Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HIGH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

In-situ synchrotron x-ray study of phase transitions in melamine under high pressures and high temperatures

We report a synchrotron energy-dispersive x-ray diffraction study of melamine at high pressure and high temperature. Pressure was generated using a Paris-Edinburgh cell to employ larger sample volumes for weakly scattering organic samples. High temperatures were created using a resistive/graphitic cup surrounding the sample. The PT phase diagram was explored by first pressurizing the sample to 3.5 GPa at room temperature and then heating it up to 1197 K with a concomitant pressure increase to just above 5 GPa. Above 4.85 GPa and 967 K, an irreversible phase transition was observed. Upon cooling the sample, another phase transition was observed which is likely associated with polymerization observed in earlier ex-situ HPHT experiments.

36 MATERIALS SCIENCE↗

Need for High Radiation Dose (>=70 Gy) in Early Postoperative Irradiation After Radical Prostatectomy: A Single-Institution Analysis of 334 High-Risk, Node-Negative Patients

Purpose: To determine the clinical benefit of high-dose early adjuvant radiotherapy (EART) in high-risk prostate cancer (hrCaP) patients submitted to radical retropubic prostatectomy plus pelvic lymphadenectomy. Patients and Methods: The clinical outcome of 334 hrCaP (pT3-4 and/or positive resection margins) node-negative patients submitted to radical retropubic prostatectomy plus pelvic lymphadenectomy before 2004 was analyzed according to the EART dose delivered to the prostatic bed, <70.2 Gy (lower dose, median 66.6 Gy, n = 153) or >=70.2 Gy (median 70.2 Gy, n = 181). Results: The two groups were comparable except for a significant difference in terms of median follow-up (10 vs. 7 years, respectively) owing to the gradual increase of EART doses over time. Nevertheless, median time to prostate-specific antigen (PSA) failure was almost identical, 38 and 36 months, respectively. At univariate analysis, both 5-year biochemical relapse-free survival (bRFS) and disease-free survival (DFS) were significantly higher (83% vs. 71% [p = 0.001] and 94% vs. 88% [p = 0.005], respectively) in the HD group. Multivariate analysis confirmed EART dose >=70 Gy to be independently related to both bRFS (hazard ratio 2.5, p = 0.04) and DFS (hazard ratio 3.6, p = 0.004). Similar results were obtained after the exclusion of patients receiving any androgen deprivation. After grouping the hormone-naive patients by postoperative PSA level the statistically significant impact of high-dose EART on both 5-year bRFS and DFS was maintained only for those with undetectable values, possibly owing to micrometastatic disease outside the irradiated area in case of detectable postoperative PSA values. Conclusion: This series provides strong support for the use of EART doses >=70 Gy after radical retropubic prostatectomy in hrCaP patients with undetectable postoperative PSA levels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determinants of Complications and Outcome in High-Risk Squamous Cell Head-and-Neck Cancer Treated With Perioperative High-Dose Rate Brachytherapy (PHDRB)

Purpose: To determine the impact of a set of patient, tumor, and treatment factors on toxicity and outcome in patients with head-and-neck squamous cell cancer treated with surgical resection and perioperative high-dose rate brachytherapy (PHDRB) alone (single-modality [SM] group) (n = 46) or PHDRB combined with postoperative radiation or chemoradiation (combined-modality [CM] group) (n = 57). Methods and Materials: From 2000 to 2008, 103 patients received PHDRB after complete macroscopic resection. SM patients received 32 or 40 Gy of PHDRB in 8 or 10 twice-daily treatments for R0 and R1 resections. CM patients received 16 or 24 Gy of PHDRB in 4 or 6 twice-daily treatments for R0 and R1 resections, followed by external radiation of 45 Gy in 25 fractions with or without concomitant chemotherapy. Results: Grade {>=}4 complications according to the Radiation Therapy Oncology Group were more frequent in the SM group than in the CM group (p = 0.024). Grade {>=}3 and {>=}4 complications increased with the antecedent of prior irradiation (p = 0.032 and p = 0.006, respectively) and with TV{sub 150} values of 13 mL or greater (p = 0.032 and p = 0.032, respectively). After a median follow-up of 34.8 and 60.8 months for SM and CM patients, respectively, patients with high-risk margins had a 9-year local control rate of 68.0% whereas patients with wider margins had a 9-year local control of 93.7% (p = 0.045). Patients with primary and recurrent tumors had 9-year actuarial locoregional control rates of 81.8% and 54.2%, respectively (p = 0.003). Patients with lymph-vascular space invasion (LVSI)-positive and LVSI-negative tumors had 9-year distant control rates of 62.8% and 81.6%, respectively (p = 0.034). Disease-free survival rates decreased in recurrent cases (p = 0.006) as well as in LVSI-positive patients (p = 0.035). Conclusions: The complications observed are largely attributable to the antecedent of prior irradiation but can possibly be minimized by meticulous mapping and exhaustive planning to reduce TV{sub 150} values. Patients with high-risk margins, LVSI-positive status, and recurrent disease have a higher risk of treatment failure, and therefore risk-directed treatment strategies are required.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Dose-Rate Brachytherapy Alone for Localized Prostate Cancer in Patients at Moderate or High Risk of Biochemical Recurrence

Purpose: To evaluate genitourinary (GU) and gastrointestinal (GI) morbidity and biochemical control of disease in patients with localized prostate adenocarcinoma treated with escalating doses per fraction of high-dose rate brachytherapy alone. Methods and Materials: A total of 197 patients were treated with 34 Gy in four fractions, 36 Gy in four fractions, 31.5 Gy in three fractions, or 26 Gy in two fractions. Median follow-up times were 60, 54, 36, and 6 months, respectively. Results: Incidence of early Grade {>=} 3 GU morbidity was 3% to 7%, and Grade 4 was 0% to 4%. During the first 12 weeks, the highest mean International Prostate Symptom Score (IPSS) value was 14, and between 6 months and 5 years it was 8. Grade 3 or 4 early GI morbidity was not observed. The 3-year actuarial rate of Grade 3 GU was 3% to 16%, and was 3% to 7% for strictures requiring surgery (4-year rate). An incidence of 1% Grade 3 GI events was seen at 3 years. Late Grade 4 GU or GI events were not observed. At 3 years, 99% of patients with intermediate-risk and 91% with high-risk disease were free of biochemical relapse (log-rank p = 0.02). Conclusions: There was no significant difference in urinary and rectal morbidity between schedules. Biochemical control of disease in patients with intermediate and high risk of relapse was good.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An information theoretic approach to use high-fidelity codes to calibrate low-fidelity codes

For many simulation models, it can be prohibitively expensive or physically infeasible to obtain a complete set of experimental data to calibrate model parameters. In such cases, one can alternatively employ validated higher-fidelity codes to generate simulated data, which can be used to calibrate the lower-fidelity code. In this paper, we employ an information-theoretic framework to determine the reduction in parameter uncertainty that is obtained by evaluating the high-fidelity code at a specific set of design conditions. These conditions are chosen sequentially, based on the amount of information that they contribute to the low-fidelity model parameters. The goal is to employ Bayesian experimental design techniques to minimize the number of high-fidelity code evaluations required to accurately calibrate the low-fidelity model. We illustrate the performance of this framework using heat and diffusion examples, a 1-D kinetic neutron diffusion equation, and a particle transport model, and include initial results from the integration of the high-fidelity thermal-hydraulics code Hydra-TH with a low-fidelity exponential model for the friction correlation factor.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient tree decomposition of high-rank tensors [Efficient decomposition of high-rank tensors]

Tensors are a natural way to express correlations among many physical variables, but storing tensors in a computer naively requires memory which scales exponentially in the rank of the tensor. This is not optimal, as the required memory is actually set not by the rank but by the mutual information amongst the variables in question. Representations such as the tensor tree perform near-optimally when the tree decomposition is chosen to reflect the correlation structure in question, but making such a choice is non-trivial and good heuristics remain highly context-specific. In this work I present two new algorithms for choosing efficient tree decompositions, independent of the physical context of the tensor. The first is a brute-force algorithm which in most cases produces optimal decompositions but is generally impractical for high-rank tensors, as the number of possible choices grows exponentially in rank. Here, the second is a greedy algorithm, and while it is not optimal it performs extremely well in numerical experiments while having runtime which makes it practical even for tensors of very high rank.

97 MATHEMATICS AND COMPUTING↗

Crystallization behavior in a highly driven marginal glass forming alloy

Al{sub 90}Sm{sub 10}, a marginal glass former, was rapidly solidified using Cu-block single roller melt spinning at wheel speeds of 30 and 40 m/s. The product phases of rapid solidification were identified and analyzed using high energy synchrotron X-ray diffraction (HEXRD), high resolution transmission electron microscopy, and atom probe tomography. The as-quenched structure consists of a saturated amorphous phase and nanocrystalline Al with typical length scale of about 5 nm. The appearance of a pre-peak on HEXRD diffraction patterns and a low activation energy for first crystallization as determined using the Kissinger and Ozawa methods indicate some local ordering in the amorphous phase. The devitrification phase transformation path was determined using in situ high energy synchrotron radiation. Three phases, MS1, H1, and Al{sub 4}Sm, were identified during decomposition of the amorphous phase. MS1, H1 and Al{sub 4}Sm are cubic, hexagonal and orthorhombic metastable phases, respectively.

36 MATERIALS SCIENCE↗

Investigation of temperature dependence of fracture toughness in high-dose HT9 steel using small-specimen reuse technique

The temperature dependence of fracture toughness in HT9 steel irradiated to 3–145 dpa at 380–503 degrees*C was investigated using miniature three-point bend (TPB) fracture specimens. A miniature-specimen reuse technique has been established: the tested halves of subsize Charpy impact specimens with dimensions of 27 mm *3mm* 4 mm were reused for this fracture test campaign by cutting a notch with a diamond-saw in the middle of each half, and by fatigue-precracking to generate a sharp crack tip. It was confirmed that the fracture toughness of HT9 steel in the dose range depends more strongly on the irradiation temperature than the irradiation dose. At an irradiation temperature <430 *degreesC, the fracture toughness of irradiated HT9 increased with the test temperature, reached an upper shelf of 180—200 MPa*m^.5 at 350–450 degrees*C, and then decreased with the test temperature. At an irradiation temperature >430 degrees*C, the fracture toughness was nearly unchanged up to about 450 *degreesC and decreased slowly with test temperatures in a higher temperature range. Such a rather monotonic test temperature dependence after high-temperature irradiation is similar to that observed for an archive material generally showing a higher degree of toughness. A brittle fracture without stable crack growth occurred in only a few specimens with relatively lower irradiation and test temperatures. In this discussion, these TPB fracture toughness data are compared with previously published data from 12.7 mm diameter disc compact tension (DCT) specimens.

Baek, Jong-Hyuk↗

Predictive modeling of crystal accumulation in high-level waste glass melters processing radioactive waste

The effectiveness of HLW vitrification is limited by precipitation/accumulation of spinel crystals [(Fe, Ni, Mn, Zn)(Fe, Cr)2O4] in the glass discharge riser of Joule-heated ceramic melters during idling. These crystals do not affect glass durability; however, if accumulated in thick layer, they can clog the melter and prevent discharge of molten glass into canisters. To address this problem, an empirical model was developed that can predict thicknesses of accumulated layers as a function of glass composition. This model predicts well the accumulation of single crystals and/or small-scale agglomerates, but, excessive agglomeration observed in high-Ni-Fe glass resulted in an under-prediction of accumulated layers, which gradually worsen over time as an increased number of agglomerates formed. Accumulation rate of ~53.8 ± 3.7 µm/h determined for this glass will result in ~26 mm thick layer in 20 days of melter idling.

Crystal accumulation↗

High-temperature Tribological Behavior of Structural Materials after Conditioning in Impure-Helium Environments for High_temperature Gas-Cooled Reactor Applications

Incoloy 800HT and Inconel 617 have been selected as candidate structural alloys for the hightemperature gas-cooled reactor (HTGR) concept. Helium, the primary coolant, contains impurities (e.g., H2O and CH4) that can induce corrosion reactions at high temperatures, which in turn can affect the tribological behavior of components in sliding contact such as valves and control-rod drive systems. This paper presents results from the study of the tribological behavior of both alloys before and after conditioning them in either an impure-helium oxidizing environment or in an air environment. Both alloys were conditioned for 22 days at elevated temperatures in a once-through helium loop with 4 ppmv H2O and tested subsequently at elevated temperatures with a pin-on-disk tribometer in an air environment 650 degrees C and 750 degrees C for 800HT; 850 degrees C and 900 degrees C for 617 - with various applied loads - 1 N, 2 N and 5 N. SEM-EDS analysis revealed that conditioning the samples in an oxidizing environment leads to the formation of a mixed Fe/Cr-oxide on alloy 800HT and a Cr-oxide on alloy 617, both increasing the wear resistance compared to that of as-received samples. Alloy 617 exhibited lower steady-state friction coefficients compared to those of alloy 800HT. There was a significant decrease in the scatter of the steadystate friction coefficient of the conditioned samples compared to that of the unconditioned samples. The steady-state friction coefficient for alloy 800HT and 617 were found to be 0.53 +/- 0.07 and 0.25 +/- 0.04, respectively. The wear resistance of alloy 800HT is approximately one order of magnitude lower than that of alloy 617 in all cases that exhibited measurable wear. After sample conditioning, the wear volumes measured at low loads were undistinguishable from the unworn background, a result attributed to the formation of a compacted glaze layer under high temperatures and high contact stresses.

Alloys 800 and 617↗

Under the microscope: Reduced activation ferritic martensitic steel Eurofer-97 following ion-Irradiation and high-temperature high-pressure water exposure

Here, this study is designed to characterise the microstructural behaviour of Eurofer-97 steel under ion irradiation and subsequent exposure to high-temperature high-pressure (HTHP) water. Eurofer-97, a ferritic-martensitic steel, has been developed to withstand the conditions of fusion reactors in the locations in contact with coolant with an elevated level of neutron flux, such as the breeder-wall blanket. The material has been studied after self-ion irradiation (using Fe ions) simulating the microstructural effects of neutron irradiation limited to the subsurface layer. The corrosion properties of the Eurofer-97 steel were studied by exposure to HTHP water up to 331 °C. Advanced microstructural characterisation using scanning, transmission electron and focused ion beam microscopy was performed on the as-received microstructure and after ion irradiation. This was then characterised after exposure for 240 h in high-temperature water. Eurofer-97 had a dense, columnar Cr-rich inner oxide, followed by a Fe-rich outer oxide layer. In the irradiated condition the grain structure and oxide itself was less ordered. No appreciable difference in oxide thickness was identified between the irradiated and unirradiated specimens after this short exposure time.

36 MATERIALS SCIENCE↗

High-rate, high-capacity electrochemical energy storage in hydrogen-bonded fused aromatics

Designing materials for electrochemical energy storage with short charging times and high charge capacities is a longstanding challenge. The fundamental difficulty lies in incorporating a high density of redox couples into a stable material that can efficiently conduct both ions and electrons. We report all-organic, fused aromatic materials that store up to 310 mAh g –1 and charge in as little as 33 s. This performance stems from abundant quinone/imine functionalities that decorate an extended aromatic backbone, act as redox-active sites, engage in hydrogen bonding, and enable a delocalized high-rate energy storage with stability upon cycling. Here, the extended conjugation and hydrogen-bonding-assisted bulk charge storage contrast with the surface-confined or hydration-dependent behavior of traditional inorganic electrodes.

36 MATERIALS SCIENCE↗