Present Status and Future Developments in Proton Therapy

Within the past few years, interest in proton therapy has significantly increased. This interest has been generated by a number of factors including: 1) the reporting of positive clinical results using proton beams; 2) approval of reimbursement for delivery of proton therapy; 3) the success of hospital-based proton therapy centers; and 4) the availability of modern, integrated proton therapy technology for hospital-based facilities. In the United States, this increased interest has occurred particularly at the level of smaller academic hospitals, community medical centers, and large private practices; however, interest from large academic centers continues to be strong. Particular interest exists regarding smaller and less-expensive proton therapy systems, especially the so-called 'single-room' systems. In this paper, the advantages and disadvantages of 1-room proton therapy systems will be discussed. The emphasis on smaller and cheaper proton therapy facilities has also generated interest in new proton-accelerating technologies such as superconducting cyclotrons and synchrocyclotrons, laser acceleration, and dielectric-wall accelerators. Superconducting magnets are also being developed to decrease the size and weight of isocentric gantries. Another important technical development is spot-beam scanning, which offers the ability to deliver intensity-modulated proton treatments (IMPT). IMPT has the potential to provide dose distributions that are superior to those for photon intensity modulation techniques (IMXT) and to improve clinical outcomes for patients undergoing cancer therapy. At the present time, only two facilities--one in Europe and one in the United States--have the ability to deliver IMPT treatments, however, within the next year or two several additional facilities are expected to achieve this capability.

43 PARTICLE ACCELERATORS↗

Genetic Linkage Mapping and Transmission Ratio Distortion in a Three-Generation Four-Founder Population of Panicum virgatum (L.)

Switchgrass (Panicum virgatum L.), a warm season, C4, perennial grass, is one of the predominant grass species of the North American tall grass prairies. It is viewed as a high-potential bioenergy feedstock species because it can produce large amounts of lignocellulosic material with relatively few inputs. The objectives of this project were to develop an advanced switchgrass population and use it for the construction of genetic linkage maps and trait characterization. A three-generation, four-founder population was created and a total of 182 progeny of this advanced population were genotyped, including a mixture of self-pollinated and hybrid individuals. The female map integrated both subpopulations and covered 1629 cM of the switchgrass genome, with an average map length of 91 cM per linkage group. The male map of the hybrid progeny covered 1462 cM, with an average map length of 81 cM per linkage group. Average marker density of the female and male maps was 3.9 and 3.5 cM per marker interval, respectively. Based on the parental maps, the genome length of switchgrass was estimated to be 1776 cM and 1596 cM for the female map and male map, respectively. The proportion of the genome within 5 cM of a mapped locus was estimated to be 92% and 93% for the female map and male map, respectively. Thus, the linkage maps have covered most of the switchgrass genome. The assessment of marker transmission ratio distortion found that 26% of the genotyped markers were distorted from either 1:1 or 3:1 ratios expected for segregation of single dose markers in one or both parents, respectively. Several regions affected by transmission ratio distortion were found, with linkage groups Ib-m and VIIIa-f most affected.

59 BASIC BIOLOGICAL SCIENCES↗

Exploring the fusion power plant design space: comparative analysis of positive and negative triangularity tokamaks through optimization

The optimal configuration choice between positive triangularity (PT) and negative triangularity (NT) tokamaks for fusion power plants hinges on navigating different operational constraints rather than achieving specific plasma performance metrics. This study presents a systematic comparison using constrained multi-objective optimization with the integrated FUsion Synthesis Engine (FUSE) framework. Over 200 000 integrated design evaluations were performed exploring the trade-offs between capital cost minimization and operational reliability (maximizing q 95 ) while satisfying engineering constraints including 250 ± 50 MW net electric power, tritium breeding ratio > 1.1, power exhaust limits and an hour flattop time. Both configurations achieve similar cost-performance Pareto fronts through contrasting design philosophies. PT, while demonstrating resilience to pedestal degradation (compensating for up to 40% reduction), are constrained to larger machines (R 0 > 6.5 m) by the narrow operational window between L–H threshold requirements and the research-established power exhaust limit (P sol /R < 15 MW m –1 ). This forces optimization through comparatively reduced magnetic field (∼8 T). NT configurations exploit their freedom from these constraints to access compact, high-field designs (R 0 ~ 5.5 m, B 0 >12 T), creating natural synergy with advancing HTS technology. Sensitivity analyses reveal that PT’s economic viability depends critically on uncertainties in L–H threshold scaling and power handling limits. Notably, a 50% variation in either could eliminate viable designs or enable access to the compact design space. These results suggest configuration selection should be risk-informed: PT offers the lowest-cost path when operational constraints can be confidently predicted, while NT is robust to large variations in constraints and physics uncertainties.

FUSE framework↗

Environmental Biosciences Report for Year 3

In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally prominent research program is due, in part, to its ability to task-organize scientific expertise from multiple disciplines in addressing these complex problems Current research projects have focused EBP talent and resources on providing the scientific basis for risk-based standards, risk-based decision making and the accelerated clean-up of widespread environmental hazards. These hazards include trichloroethylene and low-dose ionizing radiation. Work on the trichloroethylene research projects has been slowed as a result of funding uncertainties. The impact of these funding uncertainties has been discussed with the DOE. Plans for restructuring the performance schedule of the trichloroethylene projects have been submitted to the department. A project is also being conducted in the use of geographical information system technology to analyze population health risks related to environmental hazards as a tool for risk based decision-making. Questions, comments or requests for further information concerning the activities under this cooperative agreement can be forwarded to Dr. Lawrence C. Mohr in the EBP office of the Medical University of South Carolina at (843) 792-1532.

01 COAL, LIGNITE, AND PEAT↗

Environmental Biosciences Program Quarterly Report

In May 2002, the United States Department of Energy (DOE) signed Assistance Instrument Number DE-FC09-02CH11109 with the Medical University of South Carolina (MUSC) to support the Environmental Biosciences Program (EBP). This funding instrument replaces DOE Assistance Instrument Number DE-FC02-98CH10902. EBP is an integrated, multidisciplinary scientific research program, employing a range of research initiatives to identify, study and resolve environmental health risks. These initiatives are consistent with the MUSC role as a comprehensive state-supported health sciences institution and with the nation's need for new and better approaches to the solution of a complex and expansive array of environment-related health problems. The intrinsic capabilities of a comprehensive health sciences institution enable MUSC to be a national resource for the scientific investigation of environmental health issues. EBPs success as a nationally prominent research program is due, in part, to its ability to task-organize scientific expertise from multiple disciplines in addressing these complex problems Current research projects have focused EBP talent and resources on providing the scientific basis for risk-based standards, risk-based decision making and the accelerated clean-up of widespread environmental hazards. These hazards include trichloroethylene and low-dose ionizing radiation. Work on the trichloroethylene research projects has been slowed as a result of funding uncertainties. The impact of these funding uncertainties has been discussed with the DOE. Plans for restructuring the performance schedule of the trichloroethylene projects have been submitted to the department. A project is also being conducted in the use of geographical information system technology to analyze population health risks related to environmental hazards as a tool for risk-based decision-making.

54 ENVIRONMENTAL SCIENCES↗

Shielding design for a chip irradiation test facility at SNS - Paper 119

As digital and analog circuits are more and more sophisticatedly integrated, they become increasingly susceptible to single event upsets (SEU), a cause of electronic equipment malfunction induced by cosmic rays with particular hazard potential for aviation equipment. Electronic chips sensitive to SEU have to be tested in a simulated comic ray environment to ensure their reliability. It is found that the spallation induced fast neutron spectrum is very close to the neutron spectrum of the cosmic ray. Hence, a conceptual design study of a chip irradiation test facility is funded by FAA to be carried out at SNS, the world's most powerful accelerator driven facility for neutron scattering studies on materials. Compared to existing/being construct chip irradiation test facilities at LANL and ISIS, SNS can provide wider neutron energy range and much higher fluxes. This study focuses on the aspect of shielding design for such a chip irradiation facility. A number of medium-weighted and heavy materials were examined for efficiency in reducing radiation dose rate. In general, the smaller the target monolith is while satisfying the personnel-protection-driven radiation dose rate limit at its outside, the closer to the target chips could be placed and thus less beam power it demands to satisfy a given irradiation flux requirement. Before proceed to the shielding design, the neutron source coming off the target has to be determined for selecting a best spot for chip irradiation test, in which the incoming fast neutron spectrum approximate most to the atmospheric radiation condition. It also provides a source term for the following shielding design of the irradiation enclosure. (authors)

36 MATERIALS SCIENCE↗

SU-F-E-20: A Mathematical Model of Linac Jaw Calibration Integrated with Collimator Walkout

Purpose: Accurate jaw calibration is possible, but it does not necessarily achieve good junctions because of collimator rotation walkout. We developed a mathematical model seeking to pick an origin for calibration that minimizes the collimator walkout effect. Methods: We use radioopaque markers aligned with crosshair on the EPID to determine the collimator walkout at collimator angles 0°, 90° and 270°. We can accurately calibrate jaws to any arbitrary origin near the radiation field centre. While the absolute position of an origin moves with the collimator walkout, its relative location to the crosshair is an invariant. We studied two approaches to select an optimal origin. One approach seeks to bring all three origin locations (0°–90°–270°) as close as possible by minimizing the perimeter of the triangle formed by these points. The other approach focuses on the gap for 0°–90° junctions. Results: Our perimeter cost function has two variables and non-linear behaviour. Generally, it does not have zero-perimeter-length solution which leads to perfect jaw matches. The zero solution can only be achieved, if the collimator rotates about a single fixed axis. In the second approach, we can always get perfect 0°–0° and 0°–90° junctions, because we ignore the 0°–270° situation. For our TrueBeams, both techniques for selecting an origin improved junction dose inhomogeneities to less than ±6%. Conclusion: Our model considers the general jaw matching with collimator rotations and proposes two potential solutions. One solution optimizes the junction gaps by considering all three collimator angles while the other only considers 0°–90°. The first solution will not give perfect matching, but can be clinically acceptable with minimized collimator walkout effect, while the second can have perfect junctions at the expense of the 0°–270° junctions. Different clinics might choose between these two methods basing on their clinical practices.

60 APPLIED LIFE SCIENCES↗

SU-F-BRD-06: Dosimetric Cost of a GTV Margin for Simultaneous Integrated Intra- Prostatic Boost Treatments

Purpose: Quantify the dosimetric cost for a margin around the MRI-defined high risk GTV for simultaneous integrated intra-prostatic boosts (SIIB) treated with RapidArc. Methods: For external beam radiotherapy of the prostate, a 3-7 mm PTV margin is typically used to account for setup and intra-fraction uncertainties after adjusting for inter-fraction motion. On the other hand, our current paradigm is to treat the MRI-defined high risk GTV with no margin. In this work, 11 patients treated SIIB (7 post-prostatectomy, 4 intact prostate) with RapidArc were re-planned with 1-5 mm margins around the GTV to quantify dosimetric effects. Two 358 degree, 10 MV RapidArcs were used to deliver 68 Gy (76.5 Gy boost) to the post-prostatectomy patients and 80 Gy (86 Gy boost) to the intact prostates. Paired, two tail t-tests were used to determine if there were any significant differences (p<0.05) in the total MUs and dosimetric parameters used to evaluate rectum, bladder, and PTV dose with and without margin. Results: The average GTV volume without margin was 8.1cc (2.8% of the PTV volume) while the average GTV volume with a 5 mm margin was 20.1cc (9.0% of the PTV volume). GTV volumes ranged from 0.2% of the PTV volume up to 33.0%. Despite these changes in volume, the only statistical difference was found for the rectal V65 Gy with a 5 mm margin (18.6% vs. 19.4%; p-value = 0.026) when all patients were considered as a single group. No difference was found when analyzed as two groups. The rectum V40Gy, bladder V40Gy and V65Gy, PTV Dmax and D95% or the total MUs did not show any significant difference for any margin. Conclusion: A 4 mm margin on the high risk GTV is possible with no statistically significant change in dosimetry or total MUs. Further work will assess the appropriate margin required for intra-prostatic boosts.

60 APPLIED LIFE SCIENCES↗

SU-F-T-495: Method for Simultaneous Commissioning of Multiple Truebeam (TB) Linacs: Small Field Data and the Choice of Dosimetric Lead Gap (DLG)

Purpose: Many times a set of multiple Varian-Truebeam (TB) linacs are acquired by an institution. Since “beam matching” is an important requirement for many facilities, we developed a strategy to perform a “simultaneous” commissioning between multiple linacs.Methods and Materials: We first commissioned the required photon beam data for eclipse on the 1st TB for all the energy modalities with a beam scanning system, while integrated measurements for output factors, of all field sizes (from 1×1 to 40×40cm{sup 2}) were conducted on the 2nd TB. Care was exercised during small field dosimetry so the appropriate detectors were used with data taken between two detectors be “linked” to a larger field size (4×4cm{sup 2}) with the “daisy-chaining” technique via: OF=[M-PTW(fs)×(M-PTW(4×4))-1]×[MA12s(4×4)×(M-A12S(10×10))−1]. For all energy modalities, data that span the entire range of field size, was repeated on the next TB linac, for verification. The primarily energy-dependent dosimetric leaf gap (DLG) which was measured separately on each TB. The modeled data was validated with special measurements conducted on both linacs during commissioning. Results: Our data agreed with the “TB representative beam data” to within 0.5% for all energy modalities and field sizes ≥3×3cm2. Sample depth-doses and cross-profiles of a 3×3cm2 between the linacs agreeing to within 1% between linacs. The measured DLGs were quite different with a uniform difference of 1.3% between the two linacs. The measured DLG values are independent of the average dose rate and medium used for the measurements. Conclusion: A comprehensive method of commissioning identical Varian-TB linacs, outlining the critical issues, especially small field dosimetry and DLG. The dosimetric effect of different DLG values, when it comes to, dynamic delivery and data comparisons will be presented. The dependence of DLG value on the measurement medium (in-air vs. water) or dose rate used will also be discussed. This work was supported by CAMC Cancer Center and Alliance Oncology.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-I-77: A Noise Reduction Technique for Energy-Resolved Photon-Counting Detectors

Purpose: Finding the optimal energy threshold setting for an energy-resolved photon-counting detector has an important impact on the maximization of contrast-to-noise-ratio (CNR). We introduce a noise reduction method to enhance CNR by reducing the noise in each energy bin without altering the average gray levels in the projection and image domains. Methods: We simulated a four bin energy-resolved photon-counting detector based on Si with a 10 mm depth of interaction. TASMIP algorithm was used to simulate a spectrum of 65 kVp with 2.7 mm Al filter. A 13 mm PMMA phantom with hydroxyapatite and iodine at different concentrations (100, 200 and 300 mg/ml for HA, and 2, 4, and 8 mg/ml for Iodine) was used. Projection-based and Image-based energy weighting methods were used to generate weighted images. A reference low noise image was used for noise reduction purposes. A Gaussian-like weighting function which computes the similarity between pixels of interest was calculated from the reference image and implemented on a pixel by pixel basis for the noisy images. Results: CNR improvement compared to different methods (Charge-Integrated, Photon-Counting and Energy-Weighting) and after noise reduction was highly task-dependent. The CNR improvement with respect to the Charge-Integrated CNR for hydroxyapatite and iodine were 1.8 and 1.5, respectively. In each of the energy bins, the noise was reduced by approximately factor of two without altering their respective average gray levels. Conclusion: The proposed noise reduction technique for energy-resolved photon-counting detectors can significantly reduce image noise. This technique can be used as a compliment to the current energy-weighting methods in CNR optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An imaging evaluation of the simultaneously integrated boost breast radiotherapy technique

To evaluate in-field megavoltage (MV) imaging of simultaneously integrated boost (SIB) breast fields to determine its feasibility in treatment verification for the SIB breast radiotherapy technique, and to assess whether the current-imaging protocol and treatment margins are sufficient. For nine patients undergoing SIB breast radiotherapy, in-field MV images of the SIB fields were acquired on days that regular treatment verification imaging was performed. The in-field images were matched offline according to the scar wire on digitally reconstructed radiographs. The offline image correction results were then applied to a margin recipe formula to calculate safe margins that account for random and systematic uncertainties in the position of the boost volume when an offline correction protocol has been applied. After offline assessment of the acquired images, 96% were within the tolerance set in the current department-imaging protocol. Retrospectively performing the maximum position deviations on the Eclipse™ treatment planning system demonstrated that the clinical target volume (CTV) boost received a minimum dose difference of 0.4% and a maximum dose difference of 1.4% less than planned. Furthermore, applying our results to the Van Herk margin formula to ensure that 90% of patients receive 95% of the prescribed dose, the calculated CTV margins were comparable to the current departmental procedure used. Based on the in-field boost images acquired and the feasible application of these results to the margin formula the current CTV-planning target volume margins used are appropriate for the accurate treatment of the SIB boost volume without additional imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation-induced vacancy injection in heterogeneous multiphase materials

Understanding the synergy between corrosion and defect dynamics is a key consideration in the development of advanced materials for extreme environments. Here, we reveal a surprising phenomenon for the transport of point defects induced by irradiation in a heterogeneous multiphase structure of a metal and an oxide, similar to that formed under metal corrosion that takes place in most environments. Despite the confinement of the produced damage within the oxide, vacancies were injected into the unirradiated metal and coarsened with dose. Furthermore, the results show that the nature of the oxide layer dictates the defect evolution in the metal layer. This work reveals an interesting mechanism for point defect interactions in multiphase materials, with broad implications in many fields, while also emphasizing the complex coupling between corrosion and irradiation. Corrosion leads to the formation of multiphase materials, while irradiation enhances diffusion within the heterogeneous phases, which can impact corrosion rates.

36 MATERIALS SCIENCE↗

Radiation damage in nanostructured materials

Materials subjected to high dose irradiation by energetic particles often experience severe damage in the form of drastic increase of defect density, and significant degradation of their mechanical and physical properties. Extensive studies on radiation effects in materials in the past few decades show that, although nearly no materials are immune to radiation damage, the approaches of deliberate introduction of certain types of defects in materials before radiation are effective in mitigating radiation damage. Nanostructured materials with abundant internal defects have been extensively investigated for various applications. The field of radiation damage in nanostructured materials is an exciting and rapidly evolving arena, enriched with challenges and opportunities. In this review article, we summarize and analyze the current understandings on the influence of various types of internal defect sinks on reduction of radiation damage in primarily nanostructured metallic materials, and partially on nanoceramic materials. We also point out open questions and future directions that may significantly improve our fundamental understandings on radiation damage in nanomaterials. Finally, the integration of extensive research effort, resources and expertise in various fields may eventually lead to the design of advanced nanomaterials with unprecedented radiation tolerance.

36 MATERIALS SCIENCE↗

Effect of Cu contamination on recombination of O atoms on a plasma-oxidized silicon surface

In the dual damascene microelectronics integration scheme during the last stage of plasma etching of dielectrics down to underlying Cu layers, Cu is sputtered onto the reactor walls and is believed to cause a drift in etching rates. For photoresist etching in an O{sub 2}-containing plasma, a drop in etching rate suggests that Cu could cause a decrease in the O-atom concentration in the plasma, due perhaps to an increase in the O recombination rate on the chamber walls. We therefore studied the effects of traces of Cu on O recombination on an oxygen plasma-conditioned surface, using the spinning wall technique. With this method, a cylindrical substrate, here coated in situ with sputter-deposited Si and then oxidized in an O{sub 2} plasma, is rotated past skimmers, allowing the surface to be periodically exposed to the plasma and an Auger electron spectrometer with a pressure gauge in a differentially pumped chamber. Between plasma exposures, the sample could also be dosed with Cu from an evaporation source in a differentially pumped chamber. With no Cu on the surface, a pressure rise was observed in the Auger chamber, due to desorption of recombined O{sub 2}. These measurements were used to derive a Langmuir-Hinshelwood recombination coefficient of gamma{sub O}=0.043 for the steady-state oxidized Si, Cu-free surface. The surface was then coated with a small fraction of a monolayer (roughly approx0.002 monolayers of Cu with a dose of approx1.4x10{sup 13} cm{sup -2} and an assumed sticking coefficient of 0.3) and gamma{sub O} was found to increase to 0.069. Further dosing with Cu did not produce any further increases in gamma{sub O}. The initial low gamma{sub O} value could not be recovered by coating the surface with sputter Si, apparently due to rapid outdiffusion of Cu through Si at room temperature. Cu catalyzed recombination of O is ascribed to a redox cycling between Cu{sup +} and Cu{sup 2+} oxidation states.

36 MATERIALS SCIENCE↗

Quantitative Assessment of Detection Frequency for the INL Ambient Air Monitoring Network

A quantitative assessment of the Idaho National Laboratory (INL) air monitoring network was performed using frequency of detection as the performance metric. The INL air monitoring network consists of 37 low-volume air samplers in 31 different locations. Twenty of the samplers are located on INL (onsite) and 17 are located off INL (offsite). Detection frequencies were calculated using both BEA and ESER laboratory minimum detectable activity (MDA) levels. The CALPUFF Lagrangian puff dispersion model, coupled with 1 year of meteorological data, was used to calculate time-integrated concentrations at sampler locations for a 1-hour release of unit activity (1 Ci) for every hour of the year. The unit-activity time-integrated concentration (TICu) values were calculated at all samplers for releases from eight INL facilities. The TICu values were then scaled and integrated for a given release quantity and release duration. All facilities modeled a ground-level release emanating either from the center of the facility or at a point where significant emissions are possible. In addition to ground-level releases, three existing stacks at the Advanced Test Reactor Complex, Idaho Nuclear Technology and Engineering Center, and Material and Fuels Complex were also modeled. Meteorological data from the 35 stations comprising the INL Mesonet network, data from the Idaho Falls Regional airport, upper air data from the Boise airport, and three-dimensional gridded data from the weather research forecasting model were used for modeling. Three representative radionuclides identified as key radionuclides in INL’s annual National Emission Standards for Hazardous Air Pollutants evaluations were considered for the frequency of detection analysis: Cs-137 (beta-gamma emitter), Pu-239 (alpha emitter), and Sr-90 (beta emitter). Source-specific release quantities were calculated for each radionuclide, such that the maximum inhalation dose at any publicly accessible sampler or the National Emission Standards for Hazardous Air Pollutants maximum exposed individual location (i.e., Frenchman’s Cabin) was no more than 0.1 mrem yr–1 (i.e., 1% of the 10 mrem yr–1 standard). Detection frequencies were calculated separately for the onsite and offsite monitoring network. As expected, detection frequencies were generally less for the offsite sampling network compared to the onsite network. Overall, the monitoring network is very effective at detecting the potential releases of Cs-137 or Sr-90 from all sources/facilities using either the ESER or BEA MDAs. The network was less effective at detecting releases of Pu-239. Maximum detection frequencies for Pu-239 using ESER MDAs ranged from 27.4 to 100% for onsite samplers and 3 to 80% for offsite samplers. Using BEA MDAs, the maximum detection frequencies for Pu-239 ranged from 2.1 to 100% for onsite samplers and 0 to 5.9% for offsite samplers. The only release that was not detected by any of the samplers under any conditions was a release of Pu-239 from the Idaho Nuclear Technology and Engineering Center main stack (CPP-708). The methodology described in this report could be used to improve sampler placement and detection frequency, provided clear performance objectives are defined.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Treatment planning strategy for whole-brain radiotherapy with hippocampal sparing and simultaneous integrated boost for multiple brain metastases using intensity-modulated arc therapy

Purpose: To retrospectively evaluate the accuracy, plan quality and efficiency of intensity-modulated arc therapy (IMAT) for hippocampal sparing whole-brain radiotherapy (HS-WBRT) with simultaneous integrated boost (SIB) in patients with multiple brain metastases (m-BM). Materials and methods: A total of 5 patients with m-BM were retrospectively replanned for HS-WBRT with SIB using IMAT treatment planning. The hippocampus was contoured on diagnostic T1-weighted magnetic resonance imaging (MRI) which had been fused with the planning CT image set. The hippocampal avoidance zone (HAZ) was generated using a 5-mm uniform margin around the paired hippocampi. The m-BM planning target volumes (PTVs) were contoured on T1/T2-weighted MRI registered with the 3D planning computed tomography (CT). The whole-brain planning target volume (WB-PTV) was defined as the whole-brain tissue volume minus HAZ and m-BM PTVs. Highly conformal IMAT plans were generated in the Eclipse treatment planning system for Novalis-TX linear accelerator consisting of high-definition multileaf collimators (HD-MLCs: 2.5-mm leaf width at isocenter) and 6-MV beam. Prescription dose was 30 Gy for WB-PTV and 45 Gy for each m-BM in 10 fractions. Three full coplanar arcs with orbit avoidance sectors were used. Treatment plans were evaluated using homogeneity (HI) and conformity indices (CI) for target coverage and dose to organs at risk (OAR). Dose delivery efficiency and accuracy of each IMAT plan was assessed via quality assurance (QA) with a MapCHECK device. Actual beam-on time was recorded and a gamma index was used to compare dose agreement between the planned and measured doses. Results: All 5 HS-WBRT with SIB plans met WB-PTV D{sub 2%}, D{sub 98%}, and V{sub 30} {sub Gy} NRG-CC001 requirements. The plans demonstrated highly conformal and homogenous coverage of the WB-PTV with mean HI and CI values of 0.33 ± 0.04 (range: 0.27 to 0.36), and 0.96 ± 0.01 (range: 0.95 to 0.97), respectively. All 5 hippocampal sparing patients met protocol guidelines with maximum dose and dose to 100% of hippocampus (D{sub 100%}) less than 16 and 9 Gy, respectively. The dose to the optic apparatus was kept below protocol guidelines for all 5 patients. Highly conformal and homogenous radiosurgical dose distributions were achieved for all 5 patients with a total of 33 brain metastases. The m-BM PTVs had a mean HI = 0.09 ± 0.02 (range: 0.07 to 0.19) and a mean CI = 1.02 ± 0.06 (range: 0.93 to 1.2). The total number of monitor units (MU) was, on average, 1677 ± 166. The average beam-on time was 4.1 ± 0.4 minute . The IMAT plans demonstrated accurate dose delivery of 95.2 ± 0.6%, on average, for clinical gamma passing rate with 2%/2-mm criteria and 98.5 ± 0.9%, on average, with 3%/3-mm criteria. Conclusions: All hippocampal sparing plans were considered clinically acceptable per NRG-CC001 dosimetric compliance criteria. IMAT planning provided highly conformal and homogenous dose distributions for the WB-PTV and m-BM PTVs with lower doses to OAR such as the hippocampus. These results suggest that HS-WBRT with SIB is a clinically feasible, fast, and effective treatment option for patients with a relatively large numbers of m-BM lesions.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-AB-BRC-10: Modeling of Radiotherapy Linac Source Terms Using ARCHER Monte Carlo Code: Performance Comparison of GPU and MIC Computing Accelerators

Purpose: (1) To perform phase space (PS) based source modeling for Tomotherapy and Varian TrueBeam 6 MV Linacs, (2) to examine the accuracy and performance of the ARCHER Monte Carlo code on a heterogeneous computing platform with Many Integrated Core coprocessors (MIC, aka Xeon Phi) and GPUs, and (3) to explore the software micro-optimization methods. Methods: The patient-specific source of Tomotherapy and Varian TrueBeam Linacs was modeled using the PS approach. For the helical Tomotherapy case, the PS data were calculated in our previous study (Su et al. 2014 41(7) Medical Physics). For the single-view Varian TrueBeam case, we analytically derived them from the raw patient-independent PS data in IAEA’s database, partial geometry information of the jaw and MLC as well as the fluence map. The phantom was generated from DICOM images. The Monte Carlo simulation was performed by ARCHER-MIC and GPU codes, which were benchmarked against a modified parallel DPM code. Software micro-optimization was systematically conducted, and was focused on SIMD vectorization of tight for-loops and data prefetch, with the ultimate goal of increasing 512-bit register utilization and reducing memory access latency. Results: Dose calculation was performed for two clinical cases, a Tomotherapy-based prostate cancer treatment and a TrueBeam-based left breast treatment. ARCHER was verified against the DPM code. The statistical uncertainty of the dose to the PTV was less than 1%. Using double-precision, the total wall time of the multithreaded CPU code on a X5650 CPU was 339 seconds for the Tomotherapy case and 131 seconds for the TrueBeam, while on 3 5110P MICs it was reduced to 79 and 59 seconds, respectively. The single-precision GPU code on a K40 GPU took 45 seconds for the Tomotherapy dose calculation. Conclusion: We have extended ARCHER, the MIC and GPU-based Monte Carlo dose engine to Tomotherapy and Truebeam dose calculations.

60 APPLIED LIFE SCIENCES↗

{sup 33}S for Neutron Capture Therapy: Nuclear Data for Monte Carlo Calculations

A study of the nuclear data required for the Monte Carlo simulation of boron neutron capture therapy including the {sup 33}S isotope as an enhancer of the dose at small depths has been performed. In particular, the controversy on the available data for the {sup 33}S(n, α) cross section will be shown, which motivates new measurements. In addition to this, kerma factors for the main components of tissue are calculated with the use of fitting functions. Finally, we have applied these data to a potential neutron capture treatment with boron and sulfur addition to tissue in which part of the hydrogen atoms are replaced by deuterium, which improves the procedure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗