Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INSTALLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

2020 Hyperion Infrasound Sensor Equilibration Evaluation

Sandia National Laboratories has performed testing on several Hyperion 5313A infrasound sensors in order to determine the length of time it takes for the sensors to thermally equilibrate under a variety of environmental conditions. The motivation for performing these tests is to aid in determining suitable procedures for station operators to follow when installing these sensors. The desired outcome is for the station operators to be able to determine more quickly and reliably whether the sensors are performing correctly at the time of installation.

47 OTHER INSTRUMENTATION↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Results for Sensor Assignment Problem as Solved on a Multi-Node Cluster

An earlier report described a procedure for optimal sensor set selection and its implementation on a computational cluster. This new and innovative capability was developed to facilitate a reduction in operations staffing levels to improve plant economics. By automating surveillance and maintenance tasks through early detection of degrading sensors and equipment, staff can be more efficiently deployed. The method uses automated reasoning and domain knowledge in the form of the conservation equations to infer from plant measurements the state of equipment health. Inclusion of domain knowledge addresses the problem that exists with pure data-driven methods that there are no rigorous guidelines for determining what constitutes an adequate sensor set. Formalizing the procedure for sensor set selection as we have done results in a more reliable and explainable diagnosis of plant equipment health. Importantly, from the standpoint of the plant owner, personnel are provided with an early and explicit diagnosis of an equipment problem. That in principle automates the process and eliminates having to send personnel into the plant to find the cause as typically occurs when a data-driven method detects an anomaly. In this report we describe first results obtained using a computational cluster to solve the sensor set selection problem as framed above. The case described addresses the problem of equipment health monitoring in the high-pressure (HP) feedwater system of a pressurized light water reactor as seen through the eyes of our collaborating utility partner. Maintenance of this system can amount to millions of dollars per year if equipment health issues go undiagnosed and lead to loss of function. On examining the potential that is inherent in the installed sensor set for diagnosing equipment health degradation, it was found that greater fault resolution capability can be achieved using a sensor set that is 20 percent fewer in number. The take-away is that compared to the installed sensor set there exists a more strategic assignment of sensors that will furnish better health monitoring capability and with fewer sensors. Where the problem defies solution by manual inspection, as is the case here, one can be found by an algorithm. The solution was obtained in four hours using 30 computational cores. The HP feedwater problem as posed above illustrates the added value of approaching the sensor selection problem as one amenable to algorithmic solution. This problem is of interest to advanced reactor designers and to utilities that are setting up remote monitoring and diagnostic centers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Considerations for Distributed Energy Resource Honeypots and Canaries

There are now over 2.5 million Distributed Energy Resource (DER) installations connected to the U.S. power system. These installations represent a major portion of American electricity critical infrastructure and a cyberattack on these assets in aggregate would significantly affect grid operations. Virtualized Operational Technology (OT) equipment has been shown to provide practitioners with situational awareness and better understanding of adversary tactics, techniques, and procedures (TTPs). Deploying synthetic DER devices as honeypots and canaries would open new avenues of operational defense, threat intelligence gathering, and empower DER owners and operators with new cyber-defense mechanisms against the growing intensity and sophistication of cyberattacks on OT systems. Well-designed DER canary field deployments would deceive adversaries and provide early-warning notifications of adversary presence and malicious activities on OT networks. In this report, we present progress to design a high-fidelity DER honeypot/canary prototype in a late-start Laboratory Directed Research and Development (LDRD) project.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utility-Scale Solar, 2021 Edition: Empirical Trends in Deployment, Technology, Cost, Performance, PPA Pricing, and Value in the United States [Slides]

Berkeley Lab’s “Utility-Scale Solar, 2021 Edition” provides an overview of key trends in the U.S. market, with a focus on 2020. Highlights of this year’s update include: A record of nearly 9.6 GWAC of new utility-scale PV capacity came online in 2020, bringing cumulative installed capacity to more than 38.7 GWAC across 43 states. 89% of all new utility-scale PV capacity added in 2020 uses single-axis tracking. Median installed project costs declined to $\$$1.4/WAC (or $\$$1.1/WDC) in 2020. Project-level capacity factors vary widely, from 9% to 36% (on an AC basis), with a sample median of 24%. The report explores drivers of this variation. Utility-scale PV’s LCOE fell to $\$$34/MWh in 2020 ($\$$28/MWh if factoring in the federal investment tax credit, or ITC). PPA prices have largely followed the decline in solar’s LCOE over time, but have stagnated more recently. Prices from a sample of recent contracts average just above $\$$20/MWh (levelized). In 2020, solar’s average market value (defined in the report to include only energy and capacity value) exceeded average wholesale prices in 12 of the 17 balancing authorities analyzed (including 4 of the 7 independent system operators across the United States). Adding battery storage is one way to increase the value of solar. Our public data file tracks metadata for more than 150 PV+battery hybrid projects that are already online or that have secured offtake arrangements. At the end of 2020, there were at least 460 GW of utility-scale solar power capacity within the interconnection queues across the nation, 160 GW of which include batteries. For more information, and to explore related interactive data visualizations, go to utilityscalesolar.lbl.gov.

14 SOLAR ENERGY↗

Thermal Hydraulic Experimental Test Article (FY21 Final Report)

The Thermal Hydraulic Experimental Test Article (THETA) is a facility that will be used to develop sodium components and instrumentation as well as acquire experimental data for validation of reactor thermal hydraulic and safety analysis codes. The facility will simulate nominal conditions as well as protected/unprotected loss of flow accidents in a sodium-cooled fast reactor (SFR). High fidelity distributed temperature profiles of the developed flow field will be acquired with Rayleigh backscatter based optical fiber temperature sensors. The facility is being designed in partnership with systems code experts to tailor the experiment to ensure the most relevant and highest quality data for code validation. THETA is comprised of a traditional primary and secondary system. The primary system is submerged in the pool of sodium and consists of a pump, electrically heated core, intermediate heat exchanger, and connected piping and thermal barriers (redan). The secondary system, located outside of the sodium pool, consists of a pump, sodium to air heat exchanger, and connected piping and valves. Figure 1 illustrates the main components of the primary system. THETA has been installed in the Mechanisms Engineering Test Loop (METL) with the primary system in the 28 inch Test Vessel #4, Figure 2 and Figure 3. Since the FY20 THETA status report, further water shakedown testing was performed, some final welding modifications were performed, all system components were sanitized, dry assembled, and commissioned. The THETA submersible electromagnetic flowmeter was welded closed to hermetically seal internal components from sodium followed by a helium leak check for the final time. Following installation of THETA into vessel #4, all data acquisition and control systems were brought online and commissioned at room temperature in the argon gas space of the empty vessel. The vessel zone 1 heaters were reinstalled and the flange was then insulated. The vessel 4 heaters were brought to a temperature of 100 °C and the THETA pump was jogged at 600 RPM to ensure it was functioning correctly. The secondary, AC Conduction based electromagnetic pump from CMI Novacast (product number CA-15) was ordered and will be delivered in late calendar year 2021. The custom designed permanent magnet based secondary flowmeter was designed, a drawing package and manufacturing specification created and quote requested from a machine shop. The intermediate heat exchanger design was completed and a drawing package is currently in progress. During the middle of calendar year 2021 the Building 308 sodium scrubber system was shut down in order to replaced some corroded piping and facilitate improvements on the system, thus requiring the sodium in METL to remain frozen. This has imposed a delay in filling vessel 4 with sodium to begin THETA testing. Sodium testing is expected to begin in early fiscal year 2022 as all THETA primary systems are operational.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

UKy-CAER Heat Integrated Transformative CO 2 Capture Process in Pulverized Coal Power Plants

The goal of this Phase II Topical Report is to summarize the work for public domain conducted on project DE-FE0031583. Building upon the Design Basis completed during Phase I and in accordance with the Statement of Project Objectives (SOPO), the University of Kentucky (UK) Center for Applied Energy Research (CAER) (Recipient) along with team members has completed the Front End Engineering Design (FEED) for its advanced, versatile post-combustion CO 2 capture system (CCS) at the 10 MWe large pilot scale to be installed at the Wyoming (WY) Integrated Test Center (ITC), using a heat integrated process with split-rich fed, two-stage stripping and any advanced solvent to enhance the CO 2 absorber performance and lower the cost of CO 2 capture. The proposed project (Phases I-III) involves the design, fabrication, installation, testing and evaluation of a large pilot scale facility that will demonstrate the UK CAER transformative CCS integrated with an operating power plant. The work performed in Phase I, detailed in the Phase I Topical Report that was submitted in March 2019, included formation of a project team, securing the host site, and completing pre-FEED design basis, a cost estimation, a preliminary techno-economic analysis (TEA) and an environmental information volume (EIV). The work performed in Phase II, detailed in this Phase II Topical Report, includes completion of FEEDs, completion of a process risk analysis (PRA), obtaining necessary permits, updating the EIV and TEA, updating the cost and schedule estimate for the Phase III scope of work (SOW) and securing the necessary cost share. Updated information is provided on the current status of the UK CAER CCS technology and the project is ready to begin immediately detailed design, construction and operation of the proposed pilot.

20 FOSSIL-FUELED POWER PLANTS↗

VTR Casting Furnace Conceptual Design

This TEV describes the development of a conceptual design for a fuel casting system to be used in the development and demonstration of fuel designs for the new Versatile Test Reactor (VTR). This system will be installed in the Fuel Manufacturing Facility (FMF). The system will be in a shielded glovebox and will be used to melt fuel materials and injection cast these materials into fuel slugs, which will further be used to fabricate fuel elements for the VTR. This TEV covers only the injection casting system itself. Operations such as removing the castings from the injection molds, trimming of the castings, and installation of the castings into fuel element cladding are beyond the scope of the TEV. The conceptual design herein is principally concerned with the mechanical portion of the casting system and does not include details of the control or power supply systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cybersecurity Guide for Distributed Wind

Distributed wind sits at the intersection of grid-connected, off-grid and behind-the-meter cyber-physical electrical energy systems. The unique physical properties and communications requirements for distributed wind systems mean that there are unique cybersecurity considerations, but there is little to no existing guidance on best practices for cybersecurity. This document is intended to be a starting point for distributed wind stakeholders including manufacturers, installers and integrators, and operators (facility, aggregator, or utility). We discuss common distributed wind architectures and describe their role in the larger power system, pointing out some of the key connections to be aware of. Cybersecurity cannot exist in a vacuum, but rather must consider all the system and all its connections holistically. The role of distributed wind and the functions it can serve are described to gain understanding of the full range of capabilities. The purpose and application of relevant standards that may apply to certain distributed wind systems is presented. These standards may not apply to all installations, but even for systems that are not required to meet these standards they can be a good reference for best practices. A holistic threat perspective is used to describe the adversaries, threats, and potential impacts of cyberattacks, with special emphasis on what sets distributed wind systems apart from other distributed energy resources (DER). Finally, we present the recommendations for cybersecurity, both in terms of needs of the system and roles that specific stakeholders should fulfill. Distributed wind systems can come in a variety of architectures and applications, so there is no one-size-fits-all approach to cybersecurity. However, this document contains the relevant information for stakeholders to identify the cybersecurity needs of their system, refer to relevant standards, and apply best practices in a manner most consistent with their security and operational goals.

17 WIND ENERGY↗

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

Progress Report on Graphite-Salt Interaction Studies (FY21)

This report summarizes the activities performed in FY21 to investigate the interactions between nuclear graphite and molten salts, such as FLiNaK. First, building on last year’s achievements, the team improved the procedure for measurements on pressurized salt intrusion in nuclear graphite and performed new experiments at variable pressures with specimens of different sizes and shapes. Additionally, the team actively provided suggestions and comments for ASTM D8091, Standard Guide for Impregnation of Graphite with Molten Salts , which came up for periodic revision in 2021. Second, the team expanded its capabilities to further characterize salt-impregnated graphite by procuring and installing a laser-induced breakdown spectroscopy (LIBS) instrument capable of producing a 3D chemical composition of a surface and subsurface region of specimens. A methodology for accurately analyzing information was developed, and a manuscript was submitted for publication. The LIBS instrument sample cell is sealed in controlled inert atmosphere, which is an advantage for using humidity-sensitive samples and Be-contaminated samples. This aligns with the team’s effort to expand the capabilities of handling FLiBe and Becontaining materials in two newly installed glovebox units. Third, the team performed preliminary tribology tests for pebble graphite wear in contact with stainless steel in dry state and in molten salt at high temperature. These tests are needed to establish the baseline for the wear of pebble graphite by friction against metallic walls. The friction and wear of pebbles in the fluoride salt-cooled hightemperature reactor are expected to generate dust, which is a concern for other components’ properties and safe reactor operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Perovskite on Silicon Tandem Solar Cells

Since installing solar panels costs more than the panels themselves, it is critically important to improve the efficiency of the panels so that fewer panels need to be installed. More than 90% of all panels being manufactured are made with silicon solar cells. The most promising approach to reach 27% is to upgrade the panels by adding a second set of cells with a larger band gap that can harvest the higher energy photons in the visible spectrum and generate a higher voltage than silicon is capable of generating. Perovskite semiconductors are very promising for low-cost tandems because they have high band gaps, can be rapidly printed from solutions and have been used to make 25% efficient cells by themselves. If we show that it is possible to make stable tandems with 30% efficiency using materials that could be deposited at low cost and that the energy yield will not be compromised, then private companies would be able to raise the capital needed to manufacture this technology. The main metrics for this project are the power conversion efficiency of a lab-scale perovskite/silicon tandem and the ability to maintain a high power conversion efficiency in perovskite solar cells after accelerated operational stability testing under maximum power point at elevated temperature and 1 sun illumination. In short, this project demonstrates improvements to the perovskite absorber layer, contacts for the perovskite solar cell, and transparent oxide layers for window electrodes to achieve tandem efficiencies of 25% after one year and 27% after two years. By the end of the project, we identify strategies to further improve light management in the tandem devices and outline a pathway to reach 30%.In parallel, stability testing is conducted to evaluate said absorber and contact layers in the perovskite top cell, demonstrating 1000 hours of operation with less than 10% degradation at 1 sun. Our work on this project has made a leading impact on the development of perovskite/silicon tandems. The triple halide perovskite that we developed using iodide, bromide, and chloride and published in Science in March 2020 has received significant interest from other experts in the field at conferences. We took a silicon bottom cell with 21% efficiency, a technology that is responsible for a $30 billion market, and improved it by 30% relative. In addition, we have demonstrated impressive stability of our perovskite semitransparent top cells used in the tandems, showing for the first time packaged devices that pass a variety of IEC stability tests including damp heat, temperature cycling, and UV exposure tests.

14 SOLAR ENERGY↗

Potential Infrastructure Cost Savings at Hybrid Wind Plus Solar PV Plants

This report documents the creation of NREL's Balance of System model for Hybrid Renewable Energy Systems (HybridBOSSE). Balance of System (BOS) costs account for approximately 30% of the capital expenditure required to install a land-based wind plant, and as much as 40% of the cost of installing a solar PV plant. Hybrid Renewable Energy systems present an opportunity to combine balance of system components to achieve cost savings, and HybridBOSSE aims to provide a component-level model to determine the associated BOS costs in a hybrid renewable energy system. Prior BOS models for hybrid systems (at NREL and elsewhere) have relied on empirical curve fits of legacy industry data, limiting their utility and their predictive ability for new technology combinations and configurations, such as those found in Hybrid Plants. Hybrid plants at the utility scale have considerably more interest in the last number of years, with ever-growing capacities in the interconnection queues, and many large developers pivoting to only consider hybrid plants going forward. As these plants become a commercial reality, the need for a detailed analysis of costs in a hybrid plant to fully exploit the available cost savings grows. The tool developed and documented in this work, HybridBOSSE, provides an open-source, python-based method of assessing the costs in hybrid plants. This analysis capability unlocks greater certainty in hybrid plant costs, as well as the ability to examine scenarios of hybridization and glean combinations that offer the greatest flexibility and cost reduction.

14 SOLAR ENERGY↗

Biological Response Models: Predicting Injury and Mortality of Fish During Downstream Passage through Hydropower Facilities

This report describes the U.S. Department of Energy’s HydroPASSAGE project efforts to develop and collect biological response models for integration into the Biological Performance Assessment (BioPA) toolset and the Hydropower Biological Evaluation Toolset (HBET). These models help understand how fish are likely to respond during dam passage when exposed to hydraulic and physical stressors associated with turbines and other hydropower structures. When fish pass through hydropower facilities, they may encounter several stressors, of which the three most common are collision, rapid decompression, and fluid shear. Specialized equipment has been used to develop 99 biological response models for exposure to blade strike, rapid decompression, or fluid shear. The models were gathered from the literature or developed as part of this effort and include models for 31 different species of fish that have various predicted endpoints (i.e., injury or mortality). Among these models, considerable variation in susceptibility to the stressors has been observed from one species to another, and a species’ susceptibility to one stressor does not necessarily indicate similar susceptibility to another. Although several species have been examined, it is still unclear how many other species, which may have different morphological traits, may respond to these stressors, so further examination of the different species is needed. These models can and have been applied in several different cases, often using the BioPA toolset and HBET, to better understand the potential for injury and mortality that may occur during fish passage at hydropower facilities, including specific applications, such as turbine replacement, the installation of new turbines, or changing operations of currently installed turbines. As hydropower is continually developed to meet the electricity needs of society, tools such as HBET and BioPA, used with the integrated biological response models, will aid in the development of technologies and strategies that avoid, minimize, mitigate, or manage environmental effects.

13 HYDRO ENERGY↗

Cost targets to achieve commercially viable thermal storage in buildings

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. In this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. Lastly, the economic value implied by different types of deferred peak power plants were reviewed. The full value of TES to the entire society consists of value to the utility, OEMs, facility installers, and other stakeholders. This report focuses on the value to the utility with emphasis on the deferred capital of peak power plant. The value from the deferred capital of peak power plant is manifested to the customer in the form of demand reduction program and Time-of-Use utility rate program. In this report, an initial proxy of the value of TES is made by assuming the deferred capital cost of power plant is the full value to reduce peak demand. Three levels of financial value of TES systems were assessed. Two are currently available to some residential customers: (1) the benefit from TOU pricing alone and (2) the benefit from TOU pricing in combination with DR incentive programs. The third level was computed as the full cost of deferred capital cost of peaking power plants. This represents the potential value that could be gained by the utilities or conceivably be offered to consumers.

25 ENERGY STORAGE↗

Rooftop Solar PV Quality and Safety in Developing Countries - Key Issues and Potential Solutions

To scale solar photovoltaic (PV) deployment in developing countries, the technology must be safe and reliable, meeting both customer and utility expectations. However, challenges exist in achieving these goals. Because PV systems are novel and complex, the majority of consumers are unable to distinguish between low- and high-quality systems; many may invest based on price alone. Suboptimal PV system performance and safety incidents can have downstream impacts on the solar industry and customer adoption because of unmet expectations and negative publicity. Rooftop solar system components vary in quality, and inadequate training could lead to poor installation practices. And even if inspection checklists, certification procedures, and standards are available, they may not be widely used in countries if they are not mandatory, the workforce is not aware of them, or installers lack the technical capacity to comply. Despite the numerous solar quality and safety challenges developing countries may face, lessons learned and best practices from around the world can address them.

14 SOLAR ENERGY↗

Experimental Plan for the Vermiculite Study

Homes in which vermiculite, which can contain asbestos, is present are often deferred under the DOE Weatherization Assistance Program (WAP) because of uncertainty in how to safely weatherize such homes from a client and worker perspective and the potential costs associated with alternative approaches. Recognizing this situation, the Department of Energy (DOE) tasked the Oak Ridge National Laboratory (ORNL) to perform a research project that scientifically identifies the asbestos exposure risks in weatherizing homes with existing vermiculite insulation. Current approaches being used by Grantees and Subgrantees to weatherize homes with existing vermiculite insulation were identified as part of the development of this experimental plan based on a review of Grantee Health and Safety Plans and communications with weatherization program staff from seven states. Other than deferral, these approaches include the following:1.) Abating (i.e., removing) the existing vermiculite using funding sources other than WAP (e.g., state funds, utility funds, the Zonolite Attic Insulation Trust Fund, and possibly homeowner contributions) because abatement is not allowed using WAP funds per Weatherization Program Notice (WPN) 17-7. 2.) Weatherizing the house as normal after testing reveals that the vermiculite contains less than 1% asbestos. 3.) Avoiding areas of the house where vermiculite is installed and weatherizing the remaining areas of the house as normal. 4.) Encapsulating the existing vermiculite insulation in an attic by blowing cellulose or other insulation over it. 5.) Weatherizing the areas of the house where vermiculite is installed using unique/alternative approaches developed specifically for that house. Blower door testing is also impacted by the presence of vermiculite due to the concern of bringing asbestos fibers into the space. Some states address this by performing pressurized blower door tests, whereas other states prohibit blower door testing entirely when vermiculite is present. This research project will focus on gathering data on home occupant and weatherization worker exposures to asbestos before, during, and/or after the weatherization of the homes containing vermiculite insulation using five of the six approaches identified above. Abatement of the existing vermiculite insulation will not be studied because it is not allowed using WAP funding per WPN 17-7 and, thus, is not a sustainable approach for WAP.

36 MATERIALS SCIENCE↗

AMS Thermal Cooling System (Final Report)

The Alpha Magnetic Spectrometer (AMS) is a U.S. Department of Energy-sponsored particle physics experiment on the International Space Station (ISS). AMS is exploring some of the most fundamental questions in physics such as understanding dark matter, antimatter, the origin of cosmic rays and their characteristics as well as searching for new physics phenomena in the universe. It has recorded more than 200 billion cosmic rays since its launch in May 2011. Over time, anomalies associated with the dedicated cooling system of the AMS Silicon Tracker system were observed, leading to the discovery of progressive deterioration in the functioning of the cooling system's four redundant pumps. The Tracker is crucial to the scientific mission of AMS, as it is the only subdetector that can distinguish matter from antimatter. This report details the successful program of work for the installation of the Upgraded Tracker Thermal Pump System (UTTPS) on AMS. This program included: identifying the root cause of deterioration in the original pumps; design, production, testing, and integration of the new UTTPS cooling system; launch of the UTTPS to ISS; installation of the UTTPS in AMS across a series of four complex extra-vehicular activities (EVAs); and establishment of a dedicated Flight Simulator Laboratory to test the performance of the UTTPS under various thermal conditions. This program was critical to the success of the AMS experiment, and its successful completion will enable AMS to continue taking data through 2030.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗