Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Simulating Alpha Particles Incident on MKID Chips for Quantum Sensitivity Analysis

Superconducting quantum devices, such as microwave kinetic inductance detectors (MKIDs), are highly sensitive instruments used in quantum computing and advanced sensing technologies. However, their extreme sensitivity also makes them vulnerable to background noise from natural sources like radiation. One significant contributor to this noise is alpha particles emitted by 210Po, a radon decay daughter that accumulates on surfaces near the detector. This project investigates how alpha particles emitted from 210Po interact with MKID chips. These particles can deposit energy on the detector surface, disrupting its operation and generating false signals. Understanding the energy and behavior of these particles is crucial for improving the design and reliability of quantum devices. To explore this, we first modeled the decay chain starting from 210Pb to 210Po using differential equations. This allowed us to predict how the activity of alpha-emitting isotopes changes over time, reaching a steady state after about two years. Next, we simulated alpha particle interactions with the MKID chip using the Geant4 software toolkit. We built a detailed computer model of the detector housing, including the copper lid where alpha particles originate, the silicon chip, and a thin aluminum sensor layer. Alpha particles were emitted isotropically from just beneath the copper lid’s surface, mimicking natural decay conditions. The simulation tracked how these particles deposit energy on the chip, generating electron-hole pairs and phonons. The results provide insight into the behavior of the resultant electron-hole pairs and phonons, giving us a clear understanding of the energy deposition distribution on the chip. This work supports efforts to mitigate background noise in superconducting sensors, advancing their use in quantum computing and sensitive physics experiments.

Hall, Matthew [Fermilab; UCLA]↗

Artificial Intelligence for imaging Cherenkov detectors at the EIC

Abstract Imaging Cherenkov detectors form the backbone of particle identification (PID) at the future Electron Ion Collider (EIC). Currently all the designs for the first EIC detector proposal use a dual Ring Imaging CHerenkov (dRICH) detector in the hadron endcap, a Detector for Internally Reflected Cherenkov (DIRC) light in the barrel, and a modular RICH (mRICH) in the electron endcap. These detectors involve optical processes with many photons that need to be tracked through complex surfaces at the simulation level, while for reconstruction they rely on pattern recognition of ring images. This proceeding summarizes ongoing efforts and possible applications of AI for imaging Cherenkov detectors at EIC. In particular we will provide the example of the dRICH for the AI-assisted design and of the DIRC for simulation and particle identification from complex patterns and discuss possible advantages of using AI.

Instruments & Instrumentation↗

WE-D-303-05: Dosimetric Accuracy of CBCT Images Estimated by a Motion Modeling and Free-Form Deformation Technique for Radiotherapy of Lung Cancer

Purpose: To investigate the dosimetric accuracy of CBCTs estimated by a motion modeling and free-form deformation(MM-FD) technique for radiotherapy of lung cancer. Methods: Various inter-fractional variations featuring patient motion pattern change, tumor size change and tumor average position change were simulated from planning-CT to on-board images using both digital and physical motion phantoms. The doses calculated on the planning-CT (planned doses), the on-board CBCT estimated by MM-FD (MM-FD doses) and the on-board CBCT reconstructed by the conventional Feldkamp-Davis-Kress(FDK) algorithm (FDK doses) were compared to the on-board dose calculated on the ‘gold-standard’ on-board images (gold-standard doses). The absolute deviations of minimum dose (dDmin), maximum dose (dDmax), mean dose (dDmean) and dose coverage (dV100%) of PTV were evaluated. In addition, 4D on-board dose accumulations were performed using the 4D-CBCT images estimated by MM-FD. The accumulated doses were compared to measurements using OSL detectors and radiochromic films. Results: Of all the 50 scenarios simulated, the average(± standard deviation) dDmin, dDmax, dDmean and dV100% (values normalized by the prescription dose or the PTV volume) between the planned and the gold-standard PTV doses were 34.8% (± 29.2%), 3.2% (± 3.8%), 3.5% (± 3.5%) and 13.0% (± 11.4%), respectively. The corresponding values of FDK PTV doses were 3.1% (± 3.7%), 1.4% (± 1.1%), 2.1% (± 0.8%) and 14.5% (± 14.2%), respectively. In contrast, the corresponding values of MM-FD PTV doses were 0.4% (± 0.5%), 0.9% (± 0.7%), 0.6% (± 0.4%) and 0.9% (± 0.8%), respectively.For the 4D dose accumulation study, the average(± standard deviation) absolute dose deviation (normalized by local doses) between the accumulated doses and the OSL measured doses was 3.0% (± 2.4%). The average gamma pass-rate(3%/3mm) between the accumulated doses and the radiochromic film measured doses was 96.1%. Conclusion: MM-FD estimated CBCT enables accurate on-board dose calculation and accumulation for lung radiation therapy. The research was funded by the National Institutes of Health Grant No. R01-CA184173 and a grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Phased plan for the implementation of the time-resolving magnetic recoil spectrometer on the National Ignition Facility (NIF)

The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately—namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 10 17 . The PDDT will be used for optimal efficiency and resolution in phase 3.

47 OTHER INSTRUMENTATION↗

CMS Full Simulation for Run 3

We report the status of the CMS full simulation for Run 3. During the long shutdown of the LHC a significant update has been introduced to the CMS code for simulation. The CMS geometry description is reviewed. Several important modifications were needed. CMS detector description software is migrated to the DD4Hep community developed tool. We will report on our experience obtained during the process of this migration. Geant4 10.7 is the CMS choice for Run 3 simulation productions. We will discuss arguments for this choice, the strategy of adaptation of a new Geant4 version, and will report on the physics performance of the CMS simulation. A special Geant4 Physics List configuration FTFP_BERT_EMM will be described, which provides a compromise between simulation accuracy and CPU performance. A significant fraction of time for simulation of CMS events is spent on tracking of charged particles in a magnetic field. In the CMS simulation a dynamic choice of Geant4 parameters for tracking in field is implemented. A new method is introduced into simulation of electromagnetic components of hadronic showers in the electromagnetic calorimeter of CMS. For low-energy electrons and positrons a parametrization of GFlash type is applied. Results of tests of this method will be discussed. In summary, we expect about 25% speedup of the CMS simulation production for Run 3 compared to the Run 2 simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On geometric factors for neutral particle analyzers

Neutral particle analyzers (NPA) detect neutralized energetic particles that escape from plasmas. Geometric factors relate the counting rate of the detectors to the intensity of the particle source. Accurate geometric factors enable quick simulation of geometric effects without the need to resort to slower Monte Carlo methods. Previously derived expressions [G. R. Thomas and D. M. Willis, “Analytical derivation of the geometric factor of a particle detector having circular or rectangular geometry,” J. Phys. E: Sci. Instrum. 5(3), 260 (1972); J. D. Sullivan, “Geometric factor and directional response of single and multi-element particle telescopes,” Nucl. Instrum. Methods 95(1), 5–11 (1971)] for the geometric factor implicitly assume that the particle source is very far away from the detector (far-field); this excludes applications close to the detector (near-field). The far-field assumption does not hold in most fusion applications of NPA detectors. We derive, from probability theory, a generalized framework for deriving geometric factors that are valid for both near and far-field applications as well as for non-isotropic sources and nonlinear particle trajectories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibrating and training of neutron based NSA techniques with less SNM standards

Accessing special nuclear material (SNM) standards for the calibration of and training on nondestructive assay (NDA) instruments has become increasingly difficult in light of enhanced safeguards and security regulations. Limited or nonexistent access to SNM has affected neutron based NDA techniques more than gamma ray techniques because the effects of multiplication require a range of masses to accurately measure the detector response. Neutron based NDA techniques can also be greatly affected by the matrix and impurity characteristics of the item. The safeguards community has been developing techniques for calibrating instrumentation and training personnel with dwindling numbers of SNM standards. Monte Carlo methods have become increasingly important for design and calibration of instrumentation. Monte Carlo techniques have the ability to accurately predict the detector response for passive techniques. The Monte Carlo results are usually benchmarked to neutron source measurements such as californium. For active techniques, the modeling becomes more difficult because of the interaction of the interrogation source with the detector and nuclear material; and the results cannot be simply benchmarked with neutron sources. A Monte Carlo calculated calibration curve for a training course in Indonesia of material test reactor (MTR) fuel elements assayed with an active well coincidence counter (AWCC) will be presented as an example. Performing training activities with reduced amounts of nuclear material makes it difficult to demonstrate how the multiplication and matrix properties of the item affects the detector response and limits the knowledge that can be obtained with hands-on training. A neutron pulse simulator (NPS) has been developed that can produce a pulse stream representative of a real pulse stream output from a detector measuring SNM. The NPS has been used by the International Atomic Energy Agency (IAEA) for detector testing and training applications at the Agency due to the lack of appropriate SNM standards. This paper will address the effect of reduced access to SNM for calibration and training of neutron NDA applications along with the advantages and disadvantages of some solutions that do not use standards, such as the Monte Carlo techniques and the NPS.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the possibility to discriminate the mass of the primary cosmic ray using the muon arrival times from extensive air showers: Application for Pierre Auger Observatory

In this paper we study the possibility to discriminate the mass of the primary cosmic ray by observing the muon arrival times in ground detectors. We analyzed extensive air showers (EAS) induced by proton and iron nuclei with the same energy 8 Multiplication-Sign 10{sup 17} eV simulated with CORSIKA, and analyzed the muon arrival times at ground measured by the infill array detectors of the Pierre Auger Observatory (PAO). From the arrival times of the core and of the muons the atmospheric depth of muon generation locus is evaluated. The results suggest a potential mass discrimination on the basis of muon arrival times and of the reconstructed atmospheric depth of muon production. An analysis of a larger set of CORSIKA simulations carried out for primary energies above 10{sup 18} eV is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Performance of LHCf Detector

In cosmic ray physics, the uncertainty of the hadron interaction model causes systematic errors of air shower simulations in high-energy region. To solve the problem, the LHCf experiment measures energies and transverse momenta of neutral particles emitted in the forward region of 14 TeV p-p collision at CERN LHC. Two LHCf detectors, consisting of sampling and imaging calorimeters, are installed at zero degree collision angle at + 140 m from the interaction point 1 (IP1). The energy resolution is confirmed as to be <5% and the position resolution <0.2 mm for gamma-rays with energies from 100 GeV to 200 GeV by test beam results at the CERN SPS. Use of the Front Counter reduces the beam-gas background by a factor 50.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Costas loop lock detection in the advanced receiver

The advanced receiver currently being developed uses a Costas digital loop to demodulate the subcarrier. Previous analyses of lock detector algorithms for Costas loops have ignored the effects of the inherent correlation between the samples of the phase-error process. Accounting for this correlation is necessary to achieve the desired lock-detection probability for a given false-alarm rate. Both analysis and simulations are used to quantify the effects of phase correlation on lock detection for the square-law and the absolute-value type detectors. Results are obtained which depict the lock-detection probability as a function of loop signal-to-noise ratio for a given false-alarm rate. The mathematical model and computer simulation show that the square-law detector experiences less degradation due to phase jitter than the absolute-value detector and that the degradation in detector signal-to-noise ratio is more pronounced for square-wave than for sine-wave signals.

Mileant, A.↗

Molecular dynamics discovery of an extraordinary ionic migration mechanism in dislocation-containing TlBr crystals

TlBr can surpass CZT as the leading semiconductor for γ- and X-radiation detection. Unfortunately, the optimum properties of TlBr quickly decay when an operating electrical field is applied. Quantum mechanical studies indicated that if this property degradation comes from the conventional mechanism of ionic migration of vacancies, then an unrealistically high vacancy concentration is required to account for the rapid aging of TlBr seen in experiments. Here, we have applied large scale molecular dynamics simulations to study the effects of dislocations on ionic migration of TlBr crystals under electrical fields. We found that electrical fields can drive the motion of edge dislocations in both slip and climb directions. These combined motions eject enormous vacancies in the dislocation trail. Both dislocation motion and a high vacancy concentration can account for the rapid aging of the TlBr detectors. These findings suggest that strengthening methods to pin dislocations should be explored to increase the lifetimes of TlBr crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Analysis-Specific Fast Simulation at the LHC with Deep Learning

Abstract We present a fast-simulation application based on a deep neural network, designed to create large analysis-specific datasets. Taking as an example the generation of W + jet events produced in $$\sqrt{s}=$$ s = 13 TeV proton–proton collisions, we train a neural network to model detector resolution effects as a transfer function acting on an analysis-specific set of relevant features, computed at generation level, i.e., in absence of detector effects. Based on this model, we propose a novel fast-simulation workflow that starts from a large amount of generator-level events to deliver large analysis-specific samples. The adoption of this approach would result in about an order-of-magnitude reduction in computing and storage requirements for the collision simulation workflow. This strategy could help the high energy physics community to face the computing challenges of the future High-Luminosity LHC.

Chen, C.↗

A flexible event reconstruction based on machine learning and likelihood principles

Event reconstruction is a central step in many particle physics experiments, turning detector observables into parameter estimates; for example estimating the energy of an interaction given the sensor readout of a detector. A corresponding likelihood function is often intractable, and approximations need to be constructed. Here, in our work, we first show how the full likelihood for a many-sensor detector can be broken apart into smaller terms, and secondly how we can train neural networks to approximate all terms solely based on forward simulation. Our technique results in a fast, flexible, and close-to-optimal surrogate model proportional to the likelihood and can be used in conjunction with standard inference techniques allowing for a consistent treatment of uncertainties. We illustrate our technique for parameter inference in neutrino telescopes based on maximum likelihood and Bayesian posterior sampling. Given its great flexibility, we also showcase our method for geometry optimization enabling to learn optimal detector designs. Lastly, we apply our method to realistic simulation of a ton-scale water-based liquid scintillator detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operation and performance of the ATLAS semiconductor tracker

The semiconductor tracker is a silicon microstrip detector forming part of the inner tracking system of the ATLAS experiment at the LHC. The operation and performance of the semiconductor tracker during the first years of LHC running are described. More than 99% of the detector modules were operational during this period, with an average intrinsic hit efficiency of (99.74±0.04)%. The evolution of the noise occupancy is discussed, and measurements of the Lorentz angle, d-ray production and energy loss presented. The alignment of the detector is found to be stable at the few-micron level over long periods of time. Radiation damage measurements, which include the evolution of detector leakage currents, are found to be consistent with predictions and are used in the verification of radiation background simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Progress in the design of the future circular collider FCC-ee interaction region

In this paper we discuss the latest developments for the FCC-ee interaction region layout, which represents one of the key ingredients to establish the feasibility of the FCC-ee. The collider has to achieve extremely high luminosities over a wide range of center-of-mass energies with two or four interaction points. The complex final focus hosted in the detector region has to be carefully designed, and the impact of beam losses and of any type of synchrotron radiation generated in the interaction region, including beamstrahlung, have to be evaluated in detail with simulations. We give an overview of the progress of the whole machine-detector-interface-related studies, among which are the updated mechanical model of the interaction region, the plans for a novel R&D activity of a IR mockup which is just starting, the collimation scheme and evaluation of beam induced backgrounds in the detectors, evaluation of radiation dose in the experimental area, and MDI integration with the detector.

43 PARTICLE ACCELERATORS↗

Experimental concept and design of DarkLight, a search for a heavy photon

This talk gives an overview of the DarkLight experimental concept: a search for a heavy photon A′ in the 10-90 MeV/c{sup 2} mass range. After briefly describing the theoretical motivation, the talk focuses on the experimental concept and design. Topics include operation using a half-megawatt, 100 MeV electron beam at the Jefferson Lab FEL, detector design and performance, and expected backgrounds estimated from beam tests and Monte Carlo simulations.

43 PARTICLE ACCELERATORS↗

Technology for satellite power conversion

The work is this reporting period was concentrated on electronically calibrating the bolometer detectors. The calibration is necessary for two reasons: first, the power delivered to the rectifying circuit must be known in order to choose a diode with the appropriate barrier height, and second, the power captured by the antenna must be measured if the efficiency of the rectenna is to be divided into antenna efficiency and rectification efficiency. The millimeter wave region operation of the bolometers was simulated with a VHF (10 to 90 MHz) test signal. These detectors are accurate to within roughly 10%. The typical responsivity of the bolometers is 10 volts/watt and the NEP at 20 Hz is 5 times 10 to the minus 9th power W(Hz)-1/2.

Gouker, M. A.↗