Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DUCTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Finite difference solutions to shocked acoustic waves

The MacCormack, Lambda and split flux finite differencing schemes are used to solve a one dimensional acoustics problem. Two duct configurations were considered, a uniform duct and a converging-diverging nozzle. Asymptotic solutions for these two ducts are compared with the numerical solutions. When the acoustic amplitude and frequency are sufficiently high the acoustic signal shocks. This condition leads to a deterioration of the numerical solutions since viscous terms may be required if the shock is to be resolved. A continuous uniform duct solution is considered to demonstrate how the viscous terms modify the solution. These results are then compared with a shocked solution with and without viscous terms. Generally it is found that the most accurate solutions are those obtained using the minimum possible viscosity coefficients. All of the schemes considered give results accurate enough for acoustic power calculations with no one scheme performing significantly better than the others.

Walkington, N. J.↗

Acoustic loading in planar networks

The acoustic loading in a complex planar network of ducts is determined by a method in which Green function surface elements are used. The network consists of straight ducts, elbows and branched ducts. A transfer matrix technique is developed in which each duct is treated separately and the matrix of the influence coefficients is transformed to tri-diagonal form allowing efficient inversion.

El-Raheb, M.↗

Gas flow environment and heat transfer nonrotating 3D program

A complete set of benchmark quality data for the flow and heat transfer within a large rectangular turning duct is provided. These data are to be used to evaluate, and verify, three-dimensional internal viscous flow models and computational codes. The analytical contract objective is to select a computational code and define the capabilities of this code to predict the experimental results obtained. Details of the proper code operation will be defined and improvements to the code modeling capabilities will be formulated. Internal flow in a large rectangular cross-sectioned 90 deg. bend turning duct was studied. The duct construction was designed to allow detailed measurements to be made for the following three duct wall conditions: (1) an isothermal wall with isothermal flow; (2) an adiabatic wall with convective heat transfer by mixing between an unheated surrounding flow; and (3) an isothermal wall with heat transfer from a uniformly hot inlet flow.

Schulz, R. J.↗

Vortex shedding flowmeters for liquids at high flow velocities

A number of vortex shedding flowmeter designs for flow measurements in liquid oxygen ducts on the space shuttle main engines have been tested in a high head water flow test facility. The results have shown that a vortex shedding element or vane spanning the duct can give a linear response to an average flow velocity of 46 m/s (150 ft/s) in a 1 1/2 inch nominal (41 mm actual) diameter duct while a vane partially spanning the duct can give a linear response to velocities exceeding 55 m/s (180 ft/s). The maximum pressure drops across the flow sensing elements extrapolate to less than 0.7 MPa (100 psi) at 56 m/s (184 ft/s) for liquid oxygen. The test results indicate that the vanes probably cannot be scaled up with pipe size, at least not linearly.

Siegwarth, J. D.↗

Whistler-triggered VLF noise bursts observed on the DE-1 satellite and simultaneously at Antarctic ground stations

Simultaneous observations of whistler-triggered very low-frequency noise bursts on the ground at Anarctic stations, Halley and Siple, and on the high-altitude satellite DE-1 are reported. Results of a case study from June 25, 1982 in which the satellite data were recorded near 25 deg south magnetic latitude and the L = 4.7 magnetic shell, are presented. Analysis indicates that the chorus bursts that are triggered in whistler ducts travel downwards in the ducts to low altitudes in the ionosphere, and that propagation to DE-1 is by upward reflection into a nonducted mode. A means of estimating the propagation characteristics of the wave bursts is provided by comparisons of nonducted signals from the Siple transmitter and discrete periodic emissions. The ducted-nonducted mode conversion process is a mechanism for the large-scale spreading into the magnetosphere of coherent whistler-mode wave energy which is generated, amplified, or triggered in small localized ducts. The DE-1 data show that a strong interaction exists between whistler-triggered noise bursts and prevailing hiss levels.

Smith, A. J.↗

Application of Gr/PMR-15 to commercial aircraft

Following from early experience with polyimides on the SST program and Shuttle aft flap studies the Boeing Company is now working on collaborative programs with its principal nacelle suppliers to pursue the development of Gr/PMR-15 nacelle components. Two programs are currently in effect. The first program is directed specifically towards the flight test and service evaluation at the earliest possible date of a 747 nacelle core cowl structure. The second program seeks to firmly establish the producibility and cost of a 757 thrust reverser C duct in a production environment. The near term objectives of these programs include: (1) the comparison of estimated cost and weight of Gr/PMR-15 versus metal structure, (2) the engine test of representative composite structure, (3) the preliminary design and analysis of the C duct structure, and (4) the preparation of cost data and time schedules for the development and producibility program. In addition to powerplant structure, the propulsion ducting system has shown to be a strong candidate for Gr/PMR-15 application. Currently, the Boeing 747 Organization is evaluating the use of PMR-15 matrix composites to replace nearly 800 lbs of titanium ducting per airplane.

Postlewaite, J.↗

Laboratory experiments on active suppression of advanced turboprop noise

The noise generated by supersonic tip speed propellers may be a cabin environment problem for future propeller-driven airplanes. Active suppression from speakers inside the airplane cabin has been proposed for canceling out this noise. The potential of active suppression of advanced turboprop noise was tested by using speakers in a rectangular duct. Experiments were first performed with sine wave signals. The results compared well with the ideal cancellation curve of noise as a function of phase angle. Recorded noise signals from subsonic and supersonic tip speed propellers were than used in the duct to deterthe potential for canceling their noise. The subsonic propeller data showed significant cancellations but less than those obtained with the sine wave. The blade-passing-tone cancellation curve for the supersonic propeller was very similar to the subsonic curve, indicating that it is potentially just as easy to cancel supersonic as subsonic propeller blade-passing-tone noise. Propeller duct data from a recorded propeller source and spatial data taken on a propeller-drive airplane showed generally good agreement when compared versus phase angle. This agreement, combined with the similarity of the subsonic and supersonic duct propeller data, indicates that the area of cancellation for advanced supersonic propellers will be similar to that measured on the airplane. Since the area of cancellation on the airplane was small, a method for improving the active noise suppression by using outside speakers is discussed.

Dittmar, J. H.↗

DE-1/Siple VLF wave-injection experiments

Results of Siple/DE-1 VLF wave-injection/reception experiments indicate that the injected signals, while propagating in the magnetosphere in the non-ducted mode, are on occasion amplified, generate sidebands and trigger VLF emissions. The propagation paths include direct non-ducted paths as well as reflected modes involving propagation initially in a 'duct' followed by a reflected non-ducted path up to the satellite. Calibrated measurements of the wave magnetic and electric intensities are used to estimate the local refractive index.

Inan, U. S.↗

Numerical analysis of flow in the hot gas manifold of the Space Shuttle main engine

This paper presents a numerical model and results of analyses carried out to characterize the flow through the two duct configuration of the Hot Gas Manifold of the Space Shuttle Main Engine. Three dimensional computations have been performed for a half-scale air test model using a nonorthogonal body-fitted coordinate system. The calculation domain is extended from the inlet of the turnaround duct to the exit of the transfer duct. Three test cases, one for laminar flow and two for turbulent flow, have been considered. For turbulent flows, constant eddy viscosity and the k-epsilon model of turbulence were employed. As expected, laminar flow calculation predicts much larger pressure drop than turbulent flow cases. The turbulent flow results are in good agreement with the available flow-visualization data. This study and experimental data indicate that the two-transfer duct design will significantly improve the flow distribution in the Hot Gas Manifold and thereby enhance the overall performance of the SSME.

Owens, S. F.↗

Effect of a wind tunnel on the acoustic field from various aeroacoustic sources

The effects of the walls of an enclosed test section wind tunnel on measurements of sound fields from various sources has been studied. The acoustic field from a known source in a wind tunnel has been modeled as an infinitely long duct with constant cross section. The model was solved with a numerical panel technique in a control volume near the source, and matched to an outer analytic solution. Several sample problems were studied in a rectangular duct with and without flow. The results indicate that the presence of the duct affects the acoustic field, and that small changes in the product of duct cross dimensions and the source wave number can change the acoustic field significantly. It is also shown that, for low-frequency helicopter rotor harmonic noise, measured in typical wind tunnel rotor tests, the sound levels beyond one rotor diameter from the hub are unreliable indications of the free-field sound levels.

Mosher, M.↗

PTA test bed aircraft engine inlet model test report, revised

The inlet duct test for the Propfan Testbed Assessment (PTA) program was completed in November 1984. The basic test duct was designed using the Lockheed QUADPAN computational code. Test objectives were to experimentally evaluate, modify as required, and eventually verify satisfactory performance as well as duct/engine compatibility. Measured total pressure recovery for the basic duct was 0.993 with no swirl and 0.989 for inflow with a 30 degree simulated swirl angle. This compared to a predicted recovery of 0.979 with no swirl. Measured circumferential distortion with swirl, based on a least-square curve fit of the data, was 0.204 compared to a maximum allowable value of 0.550. Other measured distortion parameters did as well or better relative to their respective maximum allowable values. The basic duct configuration with no refinements is recommended for the PTA inlet as a minimum cost installation.

Hancock, J. P.↗

Vortex shedding flow meter performance at high flow velocities

In some of the ducts of the Space Shuttle Main Engine (SSME), the maximum liquid oxygen flow velocities approach 10 times those at which liquid flow measurements are normally made. The hydrogen gas flow velocities in other ducts exceed the maximum for gas flow measurement by more than a factor of 3. The results presented here show from water flow tests that vortex shedding flow meters of the appropriate design can measure water flow to velocities in excess of 55 m/s, which is a Reynolds number of about 2 million. Air flow tests have shown that the same meter can measure flow to a Reynolds number of at least 22 million. Vortex shedding meters were installed in two of the SSME ducts and tested with water flow. Narrow spectrum lines were obtained and the meter output frequencies were proportional to flow to + or - 0.5% or better over the test range with no flow conditioning, even though the ducts had multiple bends preceeding the meter location. Meters with the shedding elements only partially spanning the pipe and some meters with ring shaped shedding elements were also tested.

Siegwarth, J. D.↗

Impulsively generated fast coronal pulsations

Rapid oscillations in the corona are discussed from a theoretical standpoint, developing some previous work on ducted, fast magnetoacoustic waves in an inhomogeneous medium. In the theory, impulsively (e.g., flare) generated mhd (magnetohydrodynamic) waves are ducted by regions of low Alfven speed (high density) such as coronal loops. Wave propagation in such ducts is strongly dispersive and closely akin to the behavior of Love waves in seismology, Pekeris waves in oceanography and guided waves in fiber optics. Such flare-generated magnetoacoustic waves possess distinctive temporal signatures consisting of periodic, quasi-periodic and decay phases. The quasi-periodic phase possesses the strongest amplitudes and the shortest time scales. Time scales are typically of the order of a second for inhomogeneities (coronal loop width) of 1000 km and Alfven speeds of 1000/kms, and pulse duration times are of tens of seconds. Quasi-periodic signatures have been observed in radio wavelengths for over a decade and more recently by SMM. It is hoped that the theoretical ideas outlined may be successfully related to these observations and thus aid the interpretation of oscillatory signatures recorded by SMM. Such signatures may also provide a diagnostic of coronal conditions. New aspects of the ducted mhd waves, for example their behavior in smoothly varying as opposed to tube-like inhomogeneities, are currently under investigation. The theory is not restricted to loops but applied equally to open field regions.

Edwin, P. M.↗

Mesoscale waves as a probe of Jupiter's deep atmosphere

Search of the Voyager images of Jupiter reveals a class of mesoscale waves occurring near the extrema of the zonal velocity profile between latitudes 30 deg S and 30 deg N. The average horizontal wavelength is 300 km, compared to an atmospheric scale height of 20 km; the standard deviation about the mean is only 20 percent. The alignment of most wave trains is nearly zonal, i.e., wave crests are north-south. A typical wave packet is 20 wave crests in length and 1300 km wide. Modeling shows that the waves propagate in a duct below the ammonia condensation level (the visible clouds). For selection of one dominant mode, the Richardson number in the duct must be of order unity; this is the first quantitative determination that has ever been made of the stability of Jupiter's atmosphere below its clouds. The duct is topped by a trapping layer, the ammonia clouds, where the Richardson number is less than 0.25. Meridional trapping of the wave packets is due to the shear in the zonal wind. It is speculated that the period of the waves is diurnal and that they do not propagate poleward of latitudes + or - 30 deg because the Coriolis frequency exceeds the duct Brunt frequency. The waves might be excited by diurnal variations of moist convective activity in the ammonia clouds.

Flasar, F. M.↗

Acoustic wave propagation in heterogeneous structures including experimental validation

A finite element model was developed to solve for the acoustic pressure and energy fields in a heterogeneous suppressor. The derivations from the governing equations assumed that the material properties could vary with position resulting in a heterogeneous variable property two-dimensional wave equation. This eliminated the necessity of finding the boundary conditions between different materials. For a two media region consisting of part air and part bulk absorber, a model was used to describe the bulk absorber properties in two directions. Complex metallic structures inside the air duct are simulated by simply changing element properties from air to the structural material in a pattern to describe the desired shapes. To verify the numerical theory, experiments were conducted without flow in a rectangular duct with a single folded cavity mounted above the duct and absorbing material mounted inside a cavity. Changes in a nearly plane wave sound field were measured on the wall opposite the absorbing cavity. Fairly good agreement was found in the standing wave pattern upstream of the absorber and in the decay of pressure level opposite the absorber, as a function of distance along the duct. The finite element model provides a convenient method for evaluating the acoustic properties of bulk absorbers.

Baumeister, Kenneth J.↗

Acoustic wave propagation in heterogeneous structures including experimental validation

A finite element model was developed to solve for the acoustic pressure and energy fields in a heterogeneous suppressor. The derivations from the governing equations assumed that the material properties could vary with position resulting in a heterogeneous variable property two-dimensional wave equation. This eliminated the necessity of finding the boundary conditions between different materials. For a two-media region consisting of part air and part bulk absorber, a model was used to describe the bulk absorber properties in two directions. Complex metallic structures inside the air duct are simulated by simply changing element properties from air to the structural material in a pattern to describe the desired shapes. To verify the numerical theory, experiments were conducted without flow in a rectangular duct with a single folded cavity mounted above the duct and absorbing material mounted inside a cavity. Changes in a nearly plane wave sound field were measured on the wall opposite the absorbing cavity. Fairly good agreement was found in the standing wave pattern upstream of the absorber and in the decay of pressure level opposite the absorber, as a function of distance along the duct. The finite element model provides a convenient method for evaluating the acoustic properties of bulk absorbers.

Baumeister, Kenneth J.↗

Positioning X-Ray Film By Balloon

Film rolled around deflated balloon before being inserted in duct. Clamped at end of segmented flexible cable and fed with balloon into duct to predetermined point where inspection made, as indicated by length of cable paid out. Inflated balloon holds x-ray film against inside wall of duct for radiographic inspection. Ensures film positioned in contact with welded joint far along duct from opening through which inserted, so clear x-ray image of joint obtained.

Windbiel, Frederich↗

Measurement of terms and parameters in turbulent models

Experimental measurements of the mean and turbulent velocity field in a water flow, turn-around-duct is documented. The small radius of curvature duct experiments were made over a range of Reynolds numbers (based on a duct height of 10 cm) from 70,000 to 500,000. For this particular channel, the flow is dominated by the inertia forces. Use of the local bulk velocity to non-dimensionalize the local velocity was found to limit Reynolds number effects to the regions very close to the wall. Only secondary effects on the flow field were observed when the inlet or exit boundary conditions were altered. The flow over the central two-thirds of the channel was two-dimensional. Mean tangetial and radial velocities, streamlines, pressure distributions, surface shear stress; tangential, radial and lateral turbulent velocities and the Reynolds turbulent shear values are tabulated in other reports. It is evident from the experimental study that a complex numerical modeling technique must be developed to predict the flow in the turn-around-duct. The model must be able to predict relaminarization along the inner-convex-wall. It must also allow for the major increase in turbulence produced by the outer-concave-wall.

Sandborn, Virgil A.↗