Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Comparative Cooling Season Performance of Air Distribution Systems in Multistory Townhomes

IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore the small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements. Ultimately, the builder decided that adoption of these practices would be too disruptive midstream in the construction cycle. However, the townhomes met the ENERGY STAR Version 3.0 program requirements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Cooling Season Performance of Air Distribution Systems in Multistory Townhomes

IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore the small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Critical Literature Review of Defrost Technologies for Heat Pumps and Refrigeration Systems

When the operating conditions are extremely cold and humid and the surface temperature of the heat exchanger well below the freezing point (lower than the dew point temperature of the air) moisture from the air stream will freeze on the surface after condensation and the frost will start growing. The frost growth degrades the performance of the system considerably. It hinders the airflow and increases the pressure drop through the coil which means more fan power is requires for to maintain the desired flow rate. With reduced flow rate due to the increase of pressure drop, system’s capacity drops rapidly. In the case of heat pump the capacity of the evaporator decreases due to the airflow drop, which reduces the overall heating capacity and coefficient of performance of the heat pump. Additionally, the frost layer increases the thermal resistance to the heat transfer between the air and refrigerant. The reduction in airflow and increased thermal resistance reduces the heat energy extracted by the evaporator and decreases the heat pump capacity and efficiency. Similar process is observed for the cooling coils of commercial refrigeration system where the frost growth can dramatically reduce the system capacity. Once the performance reaches its minimum acceptable stage, a defrost process is introduced to remove the frost layer and to achieve the performance at the start of the cycle. The frost defrost process is repeated continuously. Overall the frost growth is highly undesired phenomena which can cause considerable reduction in performance of the system.

42 ENGINEERING↗

Scoping Study of Integrated Geothermal CO 2 Heat Pump and Water Well System in Cold Climate Region (CRADA Final Report)

This study evaluates the feasibility of using ground-source heat pumps (GSHPs) integrated with water wells for residential heating demands in cold regions of the United States. Four different heat pump systems were evaluated and compared: a CO 2 air-source heat pump (ASHP), a R-410A ASHP, a CO 2 GSHP integrated with well water, and a R-410A GSHP integrated with well water. Simulations were conducted at both equipment and building integration levels, followed by a nationwide analysis across 10 selected cities. Results indicate that integrating GSHP technology with existing water wells (e.g., artesian, bedrock, drilled, and collector wells) is a feasible heating solution because of their high flow rates, good water quality, stable temperatures, and low environmental impact. Although R-410A systems demonstrate higher efficiency, CO 2 systems are more suitable for heating from contamination-free and energy security perspective. The CO 2 GSHPs maintain better performance in colder climates compared with that of ASHPs, providing higher coefficient of performance and environmental benefits because CO 2 refrigerant leakage would not contaminate well water. A national analysis confirms that CO 2 GSHPs outperform furnaces, especially in cold climates, making them a promising solution for residential heating.

15 GEOTHERMAL ENERGY↗

Virtual Refrigerant Charge Sensing Method for Next-Generation Refrigerant in Residential Heat Pumps

The charge level of refrigerant in heat pump systems significantly affects their operational performance. Virtual refrigerant charge (VRC) sensing technology has been well-established for traditional refrigerants (HFCs and HCFCs) for its low cost compared to physical sensors. However, other than traditional refrigerants, HFOs are increasingly used in next-generation heat pumps; whether these conventional VRC sensing methods remain applicable for heat pump systems utilizing next-generation refrigerants requires further investigation. To address these issues, this study develops a low-cost VRC sensing method for next-generation refrigerant heat pumps used in residential buildings. The developed algorithm is evaluated by using simulation models to evaluate the accuracy, considering an R454B heat pump with a nominal heating capacity of 51K Btu/hr (14.95 kW) as an example, and compared with those of the two reference VRC sensing algorithms. Though the developed VRC sensing algorithm and the two reference methods can accurately predict the charge level for the R454B heat pump system (with mean absolute percentage error for various cooling and heating conditions less than 7%), the developed VRC sensing algorithm uses fewer sensors and improves the overall accuracy for heating conditions by 7.1%, and the accuracy for undercharge cooling conditions 14.2%, compared with a mainstream algorithm. This technology will complement physical leakage detectors, and promote the adoption of next-generation heat pump systems, along with reducing wasted energy and maintenance costs.

Liang, Chenjiyu↗

REIMAGINING HEAT EXCHANGERS FOR NEXT GENERATION ENVIRONMENTAL SYSTEMS

Air-to-refrigerant heat exchangers (HXs) are essential components in space conditioning, refrigeration, and power systems, and recent efforts have focused on making these devices more compact, reducing refrigerant charge and lowering manufacturing costs. Historically, HX innovation has been limited by available computational resources, design tools, and manufacturing constraints. The best available technologies utilize tube-fin and micro- or macro-channel tubes with fins, which are not necessarily the optimal designs achievable with current technology. In this paper, we highlight the latest advancements in air-to-refrigerant HXs, specifically emphasizing innovations achieved through shape and topology optimization. A multi-scale design optimization approach is introduced, alongside similar methods in literature, which enable highly sophisticated shape-optimized tube designs with more than 50% reduction in size and 25% reduction in refrigerant charge, essential for A3 refrigerant charge limit compliance. The frameworks integrate traditional heat and mass transfer science with state-of-the-art machine learning, genetic algorithms, and adjoint algorithms to create novel designs. While many of these innovative designs may not be manufacturable using conventional methods, they allow us explore the boundaries of what is possible. These novel air-to-refrigerant HXs are key enablers for ultra-low-refrigerant charge heat pump and refrigeration systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The coordinate transformation method for design of polarizers on HL-2A electron cyclotron resonance heating and current drive systems

Polarizers are widely used to change the polarization of millimeter waves on the electron cyclotron resonance heating and current drive (ECRH and CD) systems. A new method based on the coordinate transformation and the Fourier expansion (the so-called C-method) has been developed for design of polarizers on the HL-2A ECRH and CD systems. This method transforms the grating problem to an eigenvalue problem, making it easy and clear to understand and solve. The comparison between the C-method, the integral method, and the low power test results is presented. It indicates that the C-method can be considered as a rigorous numerical method for the design of polarizers. Finally, two polarizers were designed based on the C-method which can be used together to achieve almost arbitrary polarization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Super Boiler 2 nd Generation Technology for Watertube Boilers

This report describes Phase I of a proposed two phase project to develop and demonstrate an advanced industrial watertube boiler system with the capability of reaching 94% (HHV) fuel-to-steam efficiency and emissions below 2 ppmv NO x , 2 ppmv CO, and 1 ppmv VOC on natural gas fuel. The boiler design would have the capability to produce >1500°F, >1500 psig superheated steam, burn multiple fuels, and will be 50% smaller/lighter than currently available watertube boilers of similar capacity. This project is built upon the successful Super Boiler project at GTI. In that project that employed a unique two-staged intercooled combustion system and an innovative heat recovery system to reduce NO x to below 5 ppmv and demonstrated fuel-to-steam efficiency of 94% (HHV). This project was carried out under the leadership of GTI with project partners Cleaver-Brooks, Inc., Nebraska Boiler, a Division of Cleaver-Brooks, and Media and Process Technology Inc., and project advisors Georgia Institute of Technology, Alstom Power Inc., Pacific Northwest National Laboratory and Oak Ridge National Laboratory. Phase I of efforts focused on developing 2 nd generation boiler concepts and performance modeling; incorporating multi-fuel (natural gas and oil) capabilities; assessing heat recovery, heat transfer and steam superheating approaches; and developing the overall conceptual engineering boiler design. Based on our analysis, the 2 nd generation Industrial Watertube Boiler when developed and commercialized, could potentially save 265 trillion Btu and $1.6 billion in fuel costs across U.S. industry through increased efficiency. Its ultra-clean combustion could eliminate 57,000 tons of NO x , 460,000 tons of CO, and 8.8 million tons of CO 2 annually from the atmosphere. Reduction in boiler size will bring cost-effective package boilers into a size range previously dominated by more expensive field-erected boilers, benefiting manufacturers and end users through lower capital costs.

03 NATURAL GAS↗

A comparative assessment of the economic viability of nuclear-integrated direct air capture systems

Direct air capture (DAC) systems require heat and electricity to operate, which can be supplied by nuclear power plants (NPPs). In this study, the performance and cost of various conceptual nuclear-DAC systems are assessed, and their performance is compared with several non-nuclear options. Three nuclear-DAC systems are considered: (1) a liquid solvent direct air capture (L-DAC) system with heat supplied from natural gas (NG) and electricity supplied by an NPP, (2) an electrified L-DAC system, fully powered by electricity from an NPP, and (3) a solid sorbent direct air capture (S-DAC) system utilizing both heat and electricity generated by an NPP. Two nuclear technologies are considered: a pressurized water reactor and a high-temperature gas-cooled reactor. Under the medium conservatism scenario, the levelized cost of direct air capture (LCOD) for these systems range from $\$$310/tCO 2 to $\$$525/tCO 2 with the L-DAC system having an NG heat supply at the lower end of the range, and the electrified L-DAC system and the S-DAC system at the higher end of the range. Coupling with nuclear energy led to a 21 % reduction in LCOD for the L-DAC system with NG heat supply and a 29 % reduction for the S-DAC system when compared to fully NG-powered options. When powering the DAC system with grid electricity, the LCOD is highly dependent on the assumed electricity price and carbon intensity. The nuclear option is the cheaper choice when the price of low-carbon grid electricity exceeds $\$$95/MWh and $\$$45/MWh for the L-DAC and S-DAC systems, respectively.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A Novel Method Of Gradient Forming and Fluid Manipulation in Reduced Gravity Environments

The use of magnetic fields to control the motion and position of non-conducting liquids has received growing interest in recent times. The possibility of using the forces exerted by a nonuniform magnetic field on a ferrofluid to not only achieve fluid manipulation but also to actively control fluid motion makes it an attractive candidate for applications such as heat transfer in space systems. Terrestrial heat transfer equipment often relies on the normal gravitational force to hold liquid in a desired position or to provide a buoyant force to enhance the heat transfer rate. The residual gravitational force present in a space environment may no longer serve these useful functions and other forces, such as surface tension, can play a significant role in determining heat transfer rates. Although typically overwhelmed by gravitational forces in terrestrial applications, the body force induced in a ferrofluid by a nonuniform magnetic field can help to achieve these objectives in a microgravity environment. This paper will address the fluid manipulation aspect and will comprise of results from model fluid experiments and numerical modeling of the problem. Results from a novel method of forming concentration gradients that are applicable to low gravity applications will be presented. The ground based experiments are specifically tailored to demonstrate the magnetic manipulation capability of a ferrofluid and show that gravitational effects can be countered in carefully designed systems. The development of governing equations for the system will be presented along with a sampling of numerical results.

Ramachandran N.↗

Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States

District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.

district heating↗

Miniature Loop Heat Pipe with Multiple Evaporators for Thermal Control of Small Spacecraft

This paper presents an advanced miniature heat transport system for thermal control of small spacecraft. The thermal system consists of a loop heat pipe (LHP) with multiple evaporators and multiple deployable radiators for heat transfer, and variable emittance coatings on the radiators for performance enhancement. Thermoelectric coolers are used to control the loop operating temperature. The thermal system combines the functions of variable conductance heat pipes, thermal switches, thermal diodes, and the state-of-the-art LHPs into a single integrated thermal system. It retains all the performance characteristics of state-of-the-art LHPs and offers additional advantages to enhance the functionality, performance, versatility, and reliability of the system. Steady state and transient analytical models have been developed, and scaling criteria have also been established. A breadboard unit has been built for functional testing in laboratory and thermal vacuum environments. Experimental results show excellent performance of the thermal system and correlate very well with theoretical predictions.

Ku, Jentung↗

Building America Case Study: Standard- Versus High-Velocity Air Distribution in High-Performance Townhomes, Denver, Colorado

IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore the small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements. Ultimately, the builder decided that adoption of these practices would be too disruptive midstream in the construction cycle. However, the townhomes met the ENERGY STAR Version 3.0 program requirements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase equilibrium and intermediate phases in the Eu-Sb system

Rapid heating rate thermal analysis, X-ray diffraction, fluorescence spectrometry, and differential dissolution method were used to study the high-temperature phase equilibrium in the Eu-Sb system within the composition range between 37 and 96 at% Sb. The techniques were effective in determination of the vapor-solid-liquid equilibrium since intermediate phases except Eu{sub 4}Sb{sub 3} evaporated incongruently after melting. A thermal procedure was developed to determine the liquidus and solidus lines of the T-x diagram. Six stable phases were identified: two phases, EuSb{sub 2} and Eu{sub 4}Sb{sub 3}, melt congruently at 1045{+-}10 deg. C and 1600{+-}15 deg. C, the Eu{sub 2}Sb{sub 3}, Eu{sub 11}Sb{sub 10}, Eu{sub 5}Sb{sub 4}, and Eu{sub 5}Sb{sub 3} phases melt incongruently at 850{+-}8 deg. C, 950{+-}10 deg. C, 1350{+-}15 deg. C, and 1445{+-}15 deg. C, respectively. The exact composition shifting of Sb-rich decomposable phases towards Eu{sub 4}Sb{sub 3}, the most refractory compound, was determined. The topology of the Eu-Sb phase diagram was considered together with that of the Yb-Sb system. - Graphical abstract: The high-temperature range of the T-x phase diagram for the Eu-Sb system. Highlights: > The phase relations in the Eu-Sb system were studied over a large composition and temperature scale. > The liquidus and solidus lines of the T-x diagram were well established using effective techniques. > In the system, six binary phases are stable and they melt incongruently except EuSb{sub 2} and Eu{sub 4}Sb{sub 3}. > Incongruent evaporation was found to be typical of all the phases besides Eu{sub 4}Sb{sub 3}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combined Cooling, Heating, and Power (CCHP) System: Cooperative Research and Development Final Report, CRADA Number CRD-14-570

NREL and Be Power Tech, Inc. (Be Power) will jointly develop a new combined cooling, heating, and power (CCHP) system that uses desiccants in combination with evaporative cooling and fuel cells. The combined system will have better economics and business case than a separate desiccant enhanced air conditioner and fuel cell system. The overall system is expected to become a net revenue generator by delivering power and air conditioning to a building while inputting natural gas and water. This development effort will revolve around adapting NREL's desiccant cooling technology to work with Be Power's proprietary system integration design for CCHP systems. The objective of the CRADA is to develop, then commercialize this CCHP system by jointly developing the system integration design, testing methods, and hardware for this system. The commercial name given to the CCHP system is BeCool.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗