Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fossil Fuel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Cost and Performance Baseline for Fossil Energy Plants Supplement: Sensitivity to CO 2 Capture Rate In Coal-Fired Power Plants

The cost and performance of various plants designed to meet a range of carbon dioxide (CO 2 ) emission limits are evaluated in this report by varying the CO 2 capture rate. The base cases for these designs are the supercritical (SC) pulverized coal (PC) plant and the General Electric Power (GEP) integrated gasification combined cycle (IGCC) plant from the Department of Energy (DOE) National Energy Technology Laboratory (NETL) report “Cost and Performance Baseline for Fossil Energy Plants, Volume 1: Bituminous Coal and Natural Gas to Electricity, Revision 4” (“Bituminous Baseline”).

20 FOSSIL-FUELED POWER PLANTS↗

Advancing Pressure Gain Combustion for Terrestrial Turbine Systems

The principal objectives of this project were to demonstrate the operability of a natural gas - air RDE at gas turbine engine cycle conditions. To achieve these goals, our specific tasks were to 1) characterize the dynamic injection and mixing performance of candidate injectors, 2) assess the engine operability via interrogation of spatio-temporal dynamics of combustor inlet and exit flows, 3) measure the engine emissions, and 4) complete an overall assessment of the pressure gain potential of the device. In order to advance RDE technology to the greatest extent possible, the reactants and experimental conditions were chosen to replicate combustor and injector conditions in a terrestrial power generation system. This path was taken because the scaling of combustion devices is, in general, an immature area given the challenges of interrelated mixing and chemical kinetics processes both of which scale with operating conditions.

03 NATURAL GAS↗

Novel CO 2 -Selective Membranes for CO 2 Capture from <1% CO 2 Sources

The objective of this project is to develop a cost-effective design and fabrication process for a new membrane and its membrane modules that capture CO 2 from <1% CO 2 concentration sources. Synthesis of novel CO 2 -selective membranes using a cost-effective nanoporous polyethersulfone (PES) polymer support and coating a top layer of thin, highly selective, yet permeable amine-containing polymer membrane has been performed. Pilot-size membranes (about 14 inches in width, the change was made from lab-size membranes with about 6 inches by 6 inches to gain more progress) have been used to fabricate at least 3 pilot-size membrane modules (each about 14-inch long) for lab testing with the simulated gas mixture. The pilot membrane modules have been in commercial configurations, i.e., plate-and-frame (PF) and spiral-wound (SW), for a minimal pressure drop (<0.103 bar/meter (1.5 psi (pounds per square inch)/meter)). Both PF and SW modules fabricated gave similar performance and acceptable pressure drop results. We down-selected to the SW module for ease of manufacture.

2-stage process↗

Enabling 10mol/kg Swing Capacity via Heat Integrated Sub-ambient Pressure Swing Adsorption

This project focused on the development of a post-combustion CO 2 capture technology for coal-fired power stations. The core concept of the technology was the combination of an adsorption-based separation with combustion flue gas cooling, compression followed by heat and power recovery. The key features of the adsorption unit (which captures and purifies the CO 2 ) are the use of high flow fiber-based adsorption systems that incorporate materials that manage the significant amounts of heat released during the adsorption separation. The adsorbent material utilized was a hybrid organic-inorganic material (a metal-organic framework) that had the proper combination of separation selectivity and CO 2 capture capacity. In this case, record-setting, process-relevant CO 2 capture capacities (approximately 8-10 mol of CO 2 per kg of adsorbent “swing capacities”) were observed in experimental measurements of the adsorptive separation. The experimental work was accompanied by detailed multi-level simulation works, which investigated the molecular mechanism for the high CO 2 capture efficiencies, the heat and mass transport dynamics within the separation system, and the process-level integration of the various systems associated with the technology. Overall, the analysis conducted in this work indicates that this technology can potentially reach CO 2 capture costs as low as 40-50 dollars/tonne with capital costs of 250M-400M dollars for the 550 MW e basecase established by the National Energy Technology Laboratory.

20 FOSSIL-FUELED POWER PLANTS↗

High Fidelity Computational Model for Fluidized Bed Experiments (Final Report)

MFiX was integrated with preconditioners and linear solver packages in Trilinos via MFIX, Fortran, C, and C++ wrappers. The MFIX wrapper interpreted the structure of the matrix and vector from MFiX while the Fortran wrapper transfers this information to a low-level language, C. C-wrapper transforms the memory semantic between Fortran and C++ language. C++ wrapper passes the matrix and vector to a Trilinos package and gets the solution. This solution was transferred to MFiX via C++, C, Fortran, MFIX wrapper. The framework is used to integrate first, second and third generation linear solvers in Trilinos with MFiX.

20 FOSSIL-FUELED POWER PLANTS↗

O 2 Binding Materials and highly Efficient Modular System for Oxygen Production

The overall objective of this project was to develop innovative oxygen separation materials and technologies based on using oxygen carriers in solid form to reversibly bind oxygen for efficient separation of air to produce greater than 95% purity of oxygen (O 2 ). These materials were then be made into solid adsorbents and membranes for O 2 production processes. The goal of this technology development project was to achieve a bed-factor of less than 600 lb-sorbent/TPD O 2 (tons/day O 2 ) for solid adsorbents, an O 2 /N 2 separation factor greater than 20 for membranes, and O 2 purity greater than 95% at a cost that is projected to be significantly lower than the current state-of-the-art (SOTA) small-scale, commercially available, stand-alone air separation systems. The project team performed a design case for a modular system to produce 10 TPD 95% O 2 and evaluate the cost of O 2 production using such a system.

20 FOSSIL-FUELED POWER PLANTS↗

Large Bench-Scale Development of a Non-Aqueous Solvent (NAS) CO 2 Capture Process for Coal-Fired Power Plants Utilizing Real Coal-Derived Flue Gas (Final Report)

This advanced non-aqueous solvent (NAS) technology led by RTI International in collaboration with Norwegian research organization SINTEF and industry partner Linde LLC, represents a disruptive advance in carbon capture to meet the Department of Energy’s critical mission to lower the cost associated with reducing carbon emissions from existing coal-fired power plants. This technology may reduce the energy required to remove carbon dioxide from flue gas by approximately 50%, decreasing the cost of carbon capture by 35% compared to earlier technologies. This report shows the results from testing at SINTEFs demonstration facility in Tiller, Norway.

20 FOSSIL-FUELED POWER PLANTS↗

Large Bench-Scale Development of a Non-Aqueous Solvent (NAS) CO2 Capture Process for Coal-fired Power Plants Utilizing Real Coal-Derived Flue Gas

In this project RTI tested its non-aqueous solvent (NAS) technology at larger scale in collaboration with Norwegian research organization SINTEF and industry partner Linde LLC. NAS represents a disruptive advance in CO 2 capture to meet the Department of Energy’s critical mission to lower the cost associated with reducing CO 2 emissions from existing coal-fired power plants. This technology may reduce the energy required to remove CO 2 from flue gas by approximately 50%, decreasing the cost of CO 2 capture by 35% compared to earlier technologies. The results of testing are shown in this report.

20 FOSSIL-FUELED POWER PLANTS↗

Preliminary Assessment of Post-Combustion Capture of Carbon Dioxide at the San Juan Generating Station [Draft]

This is a preliminary technical assessment of a proposal to retrofit the San Juan Generating Station in New Mexico, capturing the carbon dioxide (CO 2 ) generated by the power plant and transporting it via pipeline to the Permian Basin in Texas for use in CO 2 enhanced oil recovery (CO 2 -EOR). The assessment was conducted for the U.S. Department of Energy and relies on publicly available information, including a pre-feasibility study developed by Enchant Energy in partnership with Sargent & Lundy. It is focused on technical aspects of the project as related to the proposed capture of CO 2 , the proposed use/storage of CO2, and potential future options for use/storage of CO 2 in the Four Corners region.

02 PETROLEUM↗

A Guideline for the Assessment of Uniaxial Creep and Creep-Fatigue Data and Models

Of primary concern to FE practitioners is a determination of which constitutive models are the “best”, capable of reproducing the mechanisms expected in an intended design accurately; as well as what experimental datasets are proper or “best” to use for fitting the constitutive parameters needed for the model(s) of interest. In addition, the inherent uncertainty in experiments and the repeatability and stability of extrapolations (for long-lived FE components) is a major concern. The goal of this project is to develop a guideline for the assessment of uniaxial creep and creep-fatigue data and models. The research objectives are RO1) develop an aggregated database of creep and creep-fatigue data for P91 steel and 316 stainless steel and perform a systematic assessment of the uncertainty and integrity of the datasets. RO2) employ the database to benchmark existing creep and creep-fatigue models to evaluate the model’s ability to predict standard and nonstandard boundary conditions.

20 FOSSIL-FUELED POWER PLANTS↗

AOI2 - Initial Engineering, Testing, and Design of a Commercial-Scale Postcombustion CO 2 Capture System on an Existing Coal-Fired Generating Unit (Project Carbon)

The continued long-term use of North Dakota lignite is likely dependent on creating a business case for carbon capture, utilization, and storage (CCUS) that also addresses society’s desire to reduce carbon emissions. CCUS coupled with enhanced oil recovery appears to be the most feasible option for utilities to sustain and grow the lignite industry. Establishing a market where lignite-powered utilities provide carbon dioxide (CO 2 ) to oil producers depends upon having a cost-effective method to capture CO 2 . The application of CO 2 capture technology to lignite-fired flue gas has challenges in addition to the cost of capture, including the effects of the buildup of heat-stable salts, aerosol formation, degradation of solvents or solid sorbents, or subsequent solvent loss. Lignite, especially North Dakota lignite, presents its own set of challenges that include the combination of high sodium, sulfur, and ash contents; NO x reduction; and footprint limitations. Project Carbon was designed to address these technical barriers and provide pre-FEED (preliminary front-end engineering and design) information necessary for additional commercial demonstrations to move forward. A long-term pilot-scale evaluation of Mitsubishi Heavy Industries’ (MHI’s) KS-1™ solvent at Minnkota Power Cooperative’s lignite-fired Milton R. Young Station Unit 2 (MRY2) was a major objective of the project. The purpose of the test was to demonstrate the technology’s compatibility with MRY2’s flue gas over an extended period of time. During the long-term test, aerosol sampling and measurement were performed, and a pilot-scale baghouse was tested to determine the effect of bag material and operation on aerosol concentrations in the flue gas. Project engineering and design work were performed to support the other major project objective: a pre-FEED study of CO 2 capture at MRY2. Finally, a techno-economic assessment (TEA) of the application of CO 2 capture to MRY2 was performed. This project was performed over a period of 28 months, with a total budget of $12,700,000. The U.S. Department of Energy’s (DOE’s) National Energy Technology Laboratory, through the Energy & Environmental Research Center’s (EERC’s) Cooperative Agreement, the North Dakota Industrial Commission, and industry partners ALLETE and Minnkota Power Cooperative, funded the project. The pilot-scale test system at MRY2 performed very well for the continuous test period of 83 days. The CO 2 capture plant achieved stable operation while utilizing MHI’s KS-1™ solvent and the MHI amine emission reduction unit. No major concerns were encountered when capturing CO 2 from lignite-fired flue gas. Challenges were encountered because the cooling water temperature was warmer than needed for the capture system to operate efficiently. This affected the ability of the solvent to capture CO 2 and promoted solvent loss through solvent entrainment caused by high CO 2 gas temperature within a cyclone separator. The KS-1™ solvent and the lignite-derived flue gas were analyzed during the long-term test. Analysis of the solvent indicates that, although some metals and heat-stable salts increased over the course of the long-term test, they were at levels that can be treated with filtration and reclaiming and do not pose a concern for effective solvent operation. Fourier transform infrared (FTIR) spectrometry was successfully used to determine the composition of the lignite-derived flue gas as well as concentrations of select components of the flue gas at various locations within the EERC’s CO 2 capture system. The formation of aerosols during the capture process is of interest, as are approaches for their reduction, especially in a baghouse. Testing of aerosol removal was performed using the EERC’s portable baghouse. It was found that both Ryton and polytetrafluoroethylene (PTFE) membrane bags were effective at reducing the level of aerosols during steady-state operation. During backpulse events, however, the amount of aerosols passing through the bags was an order of magnitude lower for the Ryton bags than the PTFE membrane bags. The testing showed that proper design of the baghouse air-to-cloth ratio as well as minimization of backpulsing can dramatically reduce the amount of aerosols that pass through the bags and remain in the flue gas stream exiting a baghouse system. A technology maturation plan (TMP) was performed to enable successful development of the Kansai Mitsubishi Carbon Dioxide Recovery® (KM CDR®) Process for application to a combustion flue gas for which the process has not yet been demonstrated. In the TMP, new challenges to the MHI CO 2 capture technology during its application to MRY2 were identified. These challenges included capture from lignite-fired (as opposed to subbituminous coal-fired) flue gas, a larger scope than previous applications of the technology, and implementation in a colder climate that could affect process and equipment operability. Because MRY2 is located where stack icing in the winter could be problematic, a rime icing study was performed. Rime icing modeling indicated that, under both 100% and 50% operating loads, there is a potential for many icing events during any given part of the year in which below-freezing weather conditions exist. The models showed that a critical amount of rime ice could be formed at the stack top during two or more events per year. CO 2 capture plant stack height and location will need to be determined in order to minimize the formation of rime ice. It was found that the integration of the MHI CO 2 capture process into the normal operation of the MRY2 steam turbine is a viable alternative to a cogeneration facility to provide steam and power for the carbon capture facility. The research performed under this project showed that CO 2 capture at a lignite-fired power plant can successfully be performed. No known fatal flaws that would prevent the continued development of the MRY2 CO 2 capture facility were identified during the pre-FEED study. A TEA performed following DOE methodology shows that applying capture technology to MRY2 may not only meet but exceed the DOE-recognized state-of-the-art baseline.

20 FOSSIL-FUELED POWER PLANTS↗

Design, Fabrication and Performance Characterization of Near-Surface Embedded Cooling Channels with an Oxide Dispersion Strengthened (ODS) Coating Layer

The primary goal of this research is to develop an innovative approach to provide an immensely improved level of thermal protection for hot-section components, such as turbine airfoils, in modern and future gas turbines. Current and future designs for advanced turbine systems, such as IGCC, advanced Natural Gas Combined Cycle (NGCC), and the emerging supercritical CO 2 (SCO 2 ) systems, are targeting turbine inlet temperatures well beyond the substrate melting temperature, typically ranging from ~ 1400°C-1800°C. Meanwhile, targeted cycle efficiency calls for a reduction of the amount of coolant air significantly below the current level. Hence the development of novel internal airfoil designs that provide a satisfactory level of component durability with affordable coolant management is critical to the further advances of today’s turbine technology. This proposal is a response to this grand challenge.

03 NATURAL GAS↗

Continuous Water Quality Sensing for FGD Wastewater

The coal fired plant power industry requires new solutions for on-line monitoring of flue gas desulfurization (FGD) wastewaters for regulated trace metals to reduce recurring operating and off-site laboratory analysis costs and provide a high level of confidence of compliance with state and federal discharge guidelines. The University of Alabama at Birmingham (UAB) developed an integrated water sensor package for continuous water quality monitoring of flue gas desulfurization (FGD) wastewaters for concentration measurements of Selenium (Se). UAB utilized a diverse team of University Professors/Staff Members/Student(s) (Engineering and Innovative Technology Development Group), a University Affiliated Research Institution from the local area (Southern Research), and a cost sharing Industry Partner (Metrohm). The team developed and validated a proprietary wet chemistry batch process for water sample preparation; and implemented this process as a fully automated on-line monitor prototype system. This prototype system’s performance was evaluated in both the laboratory and during in-field deployment to a coal fired power plant. In both environments it was found that the prototype system was unable to recreate the batch process’s success at preparing FGD water samples for total Se measurements with a commercial-off-the-shelf (COTS) cyclic anodic stripping voltammetry (CSV) system. Through this experience, UAB has provided insight into a number of specific areas where improvements can be made with respect to the COTS systems used in this project to yield a more complete and competitive industry solution for on-line monitoring of total Se in industrial wastewater.

01 COAL, LIGNITE, AND PEAT↗

ICME for Creep of Ni-Base Superalloys in Advanced Ultra-Supercritical Steam Turbines

The goal of this project contains three major aspects: (1) critical assessment of existing experimental data, (2) critical assessment of existing modeling capabilities and (3) development of new modeling capabilities that are critical but currently missing in predicting long-term creep behavior of Ni-base superalloys used in advanced ultra- supercritical (A-USC) steam turbines for coal-fired power plants. The project uses advanced materials informatics to datamine the experimental data, uncertainty quantification tools to rigorously assess existing creep-life models, and integration of phase-field and FFT-based crystal plasticity to develop a multi-scale, physics-based, microstructure-sensitive creep model.

20 FOSSIL-FUELED POWER PLANTS↗

Advanced sorbents for modular oxygen production for REMS gasifiers

Under a DOE funded effort, Thermosolv LLC has been developing a sorbent-based oxygen production technology for gasification and oxy-combustion applications. The sorbents utilize oxygen-storage properties of certain perovskites to (1) selectively adsorb oxygen at moderate temperature from compressed air and (2) release the adsorbed oxygen into a vacuum or a sweep gas such as CO2 and/or steam. Through cyclic operations of multiple sorbent beds such a process can be made continuous. Pressure drop across the sorbent bed and other similar design considerations dictate that the sorbent be in the form of a high surface-area-to-volume pellet and yet still possess sufficient crush strength and integrity. Process efficiency is determined by the sorption and desorption kinetics and sorbent capacity. Typical process involves cycle times in the order of 100 seconds, a time too short to fully utilize the full volume of the sorbent and the sorption capacity of the sorbent pellets. As a part of this project, Thermosolv LLC undertook the development of oxygen sorbents as a high-surface area supported sorbent on a light-weight inert support to (1) reduce the cost, (2) increase the productivity, and (3) reduce the overall weight of the reactor. Using a previously developed perovskite (LSCF 1991) with its well-characterized performance, composite sorbent pellets each consisting of an inert core coated by a thin layer of the functional perovskite material were produced. Several low-density, inexpensive inert solids supports in the 1/8”-1/4” size were selected to keep the pressure drop across the sorbent bed in the acceptable range. A number of commercial technologies including spray coating, dip coating, incipient impregnation of porous substrate followed by thermal annealing at various temperatures and duration were employed and tested to produce robust composite supported sorbent pellets. A sense of optimum coating thickness was developed by testing sorbent pellets of various increasing diameter pellets. LSCF-1991extrudates ranging in size from 1/32” to 3/16” were tested in a TGA and in a fixed-bed pressure swing test set-up for sorption/desorption cycles of interest. The data show that for the operational conditions of interest the coating thickness for a supported sorbent pellet needs to be approximately 1/32” (about 0.8 mm). Subsequent work thereby concentrated on developing composite pellets of various substrates, shapes and sizes with coating layer of about this size range. Candidate support materials were chosen based on cost, inertness, mechanical strength, thermal expansion and chemical stability with sorbent material, and in a size range to give an acceptable pressure drop in fixed-bad reactor configurations. Coating application methods used for application of the sorbent onto the support included precipitation, spray coating and dip coating from sorbent slurries and sol gels. For all coated supports where we could successfully apply a uniform coating of desired thickness with an acceptable handling performance in terms of exfoliation, TGA-based cyclic sorption/desorption testing was performed to determine cycling capacity of oxygen. Among nearly twenty different support materials tested, best adhesion performance was obtained from stainless saddle supports. In the bench-scale fixed-bad tests stainless steel saddle support composite pellets with a coating thickness in the 0.6 mm or so range, the composite sorbent pellet performance approached up to 95% of that of the 2 mm parent material pellets. In a parallel approach to reducing the cost of the sorbent, alternate sorbent formulations replacing/reducing the amount of cobalt in the LSCF family were also investigated. Successful formulations that could match the performance of LSCF 1991 were identified based on TGA cyclic tests as LSCF 1919 and LSF 1910. In the range of operational envelop of cycle times and other relevant process operating conditions, the reduced Co formulations showed comparable performance in the bench-scale fixed-bad cyclic operations. As a part of this project, we also attempted substitution of La and Sr with Ca and Ba, and Co with Mn, Ni and Cu with little success, but the overall project goal of reducing sorbent cost in terms of raw material and manufacturing expenses was successful.

01 COAL, LIGNITE, AND PEAT↗

Abstract for CRADA among the National Energy Technology Laboratory, National Technology & Engineering Solutions of Sandia, The Regents of the University of California, and Tri-State Generation and Transmission Association, Inc. (AGMT-0855)

The objective of this CRADA is to facilitate cooperation among Tri-State Generation and Transmission Association, Inc. and collaborators of the Institute for the Design of Advanced Energy Systems (IDAES), including the National Energy Technology Laboratory, Sandia National Laboratories, and Lawrence Berkeley National Laboratory. The goal is to develop steady-state and dynamic optimization models of power plants. Tri-State will provide data related to the design and operation of power plants, which will be used to validate the IDAES team’s models and tools. These models will provide insight into potential improvements which could improve heat rate, reduce operations and maintenance costs, and/or improve reliability of the existing fleet of coal plants in the United States.

20 FOSSIL-FUELED POWER PLANTS↗

Sorption Enhanced Mixed Matrix Membranes for Hydrogen (H 2 ) Purification and Carbon Dioxide (CO 2 ) Capture

The technical objective of this project was to develop sorption enhanced mixed matrix membranes with H 2 permeance of 500 gas permeance units (GPU) and H 2 /CO 2 selectivity of 30 at 150-200 °C. These membranes will be the central component in the design of membrane based systems for 90% capture of CO 2 from coal-derived syngas, with 95% CO 2 purity at a cost of electricity 30% less than baseline capture approaches. The unique approach in this proposal is to design crosslinked polymers containing Pd-based nanoparticles achieving strong H 2 sorption and size sieving ability and thus H 2 /CO 2 selectivity. The specific objectives for each budget period (BP) are described below. BP 1: Identify polymer matrix with strong size sieving ability and palladium (Pd)-containing nanomaterials to prepare freestanding mixed matrix films with H 2 permeability of 50 Barrer and H 2 /CO 2 selectivity of 30 at 150-200°C with simulated syngas. BP 2: Prepare and optimize thin film mixed matrix composite membranes materials with H 2 permeance of 500 GPU and H 2 /CO 2 selectivity of 30 at 150-200 °C, and complete the modification of the membrane test unit for the field test in the BP 3. BP 3: Conduct a 20-day field test of the membranes with real syngas at Center for Advanced Energy Research (CAER) of the University of Kentucky (UKy). During the BP2, we have successfully prepared thin-film composite (TFC) membranes based on mixed matrix materials (MMMs) containing Pd nanoparticles in polymers, and demonstrated their superior and robust performance for H 2 /CO 2 separation at 150 – 225 °C. (1) Production of the Pd based nanoparticles with a diameter of 4 nm has been scaled up to 200 mg/day. (2) We have prepared TFC membranes with H 2 permeance above 500 GPU and H 2 /CO 2 selectivity above 30 at temperatures up to 225 °C, which meet the targets for the BP2. (3) We have conducted parametric studies of TFC membranes with a mixed gas containing H 2 S and H 2 O and demonstrated the stability of the membranes. (4) We have established a new testing plan at the Center for Advanced Energy Studies (CAER) at the University of Kentucky because NCCC decided to shut down their gasifier. During this project, four Ph.D. students received the inter-disciplinary training and graduated, including Shailesh Konda, Maryam Omidvar, Deqiang Yin, and Lingxiang Zhu. One postdoctoral researcher (Dr. Liang Huang) and two Ph.D. students (Abhishek Kumar and Hien Nguyen) are involved in this project. The project leads to one provisional patent application, eight peer-reviewed articles, and one manuscript in preparation. The details are shown below.

01 COAL, LIGNITE, AND PEAT↗