Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fluid System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

High pressure mechanical seal

A relatively impervious mechanical seal is formed between the outer surface of a tube and the inside surface of a mechanical fitting of a high pressure fluid or hydraulic system by applying a very thin soft metal layer onto the outer surface of the hard metal tube and/or inner surface of the hard metal fitting, prior to swaging the fitting onto the tube. The thickness of such thin metal layer is independent of the size of the tube and/or fittings. Many metals and alloys of those metals exhibit the requisite softness, including silver, gold, nickel, tin, platinum, indium, rhodium and cadmium. Suitably, the coating is about 0.0025 millimeters (0.10 mils) in thickness. After swaging, the tube and fitting combination exhibits very low leak rates on the order or 10.sup.-8 cubic centimeters per second or less as meaured using the Helium leak test.

Babel, Henry W.↗

High pressure mechanical seal

A relatively impervious mechanical seal is formed between the outer surface of a tube and the inside surface of a mechanical fitting of a high pressure fluid or hydraulic system by applying a very thin soft metal layer onto the outer surface of the hard metal tube and/or inner surface of the hard metal fitting. The thickness of such thin metal layer is independent of the size of the tube and/or fittings. Many metals and alloys of those metals exhibit the requisite softness, including silver, gold, tin, platinum, indium, rhodium and cadmium. Suitably, the coating is about 0.0025 millimeters (0.10 mils) in thickness. After compression, the tube and fitting combination exhibits very low leak rates on the order or 10.sup.-8 cubic centimeters per second or less as measured using the Helium leak test.

Babel, Henry W.↗

Thermal Control System Development to Support the Crew Exploration Vehicle and Lunar Surface Access Module

All space vehicles or habitats require thermal management to maintain a safe and operational environment for both crew and hardware. Active Thermal Control Systems (ATCS) perform the functions of acquiring heat from both crew and hardware within a vehicle, transporting that heat throughout the vehicle, and finally rejecting that energy into space. Almost all of the energy used in a space vehicle eventually turns into heat, which must be rejected in order to maintain an energy balance and temperature control of the vehicle. For crewed vehicles, Active Thermal Control Systems are pumped fluid loops that are made up of components designed to perform these functions. NASA has recently evaluated all of the agency s technology development work and identified key areas that must be addressed to aid in the successful development of a Crew Exploration Vehicle (CEV) and a Lunar Surface Access Module (LSAM). The technologies that have been selected and are currently under development include: fluids that enable single loop ATCS architectures, a gravity insensitive vapor compression cycle heat pump, a sublimator with reduced sensitivity to feedwater contamination, an evaporative heat sink that can operate in multiple ambient pressure environments, a compact spray evaporator, and lightweight radiators that take advantage of carbon composites and advanced optical coatings.

Anderson, Molly↗

Groundwater Remediation and Alternate Energy at White Sands Test Facility

White Sands Test Facility Core Capabilities: a) Remote Hazardous Testing of Reactive, Explosive, and Toxic Materials and Fluids; b) Hypergolic Fluids Materials and Systems Testing; c) Oxygen Materials and System Testing; d) Hypervelocity Impact Testing; e)Flight Hardware Processing; and e) Propulsion Testing. There is no impact to any drinking water well. Includes public wells and the NASA supply well. There is no public exposure. Groundwater is several hundred feet below ground. No air or surface water exposure. Plume is moving very slowly to the west. Plume Front Treatment system will stop this westward movement. NASA performs on-going monitoring. More than 200 wells and zones are routinely sampled. Approx. 850 samples are obtained monthly and analyzed for over 300 different hazardous chemicals.

Fischer, Holger↗

Environmental Program

NASA's White Sands Test Facility has six core environmental compliance capabilities: remote hazardous testing of reactive, explosive and toxic materials and fluids; hypergolic fluids materials and systems testing; oxygen materials and system testing; hypervelocity impact testing; flight hardware processing; and, propulsion testing. The facility's permit status and challenges are reviewed. Historic operations and practices dating from the 1960s through the early 1980s resulted in contamination of the facility's groundwater. An environmental restoration effort has been employed to protect public health and the health of the workforce. The restoration seeks to properly handle hazardous materials and waste processes; determine the nature and extent of the contamination; stop the migration of contaminated groundwater; stabilize the plume front which has been assessed as the greatest risk to public health; and, clean-up the environment to restore it to preexisting conditions. The Plume Front Treatment System is operational and seeks to stop the westward movement of the plume to protect drinking water and irrigation well. Specifically, the treatment system will extract contaminated water from the aquifer, remove chemical using the best available technology, and return (inject) the treated water back to the aquifer. The Mid-Plume Interception Treatment System also seeks to stop the migration of containment, as well as to evaluate new technologies to accelerate cleanup, such as bioremediation.

Fischer, Holger↗

Stochastic Representation of Chaos Using Terminal Attractors

A nonlinear version of the Liouville equation based on terminal attractors is part of a mathematical formalism for describing postinstability motions of dynamical systems characterized by exponential divergences of trajectories leading to chaos (including turbulence as a form of chaos). The formalism can be applied to both conservative systems (e.g., multibody systems in celestial mechanics) and dissipative systems (e.g., viscous fluids). The development of the present formalism was undertaken in an effort to remove positive Lyapunov exponents. The means chosen to accomplish this is coupling of the governing dynamical equations with the corresponding Liouville equation that describes the evolution of the flow of error probability. The underlying idea is to suppress the divergences of different trajectories that correspond to different initial conditions, without affecting a target trajectory, which is one that starts with prescribed initial conditions.

Zak, Michail↗

Cardiac and Vascular Responses to Thigh Cuffs and Respiratory Maneuvers on Crewmembers of the International Space Station

The transition to microgravity eliminates the hydrostatic gradients in the vascular system. The resulting fluid redistribution commonly manifests as facial edema, engorgement of the external neck veins, and a decrease in leg diameter. This experiment examined the responses to modified Valsalva and Mueller maneuvers measured by cardiac and vascular ultrasound (ECHO) in a baseline steady state and during preload reduction introduced with thigh occlusion cuffs used as a counter-measure device (Braslet cuffs) measured by cardiac and vascular ultrasound examinations. Methods: Nine International Space Station crewmember subjects (Expeditions 16 - 20) were examined in 15 experiment sessions 101 +/- 46.days after launch (mean +/- SD; 33 - 185). Twenty Seven cardiac and vascular parameters were obtained with/without respiratory maneuvers before and after tightening of the Braslet cuffs. Results: Non-physicians performed diagnostic-quality cardiac and vascular ultrasound examinations using remote guidance. Three of 27 combinations of maneuvers and Braslet or Braslet alone were identified as being significant changed when compared to baseline. Eleven of 81 differences between combinations of Mueller, Valsalva or baseline were significant and related to cardiac preload reduction or increase in lower extremity venous volume. Conclusions: Acute application of Braslet occlusion cuffs causes lower extremity fluid sequestration and exerts commensurate measurable effects on cardiac performance in microgravity. Ultrasound techniques to measure the hemodynamic effects of thigh cuffs in combination with respiratory maneuvers may serve as an invaluable tool in determining the volume status of the cardiac patient at the 'microgravity bedside'.

Hamilton, Douglas↗

Space Propulsion Research Facility (B-2): An Innovative, Multi-Purpose Test Facility

The Space Propulsion Research Facility, commonly referred to as B-2, is designed to hot fire rocket engines or upper stage launch vehicles with up to 890,000 N force (200,000 lb force), after environmental conditioning of the test article in simulated thermal vacuum space environment. As NASA s third largest thermal vacuum facility, and the largest designed to store and transfer large quantities of propellant, it is uniquely suited to support developmental testing associated with large lightweight structures and Cryogenic Fluid Management (CFM) systems, as well as non-traditional propulsion test programs such as Electric and In-Space propulsion. B-2 has undergone refurbishment of key subsystems to support the NASA s future test needs, including data acquisition and controls, vacuum, and propellant systems. This paper details the modernization efforts at B-2 to support the Nation s thermal vacuum/propellant test capabilities, the unique design considerations implemented for efficient operations and maintenance, and ultimately to reduce test costs.

Hill, Gerald M.↗

Validation of On-Orbit Methodology for the Assessment of Cardiac Function and Changes in the Circulating Volume Using "Braslet-M" Occlusion Cuffs

BACKGROUND: The transition to microgravity eliminates the hydrostatic gradients in the vascular system. The resulting fluid redistribution commonly manifests as facial edema, engorgement of the external neck veins, nasal congestion, and headache. This experiment examined the responses to modified Valsalva and Mueller maneuvers as measured by cardiac and vascular ultrasound in a baseline microgravity steady state, and under the influence of thigh occlusion cuffs (Braslet cuffs). METHODS: Nine International Space Station crewmember subjects (Expeditions 16 - 20) were examined in 15 experiment sessions 101 46 days after launch (mean SD; 33 - 185). 27 cardiac and vascular parameters were obtained under three respiratory conditions (baseline, Valsalva, and Mueller) before and after tightening of the Braslet cuffs for a total of 162 data points per session. The quality of cardiac and vascular ultrasound examinations was assured through remote monitoring and guidance by Investigators from the NASA Telescience Center in Houston, TX, USA. RESULTS: Fourteen of the 81 measured conditions were significantly different with Braslet application and were apparently related to cardiac preload reduction or increase in the venous volume sequestered in the lower extremity. These changes represented 10 of the 27 parameters measured. In secondary analysis, 7 of the 27 parameters were found to respond differently to respiratory maneuvers depending on the presence or absence of thigh compression, with a total of 11 differences. CONCLUSIONS: Acute application of Braslet occlusion cuffs causes lower extremity fluid sequestration and exerts proportionate measurable effects on cardiac performance in microgravity. Ultrasound techniques measuring the hemodynamic effects of thigh cuffs in combination with respiratory maneuvers may serve as an effective tool in determining the volume status of a cardiac or hemodynamically compromised patient in microgravity.

Hamilton, D. R.↗

Decadal Polar Motion of the Earth Excited by the Convective Outer Core From Geodynamo Simulations

Long time geodetic observation records show that the orientation of the Earth's rotation axis with respect to the terrestrial reference frame, or polar motion, changes on a broad range of timescales. Apart from external torques from the luni-solar tides, these changes are excited by interactions among different components of the Earth system. The convective fluid outer core has long been conjectured a likely contributor to the observed polar motion on timescales upward of decades, such as the 30 year Markowitz wobble. We investigated the electromagnetic coupling scenario across the core-mantle boundary via numerical geodynamo simulation for different geodynamo parameters (Rayleigh numbers and magnetic Rossby numbers). Our simulated polar motion varies strongly with the dynamo parameters, while its excitation on decadal timescales appear to converge asymptotically within the adopted range of numerical Rossby numbers. Three strongest asymptotic modes emerge from numerical results, with periods around 30, 40, and 60 years for the prograde excitation and around 24, 30, and 60 years for the retrograde excitation. Their amplitudes are all larger than 5 times 10 (sup minus 8), or approximately 10 milliseconds of arc.The results suggest that the electromagnetic core-mantle coupling could explain a substantial portion, if not all, of the observed decadal polar motion. In particular, the predicted 60 year polar motion deserves special attention for future observations and studies.

Kuang, W.↗

Computational Techniques to Generate Space Launch System Aerodynamic Databases

This document describes the reasoning and trade studies used to evaluate tools for constructing the aerodynamic lineload databases for the liftoff and transition phases of flight for the Space Launch System. Three computational fluid dynamics codes (USM3D, FUN3D, Kestrel) were investigated with various turbulence models, as well as detached eddy simulation variants for the launch vehicle in free air and in proximity to the tower. Decisions were made mostly based on results from brief developmental studies performed in response to specific, unforeseen challenges that were encountered in the analysis of a given configuration. The need to develop databases in a timely manner, as well as accurately capture the expected leeward-wake flowfield characteristics, led to the selection of the Kestrel flow solver with its delayed detached eddy simulation method, the Spalart-Allmaras turbulence model, and the adaptive mesh refinement capability in the off-body Cartesian grid region.

Karen A. Deere↗

Coaxial microreactor for particle synthesis

A coaxial fluid flow microreactor system disposed on a microfluidic chip utilizing laminar flow for synthesizing particles from solution. Flow geometries produced by the mixing system make use of hydrodynamic focusing to confine a core flow to a small axially-symmetric, centrally positioned and spatially well-defined portion of a flow channel cross-section to provide highly uniform diffusional mixing between a reactant core and sheath flow streams. The microreactor is fabricated in such a way that a substantially planar two-dimensional arrangement of microfluidic channels will produce a three-dimensional core/sheath flow geometry. The microreactor system can comprise one or more coaxial mixing stages that can be arranged singly, in series, in parallel or nested concentrically in parallel.

47 OTHER INSTRUMENTATION↗

Laser bottom hole assembly

There is provided for laser bottom hole assembly for providing a high power laser beam having greater than 5 kW of power for a laser mechanical drilling process to advance a borehole. This assembly utilizes a reverse Moineau motor type power section and provides a self-regulating system that addresses fluid flows relating to motive force, cooling and removal of cuttings.

42 ENGINEERING↗

Hybrid Optimization Software Suite

The hybrid optimization software suite (HOSS) is a general purpose fully 2D/3D parallel combined finite discrete element (FDEM) code that can be used to simulate problems involving fracture and fragmentation processes, large deformation and large rotations, discrete particle systems, solid-fluid interaction in hydro fracture problems, etc. HOSS uses a hybrid approach that combines finite-element and discrete-element methods with a novel computational fluid dynamics solver. The finite-element method is often used to analyze a material or object and how it responds to stress. The discrete-element method analyzes stresses and displacements in a volume containing a large number of particles, such as grains of sand. Fluid dynamics analyzes the fluid flow inside, around, or through solid domains. With these processes combined, HOSS represents a paradigm shift when it comes to generating accurate simulations of material deformations and failure. HOSS can perform the following: Resolves problems that consist of millions of deforming fracturing, and interacting solid particles; Requires no coupling—it naturally integrates with all regimes of fluid flow; Resolves all regimes of fluid flow, such as Stokes, low/high Reynolds, subsonic/transonic/supersonic/hypersonic, compressible/incompressible, viscid/inviscid, Newtonian/Non-Newtonian and turbulent/laminar flow; Combines all flow regimes in the same solver; Numerically stable for all flow regimes; Naturally combines different flow regimes in the same problem; Possesses material library for fluid behavior; Naturally matches fluid solver to solid solver; Includes non-inertial Eulerian formulation for fluids; Uses highly efficient parallel computing based on the Virtual Parallel Machine, thus enabling easy porting between different parallel architectures, including possible future architectures; Designed specifically for multi-physics problems in research and industry in virtual experimentation format, thereby complementing both theoretical-computational and experimental tools; Can be extended to address millions of deforming solid particles immersed in fluid flowing at all regimes; Can be extended to address biological applications, such as modeling bone fracture or red blood cells in blood plasma

Knight, Earl E.↗

Self-healable coatings and methods of making the same

A robust and self-healing coating has been developed by incorporating a thermally self-healing chemical coating on smooth and/or roughened solid. When the chemically coated solid is combined with a lubricating fluid, the material system is capable to repel a broad range of liquids and solids. The thermally self-healing chemical coating may be applied on various industrial metals, glass and plastics, and has shown exceptionally physical and chemical robustness as compared to state-of-the-art liquid-repellent coatings.

Wang, Jing↗

Thermal Stratification Modeling and Analysis for Sodium Fast Reactor Technology

General discussion of thermal hydraulic phenomenon present in sodium fast reactors during known reactor transients. Specifically, this research focuses on presenting research focused on modeling thermal stratification in the upper plenum of a sodium fast reactor. An experimental facility was built to provide validation for both computational fluid dynamic and system code analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High-Temperature Stability of Aqueous Foams as Potential Waterless Hydrofracking Fluid for Geothermal Reservoir Stimulation

Hydraulic fracturing is the process of fracturing rock formations with high-pressure water-based fluids. In Enhanced Geothermal Systems (EGS) hydraulic fracturing is carried out by injecting high-pressure fluids into the Hot Dry Rocks (HDR) under carefully controlled conditions. The fluid used for fracturing is an important component for EGS, not only concerning the technical approch but also environmental impact. Recent research has been carried out to develop waterless fracturing technologies for EGS, including foam-based hydrofracking, where foams are mixtures of gas and liquid fluids. Foam fracturing fluids have potential benefits over water-based fluids because of less water consumption, less damage in water sensitive formations, and less liquid to recover and handle after fracturing process. One challenge for implementing foam fracturing in EGS is to achieve stable foams at high temperatures, as the foam stability tends to decay with increase in temperature.This research is focused on investigating the stability of foams at high temperatures. Preliminary results show that 1) N2 foams are more stable compared to CO2 foams, 2) foams containing only surfactants were not stable at high temperatures, and 3) addition of different stabilizing agents increased the thermal stability of all the foams. It was observed that different stabilizing agents interacted differently with anionic, nonionic, and cationic surfactants. It was further shown that the crosslinking agent with a base solution of pH 6 and graphene oxide dispersion was the most effective stabilizing agent for anionic surfactant AOS, while bentonite clay effectively enhanced thermal stability for another anionic surfactant SDS. SiO2 nanoparticles showed limited improvement in thermal stability at high temperatures compared to other stabilizing agents.

Thakore, Virensinh↗