junctions with realistic parameters achieve a 3 dB impedance bandwidth of nearly 400 GHz. Furthermore, our circuit uses only short lengths of microstrip and should be less sensitive to RF losses than other designs. The improved impedance match should give a large reduction in noise temperature as compared to our previous mixer. The new devices are currently under fabrication. Further details of the design and any available experimental results are discussed.

Zmuidzinas, Jonas↗

A Fan Design that Meets the NASA Aeronautics Noise Goals

A fan concept was previously identified that would meet the NASA aeronautics goal of a 20 EPNdB reduction in aircraft noise. This was a 2-stage fan with a pressure ratio of 1.15 and a 460 ft/sec tip speed. The 2 stages were identical so that, with the proper synchrophasing, noise from one stage could be used to cancel noise from the other stage. This paper documents the aerodynamic design of the 2-stage fan concept in a 22-in. diameter size for testing in the NASA Glenn 9- by 15-ft wind tunnel. A set of rotor and stator coordinates are listed in the report. Stress and flutter analyses were done on these blades and showed that the design was structurally viable. A noise prediction code, using the blade coordinates and fan flows, indicated that the 2-stage fan would meet the goal of a 20 dB reduction in fan noise.

Dittmar, James↗