Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Error analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

A large-scale study of soft-errors on GPUs in the field

Parallelism provided by the GPU architecture has enabled domain scientists to simulate physical phenomena at a much faster rate and finer granularity than what was previously possible by CPU-based large-scale clusters. Architecture researchers have been investigating reliability characteristics of GPUs and innovating techniques to increase the reliability of these emerging computing devices. Such efforts are often guided by technology projections and simplistic scientific kernels, and performed using architectural simulators and modeling tools. Lack of large-scale field data impedes the effectiveness of such efforts. This study attempts to bridge this gap by presenting a large-scale field data analysis of GPU reliability. We characterize and quantify different kinds of soft-errors on the Titan supercomputer's GPU nodes. Our study uncovers several interesting and previously unknown insights about the characteristics and impact of soft-errors.

Nie, Bin↗

Accelerating Relative-error Bounded Lossy Compression for HPC datasets with Precomputation-Based Mechanisms

Scientific simulations in high-performance computing (HPC) environments are producing vast volume of data, which may cause a severe I/O bottleneck at runtime and a huge burden on storage space for post-analysis. Unlike the traditional data reduction schemes (such as deduplication or lossless compression), not only can error-controlled lossy compression significantly reduce the data size but it can also hold the promise to satisfy user demand on error control. Point-wise relative error bounds (i.e., compression errors depends on the data values) are widely used by many scientific applications in the lossy compression, since error control can adapt to the precision in the dataset automatically. Point-wise relative error bounded compression is complicated and time consuming. In this work, we develop efficient precomputation-based mechanisms in the SZ lossy compression framework. Our mechanisms can avoid costly logarithmic transformation and identify quantization factor values via a fast table lookup, greatly accelerating the relative-error bounded compression with excellent compression ratios. In addition, our mechanisms also help reduce traversing operations for Huffman decoding, and thus significantly accelerate the decompression process in SZ. Experiments with four well-known real-world scientific simulation datasets show that our solution can improve the compression rate by about 30% and decompression rate by about 70% in most of cases, making our designed lossy compression strategy the best choice in class in most cases.

compression rate↗

Automated Quantitative Analysis of Extended Irradiation Defects - Dislocations, Voids and Precipitates in Neutron Irradiated HT-9 Steel

Structural alloys that make up the core components of nuclear reactors are exposed to radiation that can substantially alter the microstructure and mechanical properties of the material. Irradiation can cause the formation of extended defects including dislocation line and loops, voids and various types of precipitates. To understand the irradiation effects, it is critical to characterize these defects individually and collectively to quantify how they evolve throughout irradiation stages. Transmission electron microscopy (TEM) is a standard tool for providing extensive size, number density and spatial distribution of extended irradiation defects, however, manual measurement of defect size and number density requires time-intensive effort to analyze enough defects that provide a statistically meaningful result and are prone to errors of subjectivity. In this work, we developed a set of MATLAB algorithms offering robust and automated identification and quantification of extended irradiation defects like dislocation lines, voids and precipitates commonly observed in neutron irradiated cladding alloys [1]. Using a neutron-irradiated HT-9 martensitic alloy irradiated at 412°C to 111.8 dpa, we demonstrate the capability of these algorithms for quantitative defect analysis. Figure 1 presents defect images of the HT-9 using an advanced diffraction contrast imaging scanning transmission electron microscopy (DCI STEM) that suppresses bend contours and provides better defect contrast compared to conventional TEM [2]. The first step of defect analysis is defect identification, a process that can be digitally achieved by contrast thresholding (for simple defect contrast) and by machine learning computer vision for defect semantic segmentation [3]. Here, labeled binary defect images (Figures 2a and 2c) were used. For dislocation density quantification, we employed an optimized circular-grid intersection method first introduced by Dr. John Steeds [4]. This method is shown in Figures 2a and 2b, where the number of intersections of dislocation lines with circular traces was measured. This produces an unbiased sampling of dislocation lines, regardless of their orientation. This process was optimized with automated digital intersection number and grid length registration. Interestingly, it was found that a relatively large number of circles in a set circular gird is was needed to produce an invariant result (Figure 2b), with a low systematic measurement error. This demonstrates the main advantage of computer-based defect analysis, in performing repetitive operations quickly with a reduced systematic error. For the quantitative analysis of voids and precipitates a challenge encountered with automated defect analysis is feature overlap, particularly when the density of voids/precipitates is high. To mitigate this problem, as shown in Figure 2d, we modified the popular circular Hough transformation and treated ‘circular shape’ as the particle descriptor for voids/precipitates, efficiently resolving the overlapping particles. In summary, this automated digital quantification together with machine learning enabled defect identification [3] opens new opportunities for standardizing the characterization workflow for quantitative analysis of extended irradiation defects.

Sainju, Rajat↗

Grover-like search via a Frenkel-exciton trapping mechanism

We propose the physical implementation of a Grover-like search problem by means of Frenkel exciton trapping at a shallow isotopic impurity against a background of competing mechanisms. The search, culminating at the impurity molecule, designated the 'winner' site, is marked by its enhanced interaction with acoustic phonons at low temperatures. The quantum search proceeds with the assistance of an oracle-like exciton-phonon interaction that addresses only the impurity site via the Dyson propagator within the Green's function formalism. The optimum parameters of a graph lattice with long-range intersite interactions required to trap the exciton in the fastest time are determined, and estimates of error rates for the naphthalene-doped organic system are evaluated. We extend the analysis of the quantum search to a fluctuating long-range interacting cycle (LRIC) graph-lattice system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-184: Clinical VMAT QA Practice Using LINAC Delivery Log Files

Purpose: To evaluate the accuracy of volumetric modulated arc therapy (VMAT) treatment delivery dose clouds by comparing linac log data to doses measured using an ionization chamber and film. Methods: A commercial IMRT quality assurance (QA) process utilizing a DICOM-RT framework was tested for clinical practice using 30 prostate and 30 head and neck VMAT plans. Delivered 3D VMAT dose distributions were independently checked using a PinPoint ionization chamber and radiographic film in a solid water phantom. DICOM RT coordinates were used to extract the corresponding point and planar doses from 3D log file dose distributions. Point doses were evaluated by computing the percent error between log file and chamber measured values. A planar dose evaluation was performed for each plan using a 2D gamma analysis with 3% global dose difference and 3 mm isodose point distance criteria. The same analysis was performed to compare treatment planning system (TPS) doses to measured values to establish a baseline assessment of agreement. Results: The mean percent error between log file and ionization chamber dose was 1.0%±2.1% for prostate VMAT plans and −0.2%±1.4% for head and neck plans. The corresponding TPS calculated and measured ionization chamber values agree within 1.7%±1.6%. The average 2D gamma passing rates for the log file comparison to film are 98.8%±1.0% and 96.2%±4.2% for the prostate and head and neck plans, respectively. The corresponding passing rates for the TPS comparison to film are 99.4%±0.5% and 93.9%±5.1%. Overall, the point dose and film data indicate that log file determined doses are in excellent agreement with measured values. Conclusion: Clinical VMAT QA practice using LINAC treatment log files is a fast and reliable method for patient-specific plan evaluation.

60 APPLIED LIFE SCIENCES↗

Adaptive multi-index collocation for uncertainty quantification and sensitivity analysis

In this paper, we present an adaptive algorithm to construct response surface approximations of high-fidelity models using a hierarchy of lower fidelity models. Our algorithm is based on multiindex stochastic collocation and automatically balances physical discretization error and response surface error to construct an approximation of model outputs. This surrogate can be used for uncertainty quantification (UQ) and sensitivity analysis (SA) at a fraction of the cost of a purely high-fidelity approach. We demonstrate the effectiveness of our algorithm on a canonical test problem from the UQ literature and a complex multi-physics model that simulates the performance of an integrated nozzle for an unmanned aerospace vehicle. We find that when the input-output response is sufficiently smooth our algorithm produces approximations that can be up to orders of magnitude more accurate than single fidelity approximations for a fixed computational budget.

97 MATHEMATICS AND COMPUTING↗

SU-F-T-252: An Investigation of Gamma Knife Frame Definition Error When Using a Pre-Planning Workflow

Purpose: To determine causal factors related to high frame definition error when treating GK patients using a pre-planning workflow. Methods: 160 cases were retrospectively reviewed. All patients received treatment using a pre-planning workflow whereby stereotactic coordinates are determined from a CT scan acquired after framing using a fiducial box. The planning software automatically detects the fiducials and compares their location to expected values based on the rigid design of the fiducial system. Any difference is reported as mean and maximum frame definition error. The manufacturer recommends these values be less than 1.0 mm and 1.5 mm. In this study, frame definition error was analyzed in comparison with a variety of factors including which neurosurgeon/oncologist/physicist was involved with the procedure, number of post used during framing (3 or 4), type of lesion, and which CT scanner was utilized for acquisition. An analysis of variance (ANOVA) approach was used to statistically evaluate the data and determine causal factors related to instances of high frame definition error. Results: Two factors were identified as significant: number of post (p=0.0003) and CT scanner (p=0.0001). Further analysis showed that one of the four scanners was significantly different than the others. This diagnostic scanner was identified as an older model with localization lasers not tightly calibrated. The average value for maximum frame definition error using this scanner was 1.48 mm (4 posts) and 1.75 mm (3 posts). For the other scanners this value was 1.13 mm (4 posts) and 1.40 mm (3 posts). Conclusion: In utilizing a pre-planning workflow the choice of CT scanner matters. Any scanner utilized for GK should undergo routine QA at a level appropriate for radiation oncology. In terms of 3 vs 4 post, it is hypothesized that three posts provide less stability during CT acquisition. This will be tested in future work.

60 APPLIED LIFE SCIENCES↗

Using Host Galaxy Photometric Redshifts to Improve Cosmological Constraints with Type Ia Supernovae in the LSST Era

We perform a rigorous cosmology analysis on simulated Type Ia supernovae (SNe Ia) and evaluate the improvement from including photometric host galaxy redshifts compared to using only the "z spec " subset with spectroscopic redshifts from the host or SN. We use the Deep Drilling Fields (~50 deg 2 ) from the Photometric LSST Astronomical Time-Series Classification Challenge (PLAsTiCC) in combination with a low-z sample based on Data Challenge2. The analysis includes light-curve fitting to standardize the SN brightness, a high-statistics simulation to obtain a bias-corrected Hubble diagram, a statistical+systematics covariance matrix including calibration and photo-z uncertainties, and cosmology fitting with a prior from the cosmic microwave background. Compared to using the z spec subset, including events with SN+host photo-z results in (i) more precise distances for z > 0.5, (ii) a Hubble diagram that extends 0.3 further in redshift, and (iii) a 50% increase in the Dark Energy Task Force figure of merit (FoM) based on the w 0 w a CDM model. Analyzing 25 simulated data samples, the average bias on w 0 and w a is consistent with zero. The host photo-z systematic of 0.01 reduces FoM by only 2% because (i) most z < 0.5 events are in the z spec subset, (ii) the combined SN+host photo-z has ×2 smaller bias, and (iii) the anticorrelation between fitted redshift and color self-corrects distance errors. To prepare for analyzing real data, the next SN Ia cosmology analysis with photo-zs should include non–SN Ia contamination and host galaxy misassociations.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement and correction of leaf open times in helical tomotherapy

Purpose: The binary multileaf collimator (MLC) is one of the most important components in helical tomotherapy (HT), as it modulates the dose delivered to the patient. However, methods to ensure MLC quality in HT treatments are lacking. The authors obtained data on the performance of the MLC in treatments administered in their department in order to assess possible delivery errors due to the MLC. Correction methods based on their data are proposed. Methods: Twenty sinograms from treatments delivered using both of the authors HT systems were measured and analyzed by recording the fluence collected by the imaging detector. Planned and actual sinograms were compared using distributions of leaf open time (LOT) errors, as well as differences in fluence reconstructed at each of the 51 projections into which the treatment planning system divides each rotation for optimization purposes. They proposed and applied a method based on individual leaf error correction and the increase in projection time to prevent latency effects when LOT is close to projection time. In order to analyze the dosimetric impact of the corrections, inphantom measurements were made for four corrected treatments. Results: The LOTs measured were consistent with those planned. Most of the mean errors in LOT distributions were within 1 ms with standard deviations of over 4 ms. Reconstructed fluences showed good results, with over 90% of points passing the 3% criterion, except in treatments with a short mean LOT, where the percentage of passing points was as low as 66%. Individual leaf errors were as long as 4 ms in some cases. Corrected sinograms improved error distribution, with standard deviations of over 3 ms and increased percentages of points passing 3% in the fluence per angle analysis, especially in treatments with a short mean LOT and those that were more subject to latency effects. The minimum percentage of points within 3% increased to 86%. In-phantom measurements of the corrected treatments showed that, while treatments affected by latency effects were improved, those affected by individual leaf errors were not. Conclusions: Measurement of MLC performance in real treatments provides the authors with a valuable tool for ensuring the quality of HT delivery. The LOTs of MLC are very accurate in most cases. Sources of error were found and correction methods proposed and applied. The corrections decreased the amount of LOT errors. The dosimetric impact of these corrections should be evaluated more thoroughly using 3D dose distribution analysis.

07 ISOTOPE AND RADIATION SOURCES↗

Risk-Aware Framework Development for Disruption Prediction: Alcator C-Mod and DIII-D Survival Analysis

Abstract Survival regression models can achieve longer warning times at similar receiver operating characteristic performance than previously investigated models. Survival regression models are also shown to predict the time until a disruption will occur with lower error than other predictors. Time-to-event predictions from time-series data can be obtained with a survival analysis statistical framework, and there have been many tools developed for this task which we aim to apply to disruption prediction. Using the open-source Auton-Survival package we have implemented disruption predictors with the survival regression models Cox Proportional Hazards, Deep Cox Proportional Hazards, and Deep Survival Machines. To compare with previous work, we also include predictors using a Random Forest binary classifier, and a conditional Kaplan-Meier formalism. We benchmarked the performance of these five predictors using experimental data from the Alcator C-Mod and DIII-D tokamaks by simulating alarms on each individual shot. We find that developing machine-relevant metrics to evaluate models is an important area for future work. While this study finds cases where disruptive conditions are not predicted, there are instances where the desired outcome is produced. Giving the plasma control system the expected time-to-disruption will allow it to determine the optimal actuator response in real time to minimize risk of damage to the device.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The inter- and intrafraction reproducibilities of three common IMRT delivery techniques

Purpose: Intensity modulated radiation therapy (IMRT) treatment delivery requires higher precision than conventional 3D treatment delivery because of the sensitivity of the resulting dose to small geometric misalignment of the modulated beamlets. The chosen treatment delivery technique will affect the treatment precision in different ways, based on the characteristics of the delivery method. Delivery using a multileaf collimator (MLC) can reduce treatment time and therapist workload, but typically requires a greater number of monitor units and the fields are prone to both systematic and random leaf positioning errors. An alternative to MLC-based fields, patient specific brass compensators, do not suffer from these leaf positioning errors. In our study, we set out to investigate which delivery method will provide the highest levels of dosimetric reproducibility and the minimum amount of interfraction variability. Methods: In our study, a seven field IMRT plan for a head and neck treatment was created using the Pinnacle{sup 3} treatment planning system and the intensity maps for each field were obtained. The intensity maps of the fields were delivered with a Varian 2100C/D linear accelerator, using solid compensators and sliding window (SW) and step-and-shoot (SS) MLC segments. Three fields were selected from the seven-beam IMRT plan for comparison. Analysis was carried out using the MatriXX ion chamber array, radiochromic film, and Varian dynalog files. Results: Our results show that the error in MLC leaf positioning has no gantry angle dependence. The compensator and SW deliveries showed excellent agreement, even when stricter than usual gamma criteria were applied. However, we noted that under these strict conditions, the SS fields had at least ten times more pixels out of range than did the compensators. When using step-and-shoot MLC fields, it was observed that the increase in dose rate or the increase of MU/segment degrades the quality of the plan. Analysis of the dynalog files showed that while each individual field had its own propensity for error, all fields showed the same trend: a greater percentage of time the leaves are out of position as dose rate increases, MUs decrease, or both. Conclusions: The compensator-based field and both types of MLC-based fields have MatriXX results that are within the clinically acceptable tolerance of 3% dose difference and 2 mm DTA. However, when the criteria are tightened, it becomes evident that the compensators have a definite advantage over their comparable MLC-based competitors in terms of interfraction reproducibility. Fewer monitor units are required to deliver each portal, potentially improving patient outcomes and reducing unwanted side effects to both patients and therapists. In centers without MLC, compensators represent a simple and cost effective way to offer patients state of the art treatment. Based on the results of this study, compensator-based IMRT is a reliable, viable option for use in clinics both with and without MLC-equipped linacs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Inverse Solutions in Spectroscopic Analysis with Applications to Problems in Global Safeguards

This work describes a nondestructive strategy and algorithm designed to evaluate the burnup and plutonium content of light-water-reactor spent fuel and thereby confirm declared values. In contrast with previous methods that focus on only a few photopeaks (e.g., 137 Cs at 662 keV), the present approach involves the entire gamma spectrum up to 2000 keV. Spectra are used as input for the inverse code INDEPTH, which is designed to predict reactor parameters (fuel enrichment, power level, irradiation time, and cooling time) when given either a set of nuclide inventories or the gamma spectrum that they produce. This approach has the advantage of often making possible the determination of parameters other than burnup when they are unknown or in doubt. In addition, error in one photopeak evaluation is mitigated by the inclusion of the entire spectrum. The solution procedure involves multiple runs of the forward code ORIGEN/ARP, each of which produces an extensive list of nuclides formed through depletion/decay processes. The gamma spectrum of these nuclides is compared with the gamma spectrum from a detector through a bin-by-bin sum of squared error. New choices for the reactor parameters that are input to ORIGEN/ARP are determined using a gradient search technique, and the best parameter set is that which minimizes the squared error between calculated and measured gamma spectra. The method is applied to the analysis of gamma data taken from various sections of actual spent reactor fuel and is compared with declared values and other methods of evaluation. The sensitivity of the inverse solution with respect to various parameters is calculated and indicates that the algorithm is stable and robust. One example includes the presence of multiple solutions, each of which can be characterized using additional information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An improved method to increase the predictive accuracy of the ECR technique

The technique of electrical conductivity relaxation (ECR) is a widely utilized method for obtaining oxygen chemical surface exchange (k) and bulk diffusion (D) coefficients for mixed ionic electronic conductors. Although the technique is conceptually simple, its practical application does not frequently produce reliably accurate values of k and D, and many examples of poor agreement can be found in the published literature. In this present paper, methods for enhancing the accuracy of the ECR technique relative to data processing are described in detail. Physically accurate determination of the actual starting time (t{sub 0}) and improved methods for data fitting of ECR measurements are discussed. To test the methods described, generated relaxation data sets are analyzed by using non-linear-least-square (NLLS) methods. The results showed that fixing t{sub 0} based on an ideally stirred reactor model improves the fitted results compared to treating t{sub 0} as a fitted parameter. Additionally, evaluation of the global minimum in the fitted error is made by analyzing multiple samples of varying thickness, which improves parameter evaluation compared to analysis of a single relaxation data set. The improved accuracy of the computed values of k and D is described in comparison to conventional methods.

Bulk diffusion coefficient↗

Surrogate Model of Flexible Research Platform EnergyPlus Models to Enable Sensitivity Analysis

This letter report describes the surrogate models developed from the EnergyPlus model of Oak Ridge National Laboratory’s Flexible Research Platform. Two data-driven black-box models were developed, and the outputs of the surrogate models were compared with the EnergyPlus model. The two models developed are a multilayer perceptron deep learning model, and a long short-term memory (LSTM) neural network model. The three factors for selecting the black-box models are scalability, computation time, and accuracy. A total of 107 input variables were the dominant variables in determining the outputs of building energy consumptions and thermal comfort. A total of 54 output variables were identified as the prediction targets, including the system- and zone-level outputs. The large set of the simulation cases were generated by integrating sensor errors into an emulator based on EnergyPlus and Python EMS, which includes advanced control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. The surrogate models were developed based on a set of large-scale simulation runs (i.e., 4,000 runs) on a cloud platform. The comparison analysis shows that the two black-box models had good accuracy for predicting new outputs for sensitivity analysis using the root mean square error metric. As a next step, the developed surrogate models will be used to perform sensitivity analysis for different sensor impacts (e.g., sensor types, sensor locations).

42 ENGINEERING↗

Analysis and Synthesis of Load Forecasting Data for Renewable Integration Studies: Preprint

As renewable energy constitutes greater portions of the generation fleet, the importance of modeling uncertainty as part of integration studies also increases. In pursuit of optimal system operations, it is important to capture not only the definitive behavior of power plants, but also the risks associated with systemwide interactions. This research examines the dependence of load forecast errors on external predictor variables such as temperature, day type, and time of day. The analysis was utilized to create statistically relevant instances of sequential load forecasts with only a time series of historic, measured load available. The creation of such load forecasts relies on Bayesian techniques for informing and updating the model, thus providing a basis for networked and adaptive load forecast models in future operational applications.

17 WIND ENERGY↗

SNS Sample Activation Calculator Flux Recommendations and Validation

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) uses the Sample Activation Calculator (SAC) to calculate the activation of a sample after the sample has been exposed to the neutron beam in one of the SNS beamlines. The SAC webpage takes user inputs (choice of beamline, the mass, composition and area of the sample, irradiation time, decay time, etc.) and calculates the activation for the sample. In recent years, the SAC has been incorporated into the user proposal and sample handling process, and instrument teams and users have noticed discrepancies in the predicted activation of their samples. The Neutronics Analysis Team validated SAC by performing measurements on select beamlines and confirmed the discrepancies seen by the instrument teams and users. The conclusions were that the discrepancies were a result of a combination of faulty neutron flux spectra for the instruments, improper inputs supplied by SAC (1.12), and a mishandling of cross section data in the Sample Activation Program for Easy Use (SAPEU) (1.1.2). This report focuses on the conclusion that the SAPEU (1.1.2) beamline neutron flux spectra have errors and are a significant contributor to the activation discrepancies. The results of the analysis of the SAPEU (1.1.2) flux spectra for all beamlines will be discussed in detail. The recommendations for the implementation of improved neutron flux spectra in SAPEU (1.1.3) are also discussed.

43 PARTICLE ACCELERATORS↗

A Full Multigrid Method for the Self-Adjoint Angular Flux Equation Based on Cellwise Block Jacobi Iteration

Previous work by Densmore et al. has demonstrated that multigrid methods for the self-adjoint angular flux (SAAF) equation with cellwise block Jacobi smoothing can be extremely effective at solving for the angular flux in one dimension. The extension of that work to two dimensions demonstrated that while the smoother works well, the use of a direct coarse-grid approximation can severely limit the rate of convergence for optically thin cells. In that paper, this convergence limit was evaded through the use of a partially Galerkin coarse-grid approximation. However, relying on a Galerkin coarse-grid approximation is not ideal as constructing the coarse-grid discretization in this approach is complicated. The motivation for this summary is to find a method that can work without the need for a Galerkin coarse-grid approximation. The Full Multigrid (FMG) method is well known as a method that can theoretically solve a problem to its discretization accuracy with optimal linear computational complexity, that is in just O(N) operations for N unknowns. Indeed, we develop an FMG method for the 2-D SAAF equation that yields discretization accuracy and does not require the use of a Galerkin coarse-grid approximation. Until recently, aside from proofs about the order of the error for FMG, little work had been done in quantifying when and how FMG can obtain discretization accuracy. However, recent work by Rodrigo et al. has introduced a Fourier analysis technique called worst-case right-hand side analysis used to calculate the FMG accuracy measure. The FMG accuracy measure is the upper bound on the constant of proportionality between the error of the FMG solution and the discretization error. In this summary, we develop and implement an FMG method for the 2-D Cartesian SAAF equations. We then perform worst-case right-hand side analysis and give numerical examples that demonstrate under what circumstances the method can solve the 2-D SAAF equations to discretization accuracy, for optically thin cells, without the need for a Galerkin coarse-grid approximation. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗