Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPRESSORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Low cost scroll compressor or vacuum pump

A low cost scroll device and methods of manufacturing the same are described. The scroll device includes, for example, a drive pin hole and bearing bores machined into a scroll of the scroll device from the same side as the involute of the scroll; idler shaft assemblies with no more than one bearing in the orbiting scroll for mechanically coupling the orbiting scroll to the fixed scroll; and an epoxy coating applied using a process that requires assembly of the scroll device only once.

Mesward, Joshua R.↗

Dual drive co-rotating spinning scroll compressor or expander

A dual-drive co-rotating scroll device includes a housing; a first scroll rotatably mounted within the housing via a first cylindrical extension and a first plurality of bearings, and having a first axis of rotation; and a second scroll rotatably mounted within the housing via a second cylindrical extension and a second plurality of bearings, and having a second axis of rotation different than the first axis of rotation. At least one of the first cylindrical extension and the second cylindrical extension may comprise a plurality of permanent magnets and operate as a rotor of a first motor. An Oldham ring may be positioned between the first scroll and the second scroll and configured to maintain a relative angular position between the first scroll and the second scroll.

Wilson, John P. D.↗

Turbomachinery for Low-to-High Mach Number Flight

The thrust capability of turbojet cycles is reduced at high flight Mach number (3+) by the increase in inlet stagnation temperature. The 'hot section' temperature limit imposed by materials technology sets the maximum heat addition and, hence, sets the maximum flight Mach number of the operating envelope. Compressor pre-cooling, either via a heat exchanger or mass-injection, has been suggested as a means to reduce compressor inlet temperature and increase mass flow capability, thereby increasing thrust. To date, however, no research has looked at compressor cooling (i.e., using a compressor both to perform work on the gas path air and extract heat from it simultaneously). We wish to assess the feasibility of this novel concept for use in low-to-high Mach number flight. The results to-date show that an axial compressor with cooling: (1) relieves choking in rear stages (hence opening up operability), (2) yields higher-pressure ratio and (3) yields higher efficiency for a given corrected speed and mass flow. The performance benefit is driven: (i) at the blade passage level, by a decrease in the total pressure reduction coefficient and an increase in the flow turning; and (ii) by the reduction in temperature that results in less work required for a given pressure ratio. The latter is a thermodynamic effect. As an example, calculations were performed for an eight-stage compressor with an adiabatic design pressure ratio of 5. By defining non-dimensional cooling as the percentage of compressor inlet stagnation enthalpy removed by a heat sink, the model shows that a non-dimensional cooling of percent in each blade row of the first two stages can increase the compressor pressure ratio by as much as 10-20 percent. Maximum corrected mass flow at a given corrected speed may increase by as much as 5 percent. In addition, efficiency may increase by as much as 5 points. A framework for characterizing and generating the performance map for a cooled compressor has been developed. The approach is based upon CFD computations and mean line analysis. Figures of merit that characterize the bulk performance of blade passage flows with and without cooling are extracted from CFD solutions. Such performance characterization is then applied to a preliminary compressor design framework (mean line). The generic nature of this approach makes it suitable for assessing the effect of different types of compressor cooling schemes, such as heat exchange or evaporative cooling (mass injection). Future work will focus on answering system level questions regarding the feasibility of compressor cooling. Specifically, we wish to determine the operational parametric space in which compressor cooling would be advantageous over other high flight Mach number propulsion concepts. In addition, we will explore the design requirements of cooled compressor turbomachinery, as well as the flow phenomena that limit and control its operation, and the technology barriers that must be crossed for its implementation.

Tan, Choon S.↗

Development of an Active, Man-Portable, Cooling System with Dehumidification Capabilities for Personal Protective Clothing/Equipment

Mainstream Engineering Corporation completed a highly successful SBIR program, during which we developed and commercialized products for microclimate cooling systems (MCS) and the heating, ventilation, air-conditioning, and refrigeration (HVAC/R) industry. We are marketing the MCS family of products for use with personal protective clothing/equipment (PPC/PPE) for firefighters, workers in clean rooms, HAZMAT response and other contamination/remediation teams, and military personnel that are required to wear Mission-Oriented Protective Posture (MOPP) suits and bomb disposal suits. Workers in these industries risk heat stress when confined within protective garments while in hot and humid environments. Our family of MCS and HVAC/R products that resulted from this SBIR program includes: 1. Active, Man-Portable, MCS for PPC/E—Our active system provides 350 W cooling of personal cooling for workers in thermally stressed environments. Although industrially hardened, this system is compact (0.69 ft 3 ) and lightweight (22.9 lbs). The MSC is easily decontaminated or disposed of between uses. 2. Miniature Screw Compressor for MCS—Our 350 Wcooling miniature screw compressor was originally designed for MCS and personal cooling systems. Occupying only 11 in 3 and weighing 1.4 lbs, the size and weight are less than any commercially available compressor with a similar cooling capacity. This miniature screw compressor is marketable as a low-pressure compressor or refrigerant pump. 3. Miniature Sliding Vane Compressor and Drive for MCS—Our 350 Wcooling compressor subassembly consists of a commercial miniature sliding vane compressor packaged with our motor controller. At 29.4 in3 and 1.5 lbs, this compressor is larger and heavier than the miniature screw but is lower cost and capable of producing higher head pressure. 4. Small Screw Compressor for HVAC/R—Our 50 kW cooling small screw compressor is for commercial HVAC/R applications. This compressor is extremely power dense at 0.34 ft 3 and 43 lbs and has a specific cooling capacity (kW/lb) five times greater than existing commercial compressors. We demonstrated high reliability (>5,100 hrs of operation and >3,400 on/off cycles), and we are currently discussing commercialization opportunities with laser manufacturers for cooling of their high-power devices. This final report summarizes the design, fabrication, testing, features, and benefits of each product. The commercialization potential and recommendations for the future are included.

42 ENGINEERING↗

Boosting devices with integral features for recirculating exhaust gas

According to one embodiment of the invention, a compressor housing includes a compressor inlet in fluid communication with a compressor volute configured to house a compressor wheel, the compressor inlet configured to provide a first air flow to the compressor wheel and a compressor outlet in fluid communication with the compressor volute, the compressor outlet configured to direct a compressed gas to an intake manifold. The compressor housing further includes an exhaust gas recirculation inlet port in fluid communication with the compressor volute, the exhaust gas recirculation inlet port being configured to combine an exhaust gas flow with the air flow to the compressor wheel.

33 ADVANCED PROPULSION SYSTEMS↗

Low-GWP HVAC System with Ultra-small Centrifugal Compression

Mechanical Solutions, Incorporated (MSI) was awarded a contract from the United States Department of Energy under Contract DE-EE0007042 to advance the potential of vapor compression utilizing an advanced high speed centrifugal compressor with an advanced heat exchanger design. The design was mandated to maintain high efficiency while utilizing a low GWP refrigerant. The specific goal of this program was to develop an advanced 5 ton air conditioning system. The target of the air conditioner is residential and commercial. To accomplish these goals, MSI teamed with Lennox International, a leading air conditioning manufacturer. MSI would design, oversee manufacturing, assemble, and test the compressor, while Lennox designed the heat exchanger and tested the overall air conditioner. Lennox initiated the project with a detailed cycle analysis that examined systems and refrigerants. At various break points, MSI performed a preliminary compressor design to identify realizable targets. Initially, the refrigerant that was targeted was R1234ze(E), but this was subsequently rejected over concerns of flammability. R515a was ultimately accepted as a qualified fluid based upon its GWP and flammability rating. MSI performed a complete design of the centrifugal compressor based upon the cycle system design and analysis. The design was based upon advanced aerodynamics utilizing transient Computational Fluid Dynamics (CFD), as well as mechanical and rotordynamic analysis. A detailed materials investigation was conducted to ensure mechanical integrity and refrigerant compatibility. To achieve the high rotational speed required by the compressor (105,300 rpm), foil bearings were designed by MSI, as was a high speed motor to provide the required torque for the compressor. All elements of the design complied with Design for Manufacturing and Assembly (DFMA) principles. The compressor was manufactured in components, utilizing specializing subcontractors throughout the country. The components were assembled into an operational compressor in MSI’s Albany facility, where it was tested in the MSI refrigeration test loop. The compressor achieved 90% of its maximum speed during testing at MSI. The interaction between the inverter and the high speed motor was the reason that full speed could not be attained. The compressor operated smoothly and quietly at all speeds, with the bearings performing as expected. The compressor was then shipped to Lennox’s facilities in Texas, where it was tested in the entire air conditioning system. Lennox was able to achieve 95% of the maximum rotational speed. They employed the same inverter as MSI. Lennox compiled the results of the testing and based upon the results, a go forward plan has been developed to correct the issues with the inverter, as well as redesign some parts that proved to be a challenge during the program. The consensus of the team is that a fully functional air conditioning system can be developed to achieve all of the goals identified in this program.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Extension of a Virtual Refrigerant Charge Sensor

The primary goal of the work described in this paper was to evaluate and extend a virtual refrigerant charge sensor (VRC) for determining refrigerant charge for equipment having variable-speed compressors and fans. To evaluate the accuracy of the VRC, data were first collected from previous laboratory tests for different systems and over a wide range of operating conditions. In addition, new laboratory tests were performed to consider conditions not available within the existing data set. The systems for the new laboratory tests were two residential ductless split heat pump systems that employ a variable-speed compressor and R-410a as the refrigerant. Based on the evaluations, the original virtual charge sensor (termed model I) was found to work well in estimating the refrigerant charge for systems with a variable-speed compressor under many operating conditions. However, for extreme test conditions such as low outdoor temperatures and low compressor speed, the VRC needed to be improved. To overcome the limitations, the model associated with the VRC sensor was modified to include a term involving the inlet quality to the evaporator estimated from the condenser outlet condition (termed model II). Both model I and II showed good performance in terms of predicting charge levels for systems with a constant speed compressor, but model II gave better performance for systems with a variable-speed compressor. However, when the superheat of the compressor was zero, neither model I nor II could accurately predict charge level. Therefore, a third approach (Model III) was developed that includes the discharge superheat of the compressor. This model improved performance for a laboratory-tested system that included a number of points with no superheat entering the compressor.

Kim, Woohyun↗

Development and evaluation of virtual refrigerant mass flow sensors for fault detection and diagnostics

Refrigerant mass flow rate is an important measurement for monitoring equipment performance and enabling fault detection and diagnostics. However, a traditional mass flow meter is expensive to purchase and install. A virtual refrigerant mass flow sensor (VRMF) uses a mathematical model to estimate flow rate using low-cost measurements and can potentially be implemented at low cost. This study evaluates three VRMFs for estimating refrigerant mass flow rate. The first model uses a compressor map that relates refrigerant flow rate to measurements of inlet and outlet pressure, and inlet temperature measurements. The second model uses an energy-balance method on the compressor that uses a compressor map for power consumption, which is relatively independent of compressor faults that influence mass flow rate. The third model is developed using an empirical correlation for an electronic expansion valve (EEV) based on an orifice equation. The three VRMFs are shown to work well in estimating refrigerant mass flow rate for various systems under fault-free conditions with less than 5% RMS error. Each of the three mass flow rate estimates can be utilized to diagnose and track the following faults: 1) loss of compressor performance, 2) fouled condenser or evaporator filter, 3) faulty expansion device, respectively. For example, a compressor refrigerant flow map model only provides an accurate estimation when the compressor operates normally. When a compressor is not delivering the expected flow due to a leaky suction or discharge valve or other internal fault, the energy-balance or EEV model can provide accurate flow estimates. In this paper, the flow differences provide an indication of loss of compressor performance and can be used for fault detection and diagnostics.

Kim, Woohyun↗

Simulation of IST Turbomachinery Power-Neutral Tests with the ANL Plant Dynamics Code

The validation of the Plant Dynamics Code (PDC) developed at Argonne National Laboratory (ANL) for the steady-state and transient analysis of supercritical carbon dioxide (sCO2) systems has been continued with new test data from the Naval Nuclear Laboratory (operated by Bechtel Marine Propulsion Corporation) Integrated System Test (IST). Although data from three runs were provided to ANL, only two of the data sets were analyzed and described in this report. The common feature of these tests is the power-neutral operation of the turbine-compressor shaft, where no external power through the alternator was provided during the tests. Instead, the shaft speed was allowed to change dictated by the power balance between the turbine, the compressor, and the power losses in the shaft. The new test data turned out to be important for code validation for several reasons. First, the power-neutral operation of the shaft allows validation of the shaft dynamics equations in asynchronous mode, when the shaft is disconnected from the grid. Second, the shaft speed control with the compressor recirculation (CR) valve not only allows for testing the code control logic itself, but it also serves as a good test for validation of both the compressor surge control and the turbine bypass control actions, since the effect of the CR action on the loop conditions is similar for both of these controls. Third, the varying compressor-inlet temperature change test allows validation of the transient response of the precooler, a shell-and-tube heat exchanger. The first transient simulation of the compressor-inlet temperature variation Test 64661 showed a much slower calculated response of the precooler in the calculations than the test data. Further investigation revealed an error in calculating the heat exchanger tube mass for the PDC dynamic equations that resulted in a slower change in the tube wall temperature than measured. The transient calculations for both tests were done in two steps. The first step was done in the same fashion as the FY15 IST analysis, where the CR valve position and the turbine-compressor shaft speed were specified through the PDC input based on the test values. On the second step, the turbine-compressor shaft dynamics equations were invoked by specifying that the shaft is disconnected from the grid. In addition, the CR valve control was used to control the shaft speed, based on the turbine bypass control logic already implemented in the PDC. For the shaft power balance, the friction (windage) loss is calculated based on the shaft balance at the steady-state conditions and is assumed to be scaled to the third power of shaft speed in the transient. Both the steady-state and transient simulations of both tests showed good agreement with the test data. The only significant difference was the turbine performance, which was not predicted as well as it was in the previous IST simulation, resulting in the prediction of a somewhat different flow split between the two turbines. This flow split difference is believed to be the result of not addressing the recent turbine modifications in the model. In addition, the full simulation of the turbine-compressor speed variation Test 65261-P with shaft speed control showed greater a difference with the test data later in the transient than the other test. Further analysis of the results revealed that this difference is most likely due to scaling the shaft windage losses only with the shaft speed and ignoring its dependency on the fluid density in the shaft cavity. Based on the results of steady state and transient calculations of the Tests 64661 and 65216-P, several areas of future improvements for the PDC simulation of the IST are identified.

42 ENGINEERING↗