Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Human Errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

In vivo 3D modeling of the femoropopliteal artery in human subjects based on x-ray angiography: Methodology and validation

Endovascular revascularization of the femoropopliteal (FP) artery has been limited by high rates of restenosis and stent fracture. The unique physical forces that are applied to the FP artery during leg movement have been implicated in these phenomena. The foundation for measuring the effects of physical forces on the FP artery in a clinically relevant environment is based on the ability to develop 3D models of this vessel in different leg positions in vivo in patients with peripheral arterial disease (PAD). By acquiring paired angiographic images of the FP artery, and using angiography-based 3D modeling algorithms previously validated in the coronary arteries, the authors generated 3D models of ten FP arteries in nine patients with PAD with the lower extremity in straight leg (SL) and crossed leg (CL) positions. Due to the length of the FP artery, overlapping paired angiographic images of the entire FP artery were required to image the entire vessel, which necessitated the development of a novel fusion process in order to generate a 3D model of the entire FP artery. The methodology of angiographic acquisition and 3D model generation of the FP artery is described. In a subset of patients, a third angiographic view (i.e., validation view) was acquired in addition to the standard paired views for the purpose of validating the 3D modeling process. The mean root-mean-square (rms) error of the point-to-point distances between the centerline of the main FP artery from the 2D validation view and the centerline from the 3D model placed in the validation view for the SL and CL positions were 0.93{+-}0.19 mm and 1.12{+-}0.25 mm, respectively. Similarly, the mean rms error of the same comparison for the main FP artery and sidebranches for the SL and CL positions were 1.09{+-}0.38 mm and 1.21{+-}0.25 mm, respectively. A separate validation of the novel fusion process was performed by comparing the 3D model of the FP artery derived from fusion of 3D models of adjacent FP segments with the 2D validation view incorporating the region of fusion. The mean rms error of vessel centerline points of the main FP artery, the main FP artery plus directly connected sidebranches, and the mean rms error of upstream, downstream, and sidebranch directional vectors at bifurcation points in the overlap region were 1.41{+-}0.79 mm, 2.13{+-}1.12 mm, 3.16{+-}3.72 deg., 3.60{+-}5.39 deg., and 8.68{+-}8.42 deg. in the SL position, respectively, and 1.29{+-}0.35 mm, 1.61{+-}0.78 mm, 4.68{+-}4.08 deg., 3.41{+-}2.23 deg., and 5.52{+-}4.41 deg. in the CL position, respectively. Inter- and intraobserver variability in the generation of 3D models of individual FP segments and the fusion of overlapping FP segments were assessed. The mean rms errors between the centerlines of nine 3D models of individual FP segments generated by two independent observers, and repeated measurement by the same observer were 2.78{+-}1.26 mm and 3.50{+-}1.15 mm, respectively. The mean rms errors between the centerline of four 3D models of fused overlapping FP segments generated by two independent observers, and repeated measurement by the same observer were 4.99{+-}0.99 mm and 5.98{+-}1.22 mm, respectively. This study documents the ability to generate 3D models of the entire FP artery in vivo in patients with PAD in both SL and CL positions using routine angiography, and validates the methodologies used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CONSTRUCTION OF A CALIBRATED PROBABILISTIC CLASSIFICATION CATALOG: APPLICATION TO 50k VARIABLE SOURCES IN THE ALL-SKY AUTOMATED SURVEY

With growing data volumes from synoptic surveys, astronomers necessarily must become more abstracted from the discovery and introspection processes. Given the scarcity of follow-up resources, there is a particularly sharp onus on the frameworks that replace these human roles to provide accurate and well-calibrated probabilistic classification catalogs. Such catalogs inform the subsequent follow-up, allowing consumers to optimize the selection of specific sources for further study and permitting rigorous treatment of classification purities and efficiencies for population studies. Here, we describe a process to produce a probabilistic classification catalog of variability with machine learning from a multi-epoch photometric survey. In addition to producing accurate classifications, we show how to estimate calibrated class probabilities and motivate the importance of probability calibration. We also introduce a methodology for feature-based anomaly detection, which allows discovery of objects in the survey that do not fit within the predefined class taxonomy. Finally, we apply these methods to sources observed by the All-Sky Automated Survey (ASAS), and release the Machine-learned ASAS Classification Catalog (MACC), a 28 class probabilistic classification catalog of 50,124 ASAS sources in the ASAS Catalog of Variable Stars. We estimate that MACC achieves a sub-20% classification error rate and demonstrate that the class posterior probabilities are reasonably calibrated. MACC classifications compare favorably to the classifications of several previous domain-specific ASAS papers and to the ASAS Catalog of Variable Stars, which had classified only 24% of those sources into one of 12 science classes.

79 ASTRONOMY AND ASTROPHYSICS↗

In-Situ Navigation and Timing Services for a Human Mars Landing Site Part 2: System Design and Simulations

In a previous paper, we described the system concept of a proposed Mars Regional Navigation Satellite System (MRNSS) that is built upon a number of notional Mars orbiting and surface missions in the human exploration era of Mars. We assume two areostationary Mars relay orbiters that have continuous line-of-sight visibility with the Mars landing site, a Deep Space Habitat (DSH) in an inclined 48-hour circular orbit, and a surface communication lander that could serve as the reference point. These orbiting and surface infrastructure elements broadcast GPS-like ranging signals and other ephemeris information to the mission users. With one or more additional orbiters in areosynchronous orbits that trace around a figure-8 path, a regional navigation satellite system can be realized that provides in-situ course absolute localization and precision relative localization and timing services to the users in the vicinity of a Mars landing site. We also introduced a new geometric trilateration method that simultaneously performs absolute positioning and relative positioning. The relative position is derived from a “differencing” function of two raw-range measurements between a known reference point and of the target from a navigation satellite, thereby eliminating most of the common errors like atmospheric delays, ephemeris errors, and instrument delays in real-time. In the Mars environment, this “error-cancellation” function greatly reduces the need to perform extensive orbit determination (OD) of the navigation satellites like the Earth’s GPS, and only requires occasional tracks from the Earth’s large-aperture deep space antennas to perform OD’s. In this paper, we provide detailed simulations on both the absolute positioning scheme and the relative positioning scheme, and show that the relative positioning scheme provides 200 – 400 times improvement in localization accuracy. On the ground side, we discuss new approaches that simultaneously perform 2-way Doppler/ranging, and re-introduce the method of Same Beam Interferometry (SBI) for the Mars navigation orbiters. This helps to further reduce the tracking burden of the ground antennas required to support the OD of the Mars orbiters, making the concept of MRNSS more realizable.

Lightsey, Glenn↗

Genome Project Standards in a New Era of Sequencing

For over a decade, genome 43 sequences have adhered to only two standards that are relied on for purposes of sequence analysis by interested third parties (1, 2). However, ongoing developments in revolutionary sequencing technologies have resulted in a redefinition of traditional whole genome sequencing that requires a careful reevaluation of such standards. With commercially available 454 pyrosequencing (followed by Illumina, SOLiD, and now Helicos), there has been an explosion of genomes sequenced under the moniker 'draft', however these can be very poor quality genomes (due to inherent errors in the sequencing technologies, and the inability of assembly programs to fully address these errors). Further, one can only infer that such draft genomes may be of poor quality by navigating through the databases to find the number and type of reads deposited in sequence trace repositories (and not all genomes have this available), or to identify the number of contigs or genome fragments deposited to the database. The difficulty in assessing the quality of such deposited genomes has created some havoc for genome analysis pipelines and contributed to many wasted hours of (mis)interpretation. These same novel sequencing technologies have also brought an exponential leap in raw sequencing capability, and at greatly reduced prices that have further skewed the time- and cost-ratios of draft data generation versus the painstaking process of improving and finishing a genome. The resulting effect is an ever-widening gap between drafted and finished genomes that only promises to continue (Figure 1), hence there is an urgent need to distinguish good and poor datasets. The sequencing institutes in the authorship, along with the NIH's Human Microbiome Project Jumpstart Consortium (3), strongly believe that a new set of standards is required for genome sequences. The following represents a set of six community-defined categories of genome sequence standards that better reflect the quality of the genome sequence, based on our collective understanding of the different technologies, available assemblers, and the varied efforts to improve upon drafted genomes. Due to the increasingly rapid pace of genomics we avoided the use of rigid numerical thresholds in our definitions to take into account the types of products achieved by any combination of technology, chemistry, assembler, or improvement/finishing process.

59 BASIC BIOLOGICAL SCIENCES↗

A stochastic differential equation model of diurnal cortisol patterns

Circadian modulation of episodic bursts is recognized as the normal physiological pattern of diurnal variation in plasma cortisol levels. The primary physiological factors underlying these diurnal patterns are the ultradian timing of secretory events, circadian modulation of the amplitude of secretory events, infusion of the hormone from the adrenal gland into the plasma, and clearance of the hormone from the plasma by the liver. Each measured plasma cortisol level has an error arising from the cortisol immunoassay. We demonstrate that all of these three physiological principles can be succinctly summarized in a single stochastic differential equation plus measurement error model and show that physiologically consistent ranges of the model parameters can be determined from published reports. We summarize the model parameters in terms of the multivariate Gaussian probability density and establish the plausibility of the model with a series of simulation studies. Our framework makes possible a sensitivity analysis in which all model parameters are allowed to vary simultaneously. The model offers an approach for simultaneously representing cortisol's ultradian, circadian, and kinetic properties. Our modeling paradigm provides a framework for simulation studies and data analysis that should be readily adaptable to the analysis of other endocrine hormone systems.

NASA Discipline Space Human Factors↗

Prospective memory in dynamic environments: effects of load, delay, and phonological rehearsal

A new paradigm was developed to examine prospective memory performance in a visual-spatial task that resembles some aspects of the work of air traffic controllers. Two experiments examined the role of workload (number of aeroplanes that participants directed), delay (between receipt of prospective instructions and execution), and phonological rehearsal. High workload increased prospective memory errors but increasing delay from 1-3 or 5 minutes had no effect. Shadowing aurally presented text reduced prospective memory performance, presumably because it prevented verbal rehearsal of the prospective instructions. However, performance on the foreground task of directing aeroplanes to routine destinations was affected only by workload and not by opportunity for rehearsal. Our results suggest that ability to maintain performance on a routine foreground task while performing a secondary task--perhaps analogous to conversation--does not predict ability to retrieve a prospective intention to deviate from the routine.

Aerospace Medicine↗

Determining blood and plasma volumes using bioelectrical response spectroscopy

We hypothesized that an electric field (inductance) produced by charged blood components passing through the many branches of arteries and veins could assess total blood volume (TBV) or plasma volume (PV). Individual (N = 29) electrical circuits (inductors, two resistors, and a capacitor) were determined from bioelectrical response spectroscopy (BERS) using a Hewlett Packard 4284A Precision LCR Meter. Inductance, capacitance, and resistance from the circuits of 19 subjects modeled TBV (sum of PV and computed red cell volume) and PV (based on 125I-albumin). Each model (N = 10, cross validation group) had good validity based on 1) mean differences (-2.3 to 1.5%) between the methods that were not significant and less than the propagated errors (+/- 5.2% for TBV and PV), 2) high correlations (r > 0.92) with low SEE (< 7.7%) between dilution and BERS assessments, and 3) Bland-Altman pairwise comparisons that indicated "clinical equivalency" between the methods. Given the limitation of this study (10 validity subjects), we concluded that BERS models accurately assessed TBV and PV. Further evaluations of the models' validities are needed before they are used in clinical or research settings.

NASA Discipline Number 00-00↗

Human Factors Assessment and Redesign of the ISS Respiratory Support Pack (RSP) Cue Card

The Respiratory Support Pack (RSP) is a medical pack onboard the International Space Station (ISS) that contains much of the necessary equipment for providing aid to a conscious or unconscious crewmember in respiratory distress. Inside the RSP lid pocket is a 5.5 by 11 inch paper procedural cue card, which is used by a Crew Medical Officer (CMO) to set up the equipment and deliver oxygen to a crewmember. In training, crewmembers expressed concerns about the readability and usability of the cue card; consequently, updating the cue card was prioritized as an activity to be completed. The Usability Testing and Analysis Facility at the Johnson Space Center (JSC) evaluated the original layout of the cue card, and proposed several new cue card designs based on human factors principles. The approach taken for the assessment was an iterative process. First, in order to completely understand the issues with the RSP cue card, crewmember post training comments regarding the RSP cue card were taken into consideration. Over the course of the iterative process, the procedural information was reorganized into a linear flow after the removal of irrelevant (non-emergency) content. Pictures, color coding, and borders were added to highlight key components in the RSP to aid in quickly identifying those components. There were minimal changes to the actual text content. Three studies were conducted using non-medically trained JSC personnel (total of 34 participants). Non-medically trained personnel participated in order to approximate a scenario of limited CMO exposure to the RSP equipment and training (which can occur six months prior to the mission). In each study, participants were asked to perform two respiratory distress scenarios using one of the cue card designs to simulate resuscitation (using a mannequin along with the hardware). Procedure completion time, errors, and subjective ratings were recorded. The last iteration of the cue card featured a schematic of the RSP, colors, borders, and simplification of the flow of information. The time to complete the RSP procedure was reduced by approximately three minutes with the new design. In an emergency situation, three minutes significantly increases the probability of saving a life. In addition, participants showed the highest preference for this design. The results of the studies and the new design were presented to a focus group of astronauts, flight surgeons, medical trainers, and procedures personnel. The final cue card was presented to a medical control board and approved for flight. The revised RSP cue card is currently onboard ISS.

Byrne, Vicky↗

Performance Impacts to the NASA Artemis II Trajectory Correction Burn Placement

As NASA embarks to return humans to the lunar vicinity with the upcoming Artemis II mission, the selected free return trajectory taking the crew to the Moon in the Orion spacecraft is impacted by the execution of small trajectory correction burns to ensure the spacecraft stays on course for a successful return to Earth. The placement of these nominally zero translational maneuvers must account for the crew schedule, navigation tracking constraints, spacecraft venting, thermal and communication requirements, and a host of other programmatic factors. Understanding the influence the placement of these periodic burn corrections have on the integrated GN\&C performance can provide valuable insight to mission controllers and trajectory planning processes to untangle the complex trade space considered for both baseline and contingency scenarios. This sensitivity information can also be utilized to facilitate the optimized placement of these burns. This paper utilizes several techniques to systematically generate the performance impacts to the NASA Artemis II trajectory correction burn placement and demonstrate how to derive optimized locations that make the system robust to crew activity, maneuver execution errors, navigation uncertainty, orbit insertion errors, disturbance accelerations, and other system limitations.

GN&C↗

Time-on-task decrements in "steer clear" performance of patients with sleep apnea and narcolepsy

Loss of attention with time-on-task reflects the increasing instability of the waking state during performance in experimentally induced sleepiness. To determine whether patients with disorders of excessive sleepiness also displayed time-on-task decrements indicative of wake state instability, visual sustained attention performance on "Steer Clear," a computerized simple RT driving simulation task, was compared among 31 patients with untreated sleep apnea, 16 patients with narcolepsy, and 14 healthy control subjects. Vigilance decrement functions were generated by analyzing the number of collisions in each of six four-minute periods of Steer Clear task performance in a mixed-model analysis of variance and linear regression equations. As expected, patients had more Steer Clear collisions than control subjects (p=0.006). However, the inter-subject variability in errors among the narcoleptic patients was four-fold that of the apnea patients, and 100-fold that of the controls volunteers; the variance in errors among untreated apnea patients was 27-times that of controls. The results of transformed collision data revealed main effects for group (p=0.006), time-on-task (p=0.001), and a significant interaction (p=0.022). Control subjects showed no clear evidence of increasing collision errors with time-on-task (adjusted R2=0.22), while apnea patients showed a trend toward vigilance decrement (adjusted R2=0.42, p=0.097), and narcolepsy patients evidenced a robust linear vigilance decrement (adjusted R2=0.87, p=0.004). The association of disorders of excessive somnolence with escalating time-on-task decrements makes it imperative that when assessment of neurobehavioral performance is conducted in patients, it involves task durations and analyses that will evaluate the underlying vulnerability of potentially sleepy patients to decrements over time in tasks that require sustained attention and timely responses, both of which are key components in safe driving performance.

NASA Discipline Space Human Factors↗

Southern Idaho Health & Air Quality II: Evaluating Atmospheric Mixing Height Estimations in the Western United States

Wildfires in the western United States have caused immense infrastructure damage and loss of human life in recent years. Wildfire smoke, which travels far from its original source, is also harmful to human health. Mixing height, which acts as a lid and prevents smoke from rising above a certain altitude in the lower troposphere, is a critical input in smoke dispersion and air quality models used by agencies that monitor wildfires. These models, coupled with forecaster expertise, are also used to decide when it is safe to execute a prescribed burn. The DEVELOPID team partnered with the National Weather Service (NWS) Fire Weather Program, Bureau of Land Management (BLM), National Interagency Fire Center (NIFC), and National Park Service (NPS) Fire Management Program Center (FMPC) to help improve reliability and confidence in mixing height estimations, and therefore the burn prescription decision-making process. To that end, the team developed a toolbox for measuring smoke-related aerosol mixing heights using Cloud-Aerosol LiDAR and Infrared Pathfinder Satellite Observations (CALIPSO) Vertical Feature Mask granules. CALIPSO mixing heights and NWS estimations covaried significantly and positively. However, substantial disagreement between the methods stymied the team’s attempts to quantify systematic bias in a meaningful way. The relative error between the methods was especially large at low mixing heights, which suggests that this method of validation may only be suitable at higher altitudes.

Dean Berkowitz↗

An Orbit Determination Comparison Study and Demonstration for Rendezvous and Docking in a Near Rectilinear Halo Orbit from the Lunar Surface

For the upcoming NASA Artemis III mission and those that follow, both the Human Landing System (HLS) and Orion programs are invested in understanding the impacts of ground tracking performance in supporting rendezvous and docking in a Near Rectilinear Halo Orbit (NRHO). Several critical questions must be answered to ensure mission success and crew safety and an assortment of analysis tools are being incorporated to address them. Two of these tools, LINCOV and MONTE, are currently providing program decision making results through HLS Insight, HLS NASA-collaborations, and Orion/Gateway cross-program analysis. To ensure consistency in the orbit determination performance, a comparison trade-study is performed using a low-lunar orbit to NRHO rendezvous scenario anticipated for the upcoming Artemis missions. An overview of the two analysis tools is provided along with a detailed step-by-step evaluation of the core capabilities and models related to the orbit determination process. This incremental comparison effort reveals both tools produce consistent solutions for the criteria investigated to within 0.3\% difference in the absolute position state estimate at key decision making epochs with all errors sources activated.

orbit determination↗

TH-C-BRD-05: Reducing Proton Beam Range Uncertainty with Patient-Specific CT HU to RSP Calibrations Based On Single-Detector Proton Radiography

Purpose: Beam range uncertainty in proton treatment comes primarily from converting the patient's X-ray CT (xCT) dataset to relative stopping power (RSP). Current practices use a single curve for this conversion, produced by a stoichiometric calibration based on tissue composition data for average, healthy, adult humans, but not for the individual in question. Proton radiographs produce water-equivalent path length (WEPL) maps, dependent on the RSP of tissues within the specific patient. This work investigates the use of such WEPL maps to optimize patient-specific calibration curves for reducing beam range uncertainty. Methods: The optimization procedure works on the principle of minimizing the difference between the known WEPL map, obtained from a proton radiograph, and a digitally-reconstructed WEPL map (DRWM) through an RSP dataset, by altering the calibration curve that is used to convert the xCT into an RSP dataset. DRWMs were produced with Plastimatch, an in-house developed software, and an optimization procedure was implemented in Matlab. Tests were made on a range of systems including simulated datasets with computed WEPL maps and phantoms (anthropomorphic and real biological tissue) with WEPL maps measured by single detector proton radiography. Results: For the simulated datasets, the optimizer showed excellent results. It was able to either completely eradicate or significantly reduce the root-mean-square-error (RMSE) in the WEPL for the homogeneous phantoms (to zero for individual materials or from 1.5% to 0.2% for the simultaneous optimization of multiple materials). For the heterogeneous phantom the RMSE was reduced from 1.9% to 0.3%. Conclusion: An optimization procedure has been designed to produce patient-specific calibration curves. Test results on a range of systems with different complexities and sizes have been promising for accurate beam range control in patients. This project was funded equally by the Engineering and Physical Sciences Research Council (UK) and Ion Beam Applications (Louvain-La-Neuve, Belgium)

07 ISOTOPE AND RADIATION SOURCES↗

Evaluating simplifications of subsurface process representations for field-scale permafrost hydrology models

Abstract. Permafrost degradation within a warming climate poses a significant environmental threat through both the permafrost carbon feedback and damage to human communities and infrastructure. Understanding this threat relies on better understanding and numerical representation of thermo-hydrological permafrost processes and the subsequent accurate prediction of permafrost dynamics. All models include simplified assumptions, implying a tradeoff between model complexity and prediction accuracy. The main purpose of this work is to investigate this tradeoff when applying the following commonly made assumptions: (1) assuming equal density of ice and liquid water in frozen soil, (2) neglecting the effect of cryosuction in unsaturated freezing soil, and (3) neglecting advective heat transport during soil freezing and thaw. This study designed a set of 62 numerical experiments using the Advanced Terrestrial Simulator (ATS v1.2) to evaluate the effects of these choices on permafrost hydrological outputs, including both integrated and pointwise quantities. Simulations were conducted under different climate conditions and soil properties from three different sites in both column- and hillslope-scale configurations. Results showed that amongst the three physical assumptions, soil cryosuction is the most crucial yet commonly ignored process. Neglecting cryosuction, on average, can cause 10 %–20 % error in predicting evaporation, 50 %–60 % error in discharge, 10 %–30 % error in thaw depth, and 10 %–30 % error in soil temperature at 1 m beneath the surface. The prediction error for subsurface temperature and water saturation is more obvious at hillslope scales due to the presence of lateral flux. By comparison, using equal ice–liquid density has a minor impact on most hydrological metrics of interest but significantly affects soil water saturation with an averaged 5 %–15 % error. Neglecting advective heat transport presents the least error, 5 % or even much lower, in most metrics of interest for a large-scale Arctic tundra system without apparent influence caused by localized groundwater flow, and it can decrease the simulation time at hillslope scales by 40 %–80 %. By challenging these commonly made assumptions, this work provides permafrost hydrology scientists an important context for understanding the underlying physical processes, including allowing modelers to better choose the appropriate process representation for a given modeling experiment.

54 ENVIRONMENTAL SCIENCES↗

Navigation Strategy for the Mars 2001 Lander Mission

The Mars Surveyor Program (MSP) is an ongoing series of missions designed to robotically study, map and search for signs of life on the planet Mars. The MSP 2001 project will advance the effort by sending an orbiter, a lander and a rover to the red planet in the 2001 opportunity. Each vehicle will carry a science payload that will Investigate the Martian environment on both a global and on a local scale. Although this mission will not directly search for signs of life, or cache samples to be returned to Earth, it will demonstrate certain enabling technologies that will be utilized by the future Mars Sample Return missions. One technology that is needed for the Sample Return mission is the capability to place a vehicle on the surface within several kilometers of the targeted landing site. The MSP'01 Lander will take the first major step towards this type of precision landing at Mars. Significant reduction of the landed footprint will be achieved through two technology advances. The first, and most dramatic, is hypersonic aeromaneuvering; the second is improved approach navigation. As a result, the guided entry will produce in a footprint that is only tens of kilometers, which is an order of magnitude improvement over the Pathfinder and Mars Polar Lander ballistic entries. This reduction will significantly enhance scientific return by enabling the potential selection of otherwise unreachable landing sites with unique geologic interest and public appeal. A landed footprint reduction from hundreds to tens of kilometers is also a milestone on the path towards human exploration of Mars, where the desire is to place multiple vehicles within several hundred meters of the planned landing site. Hypersonic aeromaneuvering is an extension of the atmospheric flight goals of the previous landed missions, Pathfinder and Mars Polar Lander (MPL), that utilizes aerodynamic lift and an autonomous guidance algorithm while in the upper atmosphere. The onboard guidance algorithm will control the direction of the lift vector, via bank angle modulation, to keep the vehicle on the desired trajectory. While numerous autonomous guidance algorithms have been developed for use during hypersonic flight at Earth, this will be the first flight of an autonomously directed lifting entry vehicle at Mars. However, without sufficient control and knowledge of the atmospheric entry conditions, the guidance algorithm will not perform effectively. The goal of the interplanetary navigation strategy is to deliver the spacecraft to the desired entry condition with sufficient accuracy and knowledge to enable satisfactory guidance algorithm performance. Specifically, the entry flight path angle must not exceed 0.27 deg. to a 3 sigma confidence level. Entry errors will contribute directly to the size of the landed footprint and the most significant component is entry flight path angle. The size of the entry corridor is limited on the shallow side by integrated heating constraints, and on the steep side by deceleration (g-load) and terminal descent propellant. In order to meet this tight constraint it is necessary to place a targeting maneuver seven hours prior to the time of entry. At this time the trajectory knowledge will be quite accurate, and the effects of maneuver execution errors will be small. The drawback is that entry accuracy is dependent on the success of this final late maneuver. Because propulsive maneuvers are critical events, it is desirable to minimize their occurrence and provide the flight team with as much response time as possible in the event of a spacecraft fault. A mission critical maneuver at Entry - 7 hours does not provide much fault tolerance, and it is desirable to provide a strategy that minimizes reliance on this maneuver. This paper will focus on the Improvements in interplanetary navigation that will decrease entry errors and will reduce the landed footprint, even in the absence of aeromaneuvering. The easiest to take advantage of are Improvements In the knowledge of the Mars ephemeris and gravity field due to the MGS and MSP'98 missions. Improvements In data collection and reduction techniques such as "precislon ranging' and near-simultaneous tracking will also be utilized. In addition to precise trajectory control, a robust strategy for communications and flight operations must also be demonstrated. The result Is a navigation and communications strategy on approach that utilizes optimal maneuver placement to take advantage of trajectory knowledge, minimizes risk for the flight operations team, is responsive to spacecraft hardware limitations, and achieves the entry corridor. The MSP2001 mission Is managed at JPL under the auspices of the Mars Exploration Directorate. The spacecraft flight elements are built and managed by Lockheed-Martin Astronautics in Denver, Colorado.

Mase, Robert A.↗

Classification of Malaysia aromatic rice using multivariate statistical analysis

Aromatic rice (Oryza sativa L.) is considered as the best quality premium rice. The varieties are preferred by consumers because of its preference criteria such as shape, colour, distinctive aroma and flavour. The price of aromatic rice is higher than ordinary rice due to its special needed growth condition for instance specific climate and soil. Presently, the aromatic rice quality is identified by using its key elements and isotopic variables. The rice can also be classified via Gas Chromatography Mass Spectrometry (GC-MS) or human sensory panels. However, the uses of human sensory panels have significant drawbacks such as lengthy training time, and prone to fatigue as the number of sample increased and inconsistent. The GC–MS analysis techniques on the other hand, require detailed procedures, lengthy analysis and quite costly. This paper presents the application of in-house developed Electronic Nose (e-nose) to classify new aromatic rice varieties. The e-nose is used to classify the variety of aromatic rice based on the samples odour. The samples were taken from the variety of rice. The instrument utilizes multivariate statistical data analysis, including Principal Component Analysis (PCA), Linear Discriminant Analysis (LDA) and K-Nearest Neighbours (KNN) to classify the unknown rice samples. The Leave-One-Out (LOO) validation approach is applied to evaluate the ability of KNN to perform recognition and classification of the unspecified samples. The visual observation of the PCA and LDA plots of the rice proves that the instrument was able to separate the samples into different clusters accordingly. The results of LDA and KNN with low misclassification error support the above findings and we may conclude that the e-nose is successfully applied to the classification of the aromatic rice varieties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Sheaf Theoretical Approach to Uncertainty Quantification of Heterogeneous Geolocation Information

Integration of multiple, heterogeneous sensors is a challenging problem across a range of applications. Prominent among these are multi-target tracking, where one must combine observations from different sensor types in a meaningful and efficient way to track multiple targets. Because different sensors have differing error models, we seek a theoretically justified quantification of the agreement among ensembles of sensors, both overall for a sensor collection, and also at a fine-grained level specifying pairwise and multi-way interactions among sensors. We demonstrate that the theory of mathematical sheaves provides a unified answer to this need, supporting both quantitative and qualitative data. Furthermore, the theory provides algorithms to globalize data across the network of deployed sensors, and to diagnose issues when the data do not globalize cleanly. We demonstrate and illustrate the utility of sheaf-based tracking models based on experimental data of a wild population of black bears in Asheville, North Carolina. A measurement model involving four sensors deployed among the bears and the team of scientists charged with tracking their location is deployed. This provides a sheaf-based integration model which is small enough to fully interpret, but of sufficient complexity to demonstrate the sheaf’s ability to recover a holistic picture of the locations and behaviors of both individual bears and the bear-human tracking system. A statistical approach was developed in parallel for comparison, a dynamic linear model which was estimated using a Kalman filter. This approach also recovered bear and human locations and sensor accuracies. When the observations are normalized into a common coordinate system, the structure of the dynamic linear observation model recapitulates the structure of the sheaf model, demonstrating the canonicity of the sheaf-based approach. However, when the observations are not so normalized, the sheaf model still remains valid.

97 MATHEMATICS AND COMPUTING↗

Predicting Team Functioning in Long Term Space Missions Using Acoustic and Linguistic Measures

Maintaining optimal team functioning is critical for long-duration space exploration missions, yet traditional monitoring methods, such as self-reports and wearable sensors, often impose operational burdens or suffer from bias. This paper investigates a non-intrusive speech-based artificial intelligence (AI) framework to predict degradations in team functioning using data from the Human Exploration Research Analog (HERA) of the U.S. National Aeronautics and Space Administration (NASA). Using acoustic features, linguistic descriptors, and semantic embeddings, we evaluate static non-linear and temporal machine learning models to predict both objective (task accuracy) and subjective (self-reported efficacy and cohesion) team functioning outcomes. Results indicate that temporal models outperform static approaches, with prediction of objective task accuracy in Team Interaction Battery (TIB) improving from near chance to 71%. Self-reported outcomes, including team efficacy and cohesion, are predicted more reliably than task performance, achieving balanced accuracies of up to 85.56% and 78.12%, respectively, and are found to be most strongly associated with acoustic features. In a second interdependent task, the MMSEV–EVA, accuracies of up to 78% are achieved using temporal models with acoustic features. Furthermore, incorporating just 1–2 days of team-specific historical data systematically improved performance, and acoustic markers from informal pre-task interactions provided modest predictive gains. Finally, while automated preprocessing yielded viable accuracy, humancorrected data provided moderate performance gains, though transcription error rates did not significantly correlate with model performance. These findings highlight the potential of speech as a passive, high-fidelity monitoring tool for autonomous habitats.

Temporal modeling↗