Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FINS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Kilovolt Tri-Gate GaN Junction HEMTs with High Thermal Stability

The lack of reports on the high-temperature performance of tri-gate GaN power HEMTs has raised serious concern on their competitiveness. This work demonstrates the first normally-off tri-gate GaN HEMT that can block kilovolts at 150 °C and zero gate bias. The key enabling device design is a new type of tri-gate, the junction tri-gate, which comprises p-n junction wrapping around AlGaN/GaN fins in the gate region. At 150 °C, the GaN tri-gate junction HEMT (Tri-JHEMT) retains strong gate control and stable threshold voltage, while the traditional tri-gate metal-insulator-semiconductor (MIS) HEMTs fabricated on the same wafer shows a large threshold voltage shift and inferior capabilities of voltage blocking. These results show the excellent thermal stability of GaN Tri-JHEMTs and their great potentials for power electronics applications.

Ma, Yunwei↗

Microwatt fuel cell stack

A microwatt fuel cell stack that demonstrates a wide range temperature tolerance, low reactant cross-over and leakage, low internal leakage current, and/or effective water transport is disclosed. Both H 2 and O 2 may be supplied directly to the fuel cell stack (i.e., dead-ended). One-piece gas diffusion electrodes (GDEs) may serve as both the active electrode and manifold port. Water removal may be accomplished by permeation through the membrane to “fins” exposed by notches in the bipolar plates and gaskets.

Wilson, Mahlon Scott↗

Intrinsic Junction Thermocouples For Surface Temperature Measurement

The material selection, attachment, and calibration of intrinsic junction thermocouples is discussed. Intrinsic junction thermocouples are utilized for their fast response times in surface measurements during high thermal transients. The as-is measurement and calibrated corrections are presented for both the out-of-pile pulse power system and the critical heat flux experiments in the Idaho National Laboratory Transient Reactor Test facility. The fin effect from temperature measurements on the surface of fuel cladding is corrected using a linear coefficient, m, and temperature corrections are sometimes 100 °C or more—representing 18% of the original temperature measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reactor fuel pellets with thermally-conductive inserts, and related reactor fuel pellet arrangements

Fuel pellets and fuel pellet arrangements include thermally-conductive inserts within a fuel. The inserts have at least one portion of a thermally-conductive material, such as radially-extending fins. The inserts are configured to dissipate heat during use of the fuel pellets, while minimizing the amount of the total volume of the fuel pellet that is occupied by non-fissile material. The inclusion of heat-dissipating inserts enables the fuel pellets to exhibit improved thermal performance over the lifetime of the fuel, including a relatively low peak temperature and relatively low integrated average temperatures, while the minimal volume of the inserts avoids significantly decreasing the percent of enrichment achievable.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of Numerical Model of Metal Foam with PCM for the Estimation of Effective Thermal Conductivity

Global warming due to climate change is a threat to humankind. Nuclear energy is one of the promising solutions to reduce fossil fuel usage. Nuclear energy can handle the base load, compensating for the volatility of renewable energy. If nuclear energy could achieve load following capability, the combination with renewable energy would be more suitable. Thermal energy storage (TES) is one of the options for enabling load following of nuclear reactors. The TES makes it possible to store surplus nuclear thermal energy and release it later as needed. In Idaho National Laboratory (INL), a new concept of latent heat TES integrated with high-temperature heat pipe has been proposed and is under development, which is called Heat pipe-Integrated Thermal Battery (HITB). HITB exchanges thermal energy between the reactor system and TES via heat pipe. The heat transferred to TES medium, made of phase change material (PCM), stores energy as sensible heat and/or latent heat. As PCM typically has poor thermal conductivity, however, various heat transfer enhancement techniques are required to achieve a rapid charging cycle. There are many techniques to enhance the heat transfer ability of TES medium such as disk, fin, and metal foam. Among them, metal foam is an appropriate option to enhance the heat transfer because it maximizes the heat transfer area through metal wicks. Metal foam is a lightweight metal structure that has a high porosity of over 0.9. The typical materials for metal foam are Aluminum, Copper, Nickel, and Silicon Carbide (SiC). Metal foam not only enhances heat transfer via conduction but also increases contact surface area. In the HITB design , the metal foam is being considered as one of the options to enhance the heat transfer of TES medium (PCM) [1]. To predict the enhanced thermal performance of TES, one should properly estimate the effective thermal conductivity of metal foam combined with PCM material or calculate heat transfer in distributed model. There are many experimental works that provides effective thermal conductivity of metal foam with various PCM [2,3]. Also, many theoretical models were developed based on the unit cell model of metal foam [4,5]. With a distributed model, on the other hand, detail heat transfer characteristics between metal foam and PCM material can be analyzed considering the geometry or buoyancy effect. However, due to the complex geometry of metal foam pores, the computational cost for three-dimensional modeling highly increases. Therefore, if metal foam structure can be modeled in simple and repetitive design, the computational cost would decrease Among the various metal foam models [2], lattice model is one of the simple and extendable design. The porosity and pores per inch (PPI) can be characterized by the size and spatial distance of lattice structure. If the three-dimensional metal foam model consists of lattice structure could properly estimate the heat transfer, which is characterized by effective thermal conductivity, it would be a good option to assess the thermal performance of metal foam with PCM. In this study, a three-dimensional numerical model was developed to simulate conductive heat transfer between metal foam and PCM. The three-dimensional lattice structure of square pillars was selected as a basic structure of the metal foam. The calculation result was characterized by the effective thermal conductivity of the whole domain. A sensitivity study was conducted for mesh size, domain size, and PPI to check whether the calculation result gives a converged result or not. Lastly, the effective thermal conductivity from the lattice model was compared with existing experimental data to validate the model result

25 ENERGY STORAGE↗

GaN vertical-channel junction field-effect transistors with regrown p-GaN by metal organic chemical vapor deposition (MOCVD)

Fabricating a vertical-channel junction field-effect transistor includes forming an unintentionally doped GaN layer on a bulk GaN layer by metalorganic chemical vapor deposition, forming a Cr/SiO 2 hard mask on the unintentionally doped GaN layer, patterning a fin by electron beam lithography, defining the Cr and SiO 2 hard masks by reactive ion etching, improving a regrowth surface with inductively coupled plasma etching, removing hard mask residuals, regrowing a p-GaN layer, selectively etching the p-GaN layer, forming gate electrodes by electron beam evaporation, and forming source and drain electrodes by electron beam evaporation. The resulting vertical-channel junction field-effect transistor includes a doped GaN layer, an unintentionally doped GaN layer on the doped GaN layer, and a p-GaN regrowth layer on the unintentionally doped GaN layer. Portions of the p-GaN regrowth layer are separated by a vertical channel of the unintentionally doped GaN layer.

Zhao, Yuji↗

Heat Exchangers Circuitry Optimization using Low-GWP Refrigerants in Reversible Heat Pump Applications

Tube-fin heat exchangers (TFHX) are widely used in heat pump applications. Circuitry optimization can improve system performance. Previous optimizations focus on improving component-level performance under a specific operating condition, i.e., the TFHX either works as a condenser or an evaporator. The optimal circuitry obtained under air conditioning (AC) mode cannot guarantee optimal performance when used in heat pump (HP) mode. This study implements a bi-objective formulation to achieve optimal system performance in both AC and HP modes. An integer permutation-based Genetic Algorithm is integrated with Heat Pump Design Model (HPDM) to perform heat pump optimization. Six refrigerants, i.e., R410A, R452B, R454B, R32, D2Y60 and L41a are investigated. Case studies show that optimal heat exchangers yield 2.1%-6.1% EER improvement under AC mode and 1.9%-8.5% COP improvement under HP mode. Use of this design approach can help assure a preferable performance of reversible heat pumps during both cooling and heating mode usage.

Li, Zhenning↗

Preliminary studies on the heat exchanger option for S-CO{sub 2} power conversion cycle coupled to water cooled SMR

For more than a half century, the steam Rankine cycle had been the major power conversion cycle for a nuclear power plant. However, as the interest on the next generation reactors grows, a variety of alternative power conversion systems have been studied. Among them, the S-CO{sub 2} cycle (Supercritical carbon dioxide Brayton cycle) is considered as a promising candidate due to several benefits such as 1) Relatively high thermal efficiency at relatively low turbine inlet temperature, 2) High efficiency with simple lay-out 3) Compactness of turbo-machineries. 4) Compactness of total cycle combined with PCHE (Printed Circuit Heat Exchanger). According to the conventional classification of heat exchangers (HE), there are three kind of HE, 1) Tubular HEs, 2) Plate-type HEs, 3) Extended surface HEs. So far, the researcher has mostly assumed PCHE type HE for the S-CO{sub 2} cycle due to its compactness with reasonably low pressure drop. However, PCHE is currently one of the most expensive components in the cycle, which can have a negative effect on the economics of the cycle. Therefore, an alternative for the HE should be seriously investigated. By comparing the operating condition (pressure and temperature) there are three kind of HE in the S-CO{sub 2} cycle, 1) IHX (Intermediate Heat exchanger) 2) Recuperator and 3) Pre-cooler. In each heat exchanger, hot side and cold side coolants are different, i.e. reactor coolant to S-CO{sub 2} (IHX), S-CO{sub 2} to S-CO{sub 2}(Recuperator), S-CO{sub 2} to water (Pre-cooler). By considering all the attributes mentioned above, all existing types of heat exchangers are compared to find a possible alternative to PCHE. The comparing factors are 1) Size(volume), 2) Cost. Plate fin type HEs are considered to be the most competitive heat exchanger regarding the size and the cost after some improvements on the design limit are made. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Composite luminaire

A luminaire includes a core made up of a first material and an LED lighting arrangement mounted to the core. The luminaire further includes a housing made up of a second material. The second material is different from the first material. The housing including a recess in which the core is received. The housing further includes a finned part.

Santiago Baerga, Jeremy M.↗

Wireless in-core acoustic telemetry and self-powered sensing

A promising wireless telemetry infrastructure based on acoustic transmission of in-pile measurements (information) is being developed at the Idaho National Laboratory for use in nuclear reactors. In this paper, we will demonstrate an approach to telemetry and sensing that exploits a reactor core's energy-rich environment to generate acoustic telemetry signals from self-powered telemeters that produce sounds. These sounds propagate through the reactor's coolant, whether it is gas, water, or liquid metal, through its mechanical structures (e.g., lattice work, pressure vessel, and piping), and can be detected outside the reactor. A thermo-acoustic (TAC) sensor was designed to be geometrically indistinguishable from the other Training Research Isotopes General Atomics (TRIGA) fuel elements in the Breazeale reactor's core. Heat was produced by fission of two Pathfinder {sup 235}UO{sub 2} fuel pellets contained within a finned heat exchanger. The acoustic signals from the TAC sensor can be picked up by hydro-phones and accelerometers anywhere in the reactor pool and from structures that penetrate the pool. Most of the signals we acquired had sufficient signal-to-noise ratios even with both the {sup 16}N diffusion pump and the pool coolant pump operating. The TAC sensor was tested during eight irradiation runs in the Breazeale Nuclear Reactor over the span of a week. We were able to show that the frequency of the thermo-acoustically generated sound provides an accurate determination of the reactor's coolant temperature. Such a sensor strategy might have provided useful information in a reactor accident like that which destroyed the Fukushima complex in March 2011.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

MP197HB; First licensed transportation package with canistered high burnup fuel after dry storage - 15580

AREVA TN has recently received the NRC 10 CFR Part 71 transportation license CoC 9302 Revision 7 for the MP197HB transportation package that allows transportation of canistered high burnup fuel assemblies. The Nuclear Horizontal Modular Storage (NUHOMS{sup R}) system canisters containing high burnup PWR and BWR fuel assemblies are now licensed for transportation as a payload in MP197HB after these canisters were in dry storage at the utility ISFSIs. Enhancements have been made to the MP197HB transportation package to improve thermal performance and also provide superior shielding capabilities. Design features of existing AREVA TN transportation packages such as radial fins, thermal shield, neutron resin and optimized gamma and neutron shielding were used to accommodate transportation of high burnup fuel assemblies with heat loads up to 32 kW. The transportation package is designed for exclusive use by rail, truck or marine transport. State-of-the-art analyses methodologies were used to demonstrate compliance with regulatory requirements of 10 CFR 71.55 for the high burnup fuel after dry storage at any ISFSI. Some of the issues addressed in the license application related to the transportation of high burnup fuel included potential degradation of fuel cladding, uncertainty associated with high burnup fuel cladding material properties, and larger radiation and thermal sources due to higher burnups. Bounding conservative assumptions were made where limited test data was available. AREVA TN's licensing approach did not rely on the cladding integrity of high burnup fuel cladding. Instead, the criticality, thermal and shielding analyses were carried out assuming high burnup fuel reconfiguration. With the approval of this transportation package for PWR and BWR canistered high burnup fuel from dry storage at ISFSIs, the utilities can now transport these canisters which are in dry storage at their sites. This is also a major step forward for the canistered fuel that is currently in dry storage at the shutdown plants because they can use this AREVA TN MP197HB transportation package to ship that fuel to any interim storage facility (ISF) or to a repository when they become available. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multi-objective optimization of a PCHE-type intermediate heat exchanger using genetic algorithms

For the advanced nuclear reactor systems and power conversion units, it is important to optimize the design of intermediate heat exchangers (IHXs) which transfer heat from the primary loop to the secondary or intermediate loop. For a multi-objective optimization problem, a printed circuit heat exchanger-type IHX with zigzag and S-shaped fin channels is selected to be optimized in terms of both the total cost and the heat exchanger thermal effectiveness using genetic algorithms. A computer code is developed to search a set of optimized designs of the zigzag channel geometry. It is found that among the Pareto-optimal solutions, the total cost is approximately linearly related to the thermal effectiveness between 88 and 95% while it rises rapidly after the effectiveness exceeds 95%. An optimal flow channel diameter is also determined through the optimization. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Treatment of Foreign Radioactive Waste at the BELGOPROCESS Plant - 19345

Belgium has used a large number of nuclear technologies during the last 60 years. Power generation, reprocessing, fuel fabrication, isotope production and research activities have produced a large variety of radioactive waste streams. BELGOPROCESS is the operator of the centralised waste treatment facilities located in the Campine region in Flanders. Over the years BELGOPROCESS has developed the know-how and facilities to treat each one of these waste streams. BELGOPROCESS is a subsidiary of NIRAS, the governmental institution responsible for the safe management of radioactive waste and enriched fissile materials in Belgium. A number of these waste streams are only produced during a short period of time. After processing the existing stockpile the treatment facility is put into operational standby and eventually prepared for decommissioning. In order to treat the stockpile of some types of legacy waste within an acceptable time frame, the treatment facilities needed to be designed at a certain treatment capacity. Since the majority of the legacy waste is processed nowadays, a significant amount of treatment capacity becomes available. In June 2006 the Belgian government decided that this know-how and facilities should become available to foreign waste producers. This would allow BELGOPROCESS to fill up the available capacity of its facilities and consequently lower the cost for the Belgian waste producers. Nowadays two facilities are open to accept foreign radioactive waste. The CILVA-facility can be used for sorting, cutting, incineration, precompaction, supercompaction and cementation of low level solid waste. The PAMELA-facility - a former vitrification plant - can be used for the treatment of medium level and alpha-bearing waste. In this paper we will discuss the technical characteristics of the CILVA-incinerator and a showcase for the treatment of foreign waste at our facilities. In 2016 BELGOPROCESS started a cooperation with MATE-FIN for the incineration of low level burnable waste from the Cernavoda NPP in Romania. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparing Velocity Profiles Along the Rod Length of a Helical Coil Steam Generator Model

A model of a specific type of tube and shell heat exchanger, the helical coil steam generator (HCSG), was designed and constructed to study multiple fluidic properties that attribute to the efficiency of the heat transfer it provides. Tube and shell heat exchangers are currently used throughout industry in chemical, power and petroleum engineering. Most commonly, a primary flow is circulated through a shell, while the secondary flow is run through several small tubes that are bundled together. Methods to increase the heat transfer between the two flows include adding baffles to force shell side flow over more tubes, fins added in-between layers of tubes and passing tubes multiple times through the shell to increase heat exchanger effectiveness. The HCSG incorporates many of the proposed methods but also relies on a complex geometry to increase the heat transfer between tube and shell side flow. In an area where cost effectiveness is favorable, such as inside a nuclear reactor, helically banked steam generators makes extensive use of the room with no sharp tube bends. This increases the pressure loss on the secondary flow and can solve potential temperature manufacturing issues at the welds of junctions. Additionally, they have exhibited pure cross flow behaviors with high heat transfer coefficients and axial temperature profiles that correspond to pure counter-flow with high mean temperature differences. Early work showed that helical banks can have a significant increase of 16 to 43% higher heat transfer coefficient than straight pipe heat exchangers. While many previous studies have looked at the heat transfer, pressure drop and flow fields of a tube and shell heat exchanger, they all focus on tube bundles that are either in-line or staggered. The early flow visualization studies on these types of bundle arrangements reported that attached eddies were formed alternatively behind each of the rods and were occasionally dragged into the main stream of shell side flow. Later studies suggested that observable periodic vortex shedding was dependent on geometry. Experimental data taken using techniques such as laser Doppler anemometry (LDV) by Simonin and Barcouda (1986) as mentioned in Hassan (2002), hot-wire anemometry with Tsuchida (1982) and particle image velocimetry (PIV) conducted by researchers as late as 2007 have been used to characterize turbulent flow and distinguish flow field structures within in-line and staggered tube bundles. By studying these flow field structures, their contribution to fluidic properties such as heat transfer efficiency and pressure drop can be characterized effectively. Literature review lead to a design that incorporated five layers of coils wrapped around one another. The outermost and middle layers of tubes coiled at a specific pitch in a clockwise direction while the other two layers coiled counterclockwise. The proposed design incorporates a constantly changing lateral pitch ratio, a, between adjacent rods. The constructed test section isolates a single interface between two adjacent coiling rod bundles of twelve rods. Three distinct cross sectional planes along the rod bundles were looked at to study the effect of the local geometry to flow fields, Section A, B and C. Particle Image Velocimetry (PIV) frames of 896 x 848 pixels were captured at each section across a specific height. Profiles of mean velocity fields for each section are compared and discussed as possible features of the changing lateral pitch ratio.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Influence of Axial Power Distributions on Rod-to-wall Gap

In a scaled-down (3 x 3, 4 x 4, 5 x 5 or 6 x 6) rod bundle thermal hydraulic experiment, channel walls were often applied to surround the experimental rod bundle and provide a hydraulic flow boundary for the experiments. However, in the actual PWR (Pressurized Water Reactor), there are no walls surrounding the rod bundle fuel assembly. These non-representative walls can lead to non-prototypical conditions in the rod bundle experiments. There are several researches about the wall effects in rod bundle experiments. Based on hydraulic consideration, Zang developed a wall effect factor by subchannel analysis method to investigate the wall effects of different scale rod bundles. He did not pay attention to the wall effects in thermal aspects. Li studied the wall effects of different scale rod bundles of tight arrangement spiral-fin fuel assembly by CFD. The existing researches mostly focus on the wall effects of different scale rod bundles. There are very few, if any at all, studies focus on how to avoid or minimize wall effects through proper experimental design by adjusting the rod-to-wall gap (the gap between the channel wall and outer rod wall) for rod bundles of various scales. In addition, the axial power distribution is different in different periods of the life cycle in the PWR core. For example, it usually is outlet peak power distribution in the axial direction at the beginning of life span. However, it may turn to the inlet peak power distribution when the control rods are pulled out from the high burn up of fuel in the reactor core. Both flow dynamics and heat transfer mechanism change depending on various axial power distributions. Subsequently, it is important to study the impacts of the wall effects on flow and heat transfer with different axial power distributions in rod bundle experiments. That is, in the evaluation of rod-to-wall gap in rod bundle experiments, the influence of axial power distributions should be examined. In this paper, the rod-to-wall gap was calculated in axially uniform and non-uniform power, including inlet peak, cosine, and exit peak heat flux distributions. The rod-to-wall gap calculation results were then compared with respect to two different criterion: the average fluid temperature and the maximum wall temperature criterion, to study the influence of axial heat flux profile on radial thermal distribution.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Storage and concentration of plutonium and uranium solutions in LES 401 hot cell (ATALANTE) - criticality safety considerations - 14414

ATALANTE, located in Marcoule, is one of the main nuclear facilities of the French CEA (Atomic Energy and Alternative Energies Commission). The LES 401 hot cell was built in the 1980's and, since then, has been operating only with low masses of fissile material. As part of the management optimization for purified Uranium and Plutonium solutions ('Fin U Pu' Project), the new functions provided in LES 401 are now expected to be the following: - Reception of Uranium and Plutonium solutions, - Concentration of these solutions, - Storage of the concentrates and distillates. From the criticality safety point of view, the equipment was originally designed in safe geometry for Plutonium Nitrate, considering only a 2.5 cm -thick water reflector. However, the new criticality safety case had to take into account the following points: - Reception of not only Plutonium solutions, but also highly enriched Uranium solutions, - Considering flood risk as a possible contingency, - Considering precipitation as a possible contingency. These more conservative assumptions have meant introducing a mass limit for the cell, in addition to the geometry control mode. For the equipment containing very low concentrations of fissile material in normal operation, it was necessary, using the double contingency principle, to take a concentration limit into account in the specific situation of water flooding the cell. Finally, given the mass and geometry control mode, it was necessary to perform all the calculations with both fissile media (Plutonium and Uranium), as it was found that depending on the selected mass, geometry, and reflection conditions, the most penalizing media is not always the same. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental Investigation on Cooling performance of A Thermoelectric Freezer

Thermoelectric heat pumps (TEHPs) have found widespread use in the electronics cooling industry and portable refrigerators. However, there has been a lack of extensive research on the application of TEHPs in low-temperature refrigeration settings. To address this gap, various configurations of TEHPs were fabricated to assess their suitability for freezer applications. Key parameters such as cooling capacity and system performance of the TEHPs were crucial in evaluating these configurations. Three configurations, each with different numbers of cooling units and fan arrangements, were tested using a 300-liter freezer prototype under typical room conditions (21°C). A cooling unit is comprised of two-stage thermoelectric modules, an aluminum plate fin heat exchanger sink with fans positioned either on top or directing airflow through the center, and a cooling block with circulating icy water for heat dissipation. Across all configurations, the minimum temperature inside the freezer cabinet reached -16.0°C. The cooling capacity peaked at 74.7 W, with the thermoelectric coefficient of performance (COP) reaching a maximum of 0.45. System COP ranged from 0.23 to 0.28. Minimum TE power consumption was recorded at 138.8 W, with TE system power consumption at 174.4 W, indicating feasibility for practical residential freezer applications. This investigation lays the foundation for integrating TE freezers with ice thermal storage systems.

Hu, Yifeng↗

Numerical study of advanced solar receiver tubes based on a coupled thermo-mechanical analysis for concentrated solar power tower plant

The search for more sustainable energy to match the growing energy demand begins with finding more dispatchable resources such as solar energy. As one of the promising solar technologies, concentrated solar power (CSP) has a full capacity to store thermal energy for extended operation. Nevertheless, some key components in CSP systems usually face extreme environment, such as uneven solar flux, cyclic thermal expansion, structural degradation on the solar absorber tubes in a Concentrated Solar Power Tower (CSPT) Plant. In this study, we applied Multiphysics simulation to explore the benefits of introducing optimized fins for heat transfer enhancement and uniform temperature distribution, the goal is to improve the thermal efficiency of such advanced solar absorber tubes. The results of this study can supply design guidance for the manufacturing process of absorber tubes, and eventually can benefit the solar energy community for the next generation of molten salt based CSP system.

14 SOLAR ENERGY↗