Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Nonthermal production of WIMPs, cosmic e{sup {+-}} excesses, and {gamma} rays from the Galactic Center

In this paper we propose a dark matter model and study aspects of its phenomenology. Our model is based on a new dark matter sector with a U(1)' gauge symmetry plus a discrete symmetry added to the standard model of particle physics. The new fields of the dark matter sector have no hadronic charges and couple only to leptons. Our model cannot only give rise to the observed neutrino mass hierarchy, but can also generate the baryon number asymmetry via nonthermal leptogenesis. The breaking of the new U(1)' symmetry produces cosmic strings. The dark matter particles are produced nonthermally from cosmic string loop decay which allows one to obtain sufficiently large annihilation cross sections to explain the observed cosmic ray positron and electron fluxes recently measured by the PAMELA, ATIC, PPB-BETS, Fermi-LAT, and HESS experiments while maintaining the required overall dark matter energy density. The high velocity of the dark matter particles from cosmic string loop decay leads to a low phase space density and thus to a dark matter profile with a constant density core in contrast to what happens in a scenario with thermally produced cold dark matter where the density keeps rising towards the center. As a result, the flux of {gamma} rays radiated from the final leptonic states of dark matter annihilation from the Galactic center is suppressed and satisfies the constraints from the HESS {gamma}-ray observations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Testing and Performance Validation of a Sensitive Gamma Ray Camera Designed for Radiation Detection and Decommissioning Measurements in Nuclear Facilities-13044

This paper describes the measurements, testing and performance validation of a sensitive gamma ray camera designed for radiation detection and quantification in the environment and decommissioning and hold-up measurements in nuclear facilities. The instrument, which is known as RadSearch, combines a sensitive and highly collimated LaBr{sub 3} scintillation detector with an optical (video) camera with controllable zoom and focus and a laser range finder in one detector head. The LaBr{sub 3} detector has a typical energy resolution of between 2.5% and 3% at the 662 keV energy of Cs-137 compared to that of NaI detectors with a resolution of typically 7% to 8% at the same energy. At this energy the tungsten shielding of the detector provides a shielding ratio of greater than 900:1 in the forward direction and 100:1 on the sides and from the rear. The detector head is mounted on a pan/tile mechanism with a range of motion of ±180 degrees (pan) and ±90 degrees (tilt) equivalent to 4 π steradians. The detector head with pan/tilt is normally mounted on a tripod or wheeled cart. It can also be mounted on vehicles or a mobile robot for access to high dose-rate areas and areas with high levels of contamination. Ethernet connects RadSearch to a ruggedized notebook computer from which it is operated and controlled. Power can be supplied either as 24-volts DC from a battery or as 50 volts DC supplied by a small mains (110 or 230 VAC) power supply unit that is co-located with the controlling notebook computer. In this latter case both power and Ethernet are supplied through a single cable that can be up to 80 metres in length. If a local battery supplies power, the unit can be controlled through wireless Ethernet. Both manual operation and automatic scanning of surfaces and objects is available through the software interface on the notebook computer. For each scan element making up a part of an overall scanned area, the unit measures a gamma ray spectrum. Multiple radionuclides may be selected by the operator and will be identified if present. In scanning operation the unit scans a designated region and superimposes over a video image the distribution of measured radioactivity. For the total scanned area or object RadSearch determines the total activity of operator selected radionuclides present and the gamma dose-rate measured at the detector head. Results of hold-up measurements made in a nuclear facility are presented, as are test measurements of point sources distributed arbitrarily on surfaces. These latter results are compared with the results of benchmarked MCNP Monte Carlo calculations. The use of the device for hold-up and decommissioning measurements is validated. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effect of atomic electrons on the 7.6-eV nuclear transition in {sup 229}Th{sup 3+}

We have considered an effect of atomic electrons on the nuclear {sup 229m}Th-{sup 229g}Th transition in {sup 229}Th{sup 3+} due to the electronic bridge process. Based on a recent experimental result we assumed the energy difference between the isomeric and the ground nuclear states to be equal to 7.6 eV. We have calculated the ratios of the electronic bridge process probability ({Gamma}{sub EB}) to the probability of the nuclear radiative transition ({Gamma}{sub N}) for the electronic 5f{sub 5/2{yields}}6d{sub 3/2},6d{sub 5/2},7s and the 7s{yields}7p{sub 1/2},7p{sub 3/2} transitions and found {Gamma}{sub EB}/{Gamma}{sub N{approx}}0.01-0.1 for the former and {Gamma}{sub EB}/{Gamma}{sub N{approx}}20 for the latter.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Semiphenomenological approximation of the sums of experimental radiative strength functions for dipole gamma transitions of energy E{sub {gamma}}below the neutron binding energy B{sub n} for mass numbers in the range 40 {<=} A {<=} 200

The sums of radiative strength functions for primary dipole gamma transitions, k(E1) + k(M1), are approximated to a high precision by a superposition of two functional dependences in the energy range 0.5 < E{sub 1} < B{sub n} - 0.5 MeV for the {sup 40}K, {sup 60}Co, {sup 71,74}Ge, {sup 80}Br, {sup 114}Cd, {sup 118}Sn, {sup 124,125}Te, {sup 128}I, {sup 137,138,139}Ba, {sup 140}La, {sup 150}Sm, {sup 156,158}Gd, {sup 160}Tb, {sup 163,164,165}Dy, {sup 166}Ho, {sup 168}Er, {sup 170}Tm, {sup 174}Yb, {sup 176,177}Lu, {sup 181}Hf, {sup 182}Ta, {sup 183,184,185,187}W, {sup 188,190,191,193}Os, {sup 192}Ir, {sup 196}Pt, {sup 198}Au, and {sup 200}Hg nuclei. It is shown that, in any nuclei, radiative strength functions are a dynamical quantity and that the values of k(E1) + k(M1) for specific energies of gamma transitions and specific nuclei are determined by the structure of decaying and excited levels, at least up to the neutron binding energy B{sub n}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for the Rare Radiative Decay: $W\rightarrow\pi\gamma$ in $p\bar{p}$ Collisions at $\sqrt{s} = 1.96$ TeV

We present a search for the rare radiative decay W{sup {+-}} {yields} {pi}{sup {+-}}{gamma} using data corresponding to an integrated luminosity of 4.3 fb{sup -1} of proton-antiproton collisions at a center of mass energy of 1.96 TeV collected by the CDF experiment at Fermilab. As no statistically significant signal is observed, we set a 95% confidence level upper limit on the relative branching fraction {Gamma}(W{sup {+-}} {yields} {pi}{sup {+-}}{gamma})/{Gamma}(W{sup {+-}} {yields} e{sup {+-}}{nu}) at 6.4 x 10{sup -5}, a factor of 10 improvement over the previous limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neurogenic Effects of Low-Dose Whole-Body HZE (Fe) Ion and Gamma Irradiation

Understanding the dose-toxicity profile of radiation is critical when evaluating potential health risks associated with natural and man-made sources in our environment. This study was done to evaluate the effects of low-dose whole-body high-energy charged (HZE) iron (Fe) ions and low-energy gamma exposure on proliferation and differentiation of adult-born neurons within the dentate gyrus of the hippocampus, cells deemed to play a critical role in memory regulation. To determine the dose-response characteristics of the brain to whole-body Fe-ion vs. gamma-radiation exposure, C57BL/6J mice were irradiated with 1 GeV/n Fe ions or a static 137 Cs source (0.662 MeV) at doses ranging from 0 to 300 cGy. The neurogenesis was analyzed at 48 h and one month postirradiation. These experiments revealed that whole-body exposure to either Fe ions or gamma radiation leads to: 1. An acute decrease in cell division within the dentate gyrus of the hippocampus, detected at doses as low as 30 and 100 cGy for Fe ions and gamma radiation, respectively; and 2. A reduction in newly differentiated neurons (DCX immunoreactivity) at one month postirradiation, with significant decreases detected at doses as low as 100 cGy for both Fe ions and gamma rays. The data presented here contribute to our understanding of brain responses to whole-body Fe ions and gamma rays and may help inform health-risk evaluations related to systemic exposure during a medical or radiologic/nuclear event or as a result of prolonged space travel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Closed-Form E1 Radiative Strength Functions for Gamma-Decay and Photoabsorption

Photoabsorption cross sections and {gamma}-decay strength functions are calculated and compared with experimental data to test simple phenomenological models of E1 gamma-strength description in the middle-weight and heavy atomic nuclei. Radiative strength functions with energy asymmetric shape are recommended for overall estimation of averaged gamma-strengths. Systematics for giant dipole resonance (GDR) parameters are given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

THE RADIATIVE X-RAY AND GAMMA-RAY EFFICIENCIES OF ROTATION-POWERED PULSARS

We present a statistical analysis of the X-ray luminosity of rotation-powered pulsars and their surrounding nebulae using the sample of Kargaltsev and Pavlov, and we complement this with an analysis of the {gamma}-ray emission of Fermi-detected pulsars. We report a strong trend in the efficiency with which spin-down power is converted to X-ray and {gamma}-ray emission with characteristic age: young pulsars and their surrounding nebulae are efficient X-ray emitters, whereas in contrast old pulsars are efficient {gamma}-ray emitters. We divided the X-ray sample in a young ({tau}{sub c} < 1.7 x 10{sup 4} yr) and old sample and used linear regression to search for correlations between the logarithm of the X-ray and {gamma}-ray luminosities and the logarithms of the periods and period derivatives. The X-ray emission from young pulsars and their nebulae are both consistent with L{sub X}{proportional_to} P-dot{sup 3}/P{sup 6}. For old pulsars and their nebulae the X-ray luminosity is consistent with a more or less constant efficiency {eta}{identical_to}L{sub X}/ E-dot{sub rot}{approx}8x10{sup -5}. For the {gamma}-ray luminosity we confirm that L{sub {gamma}} {proportional_to} {radical}E-dot{sub rot}. We discuss these findings in the context of pair production inside pulsar magnetospheres and the striped wind model. We suggest that the striped wind model may explain the similarity between the X-ray properties of the pulsar wind nebulae and the pulsars themselves, which according to the striped wind model may both find their origin outside the light cylinder, in the pulsar wind zone.

79 ASTRONOMY AND ASTROPHYSICS↗

Absolute measurements of fast neutrons using yttrium

Yttrium is presented as an absolute neutron detector for pulsed neutron sources. It has high sensitivity for detecting fast neutrons. Yttrium has the property of generating a monoenergetic secondary radiation in the form of a 909 keV gamma-ray caused by inelastic neutron interaction. It was calibrated numerically using MCNPX and does not need periodic recalibration. The total yttrium efficiency for detecting 2.45 MeV neutrons was determined to be f{sub n}{approx}4.1x10{sup -4} with an uncertainty of about 0.27%. The yttrium detector was employed in the NX2 plasma focus experiments and showed the neutron yield of the order of 10{sup 8} neutrons per discharge.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strong and radiative decays of the scalars f{sub 0}(980) and a{sub 0}(980) in a hadronic molecule approach

We analyze the electromagnetic and strong decay properties of the light scalars a{sub 0}(980) and f{sub 0}(980) within a hadronic molecule interpretation. Both scalars are discussed within a covariant and gauge invariant model which also allows for finite size effects due to their spatially extended structure in the KK-bound state picture. Allowing for f{sub 0}-a{sub 0} mixing we also study its influence on the radiative decays f{sub 0}/a{sub 0}{yields}{gamma}{gamma}, f{sub 0}/a{sub 0}{yields}{gamma}{omega}, and f{sub 0}/a{sub 0}{yields}{gamma}{rho} as well as the {phi} production of the f{sub 0} and a{sub 0}. Furthermore, we apply our formalism to describe the strong f{sub 0}{yields}{pi}{pi} and a{sub 0}{yields}{pi}{eta} decay properties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

It's All Relative: A Validation of Radiation Quality Comparison Metrics

Historically, the relative biological effectiveness (RBE) has been calculated to quantify the difference between heavy ion and gamma ray radiation. The RBE is then applied to gamma ray data to predict the effects of heavy ions in humans. The RBE is an iso-effect dose-to-dose ratio which, due to its counterintuitive nature, has been commonly miscalculated as an iso-dose effect-to-effect ratio. A paper recently published by Shuryak et al described this second measure intentionally for the first time in 2017, referring to it as the radiation effects ratio (RER). In this study, we utilized simulations to test the ability of both the RBE and the RER to predict known heavy ion effects. RBEs and RERs were calculated using mouse data from Chang et al, and the ability of the RBE and RER to predict the heavy ion data from which they were calculated was verified. Statistical transformations often utilized during data analysis were applied to the gamma and heavy ion data to determine whether RBE and RER are each uniquely defined measures. Scale changes are expected when translating effects from mice to humans and between human populations; gamma and heavy ion data were transformed to represent potential scale changes. The ability of the RBE and RER to predict the transformed heavy ion data from the transformed gamma data was then tested. The RBE but not the RER was uniquely defined after all statistical transformations. The RBE correctly predicted the scale-transformed heavy ion data, while the RER did not. This presentation describes potential implications for both metrics in light of these findings.

Chappell, L. J.↗

Gamma ray astronomy

A review is given of recent papers in the field of gamma-ray astronomy. It is mentioned that the strongest feature of the gamma ray sky is the general radiation from the galactic plane which is superimposed on what appears to be a general diffuse radiation, whose properties are not yet defined. The observation of high-energy galactic gamma radiation by the SAS-2 satellite is considered as is the observation of point and localized sources (the Crab Nebula, Vela, etc.). The observation of diffusive gamma radiation is discussed.

Fichtel, C. E.↗

Leukemia, lymphoma and multiple myeloma mortality (1950–1999) and incidence (1969–1999) in the Eldorado uranium workers cohort

Uranium workers are chronically exposed to low levels of radon decay products (RDP) and gamma (γ) radiation. Risks of leukemia from acute and high doses of γ-radiation are well-characterized, but risks from lower doses and dose-rates and from RDP exposures are controversial. Few studies have evaluated risks of other hematologic cancers in uranium workers. The purpose of this study was to analyze radiation-related risks of hematologic cancers in the cohort of Eldorado uranium miners and processors first employed in 1932–1980 in relation to cumulative RDP exposures and γ-ray doses. The average cumulative RDP exposure was 100.2 working level months and the average cumulative whole-body γ-radiation dose was 52.2 millisievert. We identified 101 deaths and 160 cases of hematologic cancers in the cohort. Overall, male workers had lower mortality and cancer incidence rates for all outcomes compared with the general Canadian male population, a likely healthy worker effect. No statistically significant association between RDP exposure or γ-ray doses, or a combination of both, and mortality or incidence of any hematologic cancer was found. We observed consistent but non-statistically significant increases in risks of chronic lymphocytic leukemia (CLL) and Hodgkin lymphoma (HL) incidence and non-Hodgkin lymphoma (NHL) mortality with increasing γ-ray doses. These findings are consistent with recent studies of increased risks of CLL and NHL incidence after γ-radiation exposure. Further research is necessary to understand risks of other hematologic cancers from low-dose exposures to γ-radiation. - Highlights: • We analyzed long-term follow-up for hematologic cancers of the Eldorado uranium workers. • Workers were exposed to a unique combination of radon decay products (RDP) and gamma (γ) ray doses. • Exposures to RDP and γ-ray doses were not associated with significantly increased risks of cancers. • Radiation risks of chronic lymphocytic leukemia (CLL) and Hodgkin lymphoma were increased. • Study findings provide additional support for radiation-related risks of CLL.

54 ENVIRONMENTAL SCIENCES↗

Radiation characterization summary :

This document presents the facility-recommended characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields in the Annular Core Research Reactor (ACRR) for the 44-inch-long lead-boron bucket in the central cavity on the 32-inch pedestal at the core centerline. The designation for this environment is ACRR-LB44-CC-32-cl. The neutron, prompt gamma-ray, and delayed gamma-ray energy spectra are presented as well as radial and axial neutron and gamma-ray flux profiles within the experiment area of the bucket. Recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. Representative pulse and steady-state operations are presented with conversion examples.

Quirk, Thomas J.↗

Benchmarking MCNP models to support gamma irradiation experiments

Seismic isolators and damping devices have been used for 30+ years to reduce seismic forces and deployed in 10,000+ structures, including bridges, buildings, and mission-critical infrastructure. Studies have shown that seismic isolation of nuclear power plants can reduce the seismic risk by several orders of magnitude and substantially reduce the overnight capital cost. Advanced reactor developers are considering seismic isolation as an integral design feature in their reactor design. It can either be deployed at the building level, isolating the entire reactor building, or at the component level, isolating individual pieces of safety-class equipment, such as a reactor vessel or a steam generator. For equipment isolation, located close to the reactor vessel, the seismic isolators and/or damping devices may be exposed to gamma and neutron radiation, with a possible effect on their mechanical properties which would affect the response of the isolated equipment under earthquake shaking. The Department of Energy, as part of its Nuclear Energy University Program (NEUP), in collaboration with the Idaho National Laboratory (INL), is funding a project at the University at Buffalo (UB) to investigate the effect of gamma radiation on the mechanical properties of various seismic protective devices. (When isolating equipment, the seismic protective devices will be located outside the reactor vessel where the neutron exposure will be insignificant.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Fissile Nuclei Rotation Effect in {sup 235}U(n,{gamma}f) Process

A small shift of an angular distribution of prompt {gamma}-rays relative to the fission axis of {sup 236}U* {sup 235}U(n,{gamma}f) process is presented. This effect has been observed in the experiment at BER-II reactor of BENSC/HMI (Berlin). The sign of the shift depends on the direction of the incident neutron beam polarization. This phenomena can be explained by the rotation of fissile nucleus {sup 236}U*, like the effect that has been observed recently at ILL in ternary fission of {sup 235}U by cold polarized neutrons. The main surprise of this result is the detection of scission gamma-rays radiated by a fissile nucleus during the time interval of the order of 10{sup -21} s before or after the moment of the neck rupture. Detailed measurements of trigger {gamma}-rays energy dependence are in progress at the neutron beam 'MEPHISTO' of FRM-II reactor (Garching)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron radiation shielding material polyethylene: consequences of gamma irradiation - 15062

High and ultra-high molecular weight polyethylenes are high performance materials, which are predestined for a wide range of applications due to characteristics like high density, low weight, good dimensional stability, high chemical resistance, and high hydrogen content. These polymers are used in two demanding areas: as implant material in medical technology (only ultra-high molecular weight polyethylenes) and as a component for neutron shielding purposes in casks for storage and transport of radioactive waste. In the medical field (joint replacements) as well as during neutron radiation shielding application, high and ultra-high molecular weight polyethylenes are exposed to gamma irradiation: in the first case requested as sterilization process and for surface-crosslinking and in the second case existing as a side effect of inserting the radioactive material in the cask. Given that polyethylene as shielding material has to withstand any type of degradation affecting safety relevant aspects to be applicable for long-term radiation shielding purposes for instance over a period of 40 years, the durability of the material is of special interest. High molecular weight polyethylene (HMW-PE; LUPOLEN 5261Z; Lyondell Basell) and ultra-high molecular weight polyethylene (UHMW-PE; GUR 4120; Ticona) were subjected to gamma radiation and afterwards thermally treated. The gamma doses used are in the range of 50 to 600 kGy and irradiation takes place at RT using a Co-60 source. The planned thermal treatment will take place at a temperature of 125 deg.C for periods of minimum 30 days and maximum of five years. With the applied conventional analytical techniques it is possible to detect structural changes of both types of polyethylene induced by gamma irradiation and certainly of thermal treatment. Through gamma irradiation melting temperature, crystallinity, and density, respectively increased. Furthermore both polyethylenes get oxidized and cross-linked. With regard to the special application as neutron radiation shielding material in casks for storage and transport of radioactive materials, the impact of irradiation lead to changes of material properties. A consolidated view indicates that the detected changes of the irradiated (U)HMW-PE are not safety relevant for long-term neutron radiation shielding purposes over a period of 40 years in Germany. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗