Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data acquisition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

10 CFR 830 Major Modification Determination for Advanced Test Reactor RDAS and LPCIS Replacement

The replacement of the ATR Control Complex's obsolete computer based Reactor Data Acquisition System (RDAS) and its safety-related Lobe Power Calculation and Indication System (LPCIS) software application is vitally important to ensure the ATR remains available to support this national mission. The RDAS supports safe operation of the reactor by providing 'real-time' plant status information (indications and alarms) for use by the reactor operators via the Console Display System (CDS). The RDAS is a computer support system that acquires analog and digital information from various reactor and reactor support systems. The RDAS information is used to display quadrant and lobe powers via a display interface more user friendly than that provided by the recorders and the Control Room upright panels. RDAS provides input to the Nuclear Engineering ATR Surveillance Data System (ASUDAS) for fuel burn-up analysis and the production of cycle data for experiment sponsors and the generation of the Core Safety Assurance Package (CSAP). RDAS also archives and provides for retrieval of historical plant data which may be used for event reconstruction, data analysis, training and safety analysis. The RDAS, LPCIS and ASUDAS need to be replaced with state-of-the-art technology in order to eliminate problems of aged computer systems, and difficulty in obtaining software upgrades, spare parts, and technical support. The major modification criteria evaluation of the project design did not lead to the conclusion that the project is a major modification. The negative major modification determination is driven by the fact that the project requires a one-for-one equivalent replacement of existing systems that protects and maintains functional and operational requirements as credited in the safety basis.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-energy X-ray applications: current status and new opportunities

Characterization of semi and noncrystalline materials, monitoring structural phase transitions in situ , and obtaining structural information together with spatial distribution of the investigated material are only a few applications that hugely benefitted from the combination of high-energy X-rays and modern algorithms for data processing. This work examines the possibility of advancing these applications by shortening the data acquisition and improving the data quality by using the new high-energy PILATUS3 CdTe detector.

Šišak Jung, Dubravka (ORCID:000000018702183X)↗

High-Temperature Neutron Diffraction Study of Vanadium and Vanadium–Niobium Null-Matrix Alloy for Spectrum Normalization

This study systematically evaluates a vanadium–niobium (V 94.1 Nb 5.9 ) null-matrix alloy as a reference material for neutron spectrum normalization and compares its performance with that of pure vanadium under identical experimental conditions. Neutron diffraction experiments are conducted on the VULCAN Engineering Materials Diffractometer at the Spallation Neutron Source, Oak Ridge National Laboratory, over a temperature range from room temperature to 1200 °C under vacuum. Pure vanadium exhibited distinct Bragg peaks across all temperatures, with its diffraction behavior influenced by both sample orientation and temperature. As the temperature increased, the diffraction peaks shifted to larger d-spacings and decreased in intensity, while spectral deviation near d ≈ 2.8 Å exceeded 10% at 1200 °C. In contrast, the V–Nb alloy produced a nearly featureless spectrum over the full d-spacing range, confirming near-complete cancellation of coherent scattering over the wide temperature range. Its spectra were insensitive to sample orientation, temperature, and microstructural evolution, with spectral deviation around d ≈ 2.8 Å exceeded 5% at 1200 °C. In conclusion, these results demonstrate that the V–Nb null-matrix alloy provides a thermally stable, efficient, and reliable normalization standard for time-of-flight diffractometers or other instrument where it is needed, enabling reduced data acquisition time and improved data quality in high-temperature neutron diffraction experiments.

Alloys↗

Real Time implementation of Artificial Intelligence compression algorithm for High-Speed Streaming Readout signals

The new generation of high-energy physics experiments plans to acquire data in streaming mode. With this approach, it is possible to access the information of the whole detector (organized in time slices) for optimal and lossless triggering of data acquisitions. With this approach, data rates, especially in large detectors, are often very high, and the network is likely to be the bottleneck for the entire Streaming Read Out system. The aim of this work is to study the implementation of a lossy compression algorithm based on Artificial Intelligence: an Autoencoder. With Machine Learning it is possible to achieve a high compression ratio and fast inference time with only a small degradation of the signals, almost negligible for the specific application. This work explores different configurations of the Autoencoder and the implementation on different hardware. Different Autoencoder configurations are explored to find the best trade-off between compression ratio and reconstruction loss, both for signals and energy spectrum. Different hardware implementations are also explored to find the best platform to achieve real-time performance for the specific application.

Rossi, Fabio (ORCID:0009000385713885)↗

Development of autonomous gamma dose logger for environmental monitoring

Continuous monitoring and archiving of background radiation levels in and around the nuclear installation is essential and the data would be of immense use during analysis of any untoward incidents. A portable Geiger Muller detector based autonomous gamma dose logger (AGDL) for environmental monitoring is indigenously designed and developed. The system operations are controlled by microcontroller (AT89S52) and the main features of the system are software data acquisition, real time LCD display of radiation level, data archiving at removable compact flash card. The complete system operates on 12 V battery backed up by solar panel and hence the system is totally portable and ideal for field use. The system has been calibrated with Co-60 source (8.1 MBq) at various source-detector distances. The system is field tested and performance evaluation is carried out. This paper covers the design considerations of the hardware, software architecture of the system along with details of the front-end operation of the autonomous gamma dose logger and the data file formats. The data gathered during field testing and inter comparison with GammaTRACER are also presented in the paper. AGDL has shown excellent correlation with energy fluence monitor tuned to identify {sup 41}Ar, proving its utility for real-time plume tracking and source term estimation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CoGeNT: A Search for Low-Mass Dark Matter using p-type Point Contact Germanium Detectors

CoGeNT employs p-type point-contact (PPC) germanium detectors to search for Weakly In- teracting Massive Particles (WIMPs). By virtue of its low energy threshold and ability to reject surface backgrounds, this type of device allows an emphasis on low-mass dark matter candidates (m* * 10 GeV/c2). We report on the characteristics of the PPC detector presently taking data at the Soudan Underground Laboratory, elaborating on aspects of shielding, data acquisition, instru- mental stability, data analysis, and background estimation. A detailed background model is used to investigate the low energy excess of events previously reported, and to assess the possibility of temporal modulations in the low-energy event rate. We conclude that the technique is ideally suited to search for the annual modulation signature expected from dark matter particle interactions in the region of WIMP mass and coupling favored by the DAMA/LIBRA claim.

Aalseth, Craig E.↗

Grid Edge Waveform Analytics Framework for Event Detection and Classification

This paper provides a grid edge waveform analytics framework for power system event detection and classification in the local as well as in the wide area. This framework overviews data excellence for event detection and classification. The data excellence describes the data acquisition process and requirements, data processing, data quality, and data integrity. Power system event detection in the local area based on different features such as energy-based, cyclostationary approach, template matching, and wavelet transform are also discussed. Furthermore, local area event detection and classification using approaches such as statistical, signal processing, artificial intelligence, and hybrid are also discussed. Moreover, an overview of wide-area event detection and classification along with several other aspects such as wide-area events, wide-area event detection approaches, event location and system performance, event pattern recognition, inter-area oscillation, and wide-area frequency response under variable deployment of inverter-based resources are also provided. The proposed framework is the first step toward the goal of developing appropriate tools and methodologies to detect and classify local as well as wide-area events using waveform analytics. The appropriate event detection and classification framework development is especially important now as more and more grid edge devices with communication capabilities are being deployed in the modern power grid than ever before.

Bhusal, Narayan↗

A Prognostics and Health Management Framework for Wind

Operation and maintenance costs are a major driver for levelized cost of energy of wind power plants and can be reduced through optimized operation and maintenance practices accomplishable by various prognostics and health management (PHM) technologies. In recent years, the wind industry has become more open to adopting PHM solutions, especially those focusing on diagnostics. However, prognostics activities are, in general, still at the research and development stage. On the other hand, the industry has a request to estimate a component's remaining useful life (RUL) when it has faulted, and this is a key output of prognostics. Systematically presenting PHM technologies to the wind industry by highlighting the RUL prediction need potentially helps speed up its acceptance and provides more benefits from PHM to the industry. In this paper, we introduce a PHM for wind framework. It highlights specifics unique to wind turbines and features integration of data and physics domain information and models. The output of the framework focuses on RUL prediction. To demonstrate its application, a data domain method for wind turbine gearbox fault diagnostics is presented. It uses supervisory control and data acquisition system time series data, normalizes gearbox temperature measurements with reference to environmental temperature and turbine power, and leverages big data analytics and machine-learning techniques to make the model scalable and the diagnostics process automatic. Another physics-domain modeling method for RUL prediction of wind turbine gearbox high-speed-stage bearings failed by axial cracks is also discussed. Bearing axial cracking has been shown to be the prevalent wind turbine gearbox failure mode experienced in the field and is different from rolling contact fatigue, which is targeted during the bearing design stage. The method uses probability of failure as a component reliability assessment and RUL prediction metric, which can be expanded to other drivetrain components or failure modes. The presented PHM for wind framework is generic and applicable to both land-based and offshore wind turbines.

17 WIND ENERGY↗

WE-FG-207B-03: Multi-Energy CT Reconstruction with Spatial Spectral Nonlocal Means Regularization

Purpose: Multi-energy computed tomography (MECT) is an emerging application in medical imaging due to its ability of material differentiation and potential for molecular imaging. In MECT, image correlations at different spatial and channels exist. It is desirable to incorporate these correlations in reconstruction to improve image quality. For this purpose, this study proposes a MECT reconstruction technique that employes spatial spectral non-local means (ssNLM) regularization. Methods: We consider a kVp-switching scanning method in which source energy is rapidly switched during data acquisition. For each energy channel, this yields projection data acquired at a number of angles, whereas projection angles among channels are different. We formulate the reconstruction task as an optimziation problem. A least square term enfores data fidelity. A ssNLM term is used as regularization to encourage similarities among image patches at different spatial locations and channels. When comparing image patches at different channels, intensity difference were corrected by a transformation estimated via histogram equalization during the reconstruction process. Results: We tested our method in a simulation study with a NCAT phantom and an experimental study with a Gammex phantom. For comparison purpose, we also performed reconstructions using conjugate-gradient least square (CGLS) method and conventional NLM method that only considers spatial correlation in an image. ssNLM is able to better suppress streak artifacts. The streaks are along different projection directions in images at different channels. ssNLM discourages this dissimilarity and hence removes them. True image structures are preserved in this process. Measurements in regions of interests yield 1.1 to 3.2 and 1.5 to 1.8 times higher contrast to noise ratio than the NLM approach. Improvements over CGLS is even more profound due to lack of regularization in the CGLS method and hence amplified noise. Conclusion: The proposed ssNLM method for kVp-switching MECT reconstruction can achieve high quality MECT images.

60 APPLIED LIFE SCIENCES↗

IDC Re-Engineering Phase 2 Iteration E2 Use Case Realizations

This architecturally significant use case describes how the System acquires meteorological data to build atmospheric models used in automatic and interactive processing of infrasound data. The System requests the latest available high-resolution global meteorological data from external data centers and puts it into the correct formats for generation of infrasound propagation models. The system moves the meteorological data from Data Acquisition Partition to the Data Processing Partition and stores the meteorological data. The System builds a new atmospheric model based on the meteorological data. This use case is architecturally significant because it describes acquiring meteorological data from various sources and creating dynamic atmospheric transmission model to support the prediction of infrasonic signal detection

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

The development, testing and characterisation of a straw tracking detector and readout system for the Fermilab muon g-2 experiment

The anomalous magnetic moments of leptons can be both measured and theoretically predicted with high precision, and as such provide stringent tests of the Standard Model (SM) of particle physics. The anomalous magnetic moment of the muon, $a_\mu$, in particular offers sensitivity to new physics within the reach of current experiments. The current world’s best measurement of aμ made at the Brookhaven National Laboratory (BNL) deviates from the SM prediction by over 3σ, providing a tantalising but inconclusive hint that contributions from new physics may be present. A new $a_\mu$ experiment is currently under construction at the Fermi National Accelerator Laboratory (Fermilab), known as the Fermilab muon g-2 experiment. Due to commence in 2017, this new experiment is expected to improve the experimental measurement precision of $a_\mu$ by a factor of 4, and is seeking to confirm or reject the current discrepancy. The experiment, like its BNL predecessor, will measure the precession of the $\mu^{+}$ spin in a magnetic storage-ring. This new experiment has three straw tracking detectors used to measure the beam profile of the stored $\mu^{+}$, as well as other dynamic properties of the beam. This thesis describes the design of these detectors, and the data acquisition system and subsequent data processing systems that have been developed to read them out and make their data available for physics analysis. The performance of the straw trackers and the readout systems at a number of beam tests and test stands is presented, in addition to Monte-Carlo simulations of the trackers in the final experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

IDC Re-Engineering Phase 2 Iteration E2 Use Case Realizations

This architecturally significant use case describes how the System acquires meteorological data to build atmospheric models used in automatic and interactive processing of infrasound data. The System requests the latest available high-resolution global meteorological data from external data centers and puts it into the correct formats for generation of infrasound propagation models. The system moves the meteorological data from Data Acquisition Partition to the Data Processing Partition and stores the meteorological data. The System builds a new atmospheric model based on the meteorological data. This use case is architecturally significant because it describes acquiring meteorological data from various sources and creating dynamic atmospheric transmission model to support the prediction of infrasonic signal detections.

97 MATHEMATICS AND COMPUTING↗

HRMT-67 Radiate II Material Studies

This poster covers the current status of the HRMT-67 experiment conducted in August of 2025. The poster contains information on the scientific motivation, experimental assembly, data acquisition methods including some data that was recorded as reference, and the next steps for the experiment concerning Post Irradiation Examination (PIE) work.

Peterson, Q. [Fermilab]↗

SpecFIDLER User Manual: Software Version 2.4.0

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.5.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SpecFIDLER User Manual (Software V.2.6.0)

The Spectroscopic Field Instrument for Detection of Low Energy Radiation (SpecFIDLER) allows response teams to detect and quantify plutonium contamination on the ground. Notional scenarios include dispersion from a weapon accident, or the launch failure of a space probe containing a radioisotope thermoelectric generator. Unlike other instruments, the thin-window sodium iodide detector is sensitive to the low-energy gamma rays emitted by plutonium isotopes. The system supports both mobile survey as well as stationary sampling. This manual provides information about installing, maintaining, and troubleshooting the SpecFIDLER. The scope of this document includes the physical hardware, software for data acquisition, and algorithms for data analysis. Recent changes to the software and algorithms aim to streamline the operation of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗