Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CONDENSATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Dipolar Bose-Hubbard model

We study a simple model of interacting bosons on a d-dimensional cubic lattice whose dynamics conserves both total boson number and total boson dipole moment. This model provides a simple framework in which several remarkable consequences of dipole conservation can be explored. As a function of chemical potential and hopping strength, the model can be tuned between gapped Mott insulating phases and various types of gapless condensates. The condensed phase realized at large hopping strengths, which we dub a Bose-Einstein insulator, is particularly interesting: despite having a Bose condensate, it is insulating, and despite being an insulator, it is compressible.

36 MATERIALS SCIENCE↗

Finite-momentum instability of a dynamical axion insulator

Due to the chiral anomaly, Weyl semimetals can exhibit a signature topological magnetoelectric response known as an axion term which is determined by the microscopic band structure. In the presence of strong interactions Weyl fermions may form a chiral condensate, with the intrinsic dynamics and fluctuations of the associated condensate phase producing a dynamical contribution to the axion response. Here we show that an imbalance in the density of right- and left-handed electrons drives an instability of the chiral condensate towards finite momentum and leads to strong fluctuations in the axion response. We derive a long-wavelength theory of Lifschitz type governing the dynamics of the Goldstone mode and use this to characterize its associated spatial fluctuations, which manifest as an inhomogeneous anomalous Hall effect. In conclusion, we show that these fluctuations produce signatures in inelastic light-scattering experiments across a broad spectrum of frequencies, and can be used to determine the structure factor for the axionic collective mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance Evaluation of Liquid-Cooled Open Stand-Alone Refrigerated Cases

This project is part of a joint effort between Commonwealth Edison Company (ComEd) and the National Renewable Energy Laboratory (NREL) to evaluate the energy and demand savings potential of emerging efficient buildings technologies. This project quantifies the energy efficiency benefits from retrofitting an air-cooled, constant-speed compression, self-contained medium-temperature open-vertical display case with a high efficiency water-cooled condensing unit. In addition to a water-cooled heat rejection mechanism, the high-efficiency condensing unit utilizes a variable-speed compressor, electronic expansion valve and advanced controls system. The focus of this project, however, was mainly on capturing the energy savings potentials of the water-cooled condenser, variable-speed compression and electronic expansion valve, and not on the advanced controls. The results of this evaluation will be considered by ComEd and CLEAResult for future energy efficiency rebate offerings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantum criticality and topology in non-equilibrium systems

A key goal of condensed matter physics research is to identify new phases of matter, and to understand the universal features of the phase transitions between them. In the past decade, physicists have uncovered a wealth of new phases with interesting surface properties, exemplified by the theoretical prediction and subsequent experimental discovery of topological insulators and superconductors. Traditional condensed matter systems are usually in a thermal equilibrium state and typically at very low temperature. Very recently, experimental advances have sparked interest in the non-equilibrium setting. Non-equilibrium systems can host new phases and phenomena with no equilibrium counterpart, and could also enable robust ways to build quantum memory devices to store and manipulate quantum information in a coherent manner. These phases and phenomena are inherently “dynamical”: they are described not by changes in the arrangement or structure of the constituent particles, but instead marked by sharp distinctions in how the particles move and exchange energy or quantum information. The discovery of robust non-equilibrium phases raises many fundamental questions: Can we develop a systematic theory of states of matter and of dynamical transitions between such states? How can such states be realized and probed experimentally? The main goal of this project was to explore the emergence of topological phases and quantum criticality (two cornerstones of modern condensed matter physics in equilibrium) in such non-equilibrium quantum systems. Specific goals included (1) using tensor networks to efficiently represent non-equilibrium states of matter and their phase transitions; (2) studying and designing new probes for periodically driven systems; and (3) developing analytic and numerical tools to analyze non-equilibrium topological phase transitions. Advances in these directions were achieved using novel techniques appropriate to study the non-equilibrium dynamics in many-body quantum systems combining strong interactions and randomness. Taken together, these results provide a new conceptual framework for understanding the emergence of quantum critical and topological properties in quantum systems far from thermal equilibrium.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron Correlation and High-Temperature Superconductivity

Strong electron correlation plays a central role in the high-temperature superconductivity (HTSC) of cuprates. However, to date, research has focused only on its role in spin dynamics and related effects, even though it is becoming increasingly clear that spin alone may not be sufficient to create HTSC. Here, we discuss a possible role of electron correlation in the Bose–Einstein condensation (BEC) of Cooper pairs. Recently, we succeeded in observing dynamic electron correlation via inelastic X-ray scattering through results presented in real space. We discovered that electron correlations are strongly modified in the plasmon, proving that electron dynamics significantly affect electron correlation. Earlier, we found that in 4 He, the atom–atom distance in the BE condensate is 10% longer than that in the non-condensate. These results suggest the possibility that the reduction in electron-repulsion energy upon BEC is driving T c to high values. Thus, electron correlation itself could be the origin of the HTSC phenomenon.

Bose–Einstein condensation↗

Invisible QCD as Dark Energy

We account for the late time acceleration of the Universe by extending the Quantum Chromodynamics (QCD) color to a SU(3) invisible sector (IQCD). If the Invisible Chiral symmetry is broken in the early universe, a condensate of dark pions (dpions) and dark gluons (dgluons) forms. The condensate naturally forms due to strong dynamics similar to the Nambu–Jona-Lasinio mechanism. As the Universe evolves from early times to present times the interaction energy between the dgluon and dpion condensate dominates with a negative pressure equation of state and causes late time acceleration. We conclude with a stability analysis of the coupled perturbations of the dark pions and dark gluons.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of Cryogenic Propellant Liquefaction Rates in Cooled Constant-Wall-TemperatureTanks

NASA has been focused on developing technology that would allow the production of cryogenic propellants on the Lunar and Martian surfaces. Utilizing Lunar/Martian resources, the produced gaseous propellants must first be liquefied and stored prior to use on the Moon or Mars ascent vehicle. Liquefaction of cryogenic propellants is a necessary technical development to enable NASA’s future spaceflight goals. This paper presents an overview of a proposed model for a propellant liquefaction system, and the effect of tank wall temperature and the ullage pressure control band on cryogenic propellant liquefaction rates. The propellant system was assumed to be a receiver of a gas from an In-Situ Resource Utilization (ISRU) harvester and condensed the gas by cooling the tank walls. First, the heat transfer principles pertinent to condensation are summarized, followed by an overview of the model which performed the analysis, including a summary of the Fortran algorithm implementation. The sensitivity of the condensation rate relative to varying tank wall temperatures is also discussed.

cryogenics↗

Analysis of Cryogenic Propellant Liquefaction Rates in Cooled Constant-Wall-Temperature Tanks

NASA has been focused on developing technology that would allow the production of cryogenic propellants on the Lunar and Martian surfaces. Utilizing Lunar/Martian resources, the produced gaseous propellants must first be liquefied and stored prior to use on the Moon or Mars ascent vehicle. Liquefaction of cryogenic propellant is a necessary technical development to enable NASA’s future spaceflight goals. This paper presents an overview of the effect of spacecraft propellant system parameters on cryogenic propellant liquefaction rates. The propellant system was assumed to be a receiver of a gas from an In-Situ Resource Utilization (ISRU) harvester and condensed the gas by cooling the tank walls. First, the general thermodynamic principles pertinent to condensation are summarized, followed by an overview of the model which performed the analysis, including a summary of the Fortran implementation. Comparisons between the model results and test data are discussed, as well as sensitivity of the condensation rate to various parameters.

cryogenics↗

Analysis of Cryogenic Propellant Liquefaction Rates in Cooled Constant-Wall-TemperatureTanks

NASA has been focused on developing technology that would allow the production of cryogenic propellants on the Lunar and Martian surfaces. Utilizing Lunar/Martian resources, the produced gaseous propellants must first be liquefied and stored prior to use on the Moon or Mars ascent vehicle. Liquefaction of cryogenic propellant is a necessary technical development to enable NASA’s future spaceflight goals. This paper presents an overview of the effect of spacecraft propellant system parameters on cryogenic propellant liquefaction rates. The propellant system was assumed to be a receiver of a gas from an In-Situ Resource Utilization (ISRU) harvester and condensed the gas by cooling the tank walls. First, the general thermodynamic principles pertinent to condensation are summarized, followed by an overview of the model which performed the analysis, including a summary of the Fortran implementation. Comparisons between the model results and test data are discussed, as well as sensitivity of the condensation rate to various parameters.

cryogenics↗

Two-Dimensional Network Flow Modeling of No-Vent Tank Filling of A Cryogenic Tank With Thermo-Dynamic Vent System Assisted Injector

A finite volume-based network flow modeling tool, Generalized Fluid System Simulation Program (GFSSP), was used to simulate the no-vent filling of a cryogenic tank with a thermodynamic vent system assisted injector. The tank was discretized into nodes in the radial and axial directions to calculate two-dimensional axisymmetric flow with heat transfer between the solid wall and fluid. The nodes are connected by branches where momentum equations are solved to calculate the flowrates. The mass and energy conservation equations and the equation of state are solved to calculate pressure, temperature, and resident mass at the nodes. The energy conservation equations at the solid nodes were solved to calculate the temperature of the solid wall. The system of equations was solved by a combination of successive substitution and simultaneous Newton-Raphson method. The numerical model accounts for a) different regimes of pool boiling heat transfer, b) condensation of vapor around the spray droplets, c) condensation of vapor at the interface of the cooled injector and ullage, and d) condensation at the liquid-vapor interphase. The numerical predictions of tank pressure, filling rate, and wall temperatures were compared with the test data. The paper also presents the effect of nodal discretization by comparing the results of the 1D and 2D models and examines the effect of the droplet diameter on tank filling.

Nodal Model↗

Two-Dimensional Network Flow Modeling of No-Vent Tank Filling of A Cryogenic Tank With Thermo-Dynamic Vent System Assisted Injector

A finite volume-based network flow modeling tool, Generalized Fluid System Simulation Program (GFSSP), was used to simulate the no-vent filling of a cryogenic tank with a thermodynamic vent system assisted injector. The tank was discretized into nodes in the radial and axial directions to calculate two-dimensional axisymmetric flow with heat transfer between the solid wall and fluid. The nodes are connected by branches where momentum equations are solved to calculate the flowrates. The mass and energy conservation equations and the equation of state are solved to calculate pressure, temperature, and resident mass at the nodes. The energy conservation equations at the solid nodes were solved to calculate the temperature of the solid wall. The system of equations was solved by a combination of successive substitution and simultaneous Newton-Raphson method. The numerical model accounts for a) different regimes of pool boiling heat transfer, b) condensation of vapor around the spray droplets, c) condensation of vapor at the interface of the cooled injector and ullage, and d) condensation at the liquid-vapor interphase. The numerical predictions of tank pressure, filling rate, and wall temperatures were compared with the test data. The paper also presents the effect of nodal discretization by comparing the results of the 1D and 2D models and examines the effect of the droplet diameter on tank filling.

Nodal Model↗

CFD-Assisted Nodal Modeling of Sloshing in a Cryogenic Propellant Tank

During autogenous pressurization, tank sloshing causes a significant increase in pressurant consumption to maintain constant ullage pressure during draining of the tank. This increase in pressurant consumption is caused by a significant increase in condensation at the liquid-vapor interface. Sloshing strongly affects the liquid side heat transfer coefficient and thereby the condensation rate. Traditionally, sloshing is modeled by CFD code using the VOF (Volume of Fluid) method to track the liquid vapor interface during sloshing. CFD calculations require a very fine grid to accurately compute the heat and mass transfer at the interface. Therefore, computations are time consuming and prohibit performing many parametric studies often needed during the design of a new system. This paper describes an alternative approach by developing a CFD-assisted nodal model to predict system parameters more economically with reasonable accuracy. In this approach, a multi-node model of tank pressurization was developed using GFSSP. A multi-node model was needed to account for stratification. The model computes heat and mass transfer at the interface to calculate the condensation rate. The liquid side heat transfer is computed using the parameters of sloshing dynamics such as frequency, wave amplitude, and interface area. The parameters of sloshing dynamics are computed by the CFD code LOCI-Stream. The model predictions were compared with test data for several cases.

Cryogenic Tank Sloshing↗

Nuclear Power Fault Diagnostics and Preventative Maintenance Optimization

The nuclear industry is beginning to see reactors shut down—even after their operating licenses have been extended—because they are not economically competitive with other energy sources. These early closures happen primarily due to economic reasons, despite excellent safety records. Therefore, it is imperative to reduce costs in order to prevent these early closures. One of the contributors to these economic reasons is the large operations and maintenance costs. This paper showcases recent research on advanced fault diagnostics techniques and preventative maintenance optimization (PMO) for reducing NPP maintenance costs. Specifically, it focuses on the feedwater and condensate system (FWCS) for both pressurized- and boiling-water reactor (BWR) systems. The computerized maintenance management system (CMMS), which contains the plant’s digital record of all corrective maintenance (CM) and preventative maintenance (PM) work orders, provided the ground truth for locating potential faults and labeling the process data as either healthy or faulted. Various feature extraction techniques were used to further differentiate the faulted data from the healthy data. Through a cross-validation procedure, support vectors machines were used to label other test sets of process data as either healthy or faulted. With relatively few faults identified in the BWR system, the potential for PMO opens up, since an unnecessary amount of PM leads to inflated maintenance costs. The steps for PMO are summarized, from component health determinations to recommendations for action. An example of PMO assessment is presented for condensate pumps, condensate booster pumps, and the respective motors that drive them.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of the Glycolate Destruction Process with Sodium Permanganate in the Defense Waste Processing Facility (DWPF) - 20141

The Savannah River Site (SRS) seeks to replace formic acid with glycolic acid as a chemical reductant in the Defense Waste Processing Facility (DWPF), where borosilicate glass is mixed with high-level radioactive waste, melted at high temperatures, then poured into stainless steel canisters for safe storage. Prior research and development have demonstrated the feasibility and advantages of the new nitric-glycolic acid flowsheet over the current nitric-formic acid flowsheet to chemically adjust the radioactive sludge slurry waste in the Sludge Receipt and Adjustment Tank (SRAT) prior to vitrification. Use of glycolic acid reduces hydrogen and ammonia generation during the reduction process, thus reducing flammability hazards and purge requirements in the DWPF processing vessels. In addition, glycolic acid will support the new Salt Waste Processing Facility (SWPF) by allowing for receipt of higher volumes of waste due to reduction of flammable gases, increased boil-up rates in the vessels, and easing the processing of future sludge batches containing high levels of mercury. However, during DWPF operations, trace amounts of glycolate are anticipated to be entrained in the recycle stream and sent to the Concentration, Storage, and Transfer Facilities (CSTF) via the Recycle Collection Tank (RCT). The RCT receives condensate from the Slurry Mix Evaporator Condensate Tank (SMECT) and Off-gas Condensate Tank (OGCT) that may contain unreacted glycolate. A literature review found the potential for hydrogen generation due to thermolysis of glycolate in caustic CSTF conditions. Savannah River National Laboratory (SRNL) conducted several tests on simulant and radioactive waste from various tanks at SRS and confirmed that glycolate added to waste at concentrations of approximately 1000 mg/L and higher generates hydrogen through thermolysis. There are potential operating scenarios in the future where glycolate concentration could exceed 1000 mg/L in the 2H Evaporator Drop Tank, the highest accumulation point for DWPF organics received via recycle. These findings presented a need to develop another process to mitigate the impact of glycolic acid to the CSTF. Several DWPF compatible options were evaluated for their ability to destroy glycolate in the DWPF recycle stream under various processing conditions, thereby mitigating its introduction to the CSTF. Downselection testing identified sodium permanganate as the most promising and simplest option to oxidize glycolate. It has been demonstrated to be effective in various RCT simulant compositions, operating temperatures, oxidant addition rates, solution pH, and initial glycolate concentrations. A feasibility study identified existing tanks within the facility that could be used for receiving and storing the commercially available sodium permanganate, as well as feeding it to the RCT for processing. The use of existing equipment as well as the ability to purchase the pre-mixed chemical reduces implementation and operational complexity. The downstream impacts of the sodium permanganate reaction were also evaluated and demonstrated to have minimal impact on other chemical species present in the RCT and CSTF, as well as on the materials of construction of the RCT and CSTF vessels and associated piping and instrumentation. Future work is in progress to validate the glycolate destruction process with testing in actual radioactive RCT waste before implementation in DWPF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oxidation of Glycolate in the Defense Waste Processing Facility (DWPF) Recycle Collection Tank - 20305

The Savannah River Site's Defense Waste Processing Facility (DWPF) operations are being upgraded with the introduction of the Nitric-Glycolic Flowsheet. Glycolic acid has been shown superior to formic acid as the reducing acid used during chemical processing. The new flowsheet improves or maintains necessary parameters such as 1) reduction of mercury, 2) adjustment of feed rheology and 3) adjustment of melter oxidation/reduction potential. Further, the potential for catalytic hydrogen generation in DWPF processing is virtually eliminated. DWPF process condensates are collected and returned to the SRS Concentration, Storage and Transfer Facilities (CSTF). The Recycle Collection Tank (RCT) collects off-gas condensate during chemical processing, vitrification, and other unit operations performed in DWPF and is the singular return vessel delivering recycle effluent back to CSTF. Each batch of recycle may contain a small amount of glycolate from chemical processing and melter off-gas condensates. To avoid potential flammability issues due to thermolysis of glycolate in the CSTF, chemical oxidation within the RCT has been investigated as an option for mitigating the transfer of glycolate. Sodium permanganate has been down-selected as the best option for oxidation of glycolate. Testing was performed using both 2-L and 22-L reactors (16,800:1 and 1,530:1 scale by volume) with non-radioactive waste simulants to approximate the expected RCT compositions. RCT simulants were evaluated at various process pH and temperature conditions. Also, RCT operations, namely the sequence of addition of corrosion inhibitors (NaOH and NaNO{sub 2}) versus a permanganate strike, were evaluated. Glycolate was introduced via a sludge simulant to mimic both expected entrainment and abnormal process foam-over conditions - the range being between 68 and 5100 mg/kg glycolate. Glycolate destruction was monitored by ion chromatography (IC). The corresponding manganese behavior was monitored in real-time using in situ ultraviolet-visible (UV-Vis) spectroscopy. RCT glycolate content can be reduced to below the IC detection limit within 90 minutes for all concentrations investigated. Ion Chromatography analysis revealed that under alkaline conditions, glycolate is primarily oxidized to oxalate with no significant formation of CO{sub 2} or carbonate, and nitrite is not oxidized to nitrate. Initially, complete oxidation of organics species and nitrite was assumed. Determination of the mechanistic chemical reaction has allowed the required amount of permanganate to be more accurately predicted and the total addition to be significantly reduced. UV-Vis measurements reveal that permanganate (Mn{sup 7+}) is reduced to manganate (Mn{sup 6+}) in the RCT. The oxidant stoichiometry is defined by using the initial permanganate to glycolate (P/G) molar ratio. At low initial glycolate concentration (68 and 140 mg/kg), the minimum required initial permanganate to glycolate (P/G) molar ratio was found to be 5-6. With high initial glycolate concentrations (5100 mg/kg) a lower (P/G) molar ratio of ∼2.5 was needed. The final portion of this effort supporting the nitric/glycolic flowsheet will be to test actual (fully radioactive) RCT samples as per the above simulant tests. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Numerical Analysis of Water Harvesting from Saturated Vapor with the Electrospray Water Droplet Injection in The Solar-Driven Desalination Applications

Solar-driven seawater desalination systems provide freshwater through environmentally friendly and carbon-neutral processes. Air humidification and dehumidification desalination (HDD) systems extract water directly from moist air. This paper focuses on a new solar-driven seawater desalination system that shares some common traits with HDD systems but in which the air is eliminated from the process. Seawater is vaporized by solar thermal radiation in high-performance solar panels. Water vapor flows to a new electro-condensation chamber and passes through a series of electrosprays, which inject small nuclei of freshwater droplets into the vapor clouds. Here, due to dielectrophoresis and electrohydrodynamic flows, the vapor molecules are captured by the charged droplets, and vapor is condensed at the droplet surface. The water vapor condensation was modeled by using the multiphase flow numerical model. The CFD model, which was also experimentally validated, used SprayFoam solver modules available in the Open FOAM® CFD open-source software. In preliminary results, 802 grams/(hr-m2) (grams per hour per unit area) of water was harvested directly from moist air at 24C and 90% relative humidity. The simulation results indicated that freshwater productivity could increase up to 4,000 grams/(hr-m2) for fully saturated air conditions. This represents about 5 times the water productivity rate of current conventional HDD systems today. In addition, energy consumption could be reduced by 80 percent compared to conventional HDD systems.

Electrospray, electro-condensation, solar, droplet↗

Modeling salt adsorption in electrical double layer for capacitive deionization

Abstract This work presents an electrical double layer (EDL) model for capacitive deionization (CDI) by intercorrelating the salt adsorption, the electrode voltage, and the surface charge density. The counterion condensation is considered a crucial contribution to salt adsorption because of the high surface charge density in the charged micropores. The counterions condense when the surface charge density exceeds a critical value, which is predicted by the counterion condensation theory. The EDL model accurately correlates the NaCl salt adsorption and electrode voltage with various surface charge densities and well predicts the salt adsorption in a wide range of external salt concentrations. The EDL model reproduces the non‐monotonic relationship between the salt adsorption and the specific surface area observed in experiments and provides an explanation from the modeling perspective. Exhibiting superior accuracy and predictability for salt adsorption, the EDL model could serve as an enabling tool contributing to the development of CDI processes.

Lin, Yu‐Jeng↗

Acoustic misalignment mechanism for axion dark matter

A rotation in the field space of a complex scalar field corresponds to a Bose-Einstein condensation of U(1) charges. We point out that fluctuations in this rotating condensate exhibit sound-wave modes, which can be excited by cosmic perturbations and identified with axion fluctuations once the U(1) charge condensate has been sufficiently diluted by cosmic expansion. We consider the possibility that these axion fluctuations constitute dark matter and develop a formalism to compute its abundance. We carefully account for the growth of fluctuations during the epoch where the complex scalar field rotates on the body of the potential and possible nonlinear evolution when the fluctuations become non-relativistic. We find that the resultant dark matter abundance can exceed the conventional and kinetic misalignment contributions if the radial direction of the complex scalar field is sufficiently heavy. The axion dark matter may also be warm enough to leave imprints on structure formation. We discuss the implications of this novel dark matter production mechanism — acoustic misalignment mechanism — for the axion rotation cosmology, including kination domination and baryogenesis from axion rotation, as well as for axion searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗