Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Combined effect of injected interstitials and He implantation, and cavities inside dislocation loops in high purity Fe-Cr alloys

High purity Fe-Cr alloys with Cr content ranging from 3 to 14 wt% were irradiated by self-ions at 500 °C in dual-beam mode up to 157 displacements per atom (dpa), 17 appm He/dpa. Transmission electron microscopy (TEM) on focused ion beam foils revealed the depth distribution of irradiation induced cavities and dislocation loops. A detailed quantitative analysis of cavity microstructure was performed on Fe14%Cr, while Fe(3, 5, 10, 12)%Cr were analyzed qualitatively. A homogeneous distribution of small cavities were observed up to the damage peak. From surface to the damage peak, cavity number density increased almost linearly. The cavity microstructure changed drastically at and after the damage peak, where the size increased and number density decreased. Most notably, the microstructure consisted of a striking mixture of heterogeneously nucleated cavities inside dislocation loops and freely nucleated cavities in the matrix. Further, the depth-dependent void swelling increased continuously along the damage depth. This contrasts with most ion irradiation results where suppression of void swelling occurs adjacent to the damage peak due the injected interstitial effect. We hypothesize a plausible mechanism of the observed swelling variation based on a combined effect of the injected interstitials and helium implantation near the damage peak by comparing the results with those in pure iron irradiated under same conditions. This synergistic effect may develop cavity microstructures which do not necessarily reflect microstructures expected due to injected interstitial effect and can be easily wrongly interpreted. The depth dependent dislocation loop microstructure was studied qualitatively in Fe14%Cr sample. Up to the damage peak, a complex dense network of dislocations formed due to the interaction/impingement of the dislocation loops. Individually resolvable loops were only observed after the damage peak, where their association with cavities was noted. Furthermore helium also induced heterogeneous cavity nucleation on dislocations constituting a grain boundary and on pre-existing dislocation lines.

36 MATERIALS SCIENCE↗

In Vivo Model to Test Implanted Biosensors for Blood pH

Biosensors for monitoring physiologic data continuously through telemetry are available for heart rate, respiration, and temperature but not for blood pH or ions affected by hydrogen ion concentration. A telemetric biosensor for monitoring blood pH on-line could be used to identify and manage problems in fluid and electrolyte metabolism, cardiac and respiratory function during space flight and the acid-base status of patients without the need for venipuncture in patients on Earth. Critical to the development of biosensors is a method for evaluating their performance after implantation. Mature rats, prepared with jugular, cannulas for repeated blood samples, were exposed to a gas mixture containing high levels of carbon dioxide (7%) in a closed environment to induce mild respiratory acidosis. Serial blood gas and pH measurements in venous blood were compared with electrical responses from sensors implanted in the subcutaneous tissue. Animals became slightly tachypneic after exposure to excess CO2, but remained alert and active. After 5 minutes, basal blood pH decreased from 7.404 +/- 0.013 to 7.289 +/- 0.010 (p less than 0.001)and PC02 increased from 45 +/- 6 to 65 +/- 4 mm. Hg (p les than 0.001). Thereafter pH and blood gas parameters remained stable. Implanted sensors showed a decrease in millivolts (mV) which paralleled the change in pH and averaged 5-6 mV per 0.1 unit pH. Implanted sensors remained sensitive to modest changes in tissue pH for one week. A system for inducing acidosis in rats was developed to test the in vivo performance of pH biosensors. The system provides a method which is sensitive, rapid and reproducible in the same and different animals with full recovery, for testing the performance of sensors implanted in subcutaneous tissues.

Arnaud, Sara B.↗

Zn{sup 2+} induces apoptosis in human highly metastatic SHG-44 glioma cells, through inhibiting activity of the voltage-gated proton channel Hv1

Highlights: •Hv1 is expressed in highly metastatic glioma cell. •Zn{sup 2+} ions induces apoptosis in highly metastatic glioma cells. •Zn{sup 2+} ions markedly inhibit proton secretion. •Zn{sup 2+} ions reduce the gelatinase activity. •Inhibition of Hv1 activity via Zn{sup 2+} ions can effectively retard the cancer growth. -- Abstract: In contrast to the voltage-gated K{sup +} channels, the voltage-gated proton channel Hv1 contains a voltage-sensor domain but lacks a pore domain. Here, we showed that Hv1 is expressed in the highly metastatic glioma cell SHG-44, but lowly in the poorly metastatic glioma cell U-251. Inhibition of Hv1 activity by 140 μM zinc chloride induces apoptosis in the human highly metastatic glioma cells. Zn{sup 2+} ions markedly inhibit proton secretion, and reduce the gelatinase activity in the highly metastatic glioma cells. In vivo, the glioma tumor sizes of the implantation of the SHG-44 xenografts in nude mice that were injected zinc chloride solution, were dramatically smaller than that in the controlled groups. The results demonstrated that the inhibition of Hv1 activity via Zn{sup 2+} ions can effectively retard the cancer growth and suppress the cancer metastasis by the decrease of proton extrusion and the down-regulation of gelatinase activity. Our results suggest that Zn{sup 2+} ions may be used as a potential anti-glioma drug for glioma therapy.

60 APPLIED LIFE SCIENCES↗

Effects of dose rate on the microstructure and deuterium retention in γ-LiAlO 2 pellets

This report presents experimental findings obtained from November 2024 to September 2025. Defect accumulation and microstructural evolution during ion irradiation at elevated temperatures are governed by two competing processes: defect production, driven by dose rate, and defect recovery, controlled by defect diffusion, interaction, and annihilation. At a given dose, the resulting microstructural evolution depends on both the dose rate and irradiation temperature. As a continuation of our FY24 tritium science project, which investigated temperature effects at a fixed dose rate, this study focuses on dose-rate effects at a fixed temperature to provide deeper insights into the irradiated microstructure and compositional changes in γ-LiAlO 2 pellets. The study aims to elucidate the impact of dose rate on microstructure, precipitate morphology, deuterium retention, and lithium volatility in γ-LiAlO 2 pellets under sequential 120 keV He + and 80 keV D 2 + ion irradiation. Three dose rates of 7.3×10 4 , 2.9×10 4 and 6.8×10 5 dpa/s were applied to achieve the same total ion fluence of 2×10 17 (He + +D + )/cm 2 at 500 °C, corresponding to a maximum combined dose of 7.55 dpa at ~255 nm. The irradiated pellets were subsequently characterized using scanning transmission electron microscopy (STEM) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). The microstructural response of γ-LiAlO 2 to ion irradiation was found to be strongly dose-rate dependent. At medium and high dose rates, irradiation produced a surface amorphized layer and an underlying crystalline layer containing LiAl 5 O 8 precipitates, with implanted gases accumulating and forming blisters at the crystalline-amorphous interface. It remains to be investigated whether the amorphized layer was produced by He + ion irradiation prior to D 2 + ion irradiation. In contrast, at low dose rates, the material remained crystalline, with cavities, likely gas-filled, distributed around precipitates, within the γ-LiAlO 2 matrix, and along grain boundaries. While precipitate morphology exhibited anisotropy, their size showed little sensitivity to dose rate in the applied range of this study. This result, however, does not rule out the possibility that further reductions in dose rate could influence precipitate size. High dose-rate irradiation enhanced protonium–deuterium isotopic exchange and lithium depletion in the amorphized region. Collectively, the results show that dose rate governs amorphization, gas redistribution, isotopic exchange, and lithium depletion, providing important insights into the mechanisms underlying structural evolution in γ-LiAlO 2 pellets under reactor-relevant irradiation conditions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rechargeable metal-metal alkaline batteries: Recent advances, current issues and future research strategies

Over the past few decades, remarkable advancement has been attained in the field of rechargeable metal–metal alkaline batteries (RABs). In terms of safety, energy density, charge-discharge capacity, and long-term storage capability, metal-metal RABs (e.g., Ni–Zn, Ni–Fe, Ni–Bi, Ni–MH, Ag–Zn, Co–Zn, Cu–Zn, and Bi–Zn systems) are contemplated as the promising energy storage devices for the applications in electric vehicles (EVs), hybrid EVs, grid-scale energy storage, as well as various implantable and wearable electronic devices. Especially, Ni-MH batteries become competitive with Li-ion batteries for EVs and hybrid EVs applications due to their high tolerance against mechanical abuse, stability under wide temperature ranges, and considerable charge/discharge capacity. Meanwhile, earlier works reviewed only specific topics, so, as a rapidly growing research topic, providing a deep understanding on metal–metal RABs is timely and worthwhile. So here, in this work, we discuss the electrochemistry of all metal-metal RABs, then full cell designing with their performance will be discussed thoroughly. Further, issues associated with the existing metal–metal RABs and corresponding improvement approaches will be provided for future advances in high-performance and reliable metal-metal RABs.

25 ENERGY STORAGE↗

Ferromagnetic and paramagnetic magnetization of implanted GaN:Ho,Tb,Sm,Tm films

The SQUID magnetic measurements were performed on the GaN films prepared by metal-organic vapour phase epitaxy and implanted by Tb{sup 3+}, Tm{sup 3+}, Sm{sup 3+}, and Ho{sup 3+} ions. The sapphire substrate was checked by the electron paramagnetic resonance method which showed a content of Cr{sup 3+} and Fe{sup 3+} impurities. The samples 5 × 5 mm{sup 2} were positioned in the classical straws and within an estimated accuracy of 10{sup −6 }emu, no ferromagnetic moment was detected in the temperature region of 2–300 K. The paramagnetic magnetization was studied for parallel and perpendicular orientation. In the case of GaN:Tb sample, at T = 2 K, a pronounced anisotropy with the easy axis perpendicular to the film was observed which can be explained by the lowest quasi-doublet state of the non-Kramers Tb{sup 3+} ion. The Weiss temperature deduced from the susceptibility data using the Curie-Weiss (C-W) law was found to depend substantially on the magnetic field.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Deciphering the influence of high-flux helium plasma exposure on tungsten nanostructure growth using real-time, in situ spectroscopic ellipsometry

In situ analysis of surfaces during high-flux plasma exposure represents a long-standing challenge in the study of plasma–material interactions. While post-mortem microscopy can provide a detailed picture of structural and compositional changes, in situ techniques can capture the dynamic evolution of the surface. In this study, we demonstrate how spectroscopic ellipsometry can be applied to the real-time characterization of W nanostructure (also known as “fuzz”) growth during exposure to low temperature, high-flux He plasmas. Strikingly, over a wide range of sample temperatures and helium fluences, the measured ellipsometric parameters (Ψ,Δ) collapse onto a single curve that can be directly correlated with surface morphologies characterized by ex situ helium ion microscopy. The initial variation in the (Ψ,Δ) parameters appears to be governed by small changes in surface roughness (<50 nm) produced by helium bubble nucleation and growth, followed by the emergence of 50 nm diameter W tendrils. This basic behavior appears to be reproducible over a wide parameter space, indicating that the spectroscopic ellipsometry may be of general practical use as a diagnostic to study surface morphologies produced by high-flux He implantation in refractory metals. An advantage of the methods outlined here is that they are applicable at low incident ion energies, even below the sputtering threshold. As an example of this application, we apply in situ ellipsometry to examine how W fuzz growth is affected both by varying ion energy and the temperature of the surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of Alkoxide Precursors-Based Hybrid Coatings on Ti-6Al-4V Alloy for Biomedical Applications: Influence of pH of Sol

The Ti-6Al-4V alloy, widely used in biomedical applications, is associated with cytotoxic effects due to the release of aluminum and vanadium ions in the human body. One of the most effective ways to control the release of cytotoxic ions is through anti-corrosive coatings. Among them, the alkoxysilanes stand out for their good barrier properties and the absence of toxicity. Aiming to improve the clinical success rate of metallic implants, this study sets out to evaluate the influence of the pH of the sol on the physico-chemical, morphological, mechanical and electrochemical characteristics of hybrid films based on 3-(trimethoxysilylpropyl)methacrylate (MAP) and tetraethoxysilane (TEOS) applied to Ti-6Al-4V. The film was prepared by using the sol–gel method for pH values of 3, 4, and 5. The results indicated that maintaining the pH of the sol at 4 favors the hydrolysis rate of alkoxide precursors, which results in a uniform, dense and adherent film with excellent anti-corrosion performance.

36 MATERIALS SCIENCE↗

FORMATION OF D{sub 2}-WATER AND D{sub 2}-CARBONIC ACID IN OXYGEN-RICH SOLAR SYSTEM ICES VIA D{sup +}{sub 2} IRRADIATION

Molecular oxygen (O{sub 2}) and carbon dioxide (CO{sub 2}) ices were irradiated with energetic D{sup +}{sub 2} ions to simulate the exposure of oxygen-bearing solar system ices to magnetospheric H{sup +}{sub 2} and H{sup +} ions and energetic protons from the solar wind. The experiments provided evidence on the incorporation of the implanted deuterium and inherent formation of D{sub 2}-water (D{sub 2}O) as well as D{sub 2}-carbonic acid (D{sub 2}CO{sub 3}). In the molecular oxygen ices, the temporal profiles inferred that D{sub 2}-water formation followed successive deuterium atom addition to atomic oxygen via a D-hydroxyl radical intermediate in the matrix. In the carbon dioxide ices, D{sub 2}-carbonic acid was likely formed via successive deuterium atom reaction with cyclic carbon trioxide. These chemical processes have specific relevance to water formation on outer solar system bodies, such as the icy moons of Jupiter and Saturn, as well as possible implications for the formation of water on the lunar surface.

79 ASTRONOMY AND ASTROPHYSICS↗

A preliminary evaluation of immune stimulation following exposure to metal particles and ions using the mouse popliteal lymph node assay

The objective of this preliminary study was to evaluate the threshold for immune stimulation in mice following local exposure to metal particles and ions representative of normal-functioning cobalt-chromium (CoCr) metal-on-metal (MoM) hip implants. The popliteal lymph node assay (PLNA) was used in this study to assess immune responses in BALB/c mice following treatment with chromium-oxide (Cr{sub 2}O{sub 3}) particles, metal salts (CoCl{sub 2}, CrCl{sub 3} and NiCl{sub 2}), or Cr{sub 2}O{sub 3} particles together with metal salts using single-dose exposures representing approximately 10 days (0.000114 mg), 19 years (0.0800 mg), and 40 years (0.171 mg) of normal implant wear. The immune response elicited following treatment with Cr{sub 2}O{sub 3} particles together with metal salts was also assessed at four additional doses equivalent to approximately 1.5 months (0.0005 mg), 0.6 years (0.0025 mg), 2.3 years (0.01 mg), and 9.3 years (0.04 mg) of normal implant wear. Mice were injected subcutaneously (50 μL) into the right hind foot with the test article, or with the relevant vehicle control. The proliferative response of the draining lymph node cells (LNC) was measured four days after treatment, and stimulation indices (SI) were derived relative to vehicle controls. The PLNA was negative (SI < 3) for all Cr{sub 2}O{sub 3} particle doses, and was also negative at the lowest dose of the metal salt mixture, and the lowest four doses of the Cr{sub 2}O{sub 3} particles with metal salt mixture. The PLNA was positive (SI > 3) at the highest two doses of the metal salt mixture and the highest three doses of the Cr{sub 2}O{sub 3} particles with the metal salt mixture. The provisional NOAEL and LOAEL values identified in this study for immune activation corresponds to Co and Cr concentrations in the synovial fluid approximately 500 and 2000 times higher than that reported for normal-functioning MoM hip implants, respectively. Overall, these results indicate that normal wear conditions are unlikely to result in immune stimulation in individuals not previously sensitized to metals. - Highlights: • Immune responses in mice were assessed following treatment with Cr2O3 particles with metal salts. • The PLNA was negative (SI < 3) for all Cr2O3 particle doses. • A LOAEL for immune activation was identified at 0.04 mg of metal particles with metal salts. • A NOAEL for immune activation was identified at 0.01 mg of metal particles with metal salts.

60 APPLIED LIFE SCIENCES↗

Dramatic reduction of void swelling by helium in ion-irradiated high purity α -iron

Effect of helium on void swelling was studied in high-purity α-iron, irradiated using energetic self-ions to 157 displacements per atom (dpa) at 773 K, with and without helium co-implantation up to 17 atomic parts-per-million (appm) He/dpa. Helium is known to enhance cavity formation in metals in irradiation environments, leading to early void swelling onset. In this study, microstructure characterization by transmission electron microscopy revealed compelling evidence of dramatic swelling reduction by helium co-implantation, achieved primarily by cavity size reduction. In conclusion, a comprehensive understanding of helium induced cavity microstructure development is discussed using sink strength ratios of dislocations and cavities.

36 MATERIALS SCIENCE↗

Lunar and Planetary Science XXXV: Genesis Mission

The titles in this section include: 1) The Genesis Mission Solar Wind Collection: Solar-Wind Statistics over the Period of Collection; 2) Artificial Implantation of Noble Gases on Genesis Targets; 3) Depth Sensitive Sampling of Implanted Species in Genesis Collectors Using UV Laser Ablation and SIMS; 4) A High Energy Secondary Ion Mass Spectrometer for the Analysis of Captured Solar Wind; 5) Genesis Preliminary Examination Plans; 6) Genesis Sample Material Subdividing Plans.

Lunar and Planetary Institute↗

Interaction of low-energy implanted atomic H with slow and fast diffusing metallic impurities in Si

The interaction of hydrogen, injected into silicon using low-energy ion bombardment, with slow (Ti and V) and fast (Cr and Au) diffusing impurities was investigated. It was found that this H ion bombardment of the Si surface was effective in reducing the electrically active concentration of only the fast diffusing impurities. The results are explained by damage enhanced diffusivity and surface gettering of the fast diffusing impurities.

Singh, R.↗

Stochastic acceleration of energetic ions in Jupiter's magnetosphere

An equation governing the combined radial diffusion and stochastic acceleration of super-Alfvenic ions by magnetohydrodynamic waves in Jupiter's outer magnetosphere is derived. The formulation is based upon a total energy invariant of the adiabatic transport which applies to an isotropic distribution undergoing rapid pitch angle scattering by waves. An analytic solution to the double diffusion equation is obtained and numerical results are presented for two models of ion injection. The first model assumes S(+) and O(+) are injected throughout a broad region of space through photoionization of Jupiter's magnetospheric neutral wind and obtain an initial energy corresponding to the local corotation energy after pickup by the planetary magnetic field. The second model assumes a monoenergetic distribution of energetic protons is implanted in the middle magnetosphere by the action of field-aligned potential drops in Jupiter's auroral ionosphere. For both light and heavy ions the injection process creates a seed population of particles which are further accelerated nonadiabatically by the MHD waves and adiabatically through radial diffusion. A comparison of the theoretical results with a recent data analysis of Voyager low-energy charged particle measurements is made with very good agreement, thus providing a rigorous quantitative account of and definitive explanation for the high-energy ion component of Jupiter's magnetosphere.

Barbosa, D. D.↗

Elementary surface processes during reactive magnetron sputtering of chromium

The elementary surface processes occurring on chromium targets exposed to reactive plasmas have been mimicked in beam experiments by using quantified fluxes of Ar ions (400–800 eV) and oxygen atoms and molecules. For this, quartz crystal microbalances were previously coated with Cr thin films by means of high-power pulsed magnetron sputtering. The measured growth and etching rates were fitted by flux balance equations, which provided sputter yields of around 0.05 for the compound phase and a sticking coefficient of O{sub 2} of 0.38 on the bare Cr surface. Further fitted parameters were the oxygen implantation efficiency and the density of oxidation sites at the surface. The increase in site density with a factor 4 at early phases of reactive sputtering is identified as a relevant mechanism of Cr oxidation. This ion-enhanced oxygen uptake can be attributed to Cr surface roughening and knock-on implantation of oxygen atoms deeper into the target. This work, besides providing fundamental data to control oxidation state of Cr targets, shows that the extended Berg's model constitutes a robust set of rate equations suitable to describe reactive magnetron sputtering of metals.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thin Film Li Ion Microbatteries for NASA Applications

Rechargeable thin film microbatteries have recently become the topic of widespread research for use in low power applications such as battery-backed CMOS memory, miniaturized implantable medical devices and smart cards. In particular, the Center for Integrated Space Microsystems (CISM) at NASA's Jet Propulsion Laboratory has interest in applying this technology for secondary power systems in miniaturized satellites, microsensors, microactuators and other remote MEMS applications. The general requirements of the microbatteries for these applications are high specific energy, wide range of temperature stability. low self-discharge rate, and flexibility of cell design. The thin film Li ion materials system using LiCoO2(LiPO(x)N(1-x))SnO is expected to fulfill these requirements.

West, W. C.↗

State-of-Charge Investigation of Lithium Manganese Dioxide Primary Batteries Utilizing X-ray Computed Tomography

Lithium primary batteries (LPBs) represent a class of energy storage devices, uniquely suited for mission-critical applications including emergency backup power, aerospace and defense electronics, implantable medical devices, and remote sensing. Despite their technological maturity and distinct advantages over rechargeable lithium-ion batteries (i.e., superior shelf life and operational simplicity), state-of-charge (SoC) estimation in these batteries remains a persistent challenge due to the lack of a reliable, quantifiable diagnostic technique. In this work, we investigate X-ray computed tomography (X-CT) as a transformative and accurate SoC estimation technique for LPBs. Results gained through X-CT measurements reveal systematic, quantifiable structural changes in cathode morphology and geometry during discharge, establishing a direct structural basis for SoC estimation, with a maximum relative standard deviation of 2.3%. This work establishes a pathway toward operando, imaging-driven SoC diagnostics that can significantly enhance the reliability of SoC estimation in LPBs.

25 ENERGY STORAGE↗

Biomedical applications of ion-beam technology

Microscopically-rough surface texture of various biocompatible alloys and polymers produced by ion-beam sputtering may result in improvements in response of hard or soft tissue to various surgical implants.

Banks, B. A.↗