Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC FIELD COIL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Effect of island overlap on edge localized mode suppression by resonant magnetic perturbations in DIII-D

Recent DIII-D [J. L. Luxon et al., Nucl. Fusion 43, 1813 (2003)] experiments show a correlation between the extent of overlap of magnetic islands induced in the edge plasma by perturbation coils and complete suppression of Type-I edge localized modes (ELMs) in plasmas with ITER-like electron pedestal collisionality {nu}{sub e}*{approx}0.1, flux surface shape and low edge safety factor (q{sub 95}{approx_equal}3.6). With fixed amplitude n=3 resonant magnetic perturbation (RMP), ELM suppression is obtained only in a finite window in the edge safety factor (q{sub 95}) consistent with maximizing the resonant component of the applied helical field. ELM suppression is obtained over an increasing range of q{sub 95} by either increasing the n=3 RMP strength, or by adding n=1 perturbations to ''fill in'' gaps between islands across the edge plasma. The suppression of Type-I ELMs correlates with a minimum width of the edge region having magnetic islands with Chirikov parameter >1.0, based on vacuum calculations of RMP mode components excluding the plasma response or rotational shielding. The fraction of vacuum magnetic field lines that are lost from the plasma, with connection length to the divertor targets comparable to an electron-ion collisional mean free path, increases throughout the island overlap region in the ELM suppressed case compared with the ELMing case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of physics results from MAST

Several improvements to the MAST plant and diagnostics have facilitated new studies advancing the physics basis for ITER and DEMO, as well as for future spherical tokamaks (STs). Using the increased heating capabilities P-NBI <= 3.8 MW H-mode at I-P = 1.2 MA was accessed showing that the energy confinement on MAST scales more weakly with I-P and more strongly with B-t than in the ITER IPB98(y, 2) scaling. Measurements of the fuel retention of shallow pellets extrapolate to an ITER particle throughput of 70% of its original designed total throughput capacity. The anomalous momentum diffusion, chi(phi), is linked to the ion diffusion, chi(i), with a Prandtl number close to P-phi approximate to chi(phi)/chi(i) approximate to 1, although chi(i) approaches neoclassical values. New high spatial resolution measurements of the edge radial electric field, E-r, show that the position of steepest gradients in electron pressure and E-r (i.e. shearing rate) are coincident, but their magnitudes are not linked. The T-e pedestal width on MAST scales with root beta(ped)(pol) rather than rho(pol). The edge localized mode (ELM) frequency for type-IV ELMs, new in MAST, was almost doubled using n = 2 resonant magnetic perturbations from a set of four external coils (n = 1, 2). A new internal 12 coil set (n <= 3) has been commissioned. The filaments in the inter-ELM and L-mode phase are different from ELM filaments, and the characteristics in L-mode agree well with turbulence calculations. A variety of fast particle driven instabilities were studied from 10 kHz saturated fishbone like activity up to 3.8 MHz compressional Alfven eigenmodes. Fast particle instabilities also affect the off-axis NBI current drive, leading to fast ion diffusion of the order of 0.5 m(2) s(-1) and a reduction in the driven current fraction from 40% to 30%. EBW current drive start-up is demonstrated for the first time in a ST generating plasma currents up to 55 kA. Many of these studies contributed to the physics basis of a planned upgrade to MAST.

Meyer, H.↗

TU-F-CAMPUS-I-04: Head-Only Asymmetric Gradient System Evaluation: ACR Image Quality and Acoustic Noise

Purpose: A high-performance head-only magnetic resonance imaging gradient system with an acquisition volume of 26 cm employing an asymmetric design for the transverse coils has been developed. It is able to reach a magnitude of 85 mT/m at a slew rate of 700 T/m/s, but operated at 80 mT/m and 500 T/m/s for this test. A challenge resulting from this asymmetric design is that the gradient nonlinearly exhibits both odd- and even-ordered terms, and as the full imaging field of view is often used, the nonlinearity is pronounced. The purpose of this work is to show the system can produce clinically useful images after an on-site gradient nonlinearity calibration and correction, and show that acoustic noise levels fall within non-significant risk (NSR) limits for standard clinical pulse sequences. Methods: The head-only gradient system was inserted into a standard 3T wide-bore scanner without acoustic damping. The ACR phantom was scanned in an 8-channel receive-only head coil and the standard American College of Radiology (ACR) MRI quality control (QC) test was performed. Acoustic noise levels were measured for several standard pulse sequences. Results: Images acquired with the head-only gradient system passed all ACR MR image quality tests; Both even and odd-order gradient distortion correction terms were required for the asymmetric gradients to pass. Acoustic noise measurements were within FDA NSR guidelines of 99 dBA (with assumed 20 dBA hearing protection) A-weighted and 140 dB for peak for all but one sequence. Note the gradient system was installed without any shroud or acoustic batting. We expect final system integration to greatly reduce noise experienced by the patient. Conclusion: A high-performance head-only asymmetric gradient system operating at 80 mT/m and 500 T/m/s conforms to FDA acoustic noise limits in all but one case, and passes all the ACR MR image quality control tests. This work was supported in part by the NIH grant 5R01EB010065.

60 APPLIED LIFE SCIENCES↗

An engineering prototype of a late stage ionization cooling cell for a muon collider

Achieving the low emittances necessary for a muon collider requires ionization cooling. Much of that cooling occurs in compact cooling cells where superconducting coils and conventional RF cavities are closely interleaved [1]. The real challenges for these cooling cells reside in their engineering challenges: high field solenoids, RF cavities, and absorbers, often designed near technological limits, placed in close proximity to each other. We thus propose to build a prototype ionization cooling cell to demonstrate the capability of constructing an ionization cooling channel reaching the lowest emittances and to provide engineering input for the design of such beamlines. The magnets and cavities will be powered at their design values, and an absorber will be included along with a mechanism for heating the absorber similarly to how a beam would.

43 PARTICLE ACCELERATORS↗

Stellarator Simplification using Permanent Magnets (PM4Stell)

This Report describes the design and prototyping of an array of rare-Earth permanent magnets to form a stellarator. This effort was motivated by the hypothesis that the usage of permanent magnets, rather than electromagnetic coils with complex geometry, could reduce the cost of stellarator construction and thereby make increase the feasibility of the stellarator as a technology for a fusion-based power plant. In this project, we have developed novel methods for specifying the positions, shapes, and polarizations of the magnets in the array, and have developed designs for mounting structures and tooling for assembly. We have also performed detailed finite-element modeling to qualify the accuracy of the magnetic field produced by the magnet array as designed, and to confirm that the structure can withstand the forces between the magnets. We have also developed techniques for measuring the magnetic field produced by the array once constructed, as well as for correcting errors in the field arising from misalignments and offsets within the tolerances for mounting and fabrication. Finally, we have constructed a tabletop prototype of a section of the array to qualify the concept for assembling and mounting magnets within the array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stellarator Simplification using Permanent Magnets (PM4Stell)

This Report describes the design and prototyping of an array of rare-Earth permanent magnets to form a stellarator. This effort was motivated by the hypothesis that the usage of permanent magnets, rather than electromagnetic coils with complex geometry, could reduce the cost of stellarator construction and thereby make increase the feasibility of the stellarator as a technology for a fusion-based power plant. In this project, we have developed novel methods for specifying the positions, shapes, and polarizations of the magnets in the array, and have developed designs for mounting structures and tooling for assembly. We have also performed detailed finite-element modeling to qualify the accuracy of the magnetic field produced by the magnet array as designed, and to confirm that the structure can withstand the forces between the magnets. We have also developed techniques for measuring the magnetic field produced by the array once constructed, as well as for correcting errors in the field arising from misalignments and offsets within the tolerances for mounting and fabrication. Finally, we have constructed a tabletop prototype of a section of the array to qualify the concept for assembling and mounting magnets within the array.

47 OTHER INSTRUMENTATION↗

Co-Registration of MEG and ULF MRI using a 7 channel low-Tc SQUID system

In human brain imaging, e.g. pre-surgical mapping, it is highly desired to obtain images with high spatial and temporal resolution. However, no single imaging device is capable of producing both a high spatial resolution anatomical image and a high temporal resolution functional image. During the last couple of years significant efforts have been directed towards magnetic resonance imaging (MRI) in fields comparable to the Earth's field, i.e. microtesla fields, or lower fields. The fields in this range are called ultra-low fields (ULF). Interestingly, the idea of magnetic resonance at microtesla fields is more than 50 years old. In ULF MR it is essential to use pre-polarization to increase the signal-to-noise ratio of the signal from the precessing spins, since the magnetization from the measurement field alone is very small. Even with the present level of prepolarization the ULF images are not as highly resolved as their high-field counterparts. By using a 7 channel system equipped with low transition temperature (T{sub c}) Superconducting QUantum Interference Devices (SQUIDs) to perform both ULF MRI and magnetoencephalography (MEG), it is possible to coregister a lower resolution ULF MR image and an MEG image obtained during one run. Thereby, the MEG data is aligned to the ULF MR image after performing a calibration run with a phantom. The ULF MR image can then be used to align the MEG data onto a high-field MR image. Recently, our group presented the first brain images obtained by ULF MRI. The MR imaging was combined with an MEG session performed a posteriori. The subject's head was moved in between the MRI run and the MEG run and no reference coils were used to quantify the translation. The main reason for the translation of the head was to improve the coverage of the auditory evoked response. In this paper, we report interleaved ULF MRI and MEG measurements co-registered in the same system.

42 ENGINEERING↗

Cost-effective Conductor, Cable, and Coils for High Field Rotating Electric Machines

The purpose of the DOE-AMMTO-funded project was to significantly reduce industrial energy intensity through manufacturing innovations. The project focused on superconducting technology for industrial motors to dramatically increase efficiency. The bottleneck in deploying high temperature superconducting (HTS) motors was high cost and low yield of the conductor manufacturing process. The process yield is low because of the defects in the conductor, forcing the manufacturers to cut off defective sections after characterizing each millimeter. Additionally, the piece lengths tend to be low because of the defects. The project tackled the low-yield manufacturing process challenge by devising an innovative method to use defective conductors in bundled cables without losing performance by engineering current sharing among the conductors. The innovation not only lowers the cost of the conductor but also enhances the reliability of HTS motors and other devices to mitigate the defects that might form during the fabrication and operation of the device. With the increasing interest in REBa2Cu3O7-x (REBCO)-coated conductors for various power, energy, and magnet applications, ensuring the reliability of HTS devices is of significant interest. The EERE funding allowed us to make significant progress in understanding the defects in manufactured conductors and the implications of the defects in superconducting electric motors and other superconducting power and energy applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High resolution neutron Larmor diffraction using superconducting magnetic Wollaston prisms

The neutron Larmor diffraction technique has been implemented using superconducting magnetic Wollaston prisms in both single-arm and double-arm configurations. Successful measurements of the coefficient of thermal expansion of a single-crystal copper sample demonstrates that the method works as expected. Our experiment involves a new method of tuning by varying the magnetic field configurations in the device and the tuning results agree well with previous measurements. The difference between single-arm and double-arm configurations has been investigated experimentally. Here, we conclude that this measurement benchmarks the applications of magnetic Wollaston prisms in Larmor diffraction and shows in principle that the setup can be used for inelastic phonon line-width measurements. The achievable resolution for Larmor diffraction is comparable to that using Neutron Resonance Spin Echo (NRSE) coils. Furthermore, the use of superconducting materials in the prisms allows high neutron polarization and transmission efficiency to be achieved.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First measurements of error fields on W7-X using flux surface mapping

Error fields have been detected and quantified using the flux surface mapping diagnostic system on Wendelstein 7-X (W7-X). A low-field '${\rlap{-}\ \iota} =1/2$ ' magnetic configuration (${\rlap{-}\ \iota} =\iota /2\pi $ ), sensitive to error fields, was developed in order to detect their presence using the flux surface mapping diagnostic. In this configuration, a vacuum flux surface with rotational transform of n/m = 1/2 is created at the mid-radius of the vacuum flux surfaces. If no error fields are present a vanishingly small n/m = 5/10 island chain should be present. Modeling indicates that if an n = 1 perturbing field is applied by the trim coils, a large n/m = 1/2 island chain will be opened. This island chain is used to create a perturbation large enough to be imaged by the diagnostic. Phase and amplitude scans of the applied field allow the measurement of a small $\sim 0.04$ m intrinsic island chain with a ${{130}^{\circ}}$ phase relative to the first module of the W7-X experiment. Lastly, these error fields are determined to be small and easily correctable by the trim coil system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neoclassical toroidal viscosity torque prediction via deep learning

GPECnet is a densely connected neural network that has been trained on GPEC data, to predict the plasma stability, neoclassical toroidal viscosity (NTV) torque, and optimized 3D coil current distributions for desired NTV torque profiles. Using NTV torque, driven by non-axisymmetric field perturbations in a tokamak, can be vital in optimizing pedestal performance by controlling the rotation profile in both the core, to ensure tearing stability, and the edge, to avoid edge localized modes (ELMs). The generalized perturbed equilibrium code (GPEC) software package can be used to calculate the plasma stability to 3D perturbations and the NTV torque profile generated by applied 3D magnetic fields. These calculations, however, involve complex integrations over space and energy distributions, which takes time to compute. Initially, GPECnet has been trained solely on data representative of the quiescent H-mode (QH) scenario, in which neutral beams are often balanced and toroidal rotation is low across the plasma profile. Lastly, this work provides the foundation for active control of the rotation shear using a combination of beams and 3D fields for robust and high performance QH mode operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear optics compensation for the HEX superconducting wiggler at NSLS-II

At the NSLS-II ring, a 1.2 m long superconducting wiggler with the maximum 4.34T magnetic field has been installed at a low-β straight section (cell 27) to drive the high energy engineering X-ray scattering (HEX) beamline. To mitigate the potential performance degradation due to the linear optics distortion, a local compensation scheme was adopted and confirmed with the online beam measurement. A feedforward control to enable a dynamic compensation of the linear optics distortion was deployed. It can maintain the storage ring lattice performance when the device main coil current ramps.

36 MATERIALS SCIENCE↗

Inter and Intra Molecular Phase Separation Environment Effects on PI-PEO Block Copolymers for Batteries and Fuel Cells

Rod-coil molecules have been introduced as a novel type of block copolymers with unique microstructure due to their ability to self-assemble to various ordered morphologies on a nanometer length scale. These molecules, comprised two homo polymers joined together at one end, microphase separate into ordered, periodic arrays of spheres, cylinders in the bulk state and or solution. To get ordered structure in a reasonable scale, additional force field are applied, such as mechanical shearing, electric field and magnetic field. Recently, progress has made it a possible to develop a new class of polyimides (PI)-Polyethylene oxide (PEO) that are soluble in polar organic solvents. The solvent-soluble PI-PEO has a wide variety of applications in microelectronics, since these PI-PEO films exhibit a high degree of thermal and chemical stability. In this paper, we report the self-assembled ordered structure of PI-PEO molecules formed from concentrate solution.

Xue, Chen-Chen↗

SolCalc: A Suite for the Calculation and the Display of Magnetic Fields Generated by Solenoid Systems

SolCalc is a software suite that computes and displays magnetic fields generated by a three dimensional (3D) solenoid system. Examples of such systems are the Mu2e magnet system and Helical Solenoids for muon cooling systems. SolCalc was originally coded in Matlab, and later upgraded to a compiled version (called MEX) to improve solving speed. Matlab was chosen because its graphical capabilities represent an attractive feature over other computer languages. Solenoid geometries can be created using any text editor or spread sheets and can be displayed dynamically in 3D. Fields are computed from any given list of coordinates. The field distribution on the surfaces of the coils can be displayed as well. SolCalc was benchmarked against a well-known commercial software for speed and accuracy and the results compared favorably.

43 PARTICLE ACCELERATORS↗

Non-disruptive error field measurement in DIII-D low safety factor plasmas and projection to ITER

Previous experiments in DIII-D (Paz-Soldan et al 2022 Nucl. Fusion 62 126007) introduced a method to identify intrinsic error fields (EFs) in tokamaks with minimal disruption risk by promptly healing driven magnetic islands during the conventional 'compass scan'. This paper presents recent experimental and numerical advancements in extending this approach to low q 95 plasmas, and projects its applicability to ITER. Non-disruptive EF measurement is achieved at q 95 = 4.5 and 3.9 without any initial EF correction (EFC) by reducing the time between the occurrence of the locked mode (LM) and control action to 10 ms and increasing the density 50%–100%. However, 50% correction of the intrinsic EF is required to achieve island healing at q 95 = 3.2 with 10 ms delay for the control action. Nonlinear two-fluid modeling with the TM1 code reproduces the DIII-D experimental observations, indicating that promptly turning off the 3D coil current reduces both magnetic island width and electromagnetic force, while raising the density increases plasma viscosity, facilitating magnetic island healing. The simulations show that for scenarios with q 95 = 3.2, lowering the control action time to 5 ms will lead to island healing without EFC. TM1 simulations are extended to future ITER scenarios with 5 MA and 7.5 MA plasma currents, predicting the dependence of required density rise on action time and EF amplitude. These simulations indicate that, benefiting from the much longer resistive time, island healing can be successfully achieved in ITER when taking control action 100–500 ms after a LM occurrence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a new virtual diagnostic for V3FIT

The determination of plasma equilibria from diagnostic information is a fundamental issue. V3FIT is a fully three-dimensional reconstruction code capable of solving the inverse problem using both magnetic and kinetic measurements. It uses VMEC as core equilibrium solver and supports both free- and fixed-boundary reconstruction approaches. In fixed-boundary mode VMEC does not use explicit information about currents in external coils, even though it has important effects on the shape of the safety factor profile. Indeed, the edge safety factor influences the reversal position in RFP plasmas, which then determines the position of the m = 0 island chain and the edge transport properties. In order to exploit such information a new virtual diagnostic has been developed, that thanks to Ampère's law relates the external current through the center of the torus to the circulation of the toroidal magnetic field on the outermost flux surface. The reconstructions that exploit the new diagnostic are indeed found to better interpret the experimental data with respect to edge physics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Systematic parameter study of a nonlinear electromagnetic energy harvester with matched magnetic orientation: Numerical simulation and experimental investigation

Here, this paper reports the systematic parameter study of a tristable nonlinear electromagnetic energy harvester for ambient low-frequency vibration. Numerical simulations and experimental investigations are performed on the harvester which consists of a cantilever beam, a tip coil, two tip magnets and two external side magnets. The external side magnets are deployed symmetrically along a concave surface parallel to the trajectory of the cantilever tip with a controllable distance so that the magnetic orientation of the tip magnets are matched with that of the side magnets. Therefore, instead of the ternary position parameters (d, h, α), a binary parameters pair (d 0 , d) is used to characterize the position of the side magnets and the performance of the energy harvester. The magnetic force and magnetic field on the cantilever tip therefore depend on the relative distance in the tip displacement direction between the tip magnets and side magnets, but is independent of the position of the side magnets on the concave surface. The magnetic force (field)-distance relationship is measured experimentally and curve fitted to obtain explicit expressions, in order to characterize the magnetic force (field) when the side magnets are placed at varied positions along the concave surface. Numerical simulation is, then, performed to predict the electromagnetic voltage output and the bandwidth of the energy harvester. The simulation results coincided with the measured data. Significant broadband response is obtained experimentally and the maximum RMS power output is 40.2 mW at 0.45 g of excitation. Furthermore, the proposed structure showcasing the matched magnetic orientation is characterized by the binary parameters pair (d 0 , d) and the systematic parametric approach could contribute to the design and study of nonlinear broadband energy harvesters.

30 DIRECT ENERGY CONVERSION↗

Magnet Coil Designs Using YBCO High Temperature Superconductor

Magnet coils built with the superconducting “cos θ” technology have proven extraordinarily popular, cost effective and reliable in modern particle accelerators. The term “cos θ” describes a coil design in which current conductors are placed on the surface of a cylindrical tube with more turns near the mid-plane and less near the pole proportional to the cosine of the angle measured from the mid-plane. Once this challenging technology is mastered, the design offers many options regarding cost, field intensity and quality, size of aperture, and multipole fields that are important to accelerator designers and builders for bending and controlling beam particles.

Gupta, Ramesh↗