Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Effect of in Vivo Deuteration on Structure of Switchgrass Lignin

Biomass deuteration is an effective engineering method that can be used to provide key insights into understanding of biomass recalcitrance and the complex biomass conversion process. In this study, production of deuterated switchgrass was accomplished by growing the plants in 50% D 2 O under hydroponic conditions in a perfusion chamber. Cellulolytic enzyme lignin was isolated from deuterated switchgrass, characterized by Fourier transform infrared (FTIR), gel permeation chromatography (GPC), and nuclear magnetic resonance (NMR) and compared with its protiated control sample to determine the effect of in vivo deuteration on the chemical structure of lignin. FTIR results showed that D 2 O can be taken up by the roots and transported to the leaves, and deuterium was subsequently incorporated into hydroxyl and alkyl groups in the plant and its lignin through photosynthesis. According to GPC results, deuterated lignin had slightly higher molecular weight, presumably due to isotope effects. 31 P and heteronuclear single quantum coherence (HSQC) NMR results revealed that lignin in the deuterated biomass preserved its native physicochemical characteristics. Finally, the conserved characteristics of the deuterated lignin show its great potential applications for structural and dynamic studies of lignocellulose by techniques such as neutron scattering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Empirically testing vaterite structural models using neutron diffraction and thermal analysis

Otoliths, calcium carbonate (CaCO 3 ) ear bones, are among the most commonly used age and growth structures of fishes. Most fish otoliths are comprised of the most dense CaCO 3 polymorph, aragonite. Sturgeon otoliths, in contrast, have been characterized as the rare and structurally enigmatic polymorph, vaterite a metastable polymorph of CaCO 3 . Vaterite is an important material ranging from biomedical to personal care applications although its crystal structure is highly debated. We characterized the structure of sturgeon otoliths using thermal analysis and neutron powder diffraction, which is used non-destructively. We confirmed that while sturgeon otoliths are primarily composed of vaterite, they also contain the denser CaCO 3 polymorph, calcite. For the vaterite fraction, neutron diffraction data provide enhanced discrimination of the carbonate group compared to x-ray diffraction data, owing to the different relative neutron scattering lengths, and thus offer the opportunity to uniquely test the more than one dozen crystal structural models that have been proposed for vaterite. Of those, space group P6 5 22 model, a = 7.1443(4)Å , c = 25.350(4)Å , V = 1121.5(2)Å 3 provides the best fit to the neutron powder diffraction data, and allows for a structure refinement using rigid carbonate groups.

60 APPLIED LIFE SCIENCES↗

High-pressure cell for neutron diffraction with in situ pressure control at cryogenic temperatures

Pressure generation at cryogenic temperatures presents a problem for a wide array of experimental techniques, particularly neutron studies due to the volume of sample required. We present a novel, compact pressure cell with a large sample volume in which load is generated by a bellow. Using a supply of helium gas up to a pressure of 350 bar, a load of up to 78 kN is generated with leak-free operation. In addition, special fiber ports added to the cryogenic center stick allow for in situ pressure determination using the ruby pressure standard. Mechanical stability was assessed using finite element analysis and the dimensions of the cell have been optimized for use with standard cryogenic equipment. Load testing and on-line experiments using NaCl and BiNiO{sub 3} have been done at the WISH instrument of the ISIS pulsed neutron source to verify performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NEET Micro-Pocket Fission Detector – FY 2013 Status Report

A collaboration between the Idaho National Laboratory (INL), the Kansas State University (KSU), and the Commissariat à l'Énergie Atomique et aux Energies Alternatives (CEA), is funded by the Nuclear Energy Enabling Technologies (NEET) program to develop and test Micro-Pocket Fission Detectors (MPFDs), which are compact fission chambers capable of simultaneously measuring thermal neutron flux, fast neutron flux, and temperature within a single package.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Irradiation test about oxidation-resistant graphite in WWR-K research reactor - 18533

Graphite materials are used for the in-core components of High Temperature Gas-cooled Reactor (HTGR). It is desirable to enhance oxidation resistance of graphite to keep much safety margin. SiC coating is the candidate method for this purpose. JAEA and four Japanese graphite companies, Toyo Tanso, Ibiden, Tokai Carbon and Nippon Techno-Carbon are studying to develop oxidation-resistant graphite for the in-core components. Neutron irradiation test with two capsules was carried out by WWR-K research reactor of Institute of Nuclear Physics of the Republic of Kazakhstan (INP) through the International Science and Technology Center (ISTC) partner project. The total irradiation cycles of WWR-K operation was 10 cycles and the total duration was 200 days. Irradiation temperature about 1473 K would be attained. The maximum fast neutron fluence (E>0.18 MeV) for the gas-swept capsule irradiated at a central irradiation hole was preliminary calculated as 1.2x10{sup 25} m{sup -2}, and for the sealed capsule at a peripheral irradiation hole as 4.2x10{sup 24} m{sup -2}. Dimension and weight of the irradiated specimens were measured, and outer surface of the specimens were observed by optical microscope. For the irradiated oxidation resistant graphite, out-of-pile oxidation test will be carried out at an experimental laboratory. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-dose neutron detector project update

These are the slides for a progress review meeting by the sponsor. This is an update on the high-dose neutron detector project. In summary, improvements in both boron coating and signal amplification have been achieved; improved boron coating materials and procedures have increased efficiency by ~ 30-40% without the corresponding increase in the detector plate area; low dead-time via thin cell design (~ 4 mm gas gaps) and fast amplifiers; prototype PDT 8” pod has been received and testing is in progress; significant improvements in efficiency and stability have been verified; use commercial PDT 10 B design and fabrication to obtain a faster path from the research to practical high-dose neutron detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial correction factors for YALINA Booster facility loaded with medium and low enriched fuels

The Bell and Glasstone spatial correction factor is used in analyses of subcritical assemblies to correct the experimental reactivity as function of the detector position. Besides the detector position, several other parameters affect the correction factor: the energy weighting function of the detector, the detector size, the energy-angle distribution of source neutrons, and the reactivity of the subcritical assembly. This work focuses on the dependency of the correction factor on the detector material and it investigates the YALINA Booster subcritical assembly loaded with medium (36%) and low (10%) enriched fuels. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design of a transportable high efficiency fast neutron spectrometer

A transportable fast neutron detection system has been designed and constructed for measuring neutron energy spectra and flux ranging from tens to hundreds of MeV. The transportability of the spectrometer reduces the detector-related systematic bias between different neutron spectra and flux measurements, which allows for the comparison of measurements above or below ground. The spectrometer will measure neutron fluxes that are of prohibitively low intensity compared to the site-specific background rates targeted by other transportable fast neutron detection systems. To measure low intensity high-energy neutron fluxes, a conventional capture-gating technique is used for measuring neutron energies above 20 MeV and a novel multiplicity technique is used for measuring neutron energies above 100 MeV. The spectrometer is composed of two Gd containing plastic scintillator detectors arranged around a lead spallation target. To calibrate and characterize the position dependent response of the spectrometer, a Monte Carlo model was developed and used in conjunction with experimental data from gamma ray sources. Multiplicity event identification algorithms were developed and used with a Cf-252 neutron multiplicity source to validate the Monte Carlo model Gd concentration and secondary neutron capture efficiency. The validated Monte Carlo model was used to predict an effective area for the multiplicity and capture gating analyses. For incident neutron energies between 100 MeV and 1000 MeV with an isotropic angular distribution, the multiplicity analysis predicted an effective area of 500 cm 2 rising to 5000 cm 2 . For neutron energies above 20 MeV, the capture-gating analysis predicted an effective area between 1800 cm 2 and 2500 cm 2 . As a result, the multiplicity mode was found to be sensitive to the incident neutron angular distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas loading apparatus for the Paris-Edinburgh press

We describe the design and operation of an apparatus for loading gases into the sample volume of the Paris-Edinburgh press at room temperature and high pressure. The system can be used for studies of samples loaded as pure or mixed gases as well as for loading gases as pressure-transmitting media in neutron-scattering experiments. The apparatus consists of a high-pressure vessel and an anvil holder with a clamp mechanism. The vessel, designed to operate at gas pressures of up to 150 MPa, is used for applying the load onto the anvils located inside the clamp. This initial load is sufficient for sealing the pressurized gas inside the sample containing gasket. The clamp containing the anvils and the sample is then transferred into the Paris-Edinburgh press by which further load can be applied to the sample. The clamp has apertures for scattered neutron beams and remains in the press for the duration of the experiment. The performance of the gas loading system is illustrated with the results of neutron-diffraction experiments on compressed nitrogen.

43 PARTICLE ACCELERATORS↗

In situ neutron diffraction analyses of temperature and stresses during friction stir processing of Mg-3Al-1Zn magnesium alloy

In this paper, the evolution of temperature and thermal stresses were examined during friction stir processing of a magnesium alloy using in situ neutron diffraction. Measured total lattice strains were de-convoluted into the thermal and stress components. Finally, it shows the maximum temperature of 464 °C and compressive stress distributions up to -52 MPa underneath the tool via the thermo-mechanical deformation in terms of the Zener-Hollomon parameter of 4.51 × 10 10 s -1 .

36 MATERIALS SCIENCE↗

Magnetic field devices for neutron spin transport and manipulation in precise neutron spin rotation measurements

The neutron spin is a critical degree of freedom for many precision measurements using low-energy neutrons. Fundamental symmetries and interactions can be studied using polarized neutrons. Parity-violation (PV) in the hadronic weak interaction and the search for exotic forces that depend on the relative spin and velocity, are two questions of fundamental physics that can be studied via the neutron spin rotations that arise from the interaction of polarized cold neutrons and unpolarized matter. The Neutron Spin Rotation (NSR) collaboration developed a neutron polarimeter, capable of determining neutron spin rotations of the order of 10 -7 rad per meter of traversed material. This paper describes two key components of the NSR apparatus, responsible for the transport and manipulation of the spin of the neutrons before and after the target region, which is surrounded by magnetic shielding and where residual magnetic fields need to be below 100 μG. These magnetic field devices, called input and output coils, provide the magnetic field for adiabatic transport of the neutron spin in the regions outside the magnetic shielding while producing a sharp nonadiabatic transition of the neutron spin when entering/exiting the low-magnetic-field region. In addition, the coils are self contained, forcing the return magnetic flux into a compact region of space to minimize fringe fields outside. The design of the input and output coils is based on the magnetic scalar potential method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Sample cells to investigate solid/liquid interfaces with neutrons

The design of sample cells to study solid/liquid interfaces by neutron reflection is presented. Use of standardized components and a modular design has allowed a wide range of experiments that include grazing incidence scattering and conventional small-angle scattering. Features that reduce background scattering are emphasized. Various flow arrangements to fill and replenish the liquid in the cell as well as continuous stirring are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of high fluence neutron irradiation on transport properties of thermoelectrics

Thermoelectric materials were subjected to high fluence neutron irradiation in order to understand the effect of radiation damage on transport properties. This paper is relevant to the NASA Radioisotope Thermoelectric Generator (RTG) program in which thermoelectric elements are exposed to radiation over a long period of time in space missions. Selected n-type and p-type bismuth telluride materials were irradiated at the High Flux Isotope Reactor with a neutron fluence of 1.3 × 10 18 n/cm 2 (E > 0.1 MeV). The increase in the Seebeck coefficient in the n-type material was partially off-set by an increase in electrical resistivity, making the power factor higher at lower temperatures. For the p-type materials, although the Seebeck coefficient was not affected by irradiation, electrical resistivity decreased slightly. The figure of merit, zT, showed a clear drop in the 300–400 K range for the p-type material and an increase for the n-type material. Considering that the p-type and n-type materials are connected in series in a module, the overall irradiation damages at the device level were limited. Finally, these results, at neutron fluences exceeding a typical space mission, are significant to ensure that the radiation damage to thermoelectrics does not affect the performance of RTGs.

36 MATERIALS SCIENCE↗

K-space algorithmic reconstruction (KAREN): a robust statistical methodology to separate Bragg and diffuse scattering

Diffuse scattering occurring in the Bragg diffraction pattern of a long-range-ordered structure represents local deviation from the governing regular lattice. However, interpreting the real-space structure from the diffraction pattern presents a significant challenge because of the dramatic difference in intensity between the Bragg and diffuse components of the total scattering function. In contrast to the sharp Bragg diffraction, the diffuse signal has generally been considered to be a weak expansive or continuous background signal. In this paper, using 1D and 2D models, it is demonstrated that diffuse scattering in fact consists of a complex array of high-frequency features that must not be averaged into a low-frequency background signal. To evaluate the actual diffuse scattering effectively, an algorithm has been developed that uses robust statistics and traditional signal processing techniques to identify Bragg peaks as signal outliers which can be removed from the overall scattering data and then replaced by statistically valid fill values. This method, described as a 'K-space algorithmic reconstruction' (KAREN), can identify Bragg reflections independent of prior knowledge of a system's unit cell. KAREN does not alter any data other than that in the immediate vicinity of the Bragg reflections, and reconstructs the diffuse component surrounding the Bragg peaks without introducing discontinuities which induce Fourier ripples or artifacts from underfilling `punched' voids. The KAREN algorithm for reconstructing diffuse scattering provides demonstrably better resolution than can be obtained from previously described punch-and-fill methods. The superior structural resolution obtained using the KAREN method is demonstrated by evaluating the complex ordered diffuse scattering observed from the neutron diffraction of a single plastic crystal of CBr 4 using pair distribution function analysis.

36 MATERIALS SCIENCE↗

The development of a high sensitivity neutron displacement damage sensor

Here, the capability to characterize the neutron energy spectrum and fluence received by a test object is crucial to under-standing the damage effects observed in electronic components. For nuclear research reactors and high energy density physics fa-cilities this can pose exceptional challenges, especially with low level neutron fluences. An ASTM test method for characterizing neutron environments utilizes the 2N2222A transistor as a 1-MeV equivalent neutron fluence sensor and is applicable for environ-ments with 1 x 10 12 - 1 x 10 14 1-MeV(Si)-Eqv.-n/cm 2 . In this work we seek to extend the range of this test method to lower fluence environments utilizing the 2N1486 transistor. Here, the 2N1486 is shown to be an effective neutron displacement damage sensor as low as 1 x 10 10 1-MeV(Si)-Eqv.-n/cm 2 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗