Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

BISON Fuel Fragmentation Relocation and Dispersal (FFRD) Assessment Database for Eventual Use in Bayesian Calibration

Existing light-water reactor (LWR) fuel vendors have been interested in seeking increased discharge burnups of nuclear fuel rods for improved economics for quite a few years. With increased burnups come additional challenges that must be addressed. It has been experimentally observed that average burnups higher than the current regulatory limit of 62 MWd/kgU may undergo fuel fragmentation, relocation, and dispersal (FFRD) during a loss-of-coolant accident (LOCA). Industry must demonstrate approaches to mitigate FFRD. In an effort to support industry, the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program within the U.S. Department of Energy (DOE) has for several years invested in developing multiscale models and creating a validation/assessment database for these models to study the mechanisms driving FFRD. This report provides an update on changes made to the assessment database and new models added to BISON to support the study of fuel rod behavior during FFRD. An effort has been initiated this year to begin adding dedicated inputs to the publicly available Virtual Test Bed (VTB) repository for industry use. A section of this report details the efforts made in this area. NEAMS has recently developed new capabilities in the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework’s stochastic tools module for calibration using Bayesian inference. The goal in the future is to use these capabilities to calibrate and identify weaknesses in the existing BISON models for FFRD. The report concludes with a discussion on the models most likely to benefit the most from such calibration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mathematical models for base calibration in industrial robots

Mathematical models for the control systems of industrial robots permit calibration of the base, which is a single coordinate space for the industrial robot and the components being manipulated. Calibration of the base precedes operation of the robot. Control systems for industrial robots permit the storage and use of several calibrated bases in programming robot motion.

42 ENGINEERING↗

Calibration of X-Ray Diffraction Instruments for Residual-Stress Measurement

The deficiencies of existing standard iron and nickel samples for calibration by means of X-ray diffraction are noted. These standards cannot be used in calibration by magnetic noise recording. A new calibration method based on X-ray diffraction is proposed, using plane samples of the material employed in the manufacture of the actual structures. Theoretical analysis provides the basis for the development of null standards in which a plane sample is deformed by pure flexure or in a cantilever-beam configuration.

42 ENGINEERING↗

Parametric Sensitivity and Calibration for Kain-Fritsch Convective Parameterization Scheme in the WRF Model

Convective parameterizations used in weather and climate models all display sensitivity to model resolution and variable skill in different climatic regimes. Although parameters in convective schemes can be calibrated using observations to reduce model errors, it is not clear if the optimal parameters calibrated based on regional data can robustly improve model skill across different model resolutions and climatic regimes. In this study, this issue is investigated using a regional modeling framework based on the Weather Research and Forecasting (WRF) model. To quantify the response and sensitivity of model performance to model parameters, we identified five key input parameters and specified their ranges in the Kain-Fritsch (KF) convection scheme in WRF and calibrated them across different spatial resolutions, climatic regimes, and radiation schemes using observed precipitation data. Results show that the optimal values for the five input parameters in the KF scheme are close and model sensitivity and error exhibit similar dependence on the input parameters for all experiments conducted in this study despite differences in the precipitation climatology. We found that the model overall performances in simulating precipitation are more sensitive to the coefficients of downdraft (Pd) and entrainment (Pe) mass flux and starting height of downdraft (Ph). However, we found that rainfall biases, which are probably more related to structural errors, still exist over some regions in the simulation even with the optimal parameters, suggesting further studies are needed to identify the sources of uncertainties and reduce the model biases or structural errors associated with missed or misrepresented physical processes and/or potential problems with the modeling framework.

calibration↗

Adaptive Cognitive Mechanisms to Maintain Calibrated Trust and Reliance in Automation

Trust calibration for a human–machine team is the process by which a human adjusts their expectations of the automation’s reliability and trustworthiness; adaptive support for trust calibration is needed to engender appropriate reliance on automation. Herein, we leverage an instance-based learning ACT-R cognitive model of decisions to obtain and rely on an automated assistant for visual search in a UAV interface. This cognitive model matches well with the human predictive power statistics measuring reliance decisions; we obtain from the model an internal estimate of automation reliability that mirrors human subjective ratings. The model is able to predict the effect of various potential disruptions, such as environmental changes or particular classes of adversarial intrusions on human trust in automation. Finally, we consider the use of model predictions to improve automation transparency that account for human cognitive biases in order to optimize the bidirectional interaction between human and machine through supporting trust calibration. The implications of our findings for the design of reliable and trustworthy automation are discussed.

60 APPLIED LIFE SCIENCES↗

Estimating and Calibrating DER Model Parameters Using Levenberg–Marquardt Algorithm in Renewable Rich Power Grid

The proliferation of inverter-based distributed energy resources (IBDERs) has increased the number of control variables and dynamic interactions, leading to new grid control challenges. For stability analysis and designing appropriate protection controls, it is important that IBDER models are accurate. This paper focuses on the accurate estimation and parameter calibration of DER_A, a recently proposed aggregated IBDER model. In particular, we focus on the parameters of the reactive power–voltage regulation module. We formulate the problem of parameter tuning as a non-linear least square minimization problem and solve it using the Levenberg–Marquardt (LM) method. The LM method is primarily chosen due to its flexibility in adaptively selecting between the steepest descent and Gauss–Newton methods through a damping parameter. The LM approach is used to minimize the error between the actual measurements and the estimated response of the model. Further, the computational challenges posed by the numerical calculation of the Jacobian are tackled using a quasi-Newton root-finding approach. The proposed method is validated on a real feeder model in the northeastern part of the United States. The feeder is modeled in OpenDSS and the measurements thus obtained are fed to the DER_A model for calibration. The simulation results indicate that our approach is able to successfully calibrate the relevant model parameters quickly and with high accuracy, with a total sum of square error of 3.57 × 10 –7 .

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techniques for TPC Calibration: Application to Liquid Ar-TPCs

Large liquid argon TPCs are playing an increasingly important role in neutrino physics, and their calibration will be an essential component of their capability to reach the required performance and precision. Natural sources are extensively used but present limitations, since natural radioactivity from 39 Ar is of low energy, and the rate of cosmic ray muons is low when the detectors are placed deep underground. Argon gas TPCs have been calibrated with ionizing laser beams for several decades, and more recently the technique has been further developed for use in liquid TPCs. Other recent ideas include the use of external neutron generators creating pulses that propagate into the detector. This paper reviews the development of the laser and neutron methods for the calibration of argon TPCs and describes their planned implementation in the upcoming DUNE experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast and Accurate Pixel Calibration of Tof Neutron Diffractometers with Machine Learning

At a spallation neutron source, neutron pulses of varying energies are generated, and the detection of neutrons by instrument detectors is recorded as time-of-flight from the emission of the neutron pulse to its arrival at specific detector pixels with high time resolution. The flight path of neutrons from the moderator to the sample and then to the detector must be precisely calibrated at the detector-pixel level using standard powders, so the neutron events from all pixels can be time-focused to produce high-resolution diffraction patterns. Modern time-of-flight neutron diffractometers at spallation neutron sources are equipped with two-dimensional detectors with millimeter-scale pixelations. The number of pixels in a diffraction instrument can reach millions, which makes a single-pixel-level calibration process time-consuming or even impossible with conventional refinement or fitting approaches. Here we present a machine-learning-aided calibration process using a train-and-predict approach, in which machine learning models are trained on the relationship between an individual pixel time-of-flight diffraction pattern and its diffraction constant. These models use a portion of the available pixels for training, and a good model then predicts the diffraction constants precisely and rapidly for large sets of pixel diffraction patterns.

detector pixel calibration↗

IPEAT+: A Built-In Optimization and Automatic Calibration Tool of SWAT+

For almost 30 years, the Soil and Water Assessment Tool (SWAT) has been successfully implemented to address issues around various scientific subjects in the world. On the other hand, it has been reaching to the limit of potential flexibility in further development by the current structure. The new generation SWAT, dubbed SWAT+, was released recently with entirely new coding features. SWAT+ is designed to have far more advanced functions and capacities to handle challenging watershed modeling tasks for hydrologic and water quality processes. However, it is still inevitable to conduct model calibration before the SWAT+ model is applied to engineering projects and research programs. The primary goal of this study is to develop an open-source, easy-to-operate automatic calibration tool for SWAT+, dubbed IPEAT+ (Integrated Parameter Estimation and Uncertainty Analysis Tool Plus). There are four major advantages: (i) Open-source code to general users; (ii) compiled and integrated directly with SWAT+ source code as a single executable; (iii) supported by the SWAT developer group; and, (iv) built with efficient optimization technique. The coupling work between IPEAT+ and SWAT+ is fairly simple, which can be conducted by users with minor efforts. IPEAT+ will be regularly updated with the latest SWAT+ revision. If users would like to integrate IPEAT+ with various versions of SWAT+, only few lines in the SWAT+ source code are required to be updated. IPEAT+ is the first automatic calibration tool integrated with SWAT+ source code. Users can take advantage of the tool to pursue more cutting-edge and forward-thinking scientific questions.

54 ENVIRONMENTAL SCIENCES↗

CALIBRATED ULTRA FAST IMAGE SIMULATIONS FOR THE DARK ENERGY SURVEY

Image simulations are becoming increasingly important in understanding the measurement process of the shapes of galaxies for weak lensing and the associated systematic effects. For this purpose we present the first implementation of the Monte Carlo Control Loops (MCCL), a coherent framework for studying systematic effects in weak lensing. It allows us to model and calibrate the shear measurement process using image simulations from the Ultra Fast Image Generator (UFig) and the image analysis software SExtractor. We apply this framework to a subset of the data taken during the Science Verification period (SV) of the Dark Energy Survey (DES). We calibrate the UFig simulations to be statistically consistent with one of the SV images, which covers ∼0.5 square degrees. We then perform tolerance analyses by perturbing six simulation parameters and study their impact on the shear measurement at the one-point level. This allows us to determine the relative importance of different parameters. For spatially constant systematic errors and point-spread function, the calibration of the simulation reaches the weak lensing precision needed for the DES SV survey area. Furthermore, we find a sensitivity of the shear measurement to the intrinsic ellipticity distribution, and an interplay between the magnitude-size and the pixel value diagnostics in constraining the noise model. This work is the first application of the MCCL framework to data and shows how it can be used to methodically study the impact of systematics on the cosmic shear measurement.

79 ASTRONOMY AND ASTROPHYSICS↗

SYSTEMATIC UNCERTAINTIES IN THE SPECTROSCOPIC MEASUREMENTS OF NEUTRON STAR MASSES AND RADII FROM THERMONUCLEAR X-RAY BURSTS. III. ABSOLUTE FLUX CALIBRATION

Many techniques for measuring neutron star radii rely on absolute flux measurements in the X-rays. As a result, one of the fundamental uncertainties in these spectroscopic measurements arises from the absolute flux calibrations of the detectors being used. Using the stable X-ray burster, GS 1826–238, and its simultaneous observations by Chandra HETG/ACIS-S and RXTE /PCA as well as by XMM-Newton EPIC-pn and RXTE /PCA, we quantify the degree of uncertainty in the flux calibration by assessing the differences between the measured fluxes during bursts. We find that the RXTE /PCA and the Chandra gratings measurements agree with each other within their formal uncertainties, increasing our confidence in these flux measurements. In contrast, XMM-Newton EPIC-pn measures 14.0 ± 0.3% less flux than the RXTE /PCA. This is consistent with the previously reported discrepancy with the flux measurements of EPIC-pn, compared with EPIC MOS1, MOS2, and ACIS-S detectors. We also show that any intrinsic time-dependent systematic uncertainty that may exist in the calibration of the satellites has already been implicity taken into account in the neutron star radius measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

IACHEC CROSS-CALIBRATION OF CHANDRA , NuSTAR , SWIFT , SUZAKU , XMM-NEWTON WITH 3C 273 ANDPKS 2155-304

On behalf of the International Astronomical Consortium for High Energy Calibration, we present results from the cross-calibration campaigns in 2012 on 3C 273 and in 2013 on PKS 2155-304 between the then active X-ray observatories Chandra , NuSTAR , Suzaku , Swift, and XMM-Newton . We compare measured fluxes between instrument pairs in two energy bands, 1–5 keV and 3–7 keV, and calculate an average cross-normalization constant for each energy range. We review known cross-calibration features and provide a series of tables and figures to be used for evaluating cross-normalization constants obtained from other observations with the above mentioned observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

Automatic Échelle Spectrograph Wavelength Calibration

Time-domain astronomy and the increasing number of exoplanet candidates call for reliable, robust, and automatic wavelength calibration. We present an algorithm for wavelength-calibrating échelle spectrographs that uses order-by-order extracted spectra and a list of laboratory wavelengths. Our approach is fully automatic and does not need the pixel locations of certain spectral features with which to anchor the wavelength solution, nor the true order number of each diffraction order. We use spectral features that are duplicated in adjacent orders to establish the scale-invariant component of the wavelength solution. We then match the central wavelengths of spectral features to laboratory wavelengths to establish the scale and higher-order components of the wavelength solution. We demonstrate our method on the four spectrographs of Las Cumbres Observatory’s Network of Robotic Échelle Spectrographs (NRES), on the High Accuracy Radial Velocity Planet Searcher (HARPS) spectrograph, and on synthetic data. We obtain a velocity-equivalent precision of ∼10 m s{sup −1} on NRES. We achieve ∼1 m s{sup −1} on HARPS, which agrees with the precision reported by the HARPS team. On synthetic data, we achieve the velocity precision set by Gaussian centroiding errors. Our algorithm likely holds for a wide range of spectrographs beyond the five presented here. We provide an open-source Python package, xwavecal, which outputs wavelength-calibrated spectra as well as the wavelengths of spectral features.

79 ASTRONOMY AND ASTROPHYSICS↗

A D-term Modeling Code (DMC) for Simultaneous Calibration and Full-Stokes Imaging of Very Long Baseline Interferometric Data

In this paper we present DMC, a model and associated tool for polarimetric imaging of very long baseline interferometry data sets that simultaneously reconstructs the full-Stokes emission structure along with the station-based gain and leakage calibration terms. DMC formulates the imaging problem in terms of posterior exploration, which is achieved using Hamiltonian Monte Carlo sampling. The resulting posterior distribution provides a natural quantification of uncertainty in both the image structure and the data calibration. We run DMC on both synthetic and real data sets, the results of which demonstrate its ability to accurately recover both the image structure and calibration quantities, as well as to assess their corresponding uncertainties. The framework underpinning DMC is flexible, and its specific implementation is under continued development.

47 OTHER INSTRUMENTATION↗

Calibration of the Hα Age–Activity Relation for M Dwarfs

In this work, we calibrate the relationship between Hα emission and M dwarf ages. We compile a sample of 892 M dwarfs with Hα equivalent width (Hα EW) measurements from the literature that are either comoving with a white dwarf of known age (21 stars) or in a known young association (871 stars). In this sample we identify 7 M dwarfs that are new candidate members of known associations. By dividing the stars into active and inactive categories according to their Hα EW and spectral type (SpT), we find that the fraction of active dwarfs decreases with increasing age, and the form of the decline depends on SpT. Using the compiled sample of age calibrators, we find that Hα EW and fractional Hα luminosity (L {sub Hα}/L {sub bol}) decrease with increasing age. Hα EW for SpT ≤ M7 decreases gradually up until ∼1 Gyr. For older ages, we found only two early M dwarfs that are both inactive and seem to continue the gradual decrease. We also found 14 mid-type M dwarfs, out of which 11 are inactive and present a significant decrease in Hα EW, suggesting that the magnetic activity decreases rapidly after ∼1 Gyr. We fit L {sub Hα}/L {sub bol} versus age with a broken power law and find an index of −0.11{sub −0.01}{sup +0.02} for ages ≲776 Myr. The index becomes much steeper at older ages, but a lack of field age-calibrators (≫1 Gyr) leaves this part of the relation far less constrained. Finally, from repeated independent measurements for the same stars, we find that 94% of them have a level of Hα EW variability ≤5 Å at young ages (<1 Gyr).

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH-PRECISION ASTROMETRIC MILLIMETER VERY LONG BASELINE INTERFEROMETRY USING A NEW METHOD FOR MULTI-FREQUENCY CALIBRATION

In this paper we describe a new approach for millimeter Very Long Baseline Interferometry (mm-VLBI) calibration that provides bona-fide astrometric alignment of the millimeter-wavelength images from a single source, for the measurement of frequency-dependent effects, such as “core-shifts” near the black hole of active galactic nucleus jets. We achieve our astrometric alignment by solving first for the ionospheric (dispersive) contributions using wide-band centimeter-wavelength observations. Second, we solve for the tropospheric (non-dispersive) contributions by using fast frequency-switching at the target millimeter-wavelengths. These solutions can be scaled and transferred from low frequency to the high frequency. To complete the calibration chain an additional step is required to remove a residual constant phase offset on each antenna. The result is an astrometric calibration and the measurement of the core-shift between 22 and 43 GHz for the jet in BL Lacertae to be −8 ± 5, 20 ± 6 μ as, in R.A. and decl., respectively. By comparison to conventional phase referencing at centimeter-wavelengths we are able to show that this core shift at millimeter-wavelengths is significantly less than what would be predicted by extrapolating the low-frequency result, which closely followed the predictions of the Blandford and Königl conical jet model. As such it would be the first demonstration for the association of the VLBI core with a recollimation shock, normally hidden at low frequencies due to the optical depth, which could be responsible for the γ -ray production in blazar jets.

79 ASTRONOMY AND ASTROPHYSICS↗

LAMOST spectrograph response curves: Stability and application to flux calibration

The task of flux calibration for Large sky Area Multi-Object Spectroscopic Telescope (LAMOST) spectra is difficult due to many factors, such as the lack of standard stars, flat-fielding for large field of view, and variation of reddening between different stars, especially at low Galactic latitudes. Poor selection, bad spectral quality, or extinction uncertainty of standard stars not only might induce errors to the calculated spectral response curve (SRC) but also might lead to failures in producing final 1D spectra. In this paper, we inspected spectra with Galactic latitude |b|⩾60{sup ∘} and reliable stellar parameters, determined through the LAMOST Stellar Parameter Pipeline (LASP), to study the stability of the spectrograph. To guarantee that the selected stars had been observed by each fiber, we selected 37,931 high-quality exposures of 29,000 stars from LAMOST DR2, and more than seven exposures for each fiber. We calculated the SRCs for each fiber for each exposure and calculated the statistics of SRCs for spectrographs with both the fiber variations and time variations. The result shows that the average response curve of each spectrograph (henceforth ASPSRC) is relatively stable, with statistical errors ≤10%. From the comparison between each ASPSRC and the SRCs for the same spectrograph obtained by the 2D pipeline, we find that the ASPSRCs are good enough to use for the calibration. The ASPSRCs have been applied to spectra that were abandoned by the LAMOST 2D pipeline due to the lack of standard stars, increasing the number of LAMOST spectra by 52,181 in DR2. Comparing those same targets with the Sloan Digital Sky Survey (SDSS), the relative flux differences between SDSS spectra and LAMOST spectra with the ASPSRC method are less than 10%, which underlines that the ASPSRC method is feasible for LAMOST flux calibration.

79 ASTRONOMY AND ASTROPHYSICS↗

Using an Absolute Cavity Pyrgeometer to Validate the Calibration of a Secondary Standard Pyrgeometer Outdoors, Independent from the Reference Value of the Atmospheric Longwave Irradiance

Accurate measurements of broadband outdoor longwave irradiance are important for renewable energy applications and the study of the atmosphere and climate change. A unique method of pyrgeometer calibration has been developed to improve the measurement uncertainty [1]. The results of this method yielded irradiance values within ±3 W/m 2 of those traceable to the World InfraRed Standard Group (WISG). This article describes a technique for validating this pyrgeometer calibration method using two Absolute Cavity Pyrgeometers (ACPs). The ACPs and pyrgeometer model PIR were deployed outdoors and the irradiance measured by the PIR was compared against the average irradiance measured by the two ACPs. The irradiance measured by the PIR was calculated using two equations, NREL equation and the Physikalisch Meteorologisches Observatorium Davos (PMOD) equation. The uncertainty with 95% confidence level ( U 95 ) of the irradiance measured by the PIR using NREL equation equaled ±3.51 W/m 2 with respect to SI and using PMOD equation U 95 equaled ±2.99 W/m 2 with respect to SI. These results suggest that the PIR calibration method might be useful in addressing the international need for a secondary standard pyrgeometer traceable to SI.

54 ENVIRONMENTAL SCIENCES↗