Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROWAVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

The influence of ions and the induced secondary emission on the nanosecond high-gradient microwave breakdown at metal surface

The mechanism of ultrafast breakdown at metal/vacuum interface in the high-power microwave waveguides is studied. In order to realize the nanosecond discharge, the required ambient gas pressure above the metal surface is approximately calculated as high as several Torr due to the low ionization-rate for high-energy electrons and short pulse. The local high pressure may come from the evaporated microscopic protrusions due to Joule heating and gas desorption. Besides, ions accelerated by the ambient space charge field could obtain sufficient high energy to collide and sputter the metal atoms to increase the ambient pressure. The positive feedbacks during the rapid discharge are studied by particle-in-cell simulation. The relatively high-energy ions could generate secondary electrons. It is shown that, as the positive feedback, the secondary electrons induce the gas desorption and stronger ionization, resulting in ion and electron density increasing as well as sheath field further increasing. As a result, more higher-energy ions bombard metal surface, leading to higher secondary electron yield and higher density plasma generated to cut off the microwave transmission finally. These nonlinear courses realize the ultrafast discharge in waveguides.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimization of the imaging response of scanning microwave microscopy measurements

In this work, we present the analytical modeling and preliminary experimental results for the choice of the optimal frequencies when performing amplitude and phase measurements with a scanning microwave microscope. In particular, the analysis is related to the reflection mode operation of the instrument, i.e., the acquisition of the complex reflection coefficient data, usually referred as S{sub 11}. The studied configuration is composed of an atomic force microscope with a microwave matched nanometric cantilever probe tip, connected by a λ/2 coaxial cable resonator to a vector network analyzer. The set-up is provided by Keysight Technologies. As a peculiar result, the optimal frequencies, where the maximum sensitivity is achieved, are different for the amplitude and for the phase signals. The analysis is focused on measurements of dielectric samples, like semiconductor devices, textile pieces, and biological specimens.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of frequency on microplasmas driven by microwave excitation

The effect of excitation frequency on the breakdown voltage of a microwave (mw) microdischarge and its steady-state plasma parameters is studied by the self-consistent one-dimensional Particle-in-Cell Monte Carlo collisions model. It is found that for microdischarges in which the electron wall losses are significant, an increase in the mw frequency results in a decrease in the breakdown voltage. For conditions in which the electron wall losses become negligible, an increase in the frequency does not influence significantly the breakdown voltage. At the same time, for both regimes, the increase in the frequency results in an increase in the steady-state plasma density. The analysis of the steady-state plasma parameters have shown that the dominant electron heating mechanism is the Joule heating while the stochastic heating is negligible. Also, it is found that the electron energy distribution function consists of two electron groups, namely, slow and fast electrons. The presence of fast electrons in the plasma bulk indicates the non-local nature of microwave excited microdischarges.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Underwater microwave ignition of hydrophobic thermite powder enabled by the bubble-marble effect

Highly energetic thermite reactions could be useful for a variety of combustion and material-processing applications, but their usability is yet limited by their hard ignition conditions. Furthermore, in virtue of their zero-oxygen balance, exothermic thermite reactions may also occur underwater. However, this feature is also hard to utilize because of the hydrophobic properties of the thermite powder, and its tendency to agglomerate on the water surface rather than to sink into the water. The recently discovered bubble-marble (BM) effect enables the insertion and confinement of a thermite-powder batch into water by a magnetic field. Here, we present a phenomenon of underwater ignition of a thermite-BM by localized microwaves. The thermite combustion underwater is observed in-situ, and its microwave absorption and optical spectral emission are detected. The vapour pressure generated by the thermite reaction is measured and compared to theory. The combustion products are examined ex-situ by X-ray photo-electron spectroscopy which verifies the thermite reaction. Potential applications of this underwater combustion effect are considered, e.g., for detonation, wet welding, thermal drilling, material processing, thrust generation, and composite-material production, also for other oxygen-free environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Power combination of a self-coherent high power microwave source

In our previous work, generating two phase-locked high power microwaves (HPMs) in a single self-coherent HPM device has been demonstrated. In this paper, after optimizing the structure of the previous self-coherent source, we design a power combiner with a folded phase-adjustment waveguide to realize power combination between its two sub-sources. Further particle-in-cell simulation of the combined source shows that when the diode voltage is 687 kV and the axial magnetic field is 0.8 T, a combined output microwave with 3.59 GW and 9.72 GHz is generated. The impedance of the combined device is 36 Ω and the total power conversion efficiency is 28%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Microwave assisted transformation of N,N-diphenylamine as precursors of organic light emitting diodes (OLED)

In this research, study on the transformation of N,N-diphenylamine (DPA) using iodine (I2) utilizing solid state Microwave Assisted Organic Synthesis (MAOS) method has been carried out. The reaction was performed by variations of three parameters namely the mole of reagents, the amount and type of solid support (alumina/Al2O3), and the reaction conditions. Experimental results showed that neutral-alumina was a better solid support than basic-alumina. The optimum temperature for the reaction was approximately at 125-133 °C with reaction time of 15 minutes and microwave reactor power at 500-600 W. The separation of the yellowish green product solution with preparative Thin Layer Chromatography (TLC) method using n-hexane:ethyl acetate = 4:1 (v/v) as eluent yielded two fractions (I and II) and both fractions can undergo fluorescence under 365 nm UV light. Based on the LC chromatogram with methanol:water = 95:5 (v/v) as eluent and its corresponding mass spectra (ESI+), fraction I contained three compounds, which were tetracarbazole A, triphenylamine, and impurities in the form of plasticizer such as bis(2-ethylhexyl) phthalate. Fraction II also contained three compounds, which were tetracarbazole C, tetraphenylhydrazine, and plasticizer such as bis(2-ethylhexyl) phthalate. Both FT-IR (KBr disks) and NMR (500 MHz, CDCl{sub 3}) spectra of fraction I and II confirmed the aromatic amine groups in those compounds. The observed fluorescence colors of fraction I and II were violet and violet-blue, respectively. Based on their structures and fluorescence characters, the compounds in fraction I and II have the potential to be used as Organic Light Emitting Diode (OLED) compound precursors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

24 GHz microwave mode converter optimized for superconducting ECR ion source SECRAL

Over-sized round waveguide with a diameter about Ø33.0 mm excited in the TE{sub 01} mode has been widely adopted for microwave transmission and coupling to the ECR (Electron Cyclotron Resonance) plasma with the superconducting ECR ion sources operating at 24 or 28 GHz, such as SECRAL and VENUS. In order to study the impact of different microwave modes on ECRH (Electron Cyclotron Resonance Heating) efficiency and especially the production of highly charged ions, a set of compact and efficient TE{sub 01}-HE{sub 11} mode conversion and coupling system applicable to 24 GHz SECRAL whose overall length is 330 mm has been designed, fabricated and tested. Good agreements between off-line tests and calculation results have been achieved, which indicates the TE{sub 01}-HE{sub 11} converter meets the application design. The detailed results of the optimized coupling system will be presented in the paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A tunable microwave plasma photonic crystal filter

The integration of gaseous plasma elements into a microwave photonic crystal band gap cavity structure allows for active tuning of the device. An alumina rod array microwave photonic crystal waveguide resonator is simulated and characterized through finite difference time domain methods. A gaseous plasma element is integrated into the cavity structure and the effect of plasma density on the transmission properties of the structure is investigated. We show, through both simulations and experiments, that the permittivity of the plasma can be adjusted to shift the peak resonance to allow for both switching and tunability of transmission. The experimentally measured peak shifts in transmission are compared to those simulated and the electron density of the gaseous plasma element is calculated and compared to values determined from the measured discharge current density.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a microwave ion source for ion implantations

A microwave ion source is expected to have a long lifetime, as it has fewer consumables. Thus, we are in the process of developing a microwave ion source for ion implantation applications. In this paper, we report on a newly developed plasma chamber and the extracted P{sup +} beam currents. The volume of the plasma chamber is optimized by varying the length of a boron nitride block installed within the chamber. The extracted P{sup +} beam current is more than 30 mA, at a 25 kV acceleration voltage, using PH{sub 3} gas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A reliable, compact, and repetitive-rate high power microwave generation system

A compact high power microwave (HPM) generation system is described in this paper. The main parts of the HPM system are a Marx generator with a pulse forming line and a magnetron with diffraction output. The total weight and length of the system are 250 kg and 120 cm, respectively. The output microwave power of the HPM system at 550 kV of applied voltage and 0.33 T of magnetic field reaches 1 GW at 2.32 GHz of central frequency with 38 ns of pulse duration, 23% of power conversion efficiency, and Gaussian radiation pattern. In the bursts operation, both time and amplitude jitters are less than 4 ns and lower than 1.5 dB, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic metamaterial aperture for microwave imaging

We present a dynamic metamaterial aperture for use in computational imaging schemes at microwave frequencies. The aperture consists of an array of complementary, resonant metamaterial elements patterned into the upper conductor of a microstrip line. Each metamaterial element contains two diodes connected to an external control circuit such that the resonance of the metamaterial element can be damped by application of a bias voltage. Through applying different voltages to the control circuit, select subsets of the elements can be switched on to create unique radiation patterns that illuminate the scene. Spatial information of an imaging domain can thus be encoded onto this set of radiation patterns, or measurements, which can be processed to reconstruct the targets in the scene using compressive sensing algorithms. We discuss the design and operation of a metamaterial imaging system and demonstrate reconstructed images with a 10:1 compression ratio. Dynamic metamaterial apertures can potentially be of benefit in microwave or millimeter wave systems such as those used in security screening and through-wall imaging. In addition, feature-specific or adaptive imaging can be facilitated through the use of the dynamic aperture.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Creating tuneable microwave media from a two-dimensional lattice of re-entrant posts

The potential capabilities of resonators based on two dimensional arrays of re-entrant posts is demonstrated. Such posts may be regarded as magnetically coupled lumped element microwave harmonic oscillators, arranged in a 2D lattices structure, which is enclosed in a 3D cavity. By arranging these elements in certain 2D patterns, we demonstrate how to achieve certain requirements with respect to field localisation and device spectra. Special attention is paid to symmetries of the lattices, mechanical tuning, design of areas of high localisation of magnetic energy; this in turn creates unique discrete mode spectra. We demonstrate analogies between systems designed on the proposed platform and well known physical phenomena such as polarisation, frustration, and Whispering Gallery Modes. The mechanical tunability of the cavity with multiple posts is analysed, and its consequences to optomechanical applications is calculated. One particular application to quantum memory is demonstrated with a cavity design consisting of separate resonators analogous to discrete Fabry–Pérot resonators. Finally, we propose a generalised approach to a microwave system design based on the concept of Programmable Cavity Arrays.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Superstrong coupling of thin film magnetostatic waves with microwave cavity

We experimentally demonstrated the strong coupling between a microwave cavity and standing magnetostatic magnon modes in a yttrium iron garnet film. Such strong coupling can be observed for various spin wave modes under different magnetic field bias configurations, with a coupling strength inversely proportional to the transverse mode number. A comb-like spectrum can be obtained from these high order modes. The collectively enhanced magnon-microwave photon coupling strength is comparable with the magnon free spectral range and therefore leads to the superstrong coupling regime. Our findings pave the road towards designing a new type of strongly hybridized magnon-photon system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microwave-induced zero-resistance state in two-dimensional electron systems with unidirectional periodic modulation

In this study we fabricated lateral superlattices (LSLs) based on the selectively doped GaAs/AlAs heterostructures with a high-mobility two-dimensional (2D) electron gas. The LSLs were formed using the electron-beam lithography and lift-off techniques, which produced a set of metallic strips on top of a heterojunction. The amplitude of the 2D electron gas modulation in the LSL was controlled by the gate voltage applied to the metallic strips. The LSLs with two different periods (a = 200 nm and 500 nm) were used to investigate the influence of microwave radiation with the frequency of 110–150 GHz on the 2D electron transport at the temperature T = 1.6 K in the magnetic field B < 1 T. We have found that zero-resistance states (ZRSs) appear under the microwave radiation in the 2D systems with a unidirectional periodic modulation. These ZRSs are located at the minima of commensurability oscillations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coupling of microwave magnetic dynamics in thin ferromagnetic films to stripline transducers in the geometry of the broadband stripline ferromagnetic resonance

We constructed a quasi-analytical self-consistent model of the stripline-based broadband ferromagnetic resonance (FMR) measurements of ferromagnetic films. Exchange-free description of magnetization dynamics in the films allowed us to obtain simple analytical expressions. They enable quick and efficient numerical simulations of the dynamics. With this model, we studied the contribution of radiation losses to the ferromagnetic resonance linewidth, as measured with the stripline FMR. We found that for films with large conductivity of metals the radiation losses are significantly smaller than for magneto-insulating films. Excitation of microwave eddy currents in these materials contributes to the total microwave impedance of the system. This leads to impedance mismatch with the film environment resulting in decoupling of the film from the environment and, ultimately, to smaller radiation losses. We also show that the radiation losses drop with an increase in the stripline width and when the sample is lifted up from the stripline surface. Hence, in order to eliminate this measurement artefact, one needs to use wide striplines and introduce a spacer between the film and the sample surface. The radiation losses contribution is larger for thicker films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of hydrogen plasma in a microwave plasma chemical vapor deposition reactor

The aim of this work is to build a numerical model of hydrogen plasma inside a microwave plasma chemical vapor deposition system. This model will help in understanding and optimizing the conditions for the growth of carbon nanostructures. A 2D axisymmetric model of the system is implemented using the finite element high frequency Maxwell solver and the heat transfer solver in COMSOL Multiphysics. The system is modeled to study variation in parameters with reactor geometry, microwave power, and gas pressure. The results are compared with experimental measurements from the Q-branch of the H{sub 2} Fulcher band of hydrogen using an optical emission spectroscopy technique. The parameter γ in Füner's model is calibrated to match experimental observations at a power of 500 W and 30 Torr. Good agreement is found between the modeling and experimental results for a wide range of powers and pressures. The gas temperature exhibits a weak dependence on power and a strong dependence on gas pressure. The inclusion of a vertical dielectric pillar that concentrates the plasma increases the maximum electron temperature by 70%, the maximum gas temperature by 50%, and the maximum electron number density by 70% when compared to conditions without the pillar at 500 W and 30 Torr. Experimental observations also indicate intensified plasma with the inclusion of a pillar.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monopole antenna in quantitative near-field microwave microscopy of planar structures

We have developed an analytical model of a near-field microwave microscope based on a coaxial resonator with a sharpened tip probe. The probe interacts with a layered sample that features an arbitrary depth distribution of permittivity. The microscopic tip end with the accumulated charge is regarded as a monopole antenna radiating an electric field in near zone. The impedance of such an antenna is determined within a quasi-static approximation. The proposed model is used for calculating the sample-sensitive parameters of the microscope, specifically, resonance frequency f{sub 0} and quality factor Q{sub 0}, as a function of probe-sample distance h. The theory has been verified experimentally in studies of semiconductor structures, both bulk and thin films. For measurements, we built a ∼2.1 GHz microscope with an effective tip radius of about 100 μm. The theoretical and experimental dependences f{sub 0}(h) and Q{sub 0}(h) were found to be in a good agreement. The developed theory underlies the method for determining sheet resistance R{sub sh} of a semiconductor film on a dielectric substrate proposed in this article. Studies were performed on doped n-GaN films on an Al{sub 2}O{sub 3} substrate. The effective radius and height of the probe determined from calibration measurements of etalon samples were used as the model fitting parameters. For etalon samples, we employed homogeneous sapphire and doped silicon plates. We also performed four-probe dc measurements of R{sub sh}. The corresponding values for samples with R{sub sh} > 1 kΩ were found to be 50% to 100% higher than the microwave results, which are attributed to the presence of microdefects in semiconductor films.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗