Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Passivation layer breakdown during laser-fired contact formation for photovoltaic devices

Low resistance laser-fired ohmic contacts (LFCs) can be formed on the backside of Si-based solar cells using microsecond pulses. However, the impact of these longer pulse durations on the dielectric passivation layer is not clear. Retention of the passivation layer during processing is critical to ensure low recombination rates of electron-hole pairs at the rear surface of the device. In this work, advanced characterization tools are used to demonstrate that although the SiO{sub 2} passivation layer melts directly below the laser, it is well preserved outside the immediate LFC region over a wide range of processing parameters. As a result, low recombination rates at the passivation layer/wafer interface can be expected despite higher energy densities associated with these pulse durations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Keynote address: Reinventing fire: Physics + markets = energy solutions

Rocky Mountain Institute's multi-year, 61-author, peer-reviewed Reinventing Fire synthesis showed how the U.S. can realistically run a 2.6× bigger U.S. economy in 2050 with no oil, coal, or nuclear energy, one-third less natural gas, tripled efficiency, and 74% renewable supplies (80% for electricity). This transition, at historically reasonable rates, could be led by business for profit, applying normal rates of return, with some innovative subnational and administrative policies but no Acts of Congress. Excluding carbon emissions and all other externalities, the net present value would be $5 trillion more favorable than business-as-usual, averaging a 14% Internal Rate of Return.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Superconducting neural networks with disordered Josephson junction array synaptic networks and leaky integrate-and-fire loop neurons

Fully coupled randomly disordered recurrent superconducting networks with additional open-ended channels for inputs and outputs are considered the basis to introduce a new architecture to neuromorphic computing in this work. Various building blocks of such a network are designed around disordered array synaptic networks using superconducting devices and circuits as an example, while emphasizing that a similar architectural approach may be compatible with several other materials and devices. A multiply coupled (interconnected) disordered array of superconducting loops containing Josephson junctions [equivalent to superconducting quantum interference devices (SQUIDs)] forms the aforementioned collective synaptic network that forms a fully recurrent network together with compatible neuron-like elements and feedback loops, enabling unsupervised learning. This approach aims to take advantage of superior power efficiency, propagation speed, and synchronizability of a small world or a random network over an ordered/regular network. Additionally, it offers a significant factor of increase in scalability. Here, a compatible leaky integrate-and-fire neuron made of superconducting loops with Josephson junctions is presented, along with circuit components for feedback loops as needed to complete the recurrent network. Several of these individual disordered array neural networks can further be coupled together in a similarly disordered way to form a hierarchical architecture of recurrent neural networks that is often suggested as similar to a biological brain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Behavioral resilience via dynamic circuit firing homeostasis

Homeostatic regulation ensures stable neural circuit output under changing conditions. We find that in Drosophila larvae, either presynaptic weakening due to perturbation of transmitter release or postsynaptic weakening due to perturbation of glutamate receptors at synapses between motor neuron (MN) and muscle has little impact on locomotion, suggesting a nonsynaptic compensatory mechanism. In vivo imaging shows that five different forms of synaptic weakening increase the duration of activity bouts in type I MNs. Strikingly, this compensation is input selective: occurring only in the tonic type Ib MN, not the phasic type Is MN that innervates the same muscle. Moreover, an inhibitory class of central pre-MNs that innervates the tonic—but not phasic—input decreases in activity. The adjustment in activity occurs remarkably quickly: within minutes of synapse perturbation. We propose that MN firing is dynamically regulated by two coordinated mechanisms: a cell-autonomous adjustment of MN excitability and a circuit adjustment of inhibitory central drive. The input selectivity of this process suggests homeostatic adjustment to maintain tonic drive but hold constant the phasic drive that organizes locomotory wave patterns.

59 BASIC BIOLOGICAL SCIENCES↗

Combustion characteristics and NOx emissions of two kinds of swirl burners in a 300-MWe wall-fired pulverized-coal utility boiler

Measurements were performed in a 300-MWe wall-fired pulverized-coal utility boiler. Enhanced ignition-dual register (EI-DR) burners and centrally fuel rich (CFR) swirl coal combustion burners were installed in the bottom row of the furnace during experiments. Local mean concentrations of O{sub 2}, CO, CO{sub 2} and NOx gas species, gas temperatures, and char burnout were determined in the region of the two types of burners. For centrally fuel rich swirl coal combustion burners, local mean CO concentrations, gas temperatures and the temperature gradient are higher and mean concentrations of O{sub 2} and NOx along the jet flow direction in the burner region are lower than for the enhanced ignition-dual register burners. Moreover, the mean O{sub 2} concentration is higher and the gas temperature and mean CO concentration are lower in the side wall region. For centrally fuel rich swirl coal combustion burners in the bottom row, the combustion efficiency of the boiler increases from 96.73% to 97.09%, and NOx emission decreases from 411.5 to 355 ppm at 6% O{sub 2} compared to enhanced ignition-dual register burners and the boiler operates stably at 110 MWe without auxiliary fuel oil.

01 COAL, LIGNITE, AND PEAT↗

Coal-fired power generation: Proven technologies and pollution control systems

During the last two decades, significant advances have been made in the reduction of emissions from coal-fired power generating plants. New technologies include better understanding of the fundamentals of the formation and destruction of criteria pollutants in combustion processes (low nitrogen oxides burners) and improved methods for separating criteria pollutants from stack gases (FGD technology), as well as efficiency improvements in power plants (clean coal technologies). Future demand for more environmentally benign electric power, however, will lead to even more stringent controls of pollutants (sulphur dioxide and nitrogen oxides) and greenhouse gases such as carbon dioxide.

20 FOSSIL-FUELED POWER PLANTS↗

Economic Losses From a Fire in a Dense-Packed U.S. Spent Fuel Pool

In 2013, the staff of the U.S. Nuclear Regulatory Commission estimated the reduction of the off-site economic losses from a fire in a drained U.S. spent fuel pool if fuel that had cooled for more than five years were transferred to dry cask storage—an option it called “expedited transfer.” In this article, it is shown that the savings would be much higher than the NRC estimated. Savings increase to about $2 trillion if: losses beyond 50 miles are included; the land-contamination threshold for long-term population relocation is changed to that used for the Chernobyl and Fukushima accidents and recommended by the U.S. Environmental Protection Agency; and, based on the experience of Japan, decontamination of land areas to levels acceptable for population return is assumed to take at least four years. If expedited transfer were implemented, the off-site economic losses would be reduced by about 98%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical simulation of low NOx combustion technology in a 100 MWe bituminous coal-fired wall boiler

Computational fluid dynamics (CFD) has been applied to evaluate two NOx reducing schemes in a 100 MWe per hour (p/h) boiler that uses double volute burners without over-fire-air (OFA). The new schemes involve: a) changing the double volute burners for centrally fuel rich (CFR) burners, and b) using the OFA system in conjunction with a). In analyzing the results of these two schemes, various conclusions were drawn: 1) gas temperatures and related rise rates in the central zone of burners were higher, O{sub 2} and NOx concentrations were lower; and 2) cross-sectional gas temperature distributions through the burner centers in scheme employing b) is higher than that of original furnace set-up, and lower than that of scheme employing a). Comparing the b) scheme with those of the a) scheme and the original set-up, which is 277 mg/m{sup 3} (at 6% O{sub 2}) at the furnace outlet, the peak value of NOx concentration has decreased 571 mg/m{sup 3} (67.4%) and 436 mg/m{sup 3} (61.2%), respectively.

01 COAL, LIGNITE, AND PEAT↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 3: Optical properties of black and brown carbon emissions

Residential biomass combustion is a source of carbonaceous aerosol. Inefficient combustion, particularly of solid fuels produces large quantities of black and brown carbon (BC and BrC). These particle types are important as they have noted effects on climate forcing and human health. One method of measuring these quantities is by measurement of aerosol light-absorption and scattering, which can be performed using an aethalometer and nephelometer, respectively. These instruments are widely deployed in the study of ambient air and are frequently used in air quality modeling and source apportionment studies. In this study, we will describe (1) a method for measuring primary BC and BrC emissions from two residential log-fired wood hydronic heaters and (2) the BC and BrC emission from these devices over a wide range of operating conditions, such as cold-starts, warm-starts, four different levels of output ranging from 15% to 100% maximum rated output, and periods of repeated cycling. The range in flue-gas BC concentrations, measured using an aethalometer at the 880 nanometer (nm) wavelength, were between 5.09 × 10 2 and 2.24 × 10 4 micrograms per cubic meter (µg/m 3 ) while the scattering coefficient of the flue-gas, measured by a nephelometer at 880 nm, ranged between 2.20 × 10 3 and 8.56 × 10 5 inverse megameters (Mm –1 ). The BrC concentrations, measured using the 370 nm wavelength of an aethalometer, were between 9.10 × 10 1 and 3.56 × 10 4 µg/m 3 . The calculated Angstrom Absorption Exponent (AAE) of the flue-gas aerosol ranged between 1.54 and 3.63. Performing a comparison between the measured BC concentration and an external particulate matter (PM) concentration showed that overall BC makes up roughly a quarter of the PM emitted by either of the two appliances. Further for both appliances, the cold-start and the test phase immediately following it had the highest BC and BrC concentrations, the highest measured scattering coefficient, as well as a low AAE.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transformations and affinities for sulfur of Chinese Shenmu coal ash in a pulverized coal-fired boiler

The self-desulfurization efficiency of Shenmu coal with a high initial Ca/S molar ratio of 2.02 was measured in a 1,025 t/h pulverized coal-fired boiler. It increases from 29% to 32% when the power capacity decreases from 100% to 70%. About 60% of the mineral matter and calcium element fed into the furnace is retained in the fly ash, while less than 10% is retained in the bottom ash. About 70% of the sulfur element fed into the furnace is emitted as SO{sub 2} in the flue gas, while less than 10% is retained in the fly ash and less than 1% is retained in the bottom ash. The mineralogical compositions of feed coal, fly ash, and bottom ash were obtained by X-ray diffraction analysis. It is found that the initial amorphous phase content is 91.17% and the initial CaCO{sub 3} phase content is 2.07% in Shenmu coal. The vitreous phase and sulfation product CaSO{sub 4} contents are, respectively, 70.47% and 3.36% in the fly ash obtained at full capacity, while the retained CaCO{sub 3} and CaO contents are, respectively, 4.73% and 2.15%. However, the vitreous phase content is only 25.68% and no CaSO{sub 4} is detected in the bottom ash obtained at full capacity. When the power capacity decreases from 100% to 70%, the vitreous phase content in fly ash decreases from 70.47% to 67.41% and that in bottom ash increases from 25.68% to 28.10%.

01 COAL, LIGNITE, AND PEAT↗

Gas kinematics, morphology and angular momentum in the FIRE simulations

We report on the z = 0 gas kinematics, morphology and angular momentum content of isolated galaxies in a suite of cosmological zoom-in simulations from the FIRE project spanning Mstar = 10 6–11 M ⊙ . Gas becomes increasingly rotationally supported with increasing galaxy mass. In the lowest mass galaxies (M star < 10 8 M ⊙ ), gas fails to form a morphological disc and is primarily dispersion and pressure supported. At intermediate masses (Mstar = 10 8–10 M ⊙ ), galaxies display a wide range of gas kinematics and morphologies, from thin, rotating discs to irregular spheroids with negligible net rotation. All the high-mass (M star = 10 10–11 M ⊙ ) galaxies form rotationally supported gas discs. Many of the haloes whose galaxies fail to form discs harbour high angular momentum gas in their circumgalactic medium. The ratio of the specific angular momentum of gas in the central galaxy to that of the dark matter halo increases significantly with galaxy mass, from $\langle$jgas$\rangle$$\langle$jDM$\rangle$ ~ 0.1 at M star =10 6--7 M⊙ to$\langle$gas$\rangle$/$\langle$jDM$\rangle$ ~ 2 at M star = 1010–11 M ⊙ . The reduced rotational support in the lowest mass galaxies owes to (a) stellar feedback and the UV background suppressing the accretion of high angular momentum gas at late times, and (b) stellar feedback driving large non-circular gas motions. We broadly repeat the observed scaling relations between galaxy mass, gas rotation velocity, size and angular momentum, but may somewhat underpredict the incidence of disky, high angular momentum galaxies at the lowest observed masses (Mstar = (10 6 -2× 10 7 ) M ⊙ ). Stars form preferentially from low angular momentum gas near the galactic centre and are less rotationally supported than gas. The common assumption that stars follow the same rotation curve as gas thus substantially overestimates the simulated galaxies’ stellar angular momentum, particularly at low masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Formation of globular cluster candidates in merging proto-galaxies at high redshift: a view from the FIRE cosmological simulations

Using a state-of-the-art cosmological simulation of merging proto-galaxies at high redshift from the FIRE project, with explicit treatments of star formation and stellar feedback in the interstellar medium, we investigate the formation of star clusters and examine one of the formation hypotheses of present-day metal-poor globular clusters. Here, we find that frequent mergers in high-redshift proto-galaxies could provide a fertile environment to produce long-lasting bound star clusters. The violent merger event disturbs the gravitational potential and pushes a large gas mass of ≳ 10 5–6 M ⊙ collectively to high density, at which point it rapidly turns into stars before stellar feedback can stop star formation. The high dynamic range of the reported simulation is critical in realizing such dense star-forming clouds with a small dynamical time-scale, tff ≲ 3 Myr, shorter than most stellar feedback time-scales. Our simulation then allows us to trace how clusters could become virialized and tightly bound to survive for up to ~420 Myr till the end of the simulation. Finally, because the cluster's tightly bound core was formed in one short burst, and the nearby older stars originally grouped with the cluster tend to be preferentially removed, at the end of the simulation the cluster has a small age spread.

79 ASTRONOMY AND ASTROPHYSICS↗

Half-ice, half-fire-driven ultranarrow phase crossover in one-dimensional decorated 𝑞-state Potts ferrimagnets: An AI-co-led exploration

OpenAI’s reasoning model o3-mini-high was used to carry out an exact analytic study of one-dimensional ferrimagnetic site- and bond-decorated 𝑞-state Potts models. We demonstrate that the finite-temperature ultranarrow phase crossover (UNPC), driven by a hidden “half-ice, half-fire” state recently discovered in the 𝑞=2 case (Ising model), persists for 𝑞>2. Moreover, we identify unique features for 𝑞>2, including the dome structure in the field-temperature phase diagram, and for large 𝑞 a secondary high-temperature UNPC to the fully disordered paramagnetic state. As the UNPC quickly approaches a genuine transition by enhancing 𝐽, the interaction between the backbone spins, two distinct behaviors emerge: In the site-decorated Potts model, 𝑇 0 is independent of 𝐽 and thus remains unchanged (Type-I UNPC), and in the bond-decorated Potts model with 𝑞>2, 𝑇 0 depends on 𝐽 and quickly shifts toward a finite temperature as 𝐽 increases (Type-II UNPC). These results establish a versatile framework for engineering controlled fast state-flipping switches in low-dimensional systems. Our nine-dan artificial intelligence (AI)-contribution framework assigns AI the meritorious status of AI-co-led discovery in this work.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fokker-Planck description of conductance-based integrate-and-fire neuronal networks

Steady dynamics of coupled conductance-based integrate-and-fire neuronal networks in the limit of small fluctuations is studied via the equilibrium states of a Fokker-Planck equation. An asymptotic approximation for the membrane-potential probability density function is derived and the corresponding gain curves are found. Validity conditions are discussed for the Fokker-Planck description and verified via direct numerical simulations.

97 MATHEMATICS AND COMPUTING↗

High-Quality Cross-Sectioning Method: Examples of Applications in Optimizing Solar Cell Contact Firing

A damage-free polishing method is developed to prepare a high-quality cross-section of a large length of a solar cell. A 1-inch-long sample is diced from the solar cell and embedded in wax using a specially designed chuck. The sample edge is sequentially polished by progressively reducing the grit sizes. The final polishing is done by Chemical Mechanical Polishing (CMP). This polishing procedure produces a highly flat edge, with excellent interfaces between metal contacts and the Si cell. The planarity of the wafer edge makes it possible to perform a variety of analyses of various regions and the interfaces of the cell, using optical microscopy, EDX, scanning electron microscopy (SEM), and conductive AFM (C-AFM). Here, we will discuss some details of the chuck and the polishing procedure, and present some applications for optimizing the contact firing process. This method has an added advantage of delineating the back surface field for optical observation.

14 SOLAR ENERGY↗

Full operating range robust hybrid control of a coal-fired boiler/turbine unit - article no. 041011

Multi-input-multi-output robust controllers recently designed for the megawatt output/throttle pressure control in a coal-fired power plant boiler/turbine unit have demonstrated performance robustness noticeably superior to that of the currently employed nonlinear PID-based controller. These controllers, however, have been designed only for the range of 150-185 MW around the 185 MW nominal operating point, exhibiting a significant loss of performance in the lower range of 120-150 MW. Through system identification, the reason for this performance loss is demonstrated in the current work to be a pronounced dependence of the boiler/turbine unit steady state gains on the operating point. This problem is addressed via a hybrid control law consisting of two robust controllers and a robust switch between them activated by the set point change. The controllers are designed to cover the corresponding half-ranges of the full operating range. This permits attainment of the desired overall performance as well as reduction of modeling uncertainty induced by the operating point change to approximately 25% of that associated with the previous designs. Robust switching is accomplished through a novel hybrid mode of behavior-robustly controlled discrete transition.

20 FOSSIL-FUELED POWER PLANTS↗

Capacity mapping for optimum utilization of pulverizers for coal fired boilers - article no. 032201

Capacity mapping is a process of comparison of standard inputs with actual fired inputs to assess the available standard output capacity of a pulverizer. The base capacity is a function of grindability; fineness requirement may vary depending on the volatile matter (VM) content of the coal and the input coal size. The quantity and the inlet will change depending on the quality of raw coal and output requirement. It should be sufficient to dry pulverized coal (PC). Drying capacity is also limited by utmost PA fan power to supply air. The PA temperature is limited by air preheater (APH) inlet flue gas temperature; an increase in this will result in efficiency loss of the boiler. The higher PA inlet temperature can be attained through the economizer gas bypass, the steam coiled APH, and the partial flue gas recirculation. The PS/coal ratioincreases with a decrease in grindability or pulverizer output and decreases with a decrease in VM. The flammability of mixture has to be monitored on explosion limit. Through calibration, the PA flow and efficiency of conveyance can be verified. The velocities of coal/air mixture to prevent fallout or to avoid erosion in the coal carrier pipe are dependent on the PC particle size distribution. Metal loss of grinding elements inversely depends on the YGP index of coal. Variations of dynamic loading and wearing of grinding elements affect the available milling capacity and percentage rejects. Therefore, capacity mapping in necessary to ensure the available pulverizer capacity to avoid overcapacity or undercapacity running of the pulverizing system, optimizing auxiliary power consumption. This will provide a guideline on the distribution of raw coal feeding in different pulverizers of a boiler to maximize system efficiency and control, resulting in a more cost effective heat rate.

01 COAL, LIGNITE, AND PEAT↗

Numerical Model of Thermoelectric Topping Cycle of Coal-Fired Power Plant

Traditional fossil fuel power generation process typically has low efficiency. Large amount of the energy loss in Rankine cycle steam turbines (ST) is due to the temperature difference between the combustion flame temperature ~2250 K (adiabatic) and the high pressure steam temperature up to 900 K. However, some of this energy can be harvested using solid-state thermoelectric (TE) power generators which are placed into the gap between the flame temperature and the steam temperature that produce additional electrical power. This study investigates the potential placement of TE on water tube wall inside a boiler at a coal-fired power plant. Three-dimensional (3D) numerical model of a simplified TE module is developed, and hot gas temperature and steam temperature from the boiler are used as boundary conditions at the hot side and cold side of the TE. The numerical results are compared with analytical calculations. The 3D effects of the thermal spreading in the TE module are investigated. Parameters such as TE leg cross section area and TE fill factor are examined in order to maximize the electrical power production of the TE without sacrificing the boiler efficiency (i.e., reducing the steam temperature). The study also looks into the various locations inside the boiler that have good potential for TE installation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗