CORC $^{\circledR}$ cable terminations with integrated Hall arrays for quench detection

ReBCO superconducting cables have the potential to enable compact thermonuclear fusion reactors that operate at magnetic fields exceeding 20 T and allow operation at temperatures far exceeding the boiling point of liquid helium, potentially allowing for demountable magnets. Normal zone detection remains a challenge, and while novel quench detection techniques are an active area of research, few are non-invasive, provide real-time quench detection, and have been demonstrated with current ramp rates relevant for fusion reactors. To address this problem, a CORC$^{\circledR}$ cable termination is developed with integrated Hall sensors to monitor current redistribution as a proxy for quench detection. The methodology exploits the current sharing and layered topology in CORC$^{\circledR}$ cables, and allows quench detection using a localized sensor instead of co-wound voltage wires or optical fibers. Furthermore, experiments are presented where current redistribution is measured from induced quenches, and in a 0.2 meter CORC$^{\circledR}$ sample it is found that the Hall sensors detect normal zone transitions with a similar magnitude and temporal resolution as voltage measurements. To emulate the conditions of dynamic poloidal and central solenoidal fields, experiments are repeated with ramp rates up to 10 kA s -1 that demonstrate the potential to detect normal zone development over a range of experimental parameters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Observation of radon mitigation in MicroBooNE by a liquid argon filtration system

We report the MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq 222 Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. In the context of two models for radon mitigation via a liquid argon filtration system, a slowing mechanism and a trapping mechanism, MicroBooNE data supports a radon reduction factor of greater than 97% or 99.999%, respectively. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the 222 Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Liquid Argon Purity Demonstrator

The Liquid Argon Purity Demonstrator was an R&D test stand designed to determine if electron drift lifetimes adequate for large neutrino detectors could be achieved without first evacuating the cryostat. We describe here the cryogenic system, its operations, and the apparatus used to determine the contaminant levels in the argon and to measure the electron drift lifetime. The liquid purity obtained by this system was facilitated by a gaseous argon purge. Additionally, gaseous impurities from the ullage were prevented from entering the liquid at the gas-liquid interface by condensing the gas and filtering the resulting liquid before returning to the cryostat. The measured electron drift lifetime in this test was greater than 6 ms, sustained over several periods of many weeks. Measurements of the temperature profile in the argon, to assess convective flow and boiling, were also made and are compared to simulation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uncertainty analysis of Raman spectra for measuring ortho-parahydrogen compositions

Determining ortho-parahydrogen compositions at cryogenic temperatures is an important quality control for liquid hydrogen custody exchange. High orthohydrogen compositions lead to an exothermic reaction resulting in increased boil off and increased venting losses of liquid hydrogen product by either the supplier or consumer. Traditional methods for measuring ortho-parahydrogen compositions such as hot-wire anemometry, nuclear magnetic resonance, and infrared spectroscopy are typically inconvenient at best. As the number of cryogenic hydrogen systems continue to increase, there is an increased need for flexible, standardized techniques for post processing composition measurements. A Raman spectrometer implemented in the Cryo-Catalysis Hydrogen Experimental Facility (CHEF) has demonstrated incredible flexibility for composition measurements of cryogenic hydrogen flows through a wide range of temperatures and pressures with the Raman probe in-situ at cryogenic temperatures. This article analyzes the uncertainty of Raman spectroscopy data of cryogenic hydrogen equilibrated at temperatures in IONEX catalyst. Spectra from hydrogen catalyzed to the equilibrium ortho-parahydrogen composition are processed and compared to expected statistical distributions for method verification.

08 HYDROGEN↗

A Biomass Pyrolysis Oil as a Novel Insect Growth Regulator Mimic for a Variety of Stored Product Beetles

Abstract As fumigants face increasing regulatory restrictions, resistance, and consumer pushback, it is vital to expand the integrated pest management (IPM) chemical toolkit for stored products. The production of biomass derived insecticides (e.g., bio-oil fraction) from byproducts of biofuel production may be a promising alternative source of chemistries for controlling stored product insects. These potential insecticidal bio-oils were fractionated based on boiling points (ranging from 115 to 230°C in one series and 245–250°C in another). Fractions were analyzed using GC-MS, and were found to be unique in composition. The lethality of these fractions was tested on Tribolium castaneum, Tribolium confusum, and Oryzaephilus surinamensis (L.) (Coleoptera: Silvanidae). Fractions were tested at concentrations ranging from 5–260 mg/ml to screen for efficacy against adults for durations of 2–8 hr sprayed on concrete arenas. In addition, a separate assay evaluated adult emergence of larvae after 6 wk with supplemental food in arenas, while repellency was evaluated against four stored product insect species in a laminar wind tunnel. A greenhouse gas (GHG) emissions life cycle assessment was also performed, which found the use of the bio-oil fraction could reduce GHG emissions associated with the insecticide supply chain by 25–61% relative to a fossil-fuel based insecticide or pyrethroid. While adults were largely unaffected, we found that larval emergence was significantly suppressed compared to controls by roughly half or more. We also determined that there was minimal repellency to most fractions by most species. We conclude that the use of bio-oil fractions is a climate-friendly choice that may support IPM programs.

09 BIOMASS FUELS↗

Kallotenue papyrolyticum gen. nov., sp. nov., a cellulolytic and filamentous thermophile that represents a novel lineage (Kallotenuales ord. nov., Kallotenuaceae fam. nov.) within the class Chloroflexia

Several closely-related, thermophilic, and cellulolytic bacterial strains, designated JKG1T, JKG2, JKG3, JKG4, and JKG5, were isolated from a cellulolytic enrichment (corn stover) incubated in the water column of Great Boiling Spring, NV. Strain JKG1T had cells of a diameter of 0.7 - 0.9 μm and length of ~2.0 μm that formed non-branched multicellular filaments reaching >300 μm. Spores were not formed and dense liquid cultures were red. The temperature range for growth was 45-65 °C, with an optimum of 55 °C. The pH range for growth was 5.6-9.0, with an optimum of 7.5. JKG1T grew as an aerobic heterotroph, utilizing glucose, sucrose, xylose, arabinose, cellobiose, carboxymethylcellulose, filter paper, microcrystalline cellulose, xylan, starch, casamino acids, tryptone, peptone, yeast extract, acetate, citrate, lactate, pyruvate, and glycerol as sole carbon sources, and was not observed to photosynthesize. The cells stained Gram-negative. Phylogenetic analysis using 16S rRNA gene sequences placed the new isolates in the class Chloroflexia, but distant from other cultivated members, with the highest sequence identity of 82.5% to Roseiflexus castenholzii. The major quinone was menaquinone-9; no ubiquinones were detected. The major cellular fatty acids (>5%) were C18:0, anteiso-C17:0, iso-C18:0, and iso-C17:0. C16:0, iso-C16:0, and C17:0. The peptidoglycan amino acids were alanine, ornithine, glutamic acid, serine, and asparagine. Whole-cell sugars included mannose, rhamnose, glucose, galactose, ribose, arabinose, and xylose. Morphological, phylogenetic, and chemotaxonomic results suggest that JKG1T is representative of a new lineage within the class Chloroflexia, which we propose to designate Kallotenue papyrolyticum gen. nov., sp. nov., Kallotenuaceae fam. nov., Kallotenuales ord. nov.

Environmental Molecular Sciences Laboratory↗

Thermoflexus hugenholtzii gen. nov., sp. nov., a thermophilic, microaerophilic, filamentous bacterium representing a novel class in the Chloroflexi, Thermoflexia classis nov., and description of Thermoflexaceae fam. nov. and Thermoflexales ord. nov.

A thermophilic, filamentous, heterotrophic bacterium designated strain JAD2T was isolated from sediment of Great Boiling Spring in Nevada, USA. Cells had an average diameter of 0.3 µm and length of 4.0 µm, and formed filaments typically ranging in length from 20 µm to 200 µm. Filaments were negative for the Gram stain reaction, spores were not formed, and motility was not observed. The optimum temperature for growth was 75 °C with a range from 67.5-75 °C, and the optimum pH for growth was 6.75 with a range from 6.5-7.75. Peptone, tryptone or yeast extract were able to support growth when supplemented with a vitamin solution, but no growth was observed using a variety of defined organic substrates. Strain JAD2T was a facultative microaerophile, with optimal growth at 1% v/v O2 and an upper limit of 8% O2, and anaerobic growth was stimulated by fumarate but inhibited by sulfite and elemental sulfur. The major cellular fatty acids (>5%) were C16:0, C19:0, C18:0, C20:0, and C19:1. The genomic DNA G+C content was 69.3%. Phylogenetic and phylogenomic analyses using 16S rRNA gene sequences and other conserved genes placed JAD2T and other members of the yet-uncultivated GAL35 group within the phylum Chloroflexi, but not within any existing class in this phylum. These results indicate that strain JAD2T is the first cultivated representative of a new lineage within the phylum Chloroflexi, for which we propose the name Thermoflexus hugenholtzii gen. nov., sp. nov., type strain JAD2T, within Thermoflexia classis nov., Thermoflexales ord. nov., and Thermoflexaceae fam. nov.

Chloroflexi↗

Thermocrinis jamiesonii sp. nov., a thiosulfate-oxidizing, autotropic thermophile isolated from a geothermal spring

An obligately thermophilic, chemolithotrophic, microaerophilic bacterium, designated strain GBS1T, was isolated from the water column of Great Boiling Spring, Nevada, USA. Thiosulfate was required for growth. Although capable of autotrophy, growth of GBS1T was enhanced in the presence of acetate, peptone, or Casamino acids. Growth occurred at 70-85 °C with an optimum at 80 °C, at pH 6.5-7.75 with an optimum at pH 7.25, at 0.5-8% oxygen with an optimum at 1-2%, and at ≤200 mM sodium chloride. The doubling time under optimal growth conditions was 1.3 hrs, with a final cell density of 6.2±0.5 x 107 cells/mL. Non-motile, rod-shaped cells 1.4-2.4 x 0.4-0.6 µm occurred singly or in pairs. Major cellular fatty acids (>5% of total) were C20:1ω9c (44.8%), C18:0 (26.0%), C16:0 (9.9%) and C20:0 (5.4%). Phylogenetic analysis of the GBS1T 16S rRNA gene sequence indicated an affiliation with Thermocrinis ruber and other Thermocrinis spp., but comparisons of 16S rRNA gene identity (≤97.10%) and in silico estimated DNA-DNA hybridization values (≤18.4%) with Thermocrinis spp. indicate that his strain is distinct from described species. Based on phenotypic, genotypic, and phylogenetic characteristics, the name Thermocrinis jamiesonii sp. nov. is proposed, with GBS1T (= JCM 19133T = DSM 27162T) as the type strain.

Environmental Molecular Sciences Laboratory↗

Energy Conversion from Heat to Electricity by Highly Reversible Phase-Transforming Ferroelectrics

The search for performant multiferroic materials has attracted general research interest in energy science as they have been increasingly exploited as the conversion media among thermal, electric, magnetic, and mechanical energies by using their temperature-dependent ferroic properties. Here we report a material development strategy that guides us to discover a reversible phase-transforming ferroelectric material exhibiting enduring energy harvesting from small temperature differences. The material satisfies the crystallographic compatibility condition between polar and nonpolar phases, which shows only 2.5°C thermal hysteresis and a high figure of merit. It stably generates 15μA of electricity in consecutive thermodynamic cycles in the absence of any bias fields. We demonstrate our device to consistently generate 6μA/cm 2 current density near 100°C over 540 complete phase transformation cycles without any electric and functional degradation. The energy-conversion device can light up an LED directly without attaching an external power source. Furthermore, this promising material candidate brings the low-grade waste-heat harvesting closer to a practical realization, e.g., small temperature fluctuations around the water boiling point can be considered as a clean energy source.

30 DIRECT ENERGY CONVERSION↗

Transient heat transfer of superfluid He 4 in nonhomogeneous geometries: Second sound, rarefaction, and thermal layer

Transient heat transfer in superfluid 4 He (He II) is a complex process that involves the interplay of the unique counterflow heat-transfer mode, the emission of second-sound waves, and the creation of quantized vortices. Many past researches focused on homogeneous heat transfer of He II in a uniform channel driven by a planar heater. Here, we report our systematic study of He II transient heat transfer in nonhomogeneous geometries that are pertinent to emergent applications. By solving the He II two-fluid equations of motion coupled with Vinen's equation for vortex-line density, we examine and compare the characteristics of transient heat transfer from planar, cylindrical, and spherical heaters in He II. Our results show that as the heater turns on, an outgoing second-sound pulse emerges, within which the vortex-line density grows rapidly. These vortices attenuate the second sound and result in a heated He II layer in front of the heater, i.e., the thermal layer. In the planar case where the vortices are created throughout the space, the second-sound pulse is continuously attenuated, leading to a thick thermal layer that diffusely spreads following the heat pulse. On the contrary, in the cylindrical and the spherical heater cases, vortices are created mainly in a thin thermal layer near the heater surface. As the heat pulse ends, a rarefaction tail develops following the second-sound pulse, in which the temperature drops. This rarefaction tail can promptly suppress the thermal layer and take away the deposited thermal energy. The effects of the heater size, heat flux, pulse duration, and temperature on the thermal-layer dynamics are discussed. We also show how the peak heat flux for the onset of boiling in He II can be studied in our model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Unusual first-order magnetic phase transition and large magnetocaloric effect in Nd 2 In

A large magnetocaloric effect with its maximum near the boiling point of natural gas occurs in a rare-earth intermetallic compound Nd 2 In. While behaviors of physical properties indicate that paramagnetic-ferromagnetic transformation supporting the large magnetocaloric effect is firstorder in nature, temperature dependent crystallographic study reveals no changes in lattice symmetry and lack of discontinuities either in phase volume or lattice parameters. In this work we discuss how the borderline first-order nature of phase transformation in Nd 2 In is markedly different from conventional firstorder magnetic transitions occurring in other members of the family – isostructural Pr 2 In and non-isostructural Eu 2 In.

36 MATERIALS SCIENCE↗

Laser melting modes in metal powder bed fusion additive manufacturing

In laser powder bed fusion additive manufacturing of metals, extreme thermal conditions create many highly dynamic physical phenomena such as vaporization and recoil, Marangoni convection, and protrusion and keyhole instability. Collectively however, the full set of phenomena is too complicated for practical applications and, in reality, the melting modes are used as a guideline for printing. With increasing local material temperature beyond the boiling point, the mode can change from conduction to keyhole. These mode designations ignore laser-matter interaction details but in many cases are adequate to determine the approximate microstructures and hence the properties of the build. To date, no consistent, common, and coherent definitions have been agreed upon because of historic limitations in melt pool and vapor depression morphology measurements. Here, we distinguish process-based definitions of different melting modes from those based on postmortem evidence. The latter are mainly derived from the transverse cross-sections of the fusion zone, whereas the former come directly from time-resolved x-ray imaging of melt pool and vapor depression morphologies. These process-based definitions are more strict and physically sound, and they offer new guidelines for laser additive manufacturing practices and create new research directions. Further, we highlight the significance of the keyhole, which substantially enhances the laser energy absorption by the melt pool. Recent studies strongly suggest that stable-keyhole laser melting enables efficient, sustainable, and robust additive manufacturing. The realization of this scenario demands the development of multiphysics models, signal translations from morphology to other feasible signals, and in-process metrology across platforms and scales.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The rise of neutron cryo-crystallography

The use of boiled-off liquid nitrogen to maintain protein crystals at 100 K during X-ray data collection has become almost universal. Applying this to neutron protein crystallography offers the opportunity to significantly broaden the scope of biochemical problems that can be addressed, although care must be taken in assuming that direct extrapolation to room temperature is always valid. Here, the history to date of neutron protein cryo-crystallography and the particular problems and solutions associated with the mounting and cryocooling of the larger crystals needed for neutron crystallography are reviewed. Finally, the outlook for further cryogenic neutron studies using existing and future neutron instrumentation is discussed.

59 BASIC BIOLOGICAL SCIENCES↗

In-Containment Signal Conditioning and Transmission via Power Lines within High Dose Rate Areas of Nuclear Power Plants

Signal conditioning and transmission for sensor systems and networks within the containment of nuclear power plants (NPPs) still poses a challenge to engineers, particularly in the case of equipment upgrades for existing plants, temporary measurements, decommissioning of plants, but also for new builds. This paper presents an innovative method for efficient and cost-effective instrumentation within high dose rate areas inside the containment. A transmitter-receiver topology is proposed that allows simultaneous, unidirectional point-to-point transmission of multiple sensor signals by superimposing them on existing AC or DC power supply cables using power line communication (PLC) technology. Thereby the need for costly installation of additional cables and containment penetrations is eliminated. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter is designed to operate in harsh environment within the containment during full plant operation. Hardware modularity of the transmitter allows application specific tradeoffs between redundancy and channel bandwidth. At receiver side in non-radiated areas, signals are extracted from the power line, demodulated, and provided either in analog or digital output format. Laboratory qualification tests and field test results within a boiling water reactor (BWR) are validating the proof of concept of the proposed system. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dynamic Power Network State Estimation with Asynchronous Measurements

The operation of distribution networks is becoming increasingly volatile, due to fast variations of renewables and, hence, net-loading conditions. To perform a reliable state estimation under these conditions, this paper considers the case where measurements from meters, phasor measurement units, and distributed energy resources are collected and processed in real time to produce estimates of the state at a fast time scale. Streams of measurements collected in real time and at heterogenous rates render the underlying processing asynchronous, and poses severe strains on workhorse state estimation algorithms. In this work, a real-time state estimation algorithm is proposed, where data are processed on the fly. Starting from a regularized least-squares model, and leveraging appropriate linear models, the proposed scheme boils down to a linear dynamical system where the state is updated based on the previous estimate and on the measurement gathered from a few available sensors. The estimation error is shown to be always bounded under mild condition. Numerical simulations are provided to corroborate the analytical findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dielectric Fluids for the Direct Forced Convection Cooling of Power Electronics

The future of electrification of vehicles and other systems will require the creation of high-power density power electronics with low junction-to-fluid thermal resistance cooling solutions. One way to create this solution is to move high-heat-flux liquid cooling (single- or two-phase) as close to the power electronics components as possible. One novel approach involves submersion in dielectric fluids as the cooling solution. We first provide the range of fluid properties and develop a figure of merit (FOM) to aid in dielectric fluid selection. Next, we perform computational fluid dynamics/heat transfer (CFD/HT) modeling using single-phase cooling (submerged jet impingement on an enhanced surface) to validate the dielectric fluid FOM. Results of the study show that the developed FOM is a good representation of the performance of the fluids when compared to the results of the CFD/HT analysis. Both FOM and the CFD/HT analysis show that based on pure thermohydraulic considerations, several commercially available fluids present higher performance, on the order of 5% of water. Finally, the FOM can be used to quickly assess the thermohydraulic performance of a dielectric fluid, as well as the secondary application-specific properties such as boiling point, saturation pressure, flash point, and global warming potential, thereby allowing for fluid candidates to be readily compared.

computational fluid dynamics↗

Stray-Capacitance As a Simple Tool for Monitoring and Locating Heat Generation Demonstrated in Three Superconducting Magnets

Real-time monitoring of heat loads in cryogenic systems is critical for many applications, particularly high field magnets. In this work, we demonstrated that by monitoring changes in the capacitance of local probes consisting of thin metal strips with a porous glass fiber dielectric, boiling helium from as little as 0.1 J of deposited heat can be located by an analysis of the response speed and amplitude in nearby probes. We further implemented stray-capacitance monitoring of a magnet's metal support structures, a more global probe of the magnet volumes, in three high temperature superconducting Bi-2212 magnet types. Global structural stray-capacitance monitoring was evaluated for a single racetrack coil, a common coil dipole, and a canted cosine theta winding, showing a quench response comparable to voltage signals without inductive effects. The response of the local and global probes was compared in the single racetrack coil with well-known quench properties. Monitoring the cool-down of the common coil dipole demonstrated the added benefit of the global stray-capacitance as a liquid level monitor. This simple method of monitoring the capacitance has proven to be a versatile and robust technique for monitoring and locating heat.

43 PARTICLE ACCELERATORS↗

Rheology of simulated radioactive waste slurry and cold cap during vitrification

During the vitrification of radioactive waste in a Joule-heated melter, aqueous melter feed slurry forms a cold cap, a reacting and melting material, which floats on the surface of the molten glass. The rheological behavior of the feed affects cold cap formation and shape, and is vital for modeling the feed-to-melt conversion process. Here, we used slurry feed simulant and fast-dried slurry solids representing the cold cap to investigate the rheological behavior of the feed as it transforms into glass. Both low-temperature and high-temperature rheometry were performed and a new scheme was applied to estimate the feed viscosity. This study shows that the conversion advances in four sequential stages that form distinct regions in the cold cap: (i) a fast-spreading boiling slurry from which water evaporates, (ii) a porous solid region (viscosity > 10 8 Pa s) containing reacting solids and molten salts, (iii) a plastic region in which glass-forming melt connects the refractory solids (~10 8 to ~10 6 Pa s), and (iv) a viscous foam layer in which the viscosity drops from ~10 5 to ~10 1 Pa s. The implications for the mathematical modeling of the cold cap are discussed.

glass melting↗