Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Femtosecond Laser Desorption Postionization MS vs ToF-SIMS Imaging for Uncovering Biomarkers Buried in Geological Samples

The study of lipid molecular fossils by traditional biomarker analysis requires bulk sample crushing, followed by solvent extraction, and then the analysis of the extract by gas chromatography-mass spectrometry (GC–MS). This traditional analysis mixes all organic compounds in the sample regardless of their origins, with a loss of information on the spatial distribution of organic molecules within the sample. These shortcomings can be overcome using the chemical mapping of intact samples. Spectroscopic techniques such as UV fluorescence or Raman spectroscopy, laser ablation inductively coupled plasma mass spectrometry, and time-of-flight secondary ion mass spectrometry (ToF-SIMS) are among those elemental and molecular mapping techniques. This study employed femtosecond (fs) laser ablation combined with single-photon ionization, a method called fs-laser desorption postionization mass spectrometry (fs-LDPI-MS). In this work, a pulsed ~75 fs, 800 nm laser was used to ablate the geological sample, which was then photoionized after a few microseconds by a pulsed 7.9 eV vacuum ultraviolet laser. An organic carbon-rich geological sample was used for this study to map hydrocarbon biomarkers in sediments that were previously studied by GC–MS. The petrography of this sample was examined by optical and fluorescence microscopy. It is demonstrated here that fs-LDPI-MS combined with petrography for multimodal imaging can expose buried compounds within the sample via in situ layer removal. When used in conjunction with traditional organic geochemical analysis, this method has the potential to determine the spatial distribution of organic biomarkers in geological material. Finally, fs-LDPI-MS imaging data are compared with ToF-SIMS imaging that is commonly used for such studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Retention Index Score Assumptions to Refine GC–MS Metabolite Identification

As metabolomics grows into a high-throughput and high demand research field, current metrics for the identification of small molecules in gas chromatography–mass spectrometry (GC–MS) still require manual verification. Though steps have been taken to improve scoring metrics by combining spectral similarity (SS) and retention index (RI), the problem persists. A large body of literature has analyzed and refined SS scores, but few studies have explicitly studied improvements to RI scores. Here, in this study, we examined whether uninvestigated assumptions of the RI score are valid and propose ways to improve them. Query RIs were matched to library RI with a generous window of ±35 to avoid unintentional removal of valid compound identifications. Each match was manually verified as a true positive (TP), true negative, or unknown. Metabolites with at least 30 TP identifications were included in downstream analyses, resulting in a total of 87 metabolites from samples of varying complexity and type (e.g., amino acid mixtures, human urine, fungal species, and so on.). Our results showed that the RI score assumptions of normality, consistent variance across metabolites, and a mean error centered at 0 are often violated. We demonstrated through a cross-validation analysis that modifying these underlying assumptions according to empirical metabolite-specific distributions improved the TP and negative rankings. Further, we statistically determined the minimum number of samples required to estimate distributional parameters for scoring metrics. Overall, this work proposes a robust statistical pipeline to reduce the time bottleneck of metabolite identification by improving RI scores and thus minimize the effort to complete manual verification.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Natural Abundance Isotope Ratio Measurements of Organic Molecules Using 21 T FTICR MS

Subtle variations in stable isotope ratios at natural abundance are challenging to measure but can yield critical insights into biological, physical, and geochemical processes. Well established methods, particularly multi-collector, gas-source or plasma isotope ratio mass spectrometry (IRMS) are the gold standard for stable isotope measurement but inherent limitations in these approaches make them ill-suited to determining site-specific and multiply substituted isotopic abundances of all but a few compounds, or to characterizing mixtures or larger intact molecules. Additionally, Fourier transform mass spectrometry (FTMS), namely Orbitrap mass spectrometry, has recently demonstrated the ability to measure natural abundance isotope ratios with chemically informative accuracy and precision. Here, we report the first use of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) for the accurate (<1‰) and precise (<1‰ standard error) simultaneous determination of $δ$ 13 C and $δ$ 15 N in caffeine isotopologues and provide a discussion of the critical instrumental parameters necessary to make such measurements. Finally, we report the ability to make these measurements with online liquid chromatography, expanding the ability of this technique to explore mixtures in the future.

07 ISOTOPE AND RADIATION SOURCES↗

Orthogonal Injection Ion Funnel Interface Providing Enhanced Performance for Selected Reaction Monitoring-Triple Quadrupole Mass Spectrometry

The electrodynamic ion funnel facilitates efficient focusing and transfer of charged particles in the higher pressure regions (e.g. ion source interfaces) of mass spectrometers, and thus providing increased sensitivity. An “off-axis” ion funnel design has been developed to reduce the source contamination and interferences from, e.g. ESI droplet residue and other poorly focused neutral or charged particles with very high mass-to charge ratios. In this study a dual ion funnel interface consisting of an orthogonal higher pressure electrodynamic ion funnel (HPIF) and an ion funnel trap combined with a triple quadruple mass spectrometer was developed and characterized. An orthogonal ion injection inlet and a repeller plate electrode was used to direct ions to an ion funnel HPIF at 9-10 Torr pressure. Several critical factors for the HPIF were characterized, including the effects of RF amplitude, DC gradient and operating pressure. Compared to the triple quadrupole standard interface more than 4-fold improvement in the limit of detection for the direct quantitative MS analysis of low abundance peptides was observed. Lastly, the sensitivity enhancement in liquid chromatography selected reaction monitoring (SRM) analyses of low abundance peptides spiked into a highly complex mixture was also compared with that obtained using a both commercial s-lens interface and a in-line dual ion funnel interface.

47 OTHER INSTRUMENTATION↗

Source Attribution of Cyanides using Anionic Impurity Profiling, Stable Isotope Ratios, Trace Elemental Analysis and Chemometrics

Chemical attribution signatures (CAS) for chemical threat agents (CTAs) are being investigated to provide an evidentiary link between CTAs and specific sources to support criminal investigations and prosecutions. In a previous study, anionic impurity profiles developed using high performance ion chromatography (HPIC) were demonstrated as CAS for matching samples from eight potassium cyanide (KCN) stocks to their reported countries of origin. Herein, a larger number of solid KCN stocks (n = 13) and, for the first time, solid sodium cyanide (NaCN) stocks (n = 15) were examined to determine what additional sourcing information can be obtained through anion, carbon stable isotope, and elemental analyses of cyanide stocks by HPIC, isotope ratio mass spectrometry (IRMS), and inductively coupled plasma optical emission spectroscopy (ICP-OES), respectively. The HPIC anion data was evaluated using the variable selection methods of Fisher-ratio (F-ratio), interval partial least squares (iPLS), and genetic algorithm-based partial least squares (GAPLS) and the classification methods of partial least squares discriminate analysis (PLSDA), K nearest neighbors (KNN), and support vector machines discriminate analysis (SVMDA). In summary, hierarchical cluster analysis (HCA) of anion impurity profiles from multiple cyanide stocks from six reported country of origins resulted in cyanide samples clustering into three groups: Czech Republic, Germany, and United States, independent of the associated alkali metal (K or Na). The three country groups were independently corroborated by HCA of cyanide elemental profiles and corresponded to countries with known solid cyanide factories. Both the anion and elemental CAS are believed to originate from the aqueous alkali hydroxides used in cyanide manufacture. Carbon stable isotope measurements resulted in two clusters: Germany and United States (the single Czech stock grouped with United States stocks). The carbon isotope CAS is believed to originate from the carbon source and process used to make the HCN utilized in cyanide synthesis. Classification errors for two validation studies using anion impurity profiles collected over five years on different instruments were as low as zero for KNN and SVMDA, demonstrating the excellent reliability (so far) of using anion impurities for matching a cyanide sample to its country of manufacture (i.e., factory). Variable selection reduced errors for those classification methods having errors greater than zero with iPLS-forward selection, and F-ratio typically providing the lowest errors. Finally, using anion profiles to match cyanides to a specific stock or stock group resulted in cross-validation errors ranging from zero to 5.3%.

chemical forensics↗

A Synchrotron-Based Vacuum Ultraviolet Photoionization Mass Spectrometer-Coupled Microreactor To Probe Thermocatalysis

Vacuum ultraviolet photoionization (VUV-PI) mass spectrometry offers an isomer-selective and universal ionization with minimal fragmentation detection of organics in complex chemical systems such as pyrolysis and combustion. Here, in this study, we report a state-of-the-art experimental setup of a universal catalytic microreactor combined with a molecular beam to investigate the thermocatalytic oxidation of a heterogeneous system relevant for probing reactions at gas–solid interfaces. In strong contrast to traditional off-line analytical methods, this technique is capable of identifying and quantifying short-lived species (radicals) as well as stable products to decipher initial reaction steps via the detection of nascent products. The thermocatalytic oxidative degradation of exo-tetrahydrodicyclopentadiene (JP-10), a high energy-density hydrocarbon fuel, over solid titanium–aluminum–boron reactive mixed metal nanopowder (Ti-Al-B RMNP) is exploited to showcase potential applications. Overall, some 59 nascent gas-phase products are identified via photoionization efficiency (PIE) curves, including oxygenated species and hydrocarbons comprising closed-shell molecules and radicals. The critical temperature for complete oxidative decomposition of JP-10 was lowered by 450 K from 1400 K to 950 K, indicating an efficient thermocatalytic action of Ti-Al-B nanoparticles on JP-10. The enabling of a universal chemical microreactor along with VUV-PI mass spectrometry broadens the applicability of this technique to hydrocarbon fuel oxidation and pyrolysis characterization. This isomer-selective sensitive probing along with the detection of radical transients makes the aforementioned technique superior to other conventional analytical techniques such as microflow tube and pyrolysis-gas chromatography coupled with mass spectrometry for investigating similar pyrolysis reactions and comprehensive quantification.

Paul, Dababrata [Univ. of Hawaii at Manoa, Honolul↗

Separation of Americium in High Oxidation States from Curium Utilizing Sodium Bismuthate

A simple separation of americium from curium would support closure of the nuclear fuel cycle, assist in nuclear forensic analysis, and allow for more accurate measurement of neutron capture properties of 241 Am. Methods for the separation of americium from curium are however complicated and time-consuming due to the similar chemical properties of these elements. In this work a novel method for the separation of americium from curium in nitric acid media was developed using sodium bismuthate to perform both the oxidation and separation. Sodium bismuthate is shown to be a promising material for performing a simple and rapid separation. Curium is more strongly retained than americium on the undissolved sodium bismuthate at nitric acid concentrations below 1.0 M. A separation factor of ~90 was obtained in 0.1 M nitric acid. This separation factor is achieved within the first minute of contact and is maintained for at least 2 h of contact. Separations using sodium bismuthate were performed using solid–liquid extraction as well as column chromatography.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enabling Efficient and Confident Annotation of LC-MS Metabolomics Data through MS1 Spectrum and Time Prediction

Liquid chromatography coupled to electrospray ionization-mass spectrometry (LC–ESI-MS) is a versatile and robust platform for metabolomic analysis. However, while ESI is a soft ionization technique, in-source phenomena including multimerization, nonproton cation adduction, and in-source fragmentation complicate interpretation of MS data. Here, we report chromatographic and mass spectrometric behavior of 904 authentic standards collected under conditions identical to a typical nontargeted profiling experiment. The data illustrate that the often high level of complexity in MS spectra is likely to result in misinterpretation during the annotation phase of the experiment and a large overestimation of the number of compounds detected. However, our analysis of this MS spectral library data indicates that in-source phenomena are not random but depend at least in part on chemical structure. These nonrandom patterns enabled predictions to be made as to which in-source signals are likely to be observed for a given compound. Using the authentic standard spectra as a training set, we modeled the in-source phenomena for all compounds in the Human Metabolome Database to generate a theoretical in-source spectrum and retention time library. A novel spectral similarity matching platform was developed to facilitate efficient spectral searching for nontargeted profiling applications. Taken together, this collection of experimental spectral data, predictive modeling, and informatic tools enables more efficient, reliable, and transparent metabolite annotation.

60 APPLIED LIFE SCIENCES↗

Deep-Dive Targeted Quantification for Ultrasensitive Analysis of Proteins in Nondepleted Human Blood Plasma/Serum and Tissues

Mass spectrometry-based targeted proteomics (e.g., selected reaction monitoring, SRM) is emerging as an attractive alternative to immunoassays for protein quantification. Recently we have made significant progress in SRM sensitivity for enabling quantification of low ng/mL to sub-ng/mL level proteins in nondepleted human blood plasma/serum without affinity enrichment. However, precise quantification of extremely low abundant but biologically important proteins (e.g., ≤100 pg/mL in blood plasma/serum) using targeted proteomics approaches still remains challenging. To address this need, we have developed an antibody-independent Deep-Dive SRM (DD-SRM) approach that capitalizes on multidimensional high-resolution reversed-phase liquid chromatography (LC) separation for target peptide enrichment combined with precise selection of target peptide fractions of interest, significantly improving SRM sensitivity by ~5 orders of magnitude when compared to conventional LC-SRM. Application of DD-SRM to human serum and tissue has been demonstrated to enable precise quantification of endogenous proteins at ~10 pg/mL level in nondepleted serum and at <10 copies per cell level in tissue. Thus, DD-SRM holds great promise for precisely measuring extremely low abundance proteins or protein modifications, especially when high-quality antibody is not available.

Environmental Molecular Sciences Laboratory↗

Plasma Protein Turnover Rates in Rats Using Stable Isotope Labeling, Global Proteomics, and Activity-Based Protein Profiling

Protein turnover is important for general health on cellular and organism scales providing a strategy to replace old, damaged, or dysfunctional proteins. Protein turnover also informs of biomarker kinetics, as a better understanding of synthesis and degradation of proteins increases the clinical utility of biomarkers. Here, turnover rates of plasma proteins in rats were measured in vivo using a pulse-chase stable isotope labeling experiment. During the pulse, rats (n=5) were fed 13C6-labeled lysine (“heavy”) feed for 23 days to label proteins. During the chase, feed was changed to an unlabeled equivalent feed (“light”), and blood was repeatedly sampled from rats over 10 time points for 28 days. Plasma samples were digested with trypsin, and analyzed with liquid chromatography-tandem mass spectrometry (LC-MS/MS). MaxQuant was used to identify peptides and proteins, and quantify heavy:light lysine ratios. A system of ordinary differential equations was used to calculate protein turnover rates. Using this approach, 273 proteins were identified, and turnover rates were quantified for 157 plasma proteins with half-lives ranging 0.3-103 days. For the ~70 most abundant proteins, variability in turnover rates among rats was low (median coefficient of variation: 0.09). Activity-based protein profiling was applied to pooled plasma samples to enrich serine hydrolases using a fluorophosphonate (FP2) activity-based probe. This enrichment resulted in turnover rates for an additional 17 proteins. This study is the first to measure global plasma protein turnover rates in rats in vivo, measure variability of protein turnover rates in any animal model, and utilize activity-based protein profiling for enhancing measurements of targeted, low-abundant proteins, such as those commonly used as biomarkers. Measured protein turnover rates will be important for understanding of the role of protein turnover in cellular and organism health as well as increasing the utility of protein biomarkers through better understanding of processes governing biomarker kinetics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Online Ozonolysis Combined with Ion Mobility-Mass Spectrometry Provides a New Platform for Lipid Isomer Analyses

One of the most significant challenges in contemporary lipidomics lies in the separation and identification of lipid isomers that differ only in site(s) of unsaturation or geometric configuration of the carbon-carbon double bonds. While analytical separation techniques including ion mobility spectrometry (IMS) and liquid chromatography (LC) can separate isomeric lipids under appropriate conditions, conventional tandem mass spectrometry cannot provide unequivocal identification. To address this challenge, we have implemented ozone-induced dissociation (OzID) in-line with LC, IMS and high resolution mass spectrometry. Modification of an IMS- capable quadrupole time-of-flight mass spectrometer was undertaken to allow the introduction of ozone into the high-pressure trapping ion funnel region preceding the IMS cell. This enabled the novel LC-OzID-IMS-MS configuration where ozonolysis of ionized lipids occurred rapidly (10 ms) without prior mass-selection. LC-elution time alignment combined with accurate mass and arrival time extraction of ozonolysis products facilitated correlation of precursor and product ions without mass-selection (and associated reductions in duty cycle). Unsaturated lipids across 11 classes were examined using this workflow in both positive and negative ion modalities and in all cases the positions of carbon-carbon double bonds were unequivocally assigned based on predictable OzID transitions. Under these conditions geometric isomers exhibited different IMS arrival time distributions and distinct OzID product ion ratios providing a means for discrimination of cis/trans double bonds in complex lipids. The combination of OzID with multidimensional separations shows significant promise for facile profiling of unsaturation patterns within complex lipidomes.

Environmental Molecular Sciences Laboratory↗

Targeted Quantification of Phosphorylation Dynamics in the Context of EGFR-MAPK Pathway

Large-scale phosphoproteomics with coverage of over 10,000 sites of phosphorylation have now been routinely achieved with advanced mass spectrometry (MS)-based workflows. However, accurate targeted MS-based quantification of phosphorylation dynamics, an important direction for gaining quantitative understanding of signaling pathways or networks, has been much less investigated. Herein, we report an assessment of the targeted workflow in the context of signal transduction pathways, using the epidermal growth factor receptor (EGFR)–mitogen-activated protein kinase (MAPK) pathway as our model. 43 phosphopeptides from the EGFR–MAPK pathway were selected for the study. The recovery and sensitivity of a workflow consisted of two commonly used enrichment methods, immobilized metal affinity chromatography (IMAC) and titanium oxide (TiO2), combined with selected reaction monitoring (SRM)-MS, were evaluated. The recovery of phosphopeptides by IMAC and TiO2 enrichment was quantified to be 38 ± 5% and 58 ± 20%, respectively, based on internal standards. Moreover, both enrichment methods provided comparable sensitivity from 1-100 g starting peptides. Robust quantification was consistently achieved for most targeted phosphopeptides when starting with 25-100 g peptides. However, the numbers of quantified targets significantly dropped when peptide samples were in the 1-25g range. Finally, IMAC-SRM was applied to quantify signaling dynamics of EGFR-MAPK pathway in Hs578T cells following 3 ng/mL EGF treatment. The kinetics of phosphorylation clearly revealed early and late phases of phosphorylation, even for very low abundance proteins. These results demonstrate the feasibility of robust targeted quantification of phosphorylation dynamics for specific pathways, even starting with relatively small amounts of protein.

Environmental Molecular Sciences Laboratory↗

Automated Separation of Uranium and Plutonium from Environmental Swipe Samples for Multiple Collector Inductively Coupled Plasma Mass Spectrometry

A fully automated method for the separation of low-concentration uranium from plutonium in environmental swipe samples has been developed. The offline chromatography system features renewable 1 mL Eichrom TEVA and UTEVA column generation from bulk resin slurry. Discrete fractions of the separated actinides are delivered into user defined vials for future analysis. Clean room background levels were achieved outside of a cleanroom environment with this method. Purification of uranium and plutonium from various sample matrixes and at various concentrations was successful. Major and minor isotope ratios for both elements were measured via multiple collector inductively coupled plasma mass spectrometry and were in good agreement with certified reference values. Lastly, validation of the separation method was conducted on archived environmental samples and agreed with values previously reported using standard column chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comprehensive Single-Shot Proteomics with FAIMS on a Hybrid Orbitrap Mass Spectrometer

Liquid chromatography (LC) prefractionation is often implemented to increase proteomic coverage; however, while effective, this approach is laborious, requires considerable sample amount, and can be cumbersome. We describe how interfacing a recently described high-field asymmetric waveform ion mobility spectrometry (FAIMS) device between a nanoelectrospray ionization (nanoESI) emitter and an Orbitrap hybrid mass spectrometer (MS) enables the collection of single-shot proteomic data with comparable depth to that of conventional two-dimensional LC approaches. This next generation FAIMS device incorporates improved ion sampling at the ESI–FAIMS interface, increased electric field strength, and a helium-free ion transport gas. With fast internal compensation voltage (CV) stepping (25 ms/transition), multiple unique gas-phase fractions may be analyzed simultaneously over the course of an MS analysis. We have comprehensively demonstrated how this device performs for bottom-up proteomics experiments as well as characterized the effects of peptide charge state, mass loading, analysis time, and additional variables. We also offer recommendations for the number of CVs and which CVs to use for different lengths of experiments. Internal CV stepping experiments increase protein identifications from a single-shot experiment to >8000, from over 100 000 peptide identifications in as little as 5 h. In single-shot 4 h label-free quantitation (LFQ) experiments of a human cell line, we quantified 7818 proteins with FAIMS using intra-analysis CV switching compared to 6809 without FAIMS. Single-shot FAIMS results also compare favorably with LC fractionation experiments. Furthermore, a 6 h single-shot FAIMS experiment generates 8007 protein identifications, while four fractions analyzed for 1.5 h each produce 7776 protein identifications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved Sensitivity and Separations for Phosphopeptides using Online Liquid Chromotography Coupled with Structures for Lossless Ion Manipulations Ion Mobility–Mass Spectrometry

Phosphoproteomics greatly augments proteomics and holds tremendous potential for insights into the modulation of biological systems for various disease states, etc. However, numerous challenges hinder conventional methods in terms of measurement sensitivity, throughput, and capabilities for confident phosphopeptide and phosphosite identification. In this work, we report the first example of integrating structures for lossless ion manipulations ion mobility (SLIM) IM-MS with online reversed-phase liquid chromatography (LC) to evaluate its potential for addressing the aforementioned challenges. A mixture of 51 heavy-labeled phosphopeptides was analyzed with a SLIM IM module having integrated ion accumulation and long-path separation regions. The SLIM IM-MS provided improved sensitivity over an established LC-SRM method, with limits of detection as low as 50 pM (50 amol/µl) for several peptides. Conventionally problematic phosphopeptide isomers could be resolved following an 18 m SLIM IM separation. The 2-D peak capacity was estimated as ~9000 for 90 min LC separation coupled to an 18 m SLIM IM separation, considerably higher than LC alone and providing a basis for both improved identification and quantification, with additional gains projected with the future use of longer path SLIM IM separations. Thus, LC-SLIM IM-MS offers great potential for improving the sensitivity, separation, and throughput of phosphoproteomics analyses.

Chouinard, Christopher D.↗

Exploiting the Dynamic Relationship between Peptide Separation Quality and Peptide Coisolation in a Multiple-Peptide Matches-per-Spectrum Approach Offers a Strategy To Optimize Bottom-Up Proteomics Throughput and Depth

We present that peptide cofragmentation leads to chimeric MS/MS spectra that negatively impact traditional single-peptide match-per-spectrum (sPSM) search strategies in proteomics. The collection of chimeric spectra is influenced by peptide coelution and the width of precursor isolation windows. Although peptide cofragmentation can be reduced by advanced chromatography, such as UHPLC and 2D-HPLC separation schemes, and narrower isolation windows, chimeric spectra can still be as high as 30–50% of the total MS/MS spectra collected. Alternatively, cofragmented peptides in chimeric spectra and the use of wider isolation windows benefit multiple-peptide matches-per-spectrum (mPSM) algorithms, such as CharmeRT, which facilitate the identification of several cofragmented peptides. Considering recent advancements in LC and mPSM methodologies, we present a comprehensive examination of the levels of chimeric spectra collected in the analysis of a HeLa digest measured using different LC modes of separation and isolation windows and compare the depth of identifications obtained when these data are annotated using a sPSM or a mPSM approach. Our results demonstrate that MS/MS data derived from 1D-HPLC strategies under different gradient schemes and searched with CharmeRT yielded higher average numbers of PSMs (11%–49%), peptide analytes (10%–16%), and peptide sequences (3%–10%) compared to data derived from 1D-UHPLC runs but searched with a sPSM strategy. Interestingly, data from a 2D-HPLC separation strategy benefits more from the application of CharmeRT results when compared to a 50 cm 1D-UHPLC column employing a 500 min gradient. In conclusion, these results provide new insights into how to better configure LC-MS/MS measurements for improved throughput and peptide identification in complex proteomes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probabilistic limit of detection for ricin identification using a shotgun proteomics assay

Robust and highly specific methods for the detection of the protein toxin ricin are of interest to the law enforcement community. In previous studies, methods based on liquid chromatography-tandem mass spectrometry shotgun proteomics have been proposed. The successful implementation of this approach relies on specific data evaluation criteria addressing (1) the quality of the mass spectrometric data, (2) the confidence of peptide identifications (peptide-spectrum matches), and (3) the number and sequence specificity of peptides detected. We present such data evaluation criteria, and use a novel approach to establish the limit of detection for this ricin assay. Specifically, we use logistic regression to determine the probability of detection for individual ricin peptides at different concentrations. We then apply basic rules from probability theory, combining these individual peptide probabilities into an overall assay limit of detection. This procedure yields an assay limit of detection for ricin at 42.5 ng on column or 21.25 ng/µL for a 2-µL injection. We also show that, in spite of the conventional wisdom that detergents are deleterious to mass spectrometric analyses, the presence of Tween-20 did not prevent detection of ricin peptides, and indeed assays performed in buffers that included Tween-20 gave better results than assays performed using other buffer formulations with or without detergent removal.

Heller, Natalie C.↗

Exploiting the Semidestructive Nature of Gas Cluster Ion Beam Time-of-Flight Secondary Ion Mass Spectrometry Imaging for Simultaneous Localization and Confident Lipid Annotations

Lipids have been considered as key players in cell signaling and disease. Information on their location and distribution within a biological system, under varying conditions, is necessary to understand the contributions of different lipid species to an altered phenotype. Imaging mass spectrometry techniques, such as time-of-flight secondary ion mass spectrometry (ToF-SIMS) and matrix-assisted laser desorption/ionization (MALDI), are capable of revealing global lipid distributions in tissues in an untargeted fashion. Yet, to confidently identify the species present in a sample, orthogonal analyses like tandem MS (MS/MS) are often required. This can be accomplished by bulk sample analysis with liquid chromatography (LC)-MS/MS, which can provide confident lipid identifications, at the expense of losing location-specific information. Here, using planarian flatworms as a model system, we demonstrate that imaging gas cluster ion beam (GCIB)-ToF-SIMS has the unique capability to simultaneously detect, identify, and image lipid species with subcellular resolution in tissue sections. The parallel detection of both, intact lipids and their respective fragments, allows for unique identification of some species without the need of performing an additional orthogonal MS/MS analysis. This was accomplished by correlating intact lipid and associated fragment SIMS images. The lipid assignments, respective fragment identities, and locations gathered from ToF-SIMS data were confirmed via LC-MS/MS on lipid extracts and ultrahigh mass resolution MALDI-MS imaging. Together, these data show that the semidestructive nature of ToF-SIMS can be utilized advantageously to enable both confident molecular annotations and to determine the locations of species within a biological sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗