Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Beam Optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Determining the oxidation stability of SnSe under atmospheric exposure

Abstract Understanding surface stability becomes critical as 2D materials like SnSe are developed for piezoelectric and optical applications. SnSe thin films deposited by molecular beam epitaxy showed no structural changes after a two-year exposure to atmosphere, as confirmed by X-ray diffraction and Raman spectroscopy. X-ray photoelectron spectroscopy and reflectivity show a stable 3.5 nm surface oxide layer, indicating a self-arresting oxidative process. Resistivity measurements show an electrical response dominated by SnSe post-exposure. This work shows that SnSe films can be used in ambient conditions with minimal risk of long-term degradation, which is critical for the development of piezoelectric or photovoltaic devices. Graphical Abstract

Chin, Jonathan R. (ORCID:0000000273205678)↗

Space Charge Driven Emittance Growth and the Effect of Octupoles in IOTA

The Integrable Optics Test Accelerator (IOTA) at Fermilab is a small machine dedicated to a broad frontier accelerator physics program. An important aspect of this program is to investigate the potential benefits of the resonance free tune spread achievable with integrable optics to store and accelerate high intensity proton beams for which space charge is significant. In this context, a good understanding of proton beam emittance growth and particle loss mechanisms is essential. Assuming nominal design parameters, simulations show that for a bunched beam, the bulk of emittance growth takes place immediately following injection, typically within tens of turns. We attempt to account for this growth using a simplified RMS mismatch theory; some of its limitations and possible improvements are briefly discussed. We then compare theoretical predictions to simulations performed using the PIC code pyORBIT. Further exploring ways to mitigate emittance growth and reduce particle loss, we compare two beam matching strategies: (1) matching at the injection point (2) matching at the center of the nonlinear (octupole) insertion region where $\beta_x = \beta_y$. To observe how nonlinearity affects emittance growth and whether it dominates growth due to mismatch, we track two different distributions. Finally, we explore the potential of using octupoles in a quasi-integrable configuration to mitigate growth using a variety of initial distributions both at reduced and full intensities.

43 PARTICLE ACCELERATORS↗

Quantum Random Walk Simulator Using Ultrafast Optical Switches

Quantum random walk processes have many intriguing applications in high energy physics including the simulation of parton shower evolution. We will present the design and initial results of a fiber loop time-bin quantum walk architecture using the hardware platform already in operation at the Fermilab Quantum Network in which the state of the photon is defined by its time-of-arrival. The fiber loop consists of an unbalanced Mach-Zehnder interferometer implemented using an ultrafast electro-optical switch. The input switch controls the photon path within the interferometer, while the output switch will direct the photon back into the interferometer or to single photon detectors to measure the probability distribution of arrival times. Depending on which path the photon takes each pass through the loop, its wave function will interfere on these optical switches similar to quantum interference on a beam splitter. This work is an important step towards utilizing real-world advantages of quantum information protocols to solve problems in high energy physics.

Cameron, Andrew [Fermilab]↗

Particulate sizes from polarization measurements

Radiation measurements from a ground based polarimeter were used to infer the optical properties of atmospheric particles. The inherent nonunigueness in model calculations is discussed. The inverse problem in atmospheric optics is described, along with incident and emergent beams. Emergent radiation was calculated for all possible particulate distributions, and results were catalogued.

Kuriyan, J. G.↗

Spatially coherent radiation from an array of GaAs lasers

Spatially coherent radiation from a monolithic array of three homostructure GaAs lasers is reported. The three lasers, with their mirror faces antireflection coated, are operated in an external optical cavity built of spherical lenses and plane mirrors. The spatially coherent beam formation makes use of the Fourier transformation property of the internal lenses. The transverse mode control is performed by a spatial filter. The optical peak power at room temperature of the device was measured to be 5 W, three times the power of a single laser in the array. From the synthesized far-field distribution which was evaluated, we conclude that the laser radiation is of spatial coherence.

Philipp-Rutz, E. M.↗

The Choroidal Eye Oximeter - An instrument for measuring oxygen saturation of choroidal blood in vivo

The Choroidal Eye Oximeter is an electro-optical instrument that noninvasively measures the oxygen saturation of choroidal blood in the back of the human eye by a spectrophotometric method. Since choroidal blood is characteristic of blood which is supplied to the brain, the Choroidal Eye Oximeter can be used to monitor the amount of oxygen which is supplied to the brain under varying external conditions. The instrument consists of two basic systems: the optical system and the electronic system. The optical system produces a suitable bi-chromatic beam of light, reflects this beam from the fundus of the subject's eye, and onto a low-noise photodetector. The electronic system amplifies the weak composite signal from the photodetector, computes the average oxygen saturation from the area of the fundus that was sampled, and displays the value of the computed oxygen saturation on a panel meter.

Laing, R. A.↗

A chevron beam-splitter interferometer

Fully tilt compensated double-pass chevron beam splitter, that removes channelling effects and permits optical phase tuning, is wavelength independent and allows small errors in alignment that are not tolerated in Michelson, Machzender, or Sagnac interferometers. Device is very useful in experiments where background vibration affects conventional interferometers.

Breckinridge, J. B.↗

System and method for obtaining wide screen Schlieren photographs

A system for use in Schlieren photography includes (1) a viewing screen adjacently related to a large grating; (2) a small grating disposed in spaced relation with the large grating; (3) a transparent retainer for confining a transparent medium between the gratings; and (4) optics for imaging the small grating on the large grating. A light source and optically aligned lens are used to project a beam of light along axes extending through the small grating and strike the large grating, subsequent to passing through the medium. A Schlieren image of striations resulting from distortions of light rays proposed by the medium are formed on the screen. A camera is used to photograph the Schlieren image projected on the large screen.

Parthasarathy, S. P.↗

Fuel spray data with LDV

Droplet size and two component velocities in the severe environment of an operating gas turbine combustor system can be measured simultaneously using the solar laser morphokinetomer (SLM) which incorporates the following capabilities: (1) measurement of a true two-dimensional velocity vector with a range of + or - (0.01-200 m/sec); (2) measurement of particle size (range 5 to 300 micron m) simultaneously with the measurement of velocity; (3) specification of probe volume position coordinates with a high degree of accuracy (+ or - 0.5 mm); (4) immediate on-line data checks; and (5) rapid computer storage of acquired data. The optical system of the SLM incorporates an ultrasonic beam splitter to allow the measurement of a two-dimensional velocity vector simultaneously with particle size. A microprocessor with a limited storage capability permits immediate analysis of test data in the test cell.

Rohy, D. A.↗

Laser beam manifold and particle photography system for use in fluid velocity measurements

A laser beam manifold and particle photography system has been developed for use in fluid velocity measurements. The laser manifold is a device which transforms a single laser beam into several uniform parallel beams. By orienting two manifolds mutually perpendicular, an optical grid can be formed which acts as a reference for fluid velocity measurements. This optical grid is for all practical purposes totally nonperturbing to the flow. Tracer particles moving in the plane of the grid are then photographed to yield fluid velocities that can be measured relative to the optical grid. System construction and theory are presented.

Owen, R. B.↗

Multiprism collimator

A special purpose optical collimator system which generates multiple collimated light beams with precisely related angular separation of the beams, is comprised of a stack of relatively flat plate-like refracted prisms in the form of wedges. Each prism has a specified angular deviation, mounted on top of one another in a fixture which holds the wedges so that they are adapted to operate at minimum angular deviation and thus are relatively insensitive to rotational and angular charges. A collimated sources of monochromatic light, generated for example by a helium-neon laser and a collimated beam expander, provides a common incident beam to the wedges whereupon a number equally spaced emergent beams are provided.

Minott, P. O.↗

Cooled grating array spectrometer for 0.6-5 microns

A grating spectrometer, designed to illuminate an array of 122 InSb photodiodes with minimum aberrations and maximum speed, has been constructed. The instrument will be used on the 5 meter Hale telescope at Palomar Observatory, and is easily adaptable to telescopes of various focal ratios. A resolving power of 100-1000 can be obtained at wavelengths between 0.6 microns and 5 microns with remotely interchangeable gratings. The spectrometer is sufficiently compact to fit on the 8-inch work surface of a commercially available dewar, and uses simple on-axis spherical and paraboloidal optical elements. The camera mirror produces an f/2.5 beam which, with the 0.2 mm detectors, allows a 3-in. focal-plane aperture on the 5 meter telescope. All rays fall within a 100 microns blur circle at all points along the array. Distortions have been corrected with a tilted field flattening lens in front of the detector.

Nordholt, J. E.↗

Semiconductor Laser With Two-Dimensional Beam Steering

Modification of monolithic semiconductor injection laser capable of one-dimensional electronic beam steering enables deflection of beam in second direction. Such laser chip provides beam pointing or raster scanning for applications in optical communications, data processing, image scanning, and optical ranging.

Katz, J.↗

Wide-angle flat field telescope

Described is an unobscured three mirror wide angle telescopic imaging system comprised of an input baffle which provides a 20 deg (Y axis) x 30 deg (X axis) field of view, a primary mirror having a convex spherical surface, a secondary mirror having a concave ellipsoidal reflecting surface, a tertiary mirror having a concave spherical reflecting surface. The mirrors comprise mirror elements which are offset segments of parent mirrors whose axes and vertices commonly lie on the system's optical axis. An iris diaphragm forming an aperture stop is located between the secondary and tertiary mirror with its center also being coincident with the optical axis and being further located at the beam waist of input light beams reflected from the primary and secondary mirror surfaces. At the system focus following the tertiary mirror is located a flat detector which may be, for example, a TV imaging tube or a photographic film. When desirable, a spectral transmission filter is placed in front of the detector in close proximity thereto.

Hallam, K. L.↗

Phase Length Optical Phase-Locked-Loop Sensor

The invention is a device that provides a high resolution measurement of the change in optical phase length from the device optical system source to an optical reflector. The invention consists of a optical phase locked loop that uses a laser beam as a carrier of an intensity modulated energy source. The novelty of the invention appears to lie in the overall combination of elements which provide high resolution without loss of wide dynamic range. The invention does not depend on coherent reflection from a target, and thus can measure targets that do not have special preparation or corner reflectors. The use of carrier modulation achieves high resolution without the problems of high speed pulse duration systems. Thus the invention has the advantages of simplicity, low cost, and small size without sacrificing resolution.

Heyman, Joseph S.↗

Robustness of active modal damping of large flexible structures

The method of active modal damping (AMD) is reviewed, and the pinhole/occulter facility (P/OF) is presented as a design example. This system is a large space system composed of a flexible beam, a gimbal-pointing system, and an optical alignment system mounted in the Shuttle cargo bay and excited by typical Shuttle disturbances. The AMD system performance is compared with that of a series-compensated control system.

Greene, Michael↗