Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

A simple method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter

Purpose: The aim of this study was to develop a computerized method to quantify the coincidence between portal image graticules and radiation field centers or radiation isocenter. Three types of graticules were included in this study: Megavoltage (MV) mechanical graticule, MV electronic portal imaging device digital graticule, and kilovoltage (kV) on-board imaging digital graticule. Methods: A metal ball bearing (BB) was imaged with MV and kV x-ray beams in a procedure similar to a Winston-Lutz test. The radiation fields, graticules, and BB were localized in eight portal images using Hough transform-based computer algorithms. The center of the BB served as a static reference point in the 3D space so that the distances between the graticule centers and the radiation field centers were calculated. The radiation isocenter was determined from the radiation field centers at different gantry angles. Results: Misalignments of MV and kV portal imaging graticules varied with the gantry or x-ray source angle as a result of mechanical imperfections of the linear accelerator and its imaging system. While the three graticules in this study were aligned to the radiation field centers and the radiation isocenter within 2.0 mm, misalignments of 1.5-2.0 mm were found at certain gantry angles. These misalignments were highly reproducible with the gantry rotation. Conclusions: A simple method was developed to quantify the alignments of portal image graticules directly against the radiation field centers or the radiation isocenter. The advantage of this method is that it does not require the BB to be placed exactly at the radiation isocenter through a precalibrated surrogating device such as room lasers or light field crosshairs. The present method is useful for radiation therapy modalities that require high-precision portal imaging such as image-guided stereotactic radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural Loading on the QCM/SAW Instrument Aboard the ER-2 Used for Atmospheric Testing

Several experiments have been proposed to capture and evaluate samples of the atmosphere where SST's travel. One means to achieve this is to utilize the quartz crystal microbalance (QCM) / surface acoustical wave (SAW) instrument installed aboard the ER-2, formerly the U-2 reconnaissance aircraft. The QCM is a cascade impactor designed to perform in-situ, real-time measurements of aerosols and chemical vapors at an altitude of 60,000-70,000 feet. The primary use of the ER-2 is by NASA for Earth resources to test new sensor systems before being placed aboard satellites. One of the main reasons the ER-2 is used for this flight experiment is its capability to fly approximately twelve miles above the sea level (can reach an altitude of 78,000 feet). Because the ER-2 operates at such a high altitude, it is of special interest to scientists interested in space exploration or supersonic aircraft. The purpose of some of the experiments is to extinct data from the atmosphere around the ER-2. For the current CSTEA flight experiment, the housing of the QCM is in a frame that connects to an outer pod that attaches to the fuselage of the ER-2. Due to the location of the QCM within the housing frame and the location of the pod on the ER-2, the pod and its contents are subject to structural loads. In addition to structural loads, structural vibrations are also of importance because the QCM output data is based on the determination of beat frequencies between a pair of oscillators (one coated, the second uncoated, according to the chemical reaction being monitored). A structural analysis of this system can indicate whether potential resonances may exist between the (higher) structural modal frequencies and the beat frequencies. In addition undesirable deformations may result due to maximum expected static or dynamic loads during typical flight conditions. If the deformations are excessive they may adversely affect the accuracy the instrumentation output.

Bainum, Peter M.↗

An explainable variational autoencoder model for three-dimensional acoustic emission source localization in hollow cylindrical structures

We introduce an explainable variational autoencoder for three-dimensional (3D) localization of acoustic emission sources in hollow cylindrical structures, with an unsupervised approach. This research capitalizes on multi-arrival waveforms generated by helical path propagation in cylindrical geometries to enable efficient two-receiver localization. By integrating the modal characteristics of Lamb modes under multi-path conditions, we demonstrate that two sets of time-of-arrival differences and peak amplitudes extracted from one receiver can serve as effective localization features. This initial approach identifies four potential source locations, highlighting the feasibility of two-receiver source localization using traditional feature extraction methods. However, direct extraction can be challenging when mode overlaps occur, complicating the localization process. To address this, our work proposes a novel waveform-based method. This method leverages the consistent dispersion characteristics within isotropic materials, where each unique combination of mode arrival times and peak amplitudes constructs a distinct waveform. This distinctiveness overcomes the ambiguities associated with mode overlaps, significantly enhancing the method’s precision and robustness. Our approach adopts a data-driven strategy for waveform-based localization using variational autoencoder (VAE). VAE discerns waveform patterns for localization, while also addressing data uncertainties. The VAE’s encoder and decoder networks capture the localization process and the source’s influence on waveform generation, respectively, guiding latent variables to segregate waveforms by source in the latent space. The design of the learning process focuses on specific localization characteristics to enhance result explainability. Localization predictions are generated by projecting test waveforms, not included in the training set, onto a trained latent space. The prediction is determined using a nearest-neighbor approach based on the closest latent representation of a source. Validation with pencil-lead-break tests on a metallic pipe confirmed our method’s effectiveness, achieving an averaged 3D localization accuracy of 0.84.

Lee, Guan-Wei↗

Fourier method for 3-dimensional data fusion of X-ray Computed Tomography and ultrasound

X-ray Computed Tomography (CT) is essential for nondestructive inspection of many manufactured components but is susceptible to various forms of artifacts and noise. In particular, multi-detector row cone-beam CT systems can suffer from so called “cone-beam” artifacts and partial volume effects, particularly on planar edges at the periphery of the field of view in the cone angle dimension. Uni-directional ultrasonic testing methods generally have extremely accurate in-plane depth resolution but poorer lateral resolution due to physical and geometric constraints. This paper presents a novel technique called Computed Tomographic Fusion (CT-F) which uses three-dimensional Fourier filtering to combine x-ray cone-beam CT reconstructions and ultrasound data in the frequency space. The result is a single image with improved accuracy and quality. CT-F mitigates artifacts while allowing for rapid, accurate characterization of large three-dimensional CT volumes. Finally, using simulations and experiments, we demonstrate artifact reduction and edge contrast improvement in volumetric reconstructions.

42 ENGINEERING↗

A high-order Lagrangian discontinuous Galerkin hydrodynamic method for quadratic cells using a subcell mesh stabilization scheme

We present here a Lagrangian discontinuous Galerkin (DG) hydrodynamic method that is up to third-order accurate using subcell mesh stabilization (SMS) for compressible flows on quadratic meshes in two-dimensional (2D) Cartesian coordinates. Similar to the second-order accurate Lagrangian DG method with linear meshes, the physical evolution equations for the specific volume, velocity, and specific total energy are discretized using a modal DG method with Taylor series polynomials. The Riemann velocity at the vertices of a curvilinear cell, and the corresponding surface forces, are calculated by solving a multidirectional approximate Riemann problem. Curvilinear cells (e.g., quadratic quadrilateral meshes in this work) have many deformational degrees of freedom, and with these cells, they can deform in unphysical ways. Likewise, the Riemann solution at an edge vertex differs from the one at the corner of a cell. With SMS, each quadratic quadrilateral cell is decomposed into four quadrilateral subcells, that move in a Lagrangian manner. The edge vertex is surrounded by four subcells so that it is similar to the vertex at the cell corner. SMS can detect inconsistent density fields between the cell and subcells. The difference between these two density fields is used to correct the stress (pressure) input to the Riemann solver. This SMS scheme enables stable mesh motion and accurate solutions in the context of a Lagrangian high-order DG method that is up to third-order with quadratic cells. We also present effective limiting strategies that ensure monotonicity of the primitive variables with the high-order DG method. This Lagrangian DG hydrodynamic method with SMS conserves mass, momentum, and total energy. A suite of test problems are calculated to demonstrate the designed order of accuracy (up to third-order accurate) of this method, and that the Lagrangian DG method using SMS preserves cylindrical symmetry on 1D radial flow problems with an equal-angle polar quadratic mesh.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mars Sample Receiving Facility Research and Development to Enable Preservation, Safe Containment, and Scientific Research of Martian Samples on Earth

NASA and ESA are working together to plan a joint campaign to potentially bring back the first Martian samples to Earth in the early 2030s. On the surface of Mars, the Mars 2020Perseverance Rover is selecting and packaging samples that could be returned to Earth for careful examination by an international team of scientists. In preparation for this historic sample return, advance planning is underway to design and build a Mars Sample Receiving Facility (SRF) in the mid-2020s. In 2022, a Mars Sample Receiving Facility Assessment Study(MSAS) will be conducted to further define construction modality and capability options for a facility in the conterminous United States. Since Mars Sample Return (MSR) is currently categorized as a planetary protection restricted Earth return, this new facility would feature biosafety level 4 (BSL-4)-like high containment to protect Earth’s biosphere from any potential hazard. In addition, the facility also requires integration of cleanroom technologies to mitigate against terrestrial contamination and preserve sample integrity for science investigations. The integration of both clean handling and high containment requires significant technology research and development (R&D) by the mid-2020s to support the definition and planning of a SRF before commencing the site specific design phase. The SRF project will need to solidify the inorganic, organic, and biological contamination control (CC) requirements for the facility. This could entail a translation of Mars 2020 mission CC requirements for geologic material to engineering requirements for surfaces and airborne molecular contamination inside isolators and cleanrooms. In tandem, the project will need to determine precision cleaning and sterilization approaches for cleanrooms, isolators, equipment, and tools. Initial material selections for the facility construction materials, cleanrooms, isolators, and BSL-4 suits/garments are an important activity. The recent construction of the OSIRIS-REx and Hayabusa2 curation cleanroom laboratories greatly benefited from early materials testing, before the design phase, to reduced organic outgassing and particulate shedding inside the laboratory. While the early biohazard investigations in the SRF may deem the samples safe to release to laboratories throughout the world, sterilization methods need to be defined to safely release Martian samples. One key aspect of enabling simultaneous sample containment and cleanliness is the concept of a Double-Walled Isolator (DWI) that ESA has been pursuing. Further R&D is needed about DWIs, sample handling, and instrumentation interfaces before beginning the SRF site specific design phase. A working isolator/DWI engineering model should be developed and fabricated. Isolator sizes, connections, pass-through antechambers, and configurations and basic interfaces with instruments and tools as well as the use of robotic, mechanical, and/or human manipulation need to be considered. Inert high purity gas supply (one-pass or recirculation) and other isolator utilities must be determined. Special accommodations for large instruments (e.g., XCT,SEM, etc.) need to be developed. Techniques for opening the sample tubes packaged by M2020and extracting the headspace gas while keeping samples pristine will be challenging, requiring additional R&D, and engagement of the M2020 project. In addition, careful micromanipulation for subdivision and packaging of samples will also need to be included. These combined R&D activities are important before commencing the SRF design phase to ensure safe biohazard containment, sample preservation, and science integrity for the samples that would be studied in the SRF and in laboratories around the world.

mars sample return↗

Analysis of electrically conductive adhesives in shingled solar modules by X-ray imaging techniques

The failure mechanisms of electrically conductive adhesives (ECAs) in solar modules are difficult to study since the ECA layer is not easily accessible within the module package. In this work, we present two complementary imaging modalities—X-ray radiography and X-ray microcomputed tomography (XCT)—that reveal important morphological features of the ECA within a shingled module. X-ray radiography uses single X-ray projections to provide fast and non-destructive imaging of the shingled interconnection, illuminating the alignment of the ECA relative to the busbars, the size and shape of the ECA, and the presence of voids within it. Through X-ray radiography, we observed, for example, that the average void coverage area of ECA segments reduced from 36.7% to 4.4% when an ECA was cured for 60 s prior to module lamination. XCT is a three-dimensional imaging technique that can identify regions in which the ECA makes electrical contact to busbars on cells and regions in which the ECA has cracked, among other features. XCT can also be used to image the individual metal particles within ECA, from which the metal volume fraction of an ECA was found here to be 70.4%. This is a quantity that is not often reported by ECA manufacturers but is important to ensure isotropic conduction. As X-ray projections can be performed non-destructively on full modules, the technique may be used to pinpoint ECA failures in accelerated degradation testing. XCT is complementary and is suited to forensic analysis of failing modules.

14 SOLAR ENERGY↗

Prostate CT segmentation method based on nonrigid registration in ultrasound-guided CT-based HDR prostate brachytherapy

Purpose: The technological advances in real-time ultrasound image guidance for high-dose-rate (HDR) prostate brachytherapy have placed this treatment modality at the forefront of innovation in cancer radiotherapy. Prostate HDR treatment often involves placing the HDR catheters (needles) into the prostate gland under the transrectal ultrasound (TRUS) guidance, then generating a radiation treatment plan based on CT prostate images, and subsequently delivering high dose of radiation through these catheters. The main challenge for this HDR procedure is to accurately segment the prostate volume in the CT images for the radiation treatment planning. In this study, the authors propose a novel approach that integrates the prostate volume from 3D TRUS images into the treatment planning CT images to provide an accurate prostate delineation for prostate HDR treatment. Methods: The authors’ approach requires acquisition of 3D TRUS prostate images in the operating room right after the HDR catheters are inserted, which takes 1–3 min. These TRUS images are used to create prostate contours. The HDR catheters are reconstructed from the intraoperative TRUS and postoperative CT images, and subsequently used as landmarks for the TRUS–CT image fusion. After TRUS–CT fusion, the TRUS-based prostate volume is deformed to the CT images for treatment planning. This method was first validated with a prostate-phantom study. In addition, a pilot study of ten patients undergoing HDR prostate brachytherapy was conducted to test its clinical feasibility. The accuracy of their approach was assessed through the locations of three implanted fiducial (gold) markers, as well as T2-weighted MR prostate images of patients. Results: For the phantom study, the target registration error (TRE) of gold-markers was 0.41 ± 0.11 mm. For the ten patients, the TRE of gold markers was 1.18 ± 0.26 mm; the prostate volume difference between the authors’ approach and the MRI-based volume was 7.28% ± 0.86%, and the prostate volume Dice overlap coefficient was 91.89% ± 1.19%. Conclusions: The authors have developed a novel approach to improve prostate contour utilizing intraoperative TRUS-based prostate volume in the CT-based prostate HDR treatment planning, demonstrated its clinical feasibility, and validated its accuracy with MRIs. The proposed segmentation method would improve prostate delineations, enable accurate dose planning and treatment delivery, and potentially enhance the treatment outcome of prostate HDR brachytherapy.

60 APPLIED LIFE SCIENCES↗

Role of orientation reference selection in motion sickness

The overall objective of this proposal is to understand the relationship between human orientation control and motion sickness susceptibility. Three areas related to orientation control will be investigated. These three areas are (1) reflexes associated with the control of eye movements and posture, (2) the perception of body rotation and position with respect to gravity, and (3) the strategies used to resolve sensory conflict situations which arise when different sensory systems provide orientation cues which are not consistent with one another or with previous experience. Of particular interest is the possibility that a subject may be able to ignore an inaccurate sensory modality in favor of one or more other sensory modalities which do provide accurate orientation reference information. We refer to this process as sensory selection. This proposal will attempt to quantify subjects' sensory selection abilities and determine if this ability confers some immunity to the development of motion sickness symptoms. Measurements of reflexes, motion perception, sensory selection abilities, and motion sickness susceptibility will concentrate on pitch and roll motions since these seem most relevant to the space motion sickness problem. Vestibulo-ocular (VOR) and oculomotor reflexes will be measured using a unique two-axis rotation device developed in our laboratory over the last seven years. Posture control reflexes will be measured using a movable posture platform capable of independently altering proprioceptive and visual orientation cues. Motion perception will be quantified using closed loop feedback technique developed by Zacharias and Young (Exp Brain Res, 1981). This technique requires a subject to null out motions induced by the experimenter while being exposed to various confounding sensory orientation cues. A subject's sensory selection abilities will be measured by the magnitude and timing of his reactions to changes in sensory environments. Motion sickness susceptibility will be measured by the time required to induce characteristic changes in the pattern of electrogastrogram recordings while exposed to various sensory environments during posture and motion perception tests. The results of this work are relevant to NASA's interest in understanding the etiology of space motion sickness. If any of the reflex, perceptual, or sensory selection abilities of subjects are found to correlate with motion sickness susceptibility, this work may be an important step in suggesting a method of predicting motion sickness susceptibility. If sensory selection can provide a means to avoid sensory conflict, then further work may lead to training programs which could enhance a subject's sensory selection ability and therefore minimize motion sickness susceptibility.

Peterka, Robert J.↗

Hazard Detection Software for Lunar Landing

The Autonomous Landing and Hazard Avoidance Technology (ALHAT) Project is developing a system for safe and precise manned lunar landing that involves novel sensors, but also specific algorithms. ALHAT has selected imaging LIDAR (light detection and ranging) as the sensing modality for onboard hazard detection because imaging LIDARs can rapidly generate direct measurements of the lunar surface elevation from high altitude. Then, starting with the LIDAR-based Hazard Detection and Avoidance (HDA) algorithm developed for Mars Landing, JPL has developed a mature set of HDA software for the manned lunar landing problem. Landing hazards exist everywhere on the Moon, and many of the more desirable landing sites are near the most hazardous terrain, so HDA is needed to autonomously and safely land payloads over much of the lunar surface. The HDA requirements used in the ALHAT project are to detect hazards that are 0.3 m tall or higher and slopes that are 5 or greater. Steep slopes, rocks, cliffs, and gullies are all hazards for landing and, by computing the local slope and roughness in an elevation map, all of these hazards can be detected. The algorithm in this innovation is used to measure slope and roughness hazards. In addition to detecting these hazards, the HDA capability also is able to find a safe landing site free of these hazards for a lunar lander with diameter .15 m over most of the lunar surface. This software includes an implementation of the HDA algorithm, software for generating simulated lunar terrain maps for testing, hazard detection performance analysis tools, and associated documentation. The HDA software has been deployed to Langley Research Center and integrated into the POST II Monte Carlo simulation environment. The high-fidelity Monte Carlo simulations determine the required ground spacing between LIDAR samples (ground sample distances) and the noise on the LIDAR range measurement. This simulation has also been used to determine the effect of viewing on hazard detection performance. The software has also been deployed to Johnson Space Center and integrated into the ALHAT real-time Hardware-in-the-Loop testbed.

Huertas, Andres↗

Robust scalable initialization for Bayesian variational inference with multi-modal Laplace approximations

Predictive modeling typically relies on Bayesian model calibration to provide uncertainty quantification. Variational inference utilizing fully independent (“mean-field”) Gaussian distributions are often used as approximate probability density functions. This simplification is attractive since the number of variational parameters grows only linearly with the number of unknown model parameters. However, the resulting diagonal covariance structure and unimodal behavior can be too restrictive to provide useful approximations of intractable Bayesian posteriors that exhibit highly non-Gaussian behavior, including multimodality. High-fidelity surrogate posteriors for these problems can be obtained by considering the family of Gaussian mixtures. Gaussian mixtures are capable of capturing multiple modes and approximating any distribution to an arbitrary degree of accuracy, while maintaining some analytical tractability. Unfortunately, variational inference using Gaussian mixtures with full-covariance structures suffers from a quadratic growth in variational parameters with the number of model parameters. The existence of multiple local minima due to strong nonconvex trends in the loss functions often associated with variational inference present additional complications, These challenges motivate the need for robust initialization procedures to improve the performance and computational scalability of variational inference with mixture models. In this work, we propose a method for constructing an initial Gaussian mixture model approximation that can be used to warm-start the iterative solvers for variational inference. The procedure begins with a global optimization stage in model parameter space. In this step, local gradient-based optimization, globalized through multistart, is used to determine a set of local maxima, which we take to approximate the mixture component centers. Around each mode, a local Gaussian approximation is constructed via the Laplace approximation. Finally, the mixture weights are determined through constrained least squares regression. The robustness and scalability of the proposed methodology is demonstrated through application to an ensemble of synthetic tests using high-dimensional, multimodal probability density functions. Here, the practical aspects of the approach are demonstrated with inversion problems in structural dynamics.

97 MATHEMATICS AND COMPUTING↗

TU-F-17A-09: Four-Dimensional Cone Beam CT Ventilation Imaging Can Detect Interfraction Lung Function Variations for Locally Advanced Lung Cancer Patients

Purpose: Four-dimensional cone beam CT ventilation imaging (4D-CBCT VI) is a novel functional lung imaging modality requiring validation. We hypothesize that 4D-CBCT VI satisfies a necessary condition for validity: that intrafraction variations (e.g. due to poor 4D-CBCT image quality) are substantially different to interfraction variations (e.g. due to changes in underlying function). We perform the first comparison of intrafraction (pre/post fraction) and interfraction (week-to-week) 4D-CBCT VIs for locally advanced non small cell lung cancer (LA NSCLC) patients undergoing radiation therapy. Methods: A total of 215 4D-CBCT scans were acquired for 19 LA NSCLC patients over 4-6 weeks of radiation therapy, including 75 pairs of pre-/post-fraction scans on the same day. 4D-CBCT VIs were obtained by applying state-of-the-art, B-spline deformable image registration to obtain the Jacobian determinant of deformation between the end-exhale and end-inhale phases. All VIs were deformably registered to the corresponding first day scan, normalized between the 10th and 90th percentile values and cropped to the ipsilateral lung only. Intrafraction variations were assessed by computing the mean and standard deviation of voxel-wise differences between all same-day pairs of pre-/post-fraction VIs. Interfraction differences were computed between first-day VIs and treatment weeks 2, 4 and 6 for all 19 patients. We tested the hypothesis by comparing cumulative distribution functions (CDFs) of intrafraction and interfraction ventilation differences using two-sided Kolmogorov-Smirnov goodness-of-fit tests. Results: The (mean ± std. dev.) of intrafraction differences was (−0.007 ± 0.079). Interfraction differences for weeks 2, 4 and 6 were (−0.035 ± 0.103), (−0.006 ± 0.094) and (−0.019 ± 0.127) respectively. For week 2, the changes in CDFs for intrafraction and interfraction differences approached statistical significance (p=0.099). Conclusion: We have shown that 4D-CBCT VI can satisfy a necessary condition for validity; intrafraction variations do not limit the ability to measure interfraction variations in LA NSCLC patients. This work is supported by a Cancer Institute NSW Early Career Fellowship, an NHMRC Australia Fellowship and NIH P01CA116602.

60 APPLIED LIFE SCIENCES↗

Understanding the Effect of Preparative Approaches in the Formation of “Flower-like” Li 4 Ti 5 O 12 —Multiwalled Carbon Nanotube Composite Motifs with Performance as High-Rate Anode Materials for Li-Ion Battery Applications

Herein we highlight the significance of nanoscale attachment modality as an important determinant of observed electrochemical performance. Specifically, controlled loading ratios of multi-walled carbon nanotubes (MWNTs) have been successfully anchored onto the surfaces of a unique “flower-like” Li 4 Ti 5 O 12 (LTO) micro-scale sphere motif, for the first time, using a number of different and distinctive preparative approaches, including (i) a sonication method, (ii) an in situ direct-deposition approach, (iii) a covalent attachment protocol, as well as (iv) a π-π interaction strategy. In terms of structural characterization, the composites generated by physical sonication as well as non-covalent π-π interactions retained the intrinsic hierarchical “flower-like” morphology and exhibited a similar crystallinity profile as compared with that of pure LTO. By comparison, the composite prepared by an in situ direct deposition approach yielded not only a fragmented LTO structure, likely due to the possible interfering presence of the MWNTs themselves during the relevant hydrothermal reaction, but also a larger crystallite size, owing to the higher annealing temperature associated with its preparation. Finally, the composite created via covalent attachment was covered with an amorphous insulating linker, which probably led to a decreased contact area between the LTO and the MWNTs and hence, a lower crystallinity in the resulting composite. In addition electrode tests suggested that the composite generated by π-π interactions out-performed the other three analogous heterostructures, due to a smaller charge transfer resistance as well as a faster Li-ion diffusion. In particular, the LTO-MWNT composite, produced by π-π interactions, exhibited a reproducibly high rate capability as well as a reliably solid cycling stability, delivering 132 mA h g -1 at 50 C, after 100 discharge/charge cycles, including 40 cycles at a high (>20 C) rate. To conclude, such data denote the highest electrochemical performance measured to date as compared with any LTO-carbon nanotube-based composite materials previously reported, under high discharge rate conditions, and tangibly underscore the correlation between preparative methodology and the resulting performance metrics.

25 ENERGY STORAGE↗

Patch-based generation of a pseudo CT from conventional MRI sequences for MRI-only radiotherapy of the brain

Purpose: In radiotherapy (RT) based on magnetic resonance imaging (MRI) as the only modality, the information on electron density must be derived from the MRI scan by creating a so-called pseudo computed tomography (pCT). This is a nontrivial task, since the voxel-intensities in an MRI scan are not uniquely related to electron density. To solve the task, voxel-based or atlas-based models have typically been used. The voxel-based models require a specialized dual ultrashort echo time MRI sequence for bone visualization and the atlas-based models require deformable registrations of conventional MRI scans. In this study, we investigate the potential of a patch-based method for creating a pCT based on conventional T{sub 1}-weighted MRI scans without using deformable registrations. We compare this method against two state-of-the-art methods within the voxel-based and atlas-based categories. Methods: The data consisted of CT and MRI scans of five cranial RT patients. To compare the performance of the different methods, a nested cross validation was done to find optimal model parameters for all the methods. Voxel-wise and geometric evaluations of the pCTs were done. Furthermore, a radiologic evaluation based on water equivalent path lengths was carried out, comparing the upper hemisphere of the head in the pCT and the real CT. Finally, the dosimetric accuracy was tested and compared for a photon treatment plan. Results: The pCTs produced with the patch-based method had the best voxel-wise, geometric, and radiologic agreement with the real CT, closely followed by the atlas-based method. In terms of the dosimetric accuracy, the patch-based method had average deviations of less than 0.5% in measures related to target coverage. Conclusions: We showed that a patch-based method could generate an accurate pCT based on conventional T{sub 1}-weighted MRI sequences and without deformable registrations. In our evaluations, the method performed better than existing voxel-based and atlas-based methods and showed a promising potential for RT of the brain based only on MRI.

60 APPLIED LIFE SCIENCES↗

A Treatment Planning Method for Sequentially Combining Radiopharmaceutical Therapy and External Radiation Therapy;External beam therapy; Radiopharmaceutical therapy; Three-dimensional dosimetry; Treatment planning

Purpose: Effective cancer treatment generally requires combination therapy. The combination of external beam therapy (XRT) with radiopharmaceutical therapy (RPT) requires accurate three-dimensional dose calculations to avoid toxicity and evaluate efficacy. We have developed and tested a treatment planning method, using the patient-specific three-dimensional dosimetry package 3D-RD, for sequentially combined RPT/XRT therapy designed to limit toxicity to organs at risk. Methods and Materials: The biologic effective dose (BED) was used to translate voxelized RPT absorbed dose (D{sub RPT}) values into a normalized total dose (or equivalent 2-Gy-fraction XRT absorbed dose), NTD{sub RPT} map. The BED was calculated numerically using an algorithmic approach, which enabled a more accurate calculation of BED and NTD{sub RPT}. A treatment plan from the combined Samarium-153 and external beam was designed that would deliver a tumoricidal dose while delivering no more than 50 Gy of NTD{sub sum} to the spinal cord of a patient with a paraspinal tumor. Results: The average voxel NTD{sub RPT} to tumor from RPT was 22.6 Gy (range, 1-85 Gy); the maximum spinal cord voxel NTD{sub RPT} from RPT was 6.8 Gy. The combined therapy NTD{sub sum} to tumor was 71.5 Gy (range, 40-135 Gy) for a maximum voxel spinal cord NTD{sub sum} equal to the maximum tolerated dose of 50 Gy. Conclusions: A method that enables real-time treatment planning of combined RPT-XRT has been developed. By implementing a more generalized conversion between the dose values from the two modalities and an activity-based treatment of partial volume effects, the reliability of combination therapy treatment planning has been expanded.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient ptychographic phase retrieval via a matrix-free Levenberg-Marquardt algorithm

The phase retrieval problem, where one aims to recover a complex-valued image from far-field intensity measurements, is a classic problem encountered in a range of imaging applications. Modern phase retrieval approaches usually rely on gradient descent methods in a nonlinear minimization framework. Calculating closed-form gradients for use in these methods is tedious work, and formulating second order derivatives is even more laborious. Additionally, second order techniques often require the storage and inversion of large matrices of partial derivatives, with memory requirements that can be prohibitive for data-rich imaging modalities. We use a reverse-mode automatic differentiation (AD) framework to implement an efficient matrix-free version of the Levenberg-Marquardt (LM) algorithm, a longstanding method that finds popular use in nonlinear least-square minimization problems but which has seen little use in phase retrieval. Furthermore, we extend the basic LM algorithm so that it can be applied for more general constrained optimization problems (including phase retrieval problems) beyond just the least-square applications. Since we use AD, we only need to specify the physics-based forward model for a specific imaging application; the first and second-order derivative terms are calculated automatically through matrix-vector products, without explicitly forming the large Jacobian or Gauss-Newton matrices typically required for the LM method. We demonstrate that this algorithm can be used to solve both the unconstrained ptychographic object retrieval problem and the constrained “blind” ptychographic object and probe retrieval problems, under the popular Gaussian noise model as well as the Poisson noise model. We compare this algorithm to state-of-the-art first order ptychographic reconstruction methods to demonstrate empirically that this method outperforms best-in-class first-order methods: it provides excellent convergence guarantees with (in many cases) a superlinear rate of convergence, all with a computational cost comparable to, or lower than, the tested first-order algorithms.

36 MATERIALS SCIENCE↗

Toward a Minimal Representation of Aerosols in Climate Models: Description and Evaluation in the Community Atmosphere Model CAM5

A modal aerosol module (MAM) has been developed for the Community Atmosphere Model version 5 (CAM5), the atmospheric component of the Community Earth System Model version 1 (CESM1). MAM is capable of simulating the aerosol size distribution and both internal and external mixing between aerosol components, treating numerous complicated aerosol processes and aerosol physical, chemical and optical properties in a physically based manner. Two MAM versions were developed: a more complete version with seven-lognormal modes (MAM7), and a three-lognormal mode version (MAM3) for the purpose of long-term (decades to centuries) simulations. Major approximations in MAM3 include assuming immediate mixing of primary organic matter (POM) and black carbon (BC) with other aerosol components, merging of the MAM7 fine dust and fine sea salt modes into the accumulation mode, merging of the MAM7 coarse dust and coarse sea salt modes into the single coarse mode, and neglecting the explicit treatment of ammonia and ammonium cycles. Simulated sulfate and secondary organic aerosol (SOA) mass concentrations are remarkably similar between MAM3 and MAM7 as most ({approx}90%) of these aerosol species are in the accumulation mode. Differences of POM and BC concentrations between MAM3 and MAM7 are also small (mostly within 10%) because of the assumed hygroscopic nature of POM, so that freshly emitted POM and BC are wet-removed before mixing internally with soluble aerosol species. Sensitivity tests with the POM assumed to be hydrophobic and with slower aging process increase the POM and BC concentrations, especially at high latitudes (by several times). The mineral dust global burden differs by 10% and sea salt burden by 30-40% between MAM3 and MAM7 mainly due to the different size ranges for dust and sea salt modes and different standard deviations of log-normal size distribution for sea salt modes between MAM3 and MAM7. The model is able to qualitatively capture the observed geographical and temporal variations of aerosol mass and number concentrations, size distributions, and aerosol optical properties. However, there are noticeable biases, e.g., simulated sulfate and mineral dust concentrations at surface over the oceans are too low. Simulated BC concentrations are significant low in the Arctic. There is a low bias in modeled aerosol optical depth on the global scale, especially in the developing counties. There biases in aerosol simulations clearly indicate the need for improvements of aerosol processes (e.g., emission fluxes of anthropogenic aerosols and precursor gases in developing countries, boundary layer nucleation) and properties (e.g., primary aerosol emission size, POM hygroscopicity). In addition the critical role of cloud properties (e.g., liquid water content, cloud fraction) responsible for the wet scavenging of aerosol is highlighted.

54 ENVIRONMENTAL SCIENCES↗

The Design of a Remote Sensing Data Acquisition Campaign for Precision Agriculture and Some Early Results

In the 1970s NASA and the Department of Agriculture attempted to use the new Landsat MSS system for agricultural purposes. The program had relatively little success. With the advent of differential GPS, yield monitors on harvest equipment and higher spatial resolution remote sensing systems it seemed likely the situation should be reexamined. Therefore, a campaign of data acquisition involving remote sensing and other modalities with dependent research was assembled and funded by the Space Grant Consortia in Alabama and Georgia. The design of the remote sensing data acquisition was driven by the biology and physics of the crop system and limited by the available sensor platforms. Major parameters included crop stage, spatial resolution, seasonal and daily weather conditions, and which portion of the EM spectrum would actually capture the most discriminating information. Joint visible and Near IR with Thermal IR would permit use of existing indices, such as greenness, as well as phenomena driven by the plant' s evapotranspiration. Spatial resolution in the 2-5 meter range was chosen, avoiding many complexities caused by aliasing crop row spacing at, higher resolutions yet finer than the harvester's tightest recording rate. This dictates use of an airborne system. Use of an airborne system also makes scheduling around weather much simpler than use of satellite data. Active video calibration was recognized as essential if quantitative measures were ever to be obtained or reproduced. The system would also have to have onboard geoOF1 Based on these elements 3 data acquisitions have been flown. Seven flight lines were flown twice in 1998 and 16 lines flown in 1999. Total raw data is several GBytes. All of the data has now been geometrically corrected and some preliminary analysis accomplished. The thermal bands have an extremely high correlation with yield. For one@test case with corn, correlation in excess of 0.86 was obtained from a data acquisition two months prior to harvest! Soil images show significant within field variation in clay, soil brightness and emissivity. Light wind has been found to effect the reflectance and temperature of broad leaf crops, including soybeans, cotton and peanuts. Clearly, this work has already demonstrated some very important results. With continued development of the remote sensing technology there is good reason to believe this research will soon be able to help the individual farmer.

Rickmanl, D.↗