Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

The simulation of 3D microcalcification clusters in 2D digital mammography and breast tomosynthesis

Purpose: This work proposes a new method of building 3D models of microcalcification clusters and describes the validation of their realistic appearance when simulated into 2D digital mammograms and into breast tomosynthesis images. Methods: A micro-CT unit was used to scan 23 breast biopsy specimens of microcalcification clusters with malignant and benign characteristics and their 3D reconstructed datasets were segmented to obtain 3D models of microcalcification clusters. These models were then adjusted for the x-ray spectrum used and for the system resolution and simulated into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. Six radiologists were asked to distinguish between 40 real and 40 simulated clusters of microcalcifications in two separate studies on 2D mammography and tomosynthesis datasets. Receiver operating characteristic (ROC) analysis was used to test the ability of each observer to distinguish between simulated and real microcalcification clusters. The kappa statistic was applied to assess how often the individual simulated and real microcalcification clusters had received similar scores (''agreement'') on their realistic appearance in both modalities. This analysis was performed for all readers and for the real and the simulated group of microcalcification clusters separately. ''Poor'' agreement would reflect radiologists' confusion between simulated and real clusters, i.e., lesions not systematically evaluated in both modalities as either simulated or real, and would therefore be interpreted as a success of the present models. Results: The area under the ROC curve, averaged over the observers, was 0.55 (95% confidence interval [0.44, 0.66]) for the 2D study, and 0.46 (95% confidence interval [0.29, 0.64]) for the tomosynthesis study, indicating no statistically significant difference between real and simulated lesions (p > 0.05). Agreement between allocated lesion scores for 2D mammography and those for the tomosynthesis series was poor. Conclusions: The realistic appearance of the 3D models of microcalcification clusters, whether malignant or benign clusters, was confirmed for 2D digital mammography images and the breast tomosynthesis datasets; this database of clusters is suitable for use in future observer performance studies related to the detectability of microcalcification clusters. Such studies include comparing 2D digital mammography to breast tomosynthesis and comparing different reconstruction algorithms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

HIGH-CONTRAST IMAGING VIA MODAL CONVERGENCE OF DEFORMABLE MIRROR

For extremely high contrast imaging, such as direct observation of faint stellar companions, an adaptive optics system is required to produce low-halo and low-speckle regions in the focal plane. A method for deformable mirror control is proposed to achieve this goal. The method relies on a modal convergence of the deformable mirror driven by a focal-plane metric. The modal sets are derived from the Walsh functions. The Walsh-function modes serve two purposes: the expansion of the actuator displacements and the expansion of the phase functions. Taking advantage of the unique properties of the modal functions, a universal control algorithm is devised for the realization of high-contrast focal planes with and without the help of conventional coronagraphy. Numerical modeling is conducted to simulate complete imaging systems under various scenarios. It is shown that the proposed method reliably produces high-contrast focal planes using either a segmented or a membrane mirror. In the presence of random aberration the method is shown to be able to maintain high-contrast focal planes. Requiring neither retrieval of electric fields nor detailed knowledge of the deformable mirrors, this technique may allow high-contrast imaging in real time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Biological Image-Guided Radiotherapy in Rectal Cancer: Challenges and Pitfalls

Purpose: To investigate the feasibility of integrating multiple imaging modalities for image-guided radiotherapy in rectal cancer. Patients and Methods: Magnetic resonance imaging (MRI) and fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) were performed before, during, and after preoperative chemoradiotherapy (CRT) in patients with resectable rectal cancer. The FDG-PET signals were segmented with an adaptive threshold-based and a gradient-based method. Magnetic resonance tumor volumes (TVs) were manually delineated. A nonrigid registration algorithm was applied to register the images, and mismatch analyses were carried out between MR and FDG-PET TVs and between TVs over time. Tumor volumes delineated on the images after CRT were compared with the pathologic TV. Results: Forty-five FDG-PET/CT and 45 MR images were analyzed from 15 patients. The mean MRI and FDG-PET TVs showed a tendency to shrink during and after CRT. In general, MRI showed larger TVs than FDG-PET. There was an approximately 50% mismatch between the FDG-PET TV and the MRI TV at baseline and during CRT. Sixty-one percent of the FDG-PET TV and 76% of the MRI TV obtained after 10 fractions of CRT remained inside the corresponding baseline TV. On MRI, residual tumor was still suspected in all 6 patients with a pathologic complete response, whereas FDG-PET showed a metabolic complete response in 3 of them. The FDG-PET TVs delineated with the gradient-based method matched closest with pathologic findings. Conclusions: Integration of MRI and FDG-PET into radiotherapy seems feasible. Gradient-based segmentation is recommended for FDG-PET. Spatial variance between MRI and FDG-PET TVs should be taken into account for target definition.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A high-speed lossless data compression system for space applications

This paper reports on the integration of a lossless data compression/decompression chipset into a space data system architecture. For its compression engine, the data system incorporates the Universal Source Encoder (USE) designed for the NASA/Goddard Space Flight Center. Currently, the data compression testbed generates video frames consisting of 512 lines of 512 pixels having 8-bit resolution. Each image is passed through the USE where the lines are internally partitioned into 16-word blocks. These blocks are adaptively encoded across widely varying entropy levels using a Rice 12-option set coding algorithm. The current system operates at an Input/Output rate of 10 Msamples/s or 80 Mbits/s for each buffered input line. Frame and line synchronization for each image are maintained through the use of uniquely decodable command words. Length information of each variable length compressed image line is also included in the output stream. The data and command information are passed to the next stage of the system architecture through a serial fiber-optic transmitter. The initial segment of this stage consists of packetizer hardware which adds an appropriate CCSDS header to the received source data. An uncompressed mode is optionally available to pass image lines directly to the packetizer hardware. A data decompression testbed has also been developed to confirm the data compression operation.

Miko, Joe↗

Predicting the detectability of thin gaseous plumes in hyperspectral images using basis vectors

This paper describes a new method for predicting the detectability of thin gaseous plumes in hyperspectral images. The novelty of this method is the use of basis vectors for each of the spectral channels of a collection instrument to calculate noise-equivalent concentration-pathlengths instead of matching scene pixels to absorbance spectra of gases in a library. This method provides insight into regions of the spectrum where gas detection will be relatively easier or harder, as influenced by ground emissivity, temperature contrast, and the atmosphere. We relate a three-layer physics-based radiance model to basis vector noise-equivalent concentration-pathlengths, to signal-to-noise ratios, and finally to minimum detectable concentration-pathlengths. We illustrate the method using an Airborne Hyperspectral Imager image. Our results show that data collection planning could be in°uenced by information about when potential plumes are likely to be over background segments that are most conducive to detection.

54 ENVIRONMENTAL SCIENCES↗

MO-F-CAMPUS-J-05: Toward MRI-Only Radiotherapy: Novel Tissue Segmentation and Pseudo-CT Generation Techniques Based On T1 MRI Sequences

Purpose: To develop and validate a 4 class tissue segmentation approach (air cavities, background, bone and soft-tissue) on T1 -weighted brain MRI and to create a pseudo-CT for MRI-only radiation therapy verification. Methods: Contrast-enhanced T1-weighted fast-spin-echo sequences (TR = 756ms, TE= 7.152ms), acquired on a 1.5T GE MRI-Simulator, are used.MRIs are firstly pre-processed to correct for non uniformity using the non parametric, non uniformity intensity normalization algorithm. Subsequently, a logarithmic inverse scaling log(1/image) is applied, prior to segmentation, to better differentiate bone and air from soft-tissues. Finally, the following method is enrolled to classify intensities into air cavities, background, bone and soft-tissue:Thresholded region growing with seed points in image corners is applied to get a mask of Air+Bone+Background. The background is, afterward, separated by the scan-line filling algorithm. The air mask is extracted by morphological opening followed by a post-processing based on knowledge about air regions geometry. The remaining rough bone pre-segmentation is refined by applying 3D geodesic active contours; bone segmentation evolves by the sum of internal forces from contour geometry and external force derived from image gradient magnitude.Pseudo-CT is obtained by assigning −1000HU to air and background voxels, performing linear mapping of soft-tissue MR intensities in [-400HU, 200HU] and inverse linear mapping of bone MR intensities in [200HU, 1000HU]. Results: Three brain patients having registered MRI and CT are used for validation. CT intensities classification into 4 classes is performed by thresholding. Dice and misclassification errors are quantified. Correct classifications for soft-tissue, bone, and air are respectively 89.67%, 77.8%, and 64.5%. Dice indices are acceptable for bone (0.74) and soft-tissue (0.91) but low for air regions (0.48). Pseudo-CT produces DRRs with acceptable clinical visual agreement to CT-based DRR. Conclusion: The proposed approach makes it possible to use T1-weighted MRI to generate accurate pseudo-CT from 4-class segmentation.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-06: BEST IN PHYSICS (JOINT IMAGING-THERAPY): An MRI Compatible Externally and Internally Deformable Lung Motion Phantom for Multi-Modality IGRT

Purpose: MRI has become an attractive tool for tumor motion management. Current MR-compatible phantoms are only capable of reproducing translational motion. This study describes the construction and validation of a more realistic, MRI-compatible lung phantom that is deformable internally as well as externally. We demonstrate a radiotherapy application of this phantom by validating the geometric accuracy of the open-source deformable image registration software NiftyReg (UCL, UK). Methods: The outer shell of a commercially-available dynamic breathing torso phantom was filled with natural latex foam with eleven water tubes. A rigid foam cut-out served as the diaphragm. A high-precision programmable, in-house, MRI-compatible motion platform was used to drive the diaphragm. The phantom was imaged on a 3T scanner (Philips, Ingenia). Twenty seven tumor traces previously recorded from lung cancer patients were programmed into the phantom and 2D+t image sequences were acquired using a sparse-sampling sequence k-t BLAST (accn=3, resolution=0.66×0.66×5mm3; acquisition-time=110ms/slice). The geometric fidelity of the MRI-derived trajectories was validated against those obtained via fluoroscopy using the on board kV imager on a Truebeam linac. NiftyReg was used to perform frame by frame deformable image registration. The location of each marker predicted by using NiftyReg was compared with the values calculated by intensity-based segmentation on each frame. Results: In all cases, MR trajectories were within 1 mm of corresponding fluoroscopy trajectories. RMSE between centroid positions obtained from segmentation with those obtained by NiftyReg varies from 0.1 to 0.21 mm in the SI direction and 0.08 to 0.13 mm in the LR direction showing the high accuracy of deformable registration. Conclusion: We have successfully designed and demonstrated a phantom that can accurately reproduce deformable motion under a variety of imaging modalities including MRI, CT and x-ray fluodoscopy, making it an invaluable research tool for validating novel motion management strategies. This work was partially supported through research funding from National Institutes of Health (R01CA169102).

60 APPLIED LIFE SCIENCES↗

Leveraging Resonant Terminator Orbits for the Trajectory Design of OSIRIS-APEX at (99942) Apophis

The OSIRIS-REx spacecraft has been approved for an extended mission (OSIRIS-APEX) to visit the asteroid (99942) Apophis. In this paper we outline a potential design for the spacecraft’s trajectory during the variable phase orbit segment of the APEX mission. This phase of the mission, nominally expected to begin in January2030, has the primary goal of collecting image and spectral data of the full asteroid surface at a wide variety of illumination conditions without requiring frequent firing of the spacecraft thrusters. This work will focus on leveraging resonant terminator orbits (RTOs) in order to satisfy these goals and the associated science requirements. Though this segment will occur after Apophis’ closest flyby of Earth in April 2029, the proposed design utilizes the current best estimates of the asteroid’s orbital elements and physical properties at that time when designing the spacecraft’s orbit.

Gavin M Brown↗

Toward Real-Time Analysis of Synchrotron Micro-Tomography Data: Accelerating Experimental Workflows with AI and HPC

ynchrotron light sources are routinely used to perform imaging experiments. In this paper, we review the relevant computational stages, identify bottlenecks, and highlight future opportunities to streamline data acquisition for experimental microscopy workflows. We demonstrate our preliminary exploration with an end-to-end scientific workflow on Summit based on micro-computed tomography data. Computational elements include: 1) reconstruction of volumetric image data; 2) denoising with deep neural networks; and 3) non-local means based segmentation and quantitative analysis.

Mcclure, James↗

Spinal Cord Tolerance to Single-Fraction Partial-Volume Irradiation: A Swine Model

Purpose: To determine the spinal cord tolerance to single-fraction, partial-volume irradiation in swine. Methods and Materials: A 5-cm-long cervical segment was irradiated in 38-47-week-old Yucatan minipigs using a dedicated, image-guided radiosurgery linear accelerator. The radiation was delivered to a cylindrical volume approximately 5 cm in length and 2 cm in diameter that was positioned lateral to the cervical spinal cord, resulting in a dose distribution with the 90%, 50%, and 10% isodose lines traversing the ipsilateral, central, and contralateral spinal cord, respectively. The dose was prescribed to the 90% isodose line. A total of 26 pigs were stratified into eight dose groups of 12-47 Gy. The mean maximum spinal cord dose was 16.9 {+-} 0.1, 18.9 {+-} 0.1, 21.0 {+-} 0.1, 23.0 {+-} 0.2, and 25.3 {+-} 0.3 Gy in the 16-, 18-, 20-, 22-, and 24-Gy dose groups, respectively. The mean percentage of spinal cord volumes receiving {>=}10 Gy for the same groups were 43% {+-} 3%, 48% {+-} 4%, 51% {+-} 2%, 57% {+-} 2%, and 59% {+-} 4%. The study endpoint was motor neurologic deficit determined by a change in gait during a 1-year follow-up period. Results: A steep dose-response curve was observed with a median effective dose for the maximum dose point of 20.0 Gy (95% confidence interval, 18.3-21.7). Excellent agreement was observed between the occurrence of neurologic change and the presence of histologic change. All the minipigs with motor deficits showed some degree of demyelination and focal white matter necrosis on the irradiated side, with relative sparing of the gray matter. The histologic findings were unremarkable in the minipigs with normal neurologic status. Conclusions: Our results have indicated that for a dose distribution with a steep lateral gradient, the pigs had a lower median effective dose for paralysis than has been observed in rats and more closely resembles that for rats, mice, and guinea pigs receiving uniform spinal cord irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Controlling azimuthal spoke modes in a cylindrical Hall thruster using a segmented anode

Azimuthal spoke-like modes commonly occur in E × B discharges. The natural occurrence of the spoke mode is correlated with changes of plasma parameters. Here in this paper, instead of allowing these changes to occur naturally, we report a technique for actively controlling the spoke by adjusting the boundary condition at the anode. The technique is demonstrated using a cylindrical Hall thruster equipped with a segmented anode. By varying the voltage and the relative phases of the anode segments, properties of the azimuthal mode can be altered substantially, as shown by fast camera images and probe diagnostics. This technique may be extended to other Hall discharges in order to either induce or suppress azimuthal activities, and thereby controlling the operation and the performance of the devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electronic Scanning Strategies in Adaptive Electrical Capacitance Volume Tomography: Tradeoffs and Prospects

Electrical Capacitance Volume Tomography (ECVT) has been applied for imaging of multiphase flows found in industrial applications. The ill-posed nature of the image reconstruction problem in ECVT and the consequent low resolution can be alleviated by employing electronic scanning enabled by electrode segmentation and reconfiguration during data acquisition. Here we study electronic scanning strategies that mimic physical rotation and shifting of the sensor along its symmetry axis. First, we study the feasibility of electronic scanning by analyzing the capacitance transducer circuit in SPICE. Then, we simulate electronic scanning using the finite element method for different electrode shapes, for which we compare the image reconstruction results and acquisition time. We find a noticeable improvement in image resolution for the scanning cases over conventional ECVT. Lastly, among the scanning cases, we emphasize a particular electrode shape that provides the best image resolution along with the minimal amount of acquisition time.

47 OTHER INSTRUMENTATION↗

Experimental investigation of the response of an a-Si EPID to an unflattened photon beam from an Elekta Precise linear accelerator

The characteristics of an Elekta amorphous silicon (a-Si) electronic portal imaging device (EPID) in response to a 6 MV photon beam generated without a flattening filter, an unflattened beam, have been determined. The characteristics were then compared to those for a conventional photon beam generated with a flattening filter in the beam, a flattened beam, in order to determine the suitability of an a-Si EPID for transit dosimetry. The response of the EPID to the unflattened beam increased by 7.3% compared to the flattened beam, and copper buildup of 3 mm reduces the variation in the EPID response over air gaps ranging from 60 to 40 cm to within 2.5%. The scattering properties of the EPID with changing field size for the unflattened beam agree with those measured for a flattened beam to within 2%. Due to the minimal variation in the energy spectrum of the unflattened beam with the distance from the central axis, it was expected and experimentally found that the profile shape of the unflattened beam changes minimally with increasing phantom thickness. For an unflattened beam, EPID measured profiles with and without a phantom in the beam agree to within 2% using confidence limits. The difference between EPID and ionization chamber profiles measured at a depth of 5 cm in water is reduced compared to a flattened beam and remains unchanged with increasing phantom thickness. A difference of 4% was found between EPID profiles and the corresponding profiles measured with an ionization chamber measured in water over a range of phantom thickness. A calibration procedure was developed to convert EPID images to the equivalent absolute dose in water, at the EPID plane. A gamma evaluation was performed comparing the calibrated EPID images to dose measured with an ionization chamber array for rectangular fields and an IMRT segment. The fields were situated on axis and at 5 cm off axis with and without a 25 cm thick phantom in the beam. The gamma evaluation criteria of 3% and 3 mm were met within the field, for all fields examined. This study concludes that a-Si EPIDs are suitable dosimeters for IMRT treatments using unflattened photon beams with the advantage that the characteristics of the unflattened beam result in a reduction in the number of measurements necessary to calibrate an a-Si EPID as a transit dosimeter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-E-BRF-08: Subpopulations of Similarly-Responding Lesions in Metastatic Prostate Cancer

Purpose: In patients with multiple lesions, resistance to cancer treatments and subsequent disease recurrence may be due to heterogeneity of response across lesions. This study aims to identify subpopulations of similarly-responding metastatic prostate cancer lesions in bone using quantitative PET metrics. Methods: Seven metastatic prostate cancer patients treated with AR-directed therapy received pre-treatment and mid-treatment [F-18]NaF PET/CT scans. Images were registered using an articulated CT registration algorithm and transformations were applied to PET segmentations. Midtreatment response was calculated on PET-based texture features. Hierarchical agglomerative clustering was used to form groups of similarly-responding lesions, with the number of natural clusters (K) determined by the inconsistency coefficient. Lesion clustering was performed within each patient, and for the pooled population. The cophenetic coefficient (C) quantified how well the data was clustered. The Jaccard Index (JI) assessed similarity of cluster assignments from patient clustering and from population clustering. Results: 188 lesions in seven patients were identified for analysis (between 6 to 53 lesions per patient). Lesion response was defined as percent change relative to pre-treatment for 23 uncorrelated PET-based feature identifiers. . High response heterogeneity was found across all lesions (i.e. range ΔSUVmax =−95.98% to 775.00%). For intra-patient clustering, K ranged from 1–20. Population-based clustering resulted in 75 clusters, of 1-6 lesions each. Intra-patient clustering resulted in higher quality clusters than population clustering (mean C=0.95, range=0.89 to 1.00). For all patients, cluster assignments from population clustering showed good agreement to intra-patient clustering (mean JI=0.87, range=0.68 to 1.00). Conclusion: Subpopulations of similarly-responding lesions were identified in patients with multiple metastatic lesions. Good agreement was found between population- and patient-level clustering, indicating that PET-based response features may be used to quantify disease heterogeneity in advanced metastatic disease. This method for categorizing lesion response could help in identifying lesions with similar phenotypic- or genetic-based resistances to therapy. Research Supported by the Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

Technical Note: A fast online adaptive replanning method for VMAT using flattening filter free beams

Purpose: To develop a fast replanning algorithm based on segment aperture morphing (SAM) for online replanning of volumetric modulated arc therapy (VMAT) with flattening filter free (FFF) beams. Methods: A software tool was developed to interface with a VMAT research planning system, which enables the input and output of beam and machine parameters of VMAT plans. The SAM algorithm was used to modify multileaf collimator positions for each segment aperture based on the changes of the target from the planning (CT/MR) to daily image [CT/CBCT/magnetic resonance imaging (MRI)]. The leaf travel distance was controlled for large shifts to prevent the increase of VMAT delivery time. The SAM algorithm was tested for 11 patient cases including prostate, pancreatic, and lung cancers. For each daily image set, three types of VMAT plans, image-guided radiation therapy (IGRT) repositioning, SAM adaptive, and full-scope reoptimization plans, were generated and compared. Results: The SAM adaptive plans were found to have improved the plan quality in target and/or critical organs when compared to the IGRT repositioning plans and were comparable to the reoptimization plans based on the data of planning target volume (PTV)-V100 (volume covered by 100% of prescription dose). For the cases studied, the average PTV-V100 was 98.85% ± 1.13%, 97.61% ± 1.45%, and 92.84% ± 1.61% with FFF beams for the reoptimization, SAM adaptive, and repositioning plans, respectively. The execution of the SAM algorithm takes less than 10 s using 16-CPU (2.6 GHz dual core) hardware. Conclusions: The SAM algorithm can generate adaptive VMAT plans using FFF beams with comparable plan qualities as those from the full-scope reoptimization plans based on daily CT/CBCT/MRI and can be used for online replanning to address interfractional variations.

60 APPLIED LIFE SCIENCES↗

LANDSAT-D accelerated payload correction subsystem output computer compatible tape format

The NASA GSFC LANDSAT-D Ground Segment (GS) is developing an Accelerated Payload Correction Subsystem (APCS) to provide Thematic Mapper (TM) image correction data to be used outside the GS. This correction data is computed from a subset of the TM Payload Correction Data (PCD), which is downlinked from the spacecraft in a 32 Kbps data stream, and mirror scan correction data (MSCD), which is extracted from the wideband video data. This correction data is generated in the GS Thematic Mapper Mission Management Facility (MMF-T), and is recorded on a 9-track 1600 bit per inch computer compatible tape (CCT). This CCT is known as a APCS Output CCT (AOT). The AOT follows standardized corrections with respect to data formats, record construction and record identification. Applicable documents are delineated; common conventions which are used in further defining the structure, format and content of the AOT are defined; and the structure and content of the AOT are described.

Source record↗

LANDSAT-D Mission System Industry Briefing

Viewgraphs and photographs depict the scope and purpose of the LANDSAT 4 mission as well as all satellite systems. The components and major functions of the flight and ground segments, operational support, communication links, and the hardware and interfaces for processing MSS and TM images are covered.

Source record↗

Algorithms For Segmentation Of Complex-Amplitude SAR Data

Several algorithms implement improved method of segmenting highly speckled, high-resolution, complex-amplitude synthetic-aperture-radar (SAR) digitized images into regions, within each backscattering characteristics similar or homogeneous from place to place. Method provides for approximate, deterministic solution by two alternative algorithms almost always converging to local minimums: one, Iterative Conditional Modes (ICM) algorithm, which locally maximizes posterior probability density of region labels; other, Maximum Posterior Marginal (MPM) algorithm, which maximizes posterior marginal density of region labels at each pixel location. ICM algorithm optimizes reconstruction of underlying scene. MPM algorithm minimizes expected number of misclassified pixels, possibly better in remote sensing of natural scenes.

Rignot, Eric J. M.↗