Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Aqua MODIS 8-Year On-Orbit Operation and Calibration

Launched in May 2002, the NASA EOS Aqua MODIS has successfully operated for more than 8 years. Observations from Aqua MODIS and its predecessor, Terra MODIS, have generated an unprecedented amount of data products and made significant contributions to studies of changes in the Earth s system of land, oceans, and atmosphere. MODIS collects data in 36 spectral bands: 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). It has a set of on-board calibrators (OBC), providing sensor on-orbit radiometric, spectral, and spatial calibration and characterization. This paper briefly summarizes Aqua MODIS on-orbit operation and calibration activities and illustrates instrument on-orbit performance from launch to present. Discussions are focused on OBC functions and changes in detector radiometric gains, spectral responses, and spatial registrations. With ongoing calibration effort, Aqua MODIS will continue serving the science community with high quality data products

Xiong, Xiaoxiong↗

PACE OCI Short-Wave Infrared Detection Assembly Optical System Design, Alignment, and Environmental Test

The Ocean Color Instrument (OCI), which will be integrated with the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) satellite, will collect science data that will be used to monitor the health of Earth’s oceans and atmosphere. The Short-Wave Infrared (SWIR) Detection Assembly (SDA), built and characterized by Utah State University Space Dynamics Laboratory (SDL), is a subsystem of OCI consisting of 32 channels covering seven discrete optical bands of interest. A total of 16 SWIR Detection Subassemblies (SDSs) compose the SDA and house the cold optical system. The science data optical input for each SDS is supplied by a 0.22 NA multimode fiber interfacing with a fiber adapter. The diverging light from the fiber is collimated, split by a dichroic beamsplitter to two separate channels, filtered by the science filter, and then reimaged onto the single-element detectors with a final 0.76 NA. Aspheric, diamond-turned powered elements are used throughout the optical design. Fabrication and alignment tolerance analysis/budgets are balanced to ensure the optical system meets throughput requirements. All systems are aligned at ambient temperature using an InSb camera and an in-line illumination microscope system to directly image the active detector area through the science filters. Compensators used during alignment are detector focus and decenter, which are adjusted via photoetched shims in increments of 25 µm. Average focus and centering errors were less than 8 µm among all 32 flight and 10 flight spare detectors. Each SDS spectral response and conversion gain was verified at operational temperature of -65°C in vacuum.

OCI↗

Hydrogen Equipment Enclosure Risk Reduction through Earlier Detection of Component Failures

Hydrogen component reliability and the hazard associated with failure rates is a critical area of research for the successful implementation and growth of hydrogen technology across the globe. The research team has partnered to quantify system risk reduction through earlier detection of hydrogen component failures. A model of hydrogen dispersion in a hydrogen equipment enclosure has been developed utilizing experimentally quantified hydrogen component leak rates as inputs. This model provides insight into the impact of hydrogen safety sensors and ventilation on the flammable mass within a hydrogen equipment enclosure. This model also demonstrates the change in safety sensor response time due to detector placement under various leak scenarios. The team looks to improve overall hydrogen system safety through an improved understanding of hydrogen component reliability and risk mitigation methods. This collaboration fits under the work program of IEA Hydrogen Task 43 Subtask E Hydrogen System Safety.

CFD↗

Binary Pseudo-random Grating Standard for Calibration of Surface Profilometers

We suggest and describe the use of a binary pseudo-random (BPR) grating as a standard test surface for measurement of the modulation transfer function (MTF) of interferometric microscopes. Knowledge of the MTF of a microscope is absolutely necessary to convert the measured height distribution of a surface undergoing metrology into an accurate power spectral density (PSD) distribution. For an'ideal' microscope with an MTF function independent of spatial frequency out to the Nyquist frequency of the detector array with zero response at higher spatial frequencies, a BPR grating would produce a flat 1D PSD spectrum, independent of spatial frequency. For a'real' instrument, the MTF is found as the square root of the ratio of the PSD spectrum measured with the BPR grating to the'ideal,' spatial frequency independent, PSD spectrum. We present the results from a measurement of the MTF of MicromapTM-570 interferometric microscope demonstrating a high efficiency for the calibration method.

, standards, surface roughness, interference micro↗

Cosmic-ray physics with the milagro gamma-ray observatory

The Milagro gamma-ray observatory is a water Cherenkov detector with an energy response between 100 GeV and 100 TeV. While the major scientific goals of Milagro were to detect and study cosmic sources of TeV gamma rays, Milagro has made measurements important to furthering our understanding of the cosmic radiation that pervades our Galaxy. Milagro has made the first measurement of the Galactic diffuse emission in the TeV energy band. In the Cygnus Region we measure a flux {approx}2.7 times that predicted by GALPROP. Milagro has also made measurements of the anisotropy of the arrival directions of the local cosmic radiation. On large scales the measurements made by Milagro agree with those previously reported by the Tibet AS{gamma} array. However, we have also discovered a time dependence to this anisotropy, perhaps due to solar modulation. On smaller scales, {approx}10 degrees, we have detected two regions of excess. These excesses have a spectrum that is inconsistent with the local cosmic-ray spectrum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray detectors based on GaN Schottky diodes

GaN Schottky diodes have been fabricated and tested as x-ray detectors in the range from 6 to 21 keV. The spectral response has been measured and is compared to its theoretical value. The study of the response and its temporal dynamics as a function of the bias allows to identify a photovoltaic behavior at low bias and a photoconductive one at larger reverse biases. The GaN diode turned out to be linear as a function of the incident power. The noise and detectivity are given and discussed.

36 MATERIALS SCIENCE↗

A cascaded model of spectral distortions due to spectral response effects and pulse pileup effects in a photon-counting x-ray detector for CT

Purpose: Energy discriminating, photon-counting detectors (PCDs) are an emerging technology for computed tomography (CT) with various potential benefits for clinical CT. The photon energies measured by PCDs can be distorted due to the interactions of a photon with the detector and the interaction of multiple coincident photons. These effects result in distorted recorded x-ray spectra which may lead to artifacts in reconstructed CT images and inaccuracies in tissue identification. Model-based compensation techniques have the potential to account for the distortion effects. This approach requires only a small number of parameters and is applicable to a wide range of spectra and count rates, but it needs an accurate model of the spectral distortions occurring in PCDs. The purpose of this study was to develop a model of those spectral distortions and to evaluate the model using a PCD (model DXMCT-1; DxRay, Inc., Northridge, CA) and various x-ray spectra in a wide range of count rates. Methods: The authors hypothesize that the complex phenomena of spectral distortions can be modeled by: (1) separating them into count-rate independent factors that we call the spectral response effects (SRE), and count-rate dependent factors that we call the pulse pileup effects (PPE), (2) developing separate models for SRE and PPE, and (3) cascading the SRE and PPE models into a combined SRE+PPE model that describes PCD distortions at both low and high count rates. The SRE model describes the probability distribution of the recorded spectrum, with a photo peak and a continuum tail, given the incident photon energy. Model parameters were obtained from calibration measurements with three radioisotopes and then interpolated linearly for other energies. The PPE model used was developed in the authors’ previous work [K. Taguchi et al., “Modeling the performance of a photon counting x-ray detector for CT: Energy response and pulse pileup effects,” Med. Phys. 38(2), 1089–1102 (2011)]. The agreement between the x-ray spectra calculated by the cascaded SRE+PPE model and the measured spectra was evaluated for various levels of deadtime loss ratios (DLR) and incident spectral shapes, realized using different attenuators, in terms of the weighted coefficient of variation (COV{sub W}), i.e., the root mean square difference weighted by the statistical errors of the data and divided by the mean. Results: At low count rates, when DLR < 10%, the distorted spectra measured by the DXMCT-1 were in agreement with those calculated by SRE only, with COV{sub W}'s less than 4%. At higher count rates, the measured spectra were also in agreement with the ones calculated by the cascaded SRE+PPE model; with PMMA as attenuator, COV{sub W} was 5.6% at a DLR of 22% and as small as 6.7% for a DLR as high as 55%. Conclusions: The x-ray spectra calculated by the proposed model agreed with the measured spectra over a wide range of count rates and spectral shapes. The SRE model predicted the distorted, recorded spectra with low count rates over various types and thicknesses of attenuators. The study also validated the hypothesis that the complex spectral distortions in a PCD can be adequately modeled by cascading the count-rate independent SRE and the count-rate dependent PPE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Designing the Neutron Detector for the NEXUS Test Facility

The SuperCDMS dark matter experiment is commissioning a new test facility at Fermilab, NEXUS, capable of testing a new suite of detectors that promise to push to lower dark matter masses than has previously been achieved. These detectors use silicon and germanium, cooled to tens of mK, to measure small vibrations in the crystal lattice caused by very tiny energy deposits. A core capability of NEXUS test facility is to use a commercial neutron generator, coupled to an array of detectors behind the test facility, to calibrate the nuclear recoil energy scale of these detectors through neutron scattering. The response of silicon and germanium to nuclear recoils below 1 keV energy transfer is largely unknown. For dark matter models which are primarily interacting with the nucleus, calibration of this response will completely determine the dark matter sensitivity of the experiment. In this context, the proper design of the neutron tagging detector to be used in the test facility needs to be found. This work will include simulation of the detector behavior and work towards an optimization of the detector geometry based on measurement resolution and detection rate. In addition, prototype scintillators and photodetectors will be studied as candidate detector elements.

47 OTHER INSTRUMENTATION↗

Radiometric calibration of the airborne imaging spectrometer

Several laboratory calibration tests were developed for the Airborne Imaging Spectrometer (AIS). The goals of these tests are to adjust the physical alignment of the detector within the optical system and set the spectral endpoints, and produce a calibration file of multipliers which equalizes the relative responses of each of the detector elements in the entire two-dimensional array. Tests are also performed as part of an ongoing effort to provide absolute radiometric calibration. The tests are described and the merits and limitations of each are discussed.

Tucker, D.↗

Gadolinium Thin Foils in a Plasma Panel Sensor as an Alternative to 3He

Gadolinium has long been investigated as a detector for neutrons. It has a thermal neutron capture cross-section that is unparalleled among stable elements, because of the isotopes $^{155,157}$Gd. As a replacement for $^3$He, gadolinium has a significant defect, it produces many gamma-rays with an energy sum of 8 MeV. It also produces conversion electrons, mostly 29 keV in energy. The key to replacing $^3$He with gadolinium is using a gamma-blind electron detector to detect the conversion electrons. We suggest that coupling a layer of gadolinium to a Plasma Panel Sensor (PPS) can provide highly efficient, nearly gamma-blind detection of the conversion. The PPS is a proposed detector under development as a dense array of avalanche counters based on plasma display technology. We will present simulations of the response of prototypes of this detector and considerations of the use of gadolinium in the PPS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino Meza, Rafael [Unlisted, US; Fermilab]↗

Photodiodes for ten micrometer laser communication systems

The performance is discussed of 10-micron mercury-cadmiumtelluride and lead-tin-telluride photodiodes in laser heterodyne communication systems. The dependence of detector quantum efficiency, resistance, frequency response, and signal-to-noise ratio on temperature, bias, and local oscillator power are examined. Included in the discussion is an analysis of the feasibility of high temperature operation, and ability of the detector to dissipate power to a heat sink is explored. Some aspects of direct detection response are considered and figures showing flux levels from a blackbody presented.

Cohen, S. C.↗

Radiation tolerance of a high quality synthetic single crystal chemical vapor deposition diamond detector irradiated by 14.8 MeV neutrons

Diamond exhibits many properties such as an outstanding radiation hardness and fast response time both important to design detectors working in extremely radioactive environments. Among the many applications these devices can be used for, there is the development of a fast and radiation hard neutron detector for the next generation of fusion reactors, such as the International Thermonuclear Experimental Reactor project, under construction at Cadarache in France. A technology to routinely produce electronic grade synthetic single crystal diamond detectors was recently developed by our group. One of such detectors, with an energy resolution of 0.9% as measured using an {sup 241}Am{alpha} particle source, has been heavily irradiated with 14.8 MeV neutrons produced by the Frascati Neutron Generator. The modifications of its spectroscopic properties have been studied as a function of the neutron fluence up to 2.0x10{sup 14} n/cm{sup 2}. In the early stage of the irradiation procedure an improvement in the spectroscopic performance of the detector was observed. Subsequently the detection performance remains stable for all the given neutron fluence up to the final one thus assessing a remarkable radiation hardness of the device. The neutron damage in materials has been calculated and compared with the experimental results. This comparison is discussed within the nonionizing energy loss (NIEL) hypothesis, which states that performance degradation is proportional to NIEL.

36 MATERIALS SCIENCE↗

Light Output Fitting Software

Light output response of scintillators is crucial to the utilization of organic scintillators as effective tools in radiation detection and measurement. While the response is a continuous distribution, the light output corresponding to the maximum energy deposition is crucial in effectively understanding and simulating a detector. There are a variety of fits derived in literature that will vary for every detector material. The Light Output Response Fitter, or LORF Program is a python script designed to easily and quickly compute and plot fits for a variety of scintillator light output models. It includes a stopping power library constructed from SRIM including Organic Glass, EJ309, EJ301, Stilbene, EJ276, and their deuterated counterparts by default, with the ability for the user to add custom stopping power libraries. The user is also capable of importing the python package and utilizing its in-built functions as appropriate. Uses for this capability include plotting and computing a model with known parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗