Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

DESIGN OF A THERMOSIPHON FOR COOLING LOW-BACKGROUND HPGE ARRAYS

ABSTRACT A two-phase nitrogen thermosiphon was developed for the new generation of low-background high-purity germanium (HPGe) arrays. The cooling system for these arrays has to be able to handle the heat load (>20 W) presented by a large detector mass while meeting stringent requirements necessary for low-background systems. The HPGe detector modules should operate as close to liquid nitrogen temperature (<80K) as possible to provide adequate operating conditions for a full range of HPGe impurity concentrations. In addition, exceptional temperature stability (<1 K) is needed to reduce electronic gain shifts due to changes in the front-end electronics operating temperature. In order to meet the background requirements of state-of-the-art systems these arrays are enclosed in passive lead and copper shielding up to 1 m thick. In this paper we present a cooling system for low-background experiments that complies with these stringent geometrical restrictions. Active cooling was integrated via a horizontal thermosiphon that can be fabricated using ultra-pure electroformed copper. It was charged with nitrogen to 434 kPa (63 PSIA) at 292 K, which provided a fill ratio of 10%. The results showed that the thermosiphon can effectively remove in excess of 25 W of heat load.

low-background, thermal conductivity, radiation de↗

Precision equation-of-state measurements on National Ignition Facility ablator materials from 1 to 12 Mbar using laser-driven shock waves

A large uncertainty in the design of ignition capsules for use in the National Ignition Campaign (NIC) is the ablator equation of state. In this article, we report equation-of-state measurements for two candidate NIC ablator materials, glow-discharge polymer (GDP), and germanium-doped GDP. These materials were driven to pressures of 1 to 12 Mbar using laser-driven shock waves. Hugoniot measurements were obtained using the impedance matching technique with an α-quartz standard. This article presents the first kinematic measurements in the high-pressure fluid regime for these materials, which show to be in close agreement with Livermore equation-of-state model predictions.

Barrios, M. A.↗

Invited Review Article: Physics and Monte Carlo techniques as relevant to cryogenic, phonon, and ionization readout of Cryogenic Dark Matter Search radiation detectors

This review discusses detector physics and Monte Carlo techniques for cryogenic, radiation detectors that utilize combined phonon and ionization readout. A general review of cryogenic phonon and charge transport is provided along with specific details of the Cryogenic Dark Matter Search detector instrumentation. In particular, this review covers quasidiffusive phonon transport, which includes phonon focusing, anharmonic decay, and isotope scattering. The interaction of phonons in the detector surface is discussed along with the downconversion of phonons in superconducting films. The charge transport physics include a mass tensor which results from the crystal band structure and is modeled with a Herring-Vogt transformation. Charge scattering processes involve the creation of Neganov-Luke phonons. Transition-edge-sensor (TES) simulations include a full electric circuit description and all thermal processes including Joule heating, cooling to the substrate, and thermal diffusion within the TES, the latter of which is necessary to model normal-superconducting phase separation. Relevant numerical constants are provided for these physical processes in germanium, silicon, aluminum, and tungsten. Random number sampling methods including inverse cumulative distribution function (CDF) and rejection techniques are reviewed. To improve the efficiency of charge transport modeling, an additional second order inverse CDF method is developed here along with an efficient barycentric coordinate sampling method of electric fields. Results are provided in a manner that is convenient for use in Monte Carlo and references are provided for validation of these models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Lifetime measurement of the 6.79 MeV state in {sup 15}O with the AGATA demonstrator

The {sup 14}N(p,{gamma}){sup 15}O reaction is the slowest process of the CN cycle, and thus it is of high astrophysical interest since it regulates the total rate of energy and neutrinos production through the cycle. The {sup 14}N+p ground state capture is strongly influenced by a sub-threshold resonance corresponding to the 6.79 MeV state in {sup 15}O. The width of this resonance is a major source of uncertainty in the extrapolation of the reaction cross section in the Gamow energy window. Preliminary results of a new Doppler Shift Attenuation measurement of the lifetime of the 6.79 MeV state in {sup 15}O are discussed. The level of interest was populated via the {sup 2}H({sup 14}N,n){sup 15}O reaction in inverse kinematics at 32 MeV beam energy. The gamma-rays emitted in the decay of the 6.79 MeV level to the ground state were detected with the AGATA Demonstrator array of high-purity germanium detectors. The sensitivity of the shape of the peak in the gamma-ray energy spectrum to the level lifetime is investigated comparing the experimental peaks with detailed Monte Carlo simulations of the reaction mechanisms and the gamma-ray emission and detection. Nuclear levels in {sup 15}N (also populated in the {sup 14}N+{sup 2}H reaction) for which the lifetimes are known in the literature provided a test of the analysis technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative comparison between PGNAA measurements and MCNP calculations in view of the characterization of radioactive wastes in Germany and France

The Forschungszentrum Juelich GmbH (FZJ), together with the Aachen University Rheinisch-Westfaelische Technische Hochschule (RWTH) and the French Alternative Energies and Atomic Energy Commission (CEA Cadarache) are involved in a cooperation aiming at characterizing toxic and reactive elements in radioactive waste packages by means of Prompt Gamma Neutron Activation Analysis (PGNAA). The French and German waste management agencies have indeed defined acceptability limits concerning these elements in view of their projected geological repositories. A first measurement campaign was performed in the new Prompt Gamma Neutron Activation Analysis (PGNAA) facility called MEDINA, at FZJ, to assess the capture gamma-ray signatures of some elements of interest in large samples up to waste drums with a volume of 200 liter. MEDINA is the acronym for Multi Element Detection based on Instrumental Neutron Activation. This paper presents MCNP calculations of the MEDINA facility and quantitative comparison between measurement and simulation. Passive gamma-ray spectra acquired with a high purity germanium detector and calibration sources are used to qualify the numerical model of the crystal. Active PGNAA spectra of a sodium chloride sample measured with MEDINA then allow for qualifying the global numerical model of the measurement cell. Chlorine indeed constitutes a usual reference with reliable capture gamma-ray production data. The goal is to characterize the entire simulation protocol (geometrical model, nuclear data, and postprocessing tools) which will be used for current measurement interpretation, extrapolation of the performances to other types of waste packages or other applications, as well as for the study of future PGNAA facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Precision lifetime measurements of exotic nuclei based on Doppler-shift techniques

A recent progress in precision lifetime measurements of exotic nuclei at the National Superconducting Cyclotron Laboratory (NSCL), Michigan State University is presented. The Recoil Distance Doppler-shift (RDDS) technique has been applied to nuclear reactions involving intermediate-energy rare isotope (RI) beams, to determine absolute transition strengths between nuclear states model independently from level lifetimes of interest. As such an example, recent lifetime measurements of the first 2{sup +} states in the neutron-rich {sup 62,64,66}Fe isotopes at and around N=40 are introduced. The experiment was performed at the Coupled Cyclotron Facility at NSCL using a unique combination of several experimental instruments; the Segmented Germanium Array (SeGA), the plunger device, and the S800 spectrograph. The reduced E2 transition probabilities B(E2) are determined directly from the measured lifetimes. The observed trend of B(E2) clearly demonstrates that an enhanced collectivity persists in {sup 66}Fe despite the harmonic-oscillator magic number N=40. The present results are also discussed in comparison with the large-scale shell model calculations, pointing to a possible extension of the deformation region beyond N=40.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiopurity control in the NEXT-100 double beta decay experiment

An extensive material screening and selection process is underway in the construction of the 'Neutrino Experiment with a Xenon TPC' (NEXT), intended to investigate neutrinoless double beta decay using a high-pressure xenon gas TPC filled with 100 kg of Xe enriched in {sup 136}Xe. Determination of the radiopurity levels of the materials is based on gamma-ray spectroscopy using ultra-low background germanium detectors at the Laboratorio Subterráneo de Canfranc (Spain) and also on Glow Discharge Mass Spectrometry. Materials to be used in the shielding, pressure vessel, electroluminescence and high voltage components and energy and tracking readout planes have been already taken into consideration. The measurements carried out are presented, describing the techniques and equipment used, and the results obtained are shown, discussing their implications for the NEXT experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BiPo: A dedicated radiopurity detector for the SuperNEMO experiment

New generation experiments in Astroparticle Physics need to operate in really restrictive background conditions, which implies the use of high radiopure materials for the experimental setup construction. For this reason the screening of the materials with enough sensitivity has become a challenge that sometimes cannot be afforded with standard techniques like Germanium detector spectroscopy. BiPo is a dedicated detector, that operates in the Canfranc Underground Laboratory, designed to measure the radiopurity, mainly of the ββ sources of the SuperNEMO experiment, by the detection of BiPo events. It is composed of two modules with 40 optical lines each one, registering the energy and the time of the emitted particles. The well known features of the BiPo events (delayed coincidence between an electron and an alpha particle) facilitate the discrimination of other background events that could entangle the expected signal. In addition, the geometry of the detector, with an active area of around 3.6 m{sup 2}, has been optimized to reach the necessary sensitivity levels for the SuperNEMO source foils in the shortest time possible. Preliminary results of background measurements and calibrations taken since summer 2012 shows that the required sensitivity for the measurements of the source foils could be reached in few months. Routine measurements of samples are already started being an important point for the SuperNEMO source foils construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low background high efficiency radiocesium detection system based on positron emission tomography technology

After the 2011 nuclear power plant accident at Fukushima, radiocesium contamination in food became a serious concern in Japan. However, low background and high efficiency radiocesium detectors are expensive and huge, including semiconductor germanium detectors. To solve this problem, we developed a radiocesium detector by employing positron emission tomography (PET) technology. Because {sup 134}Cs emits two gamma photons (795 and 605 keV) within 5 ps, they can selectively be measured with coincidence. Such major environmental gamma photons as {sup 40}K (1.46 MeV) are single photon emitters and a coincidence measurement reduces the detection limit of radiocesium detectors. We arranged eight sets of Bi{sub 4}Ge{sub 3}O{sub 12} (BGO) scintillation detectors in double rings (four for each ring) and measured the coincidence between these detectors using PET data acquisition system. A 50 × 50 × 30 mm BGO was optically coupled to a 2 in. square photomultiplier tube (PMT). By measuring the coincidence, we eliminated most single gamma photons from the energy distribution and only detected those from {sup 134}Cs at an average efficiency of 12%. The minimum detectable concentration of the system for the 100 s acquisition time is less than half of the food monitor requirements in Japan (25 Bq/kg). These results show that the developed radiocesium detector based on PET technology is promising to detect low level radiocesium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray spectroscopy of warm and hot electron components in the CAPRICE source plasma at EIS testbench at GSI

An experimental campaign aiming to detect X radiation emitted by the plasma of the CAPRICE source – operating at GSI, Darmstadt – has been carried out. Two different detectors (a SDD – Silicon Drift Detector and a HpGe – hyper-pure Germanium detector) have been used to characterize the warm (2–30 keV) and hot (30–500 keV) electrons in the plasma, collecting the emission intensity and the energy spectra for different pumping wave frequencies and then correlating them with the CSD of the extracted beam measured by means of a bending magnet. A plasma emissivity model has been used to extract the plasma density along the cone of sight of the SDD and HpGe detectors, which have been placed beyond specific collimators developed on purpose. Results show that the tuning of the pumping frequency considerably modifies the plasma density especially in the warm electron population domain, which is the component responsible for ionization processes: a strong variation of the plasma density near axis region has been detected. Potential correlations with the charge state distribution in the plasma are explored.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An assessment of natural radionuclides in water of Langat River estuary, Selangor

An estuary is an area that has a free connection with the open sea and it is a dynamic semi-enclosed coastal bodies. Ex-mining, aquaculture and industrial areas in Selangor are the sources of pollutants discharged into the estuary water. Radionuclides are considered as pollutants to the estuary water. Gamma radiations emitted by natural radionuclides through their decaying process may give impact to human. The radiological effect of natural radionuclides which are {sup 226}Ra, {sup 228}Ra, {sup 40}K, {sup 238}U and {sup 232}Th, were explored by determining the respective activity concentrations in filtered water along the Langat estuary, Selangor. Meanwhile, in- situ water quality parameters such as temperature, dissolve oxygen (DO), salinity, total suspended solid (TSS), pH and turbidity were measured by using YSI portable multi probes meter. The activity concentration of {sup 226}Ra, {sup 228}Ra and {sup 40}K were determined by using gamma-ray spectrometry with high-purity germanium (HPGe) detector. The activity concentrations of {sup 226}Ra, {sup 228}Ra and {sup 40}K in samples are in the range of 0.17 - 0.67 Bq/L, 0.16 - 0.97 Bq/L and 1.22 - 5.57 Bq/L respectively. On the other hand, the concentrations of uranium-238 and thorium-232 were determined by using Energy Dispersive X-ray Fluorescence Spectrometry (EDXRF). The thorium concentrations are between 0.17 ppm to 0.28 ppm and uranium concentrations were 0.25 ppm to 0.31 ppm. The results show activity concentrations of radionuclides are slightly high near the river estuary. The Radium Equivalent, Absorbed Dose Rate, External Hazard Index, and Annual Effective Dose of {sup 226}Ra, {sup 228}Ra and {sup 40}K are also studied.

54 ENVIRONMENTAL SCIENCES↗

Comparison of two HPGe counting system used in activation studies for nuclear astrophysics

The activation method is a widely used technique to measure charged-particle induced cross sections for astrophys-ical applications. This two step technique is used for example to measure alpha-induced cross sections in γ-process related studies. The first step – in which a target is irradiated with a proton/alpha beam – is followed by the determination of the produced activity. Especially in p-process related studies in the heavier mass range, the produced radioactive nuclei decays mainly with electron-capture, resulting intense x-rays. The activity of the reaction products hence can be determine via the counting of these x-rays, and not only by counting the usually much weaker γ-rays. In this paper we compare the minimum detectable activity (MDA) of two High Purity Germanium (HPGe) detectors used for x- and γ-ray counting in activation experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ion-induced gamma-ray detection of fast ions escaping from fusion plasmas

A 12 × 12 pixel detector has been developed and used in a laboratory experiment for lost fast-ion diagnostics. With gamma rays in the MeV range originating from nuclear reactions {sup 9}Be(α, nγ){sup 12}C, {sup 9}Be(d, nγ){sup 12}C, and {sup 12}C(d, pγ){sup 13}C, a high purity germanium (HPGe) detector measured a fine-energy-resolved spectrum of gamma rays. The HPGe detector enables the survey of background-gamma rays and Doppler-shifted photo peak shapes. In the experiments, the pixel detector produces a gamma-ray image reconstructed from the energy spectrum obtained from total photon counts of irradiation passing through the detector's lead collimator. From gamma-ray image, diagnostics are able to produce an analysis of the fast ion loss onto the first wall in principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technique for magnetic susceptibility determination in the highly doped semiconductors by electron spin resonance

A method for determining the magnetic susceptibility in the highly doped semiconductors is considered. It is suitable for the semiconductors near the metal - insulator transition when the conductivity changes very quickly with the temperature and the resonance line form distorts. A procedure that is based on double integration of the positive part of the derivative of the absorption line having a Dyson shape and takes into account the depth of the skin layer is described. Analysis is made for the example of arsenic-doped germanium samples at a rather high concentration corresponding to the insulator-metal phase transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ investigation of explosive crystallization in a-Ge: Experimental determination of the interface response function using dynamic transmission electron microscopy

The crystallization of amorphous semiconductors is a strongly exothermic process. Once initiated the release of latent heat can be sufficient to drive a self-sustaining crystallization front through the material in a manner that has been described as explosive. Here, we perform a quantitative in situ study of explosive crystallization in amorphous germanium using dynamic transmission electron microscopy. Direct observations of the speed of the explosive crystallization front as it evolves along a laser-imprinted temperature gradient are used to experimentally determine the complete interface response function (i.e., the temperature-dependent front propagation speed) for this process, which reaches a peak of 16 m/s. Fitting to the Frenkel-Wilson kinetic law demonstrates that the diffusivity of the material locally/immediately in advance of the explosive crystallization front is inconsistent with those of a liquid phase. This result suggests a modification to the liquid-mediated mechanism commonly used to describe this process that replaces the phase change at the leading amorphous-liquid interface with a change in bonding character (from covalent to metallic) occurring in the hot amorphous material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of general X-ray scattering model

X-ray scattering is a complex process made difficult to describe due to the effects of a complex energy spectrum interacting with a wide range of material types in complex geometry. The scattering is further complicated by the volume of material illuminated and the experimental configuration of the data acquisition. The importance of accounting for the key physics in scattering modeling is critical to the viability of the model. For example, scattering in the detector and the speed of the detector, as measured by the absorbed dose needed to produce a signal, are important in capturing undercut effects. Another example is the noise properties of the detectors are dependent on photon energy. We report on a semi-empirical treatment of x-ray scattering that includes a full energy treatment for a wide range of material types. We also include complex geometry effects that the part shape introduces. The treatment is based on experimental measurements using an energy dispersive germanium detector over energies from treatment is showing good results with experimental measurements of the scattering component agreeing with the model results to the 10% level over the range of x-ray energies and materials typical in industrial applications. Computation times for this model are in the 20 keV to 320 keV. Detector stripping routines for detector artifacts were developed. The computation time is in the range of a few minutes on a typical PC.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for 0ν2β of {sup 100}Mo by NEMO-3 and status of SuperNEMO

The NEMO-3 experiment was devoted to the research of the neutrinoless double beta decay and the precise measurement of the two-neutrino double beta decay of seven isotopes. The detector took data in the Laboratoire Souterrain de Modane (LSM) from 2003 to 2011. The unique combination of a 3D-tracker and a calorimeter allowed to fully reconstruct the double beta decay events topology and strongly reduces the backgrounds. This feature also permitted to characterize the remaining backgrounds in independent analysis channels. With an exposure of 34.7 kg·y of {sup 100}Mo no evidence for the 0ν2β signal has been found, yielding a limit for the light Majorana neutrino mass mechanism of T{sub 1/2}(0ν2β) > 1.1 10{sup 24} years (90 % C.L.) once both statistical and systematic uncertainties are taken into account. Depending on the Nuclear Matrix Elements this corresponds to an upper limit on the Majorana effective neutrino mass of |m{sub ββ}| < 0.3 − 0.9 eV (90 % C.L.). Constraints on other lepton number violating mechanisms of 0ν2β decays are also given. Searching for high-energy double electron events in all suitable sources of the detector, no event in the energy region [3.2-10] MeV is observed for an exposure of 47 kg·y. The next generation experiment, SuperNEMO, will use the same experimental technique to extend the sensitivity on the neutrinoless double beta decay search. Several aspects have been improved compared to NEMO-3: choice of the isotope, energy resolution, energy losses… but the main challenge is the background reduction. All the detector materials have been selected for their low natural radioactivity contaminations through High Purity Germanium (HPGe) gamma spectroscopy. The double beta sources after enrichment are being prepared with extreme care and the ultimate contaminations will be characterized by the most sensitive BiPo detector. External radon tightness and internal radon emanation have been studied to ensure a very low level in the tracker with very sensitive complementary detectors: diffusion apparatus, concentration line and emanation tanks. The construction of the first detector, called the demonstrator, has started in 2012. Studying 7 kg of {sup 82}Se, the demonstrator will reach the NEMO-3 sensitivity in only 5 months and improve it by at least a factor 6 in 2.5 years. Underground installation will start fall 2014 and physics data taking should start by summer 2015.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radon and material radiopurity assessment for the NEXT double beta decay experiment

The ”Neutrino Experiment with a Xenon TPC” (NEXT), intended to investigate the neutrinoless double beta decay using a high-pressure xenon gas TPC filled with Xe enriched in {sup 136}Xe at the Canfranc Underground Laboratory in Spain, requires ultra-low background conditions demanding an exhaustive control of material radiopurity and environmental radon levels. An extensive material screening process is underway for several years based mainly on gamma-ray spectroscopy using ultra-low background germanium detectors in Canfranc but also on mass spectrometry techniques like GDMS and ICPMS. Components from shielding, pressure vessel, electroluminescence and high voltage elements and energy and tracking readout planes have been analyzed, helping in the final design of the experiment and in the construction of the background model. The latest measurements carried out will be presented and the implication on NEXT of their results will be discussed. The commissioning of the NEW detector, as a first step towards NEXT, has started in Canfranc; in-situ measurements of airborne radon levels were taken there to optimize the system for radon mitigation and will be shown too.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗