Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

SU-E-T-572: Beam Characteristics and Treatment Planning Commissioning for a New Proton Therapy Unit

Purpose: A single-room proton system, the Mevion S250, was introduced into the arena of proton radiotherapy by Mevion Medical Systems. The first unit was installed and operates at the S. Lee Kling Proton Therapy Center at Barnes-Jewish Hospital. The objective of this abstract is to report the system's beam characteristics and Eclipse commissioning. Methods: Commissioning data were acquired for modelling longitudinal fluence, virtual source position, effective source position, source size and Bragg peaks in Eclipse. Stoichiometric CT calibration was generated via ICRU44 human. Spread-out Bragg peaks (SOBP) were measured with Parallel Plate Chamber and profiles with solid state detector for model validation. Heterogeneity effects were measured with bone and lung inserts in the beam line. RT dose was computed in a virtual water phantom, and exported from Eclipse to compare with measurements at various depths and axis. SOBPs were fine-tuned with partial shining correction and entry correction to match measurements. Output factor was measured for each individual field with an ADCL ion chamber in a water tank and fitted to a polynomial function to cross-check the monitor unit verification. Results: Ranges of all 24 options were measured within ±1mm tolerance. Modulations met a ±1mm or ±2% tolerance. SOBP flatness met a ±3% tolerance. Distal fall off (80%-20%) were measured between 6mm and 7mm for all options. Virtual source positions varied between 177cm and 195cm, decreasing with field size and range. SOBP generated by Eclipse agreed with measurements within ±3% in the entry region, and ±1%/±1mm in other regions. Sanity check for output achieved 5% accuracy in 98% of cases. Conclusion: The commissioning of the first Mevions S250 proton therapy system met specifications. The unit has been put in clinical operation since 12/17/2013.

60 APPLIED LIFE SCIENCES↗

Lattice and grain-boundary diffusions of boron atoms in BaSi{sub 2} epitaxial films on Si(111)

A 180-nm-thick boron (B) layer was deposited on a 300-nm-thick a-axis-oriented BaSi{sub 2} epitaxial film grown by molecular beam epitaxy on Si(111) and was annealed at different temperatures in ultrahigh vacuum. The depth profiles of B were investigated using secondary ion mass spectrometry (SIMS) with O{sup 2+}, and the diffusion coefficients of B were evaluated. The B profiles were reproduced well by taking both the lattice and the grain boundary (GB) diffusions into consideration. The cross-sectional transmission electron microscopy (TEM) image revealed that the GBs of the BaSi{sub 2} film were very sharp and normal to the sample surface. The plan-view TEM image exhibited that the grain size of the BaSi{sub 2} film was approximately 0.6 {mu}m. The temperature dependence of lattice and GB diffusion coefficients was derived from the SIMS profiles, and their activation energies were found to be 4.6 eV and 4.4 eV, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SU-F-T-524: Investigation of the Dosimertric Benefits of Interchangeable Source Size of a Novel Rotating Gamma System

Purpose: Tremendous technological developments were made for conformal therapy techniques with linear accelerators, while less attention was paid to cobalt-60 units. The aim of the current study is to explore the dosimetric benefits of a novel rotating gamma ray system enhanced with interchangeable source sizes and multi-leaf collimator (MLC). Material and Methods: CybeRT is a novel rotating gamma ray machine with a ring gantry that ensures an iso-center accuracy of less than 0.3 mm. The new machine has a 70cm source axial distance allowing for improved penumbra compared to conventional machines. MCBEAM was used to simulate Cobalt-60 beams from the CybeRT head, while the MCPLAN code was used for modeling the MLC and for phantom/patient dose calculation. The CybeRT collimation will incorporate a system allowing for interchanging source sizes. In this work we have created phase space files for 1cm and 2cm source sizes. Evaluation of the system was done by comparing CybeRT beams with the 6MV beams in a water phantom and in patient geometry. Treatment plans were compared based on isodose distributions and dose volume histograms. Results: Profiles for the 1cm source were comparable to that from 6MV in the order of 6mm for 10×10 cm{sup 2} field size at the depth of maximum dose. This could ascribe to Cobalt-60 beams producing lowerenergy secondary electrons. Although, the 2cm source have a larger penumbra however it could be still used for large targets with proportionally increased dose rate. For large lung targets, the difference between cobalt and 6MV plans is clinically insignificant. Our preliminary results showed that interchanging source sizes will allow cobalt beams for volumetric arc therapy of both small lesions and large tumors. Conclusion: The CybeRT system will be a cost effective machine capable of performing advanced radiation therapy treatments of both small tumors and large target volumes.

60 APPLIED LIFE SCIENCES↗

Two-well injector direct-phonon terahertz quantum cascade lasers

We present an experimental study on a terahertz quantum cascade laser (THz QCL) design that combines both two-well injector and direct-phonon scattering schemes, i.e., a so-called two-well injector direct-phonon design. As a result of the two-well injector direct-phonon scheme presented here, the lasers benefit from both a direct phonon scattering scheme for the lower laser level depopulation and a setback for the doping profile that reduces the overlap of the doped region with active laser states. Additionally, our design also has efficient isolation of the active laser levels from excited and continuum states as indicated by negative differential resistance behavior all the way up to room temperature. This scheme serves as a good platform for improving the temperature performance of THz QCLs as indicated by the encouraging temperature performance results of the device with a relatively high doping level of 7.56 × 10 10 cm −2 and T max ∼ 167 K. With the right optimization of the molecular beam epitaxy growth and interface quality, the injection coupling strength, and the doping density and its profile, the device could potentially reach higher temperatures than the latest records reached for the maximum operating temperature (T max ) of THz QCLs.

47 OTHER INSTRUMENTATION↗

Apparent sizes and spectral line profiles for spherical ('three-dimensional') astrophysical masers

Calculations are performed for the frequency-dependent transport of radiation in a uniform spherical maser. Coupling between the intensities at different frequencies is treated. Spherical masers are commonly utilized as idealized geometries in which to assess possible deviations (sometimes, 'three-dimensional effects') from the approximation of a linear geometry. We find that the spectral line profile rebroadens in approximately the same manner as that for a linear maser so that the relationship between the line breadth and the luminosity, beaming angle, and degree of saturation is essentially unchanged. The variation of the apparent size of a spherical maser with frequency is not found to be significant at frequencies within the line profile at which the intensity is appreciable. The 'standard approximation' is adequate for obtaining most of the basic properties of spherical masers that have been examined including the relationship between the pumping (or molecular populations) and the intensity of maser radiation. The improved methods employed here are, however, necessary to obtain variation of the apparent size with frequency in the saturated regime. These conclusions differ from those of previous investigators. The calculations here are more reliable than those of previous investigators because these are self-consistent and avoid certain inaccurate simplifications.

Emmering, Robert T.↗

SU-F-T-142: An Analytical Model to Correct the Aperture Scattered Dose in Clinical Proton Beams

Purpose: Apertures or collimators are used to laterally shape proton beams in double scattering (DS) delivery and to sharpen the penumbra in pencil beam (PB) delivery. However, aperture-scattered dose is not included in the current dose calculations of treatment planning system (TPS). The purpose of this study is to provide a method to correct the aperture-scattered dose based on an analytical model. Methods: A DS beam with a non-divergent aperture was delivered using a single-room proton machine. Dose profiles were measured with an ion-chamber scanning in water and a 2-D ion chamber matrix with solid-water buildup at various depths. The measured doses were considered as the sum of the non-contaminated dose and the aperture-scattered dose. The non-contaminated dose was calculated by TPS and subtracted from the measured dose. Aperture scattered-dose was modeled as a 1D Gaussian distribution. For 2-D fields, to calculate the scatter-dose from all the edges of aperture, a sum of weighted distance was used in the model based on the distance from calculation point to aperture edge. The gamma index was calculated between the measured and calculated dose with and without scatter correction. Results: For a beam with range of 23 cm and aperture size of 20 cm, the contribution of the scatter horn was ∼8% of the total dose at 4 cm depth and diminished to 0 at 15 cm depth. The amplitude of scatter-dose decreased linearly with the depth increase. The 1D gamma index (2%/2 mm) between the calculated and measured profiles increased from 63% to 98% for 4 cm depth and from 83% to 98% at 13 cm depth. The 2D gamma index (2%/2 mm) at 4 cm depth has improved from 78% to 94%. Conclusion: Using the simple analytical method the discrepancy between the measured and calculated dose has significantly improved.

60 APPLIED LIFE SCIENCES↗

Efficient sensitivity analysis of the thermal profile in powder bed fusion of metals using hypercomplex automatic differentiation finite element method

Rapid cyclic temperature fluctuation occurring in powder bed fusion of metals using a laser beam (PBF-LB/M) influences the formation of flaws in printed parts. Consequently, there is a pressing need to enhance the quality of printed parts by developing innovative methodologies that can predict thermal histories and help uncover the intricate relationships between process parameters and thermal profiles. Sensitivity Analysis (SA) emerges as an essential tool for this, offering the potential for process optimization and enhanced quality control. Nonetheless, conventional SA methodologies often incur in excessive computational costs and potential numerical approximation errors. Here, to address this technical challenge, we present a novel method for SA that integrates the HYPercomplex-based Automatic Differentiation (HYPAD) technique with transient thermal simulations conducted via the finite element method (FEM). Leveraging this methodology, we efficiently and accurately perform SA for PBF-LB/M processes in a post-processing step. Compared to traditional methods like Finite Differences (FD), HYPAD-FEM required 96 % less computational time for obtaining sensitivities for 22 process parameters, under a comparative study conducted within the context of the 2018–02 AM benchmark of the National Institute of Standards and Technology. In summary, HYPAD-FEM offers superior efficiency and accuracy in SA over conventional methods, delivering the best sensitivity of a model without the need for step-size selection and problem or parameter-based implementations.

36 MATERIALS SCIENCE↗

On parallel laser beam merger in plasmas

Self-focusing instability is a well-known phenomenon of nonlinear optics, which is of great importance in the field of laser–plasma interactions. Self-focusing instability leads to beam focusing and, consequently, breakup into multiple laser filaments. The majority of applications tend to avoid a laser filamentation regime due to its detrimental role on laser spot profile and peak intensity. In our work, using nonlinear Schrödinger equation solver and particle-in-cell simulations, we address the problem of interaction of multiple parallel beams in plasmas. We consider both non-relativistic and moderately relativistic regimes and demonstrate how the physics of parallel beam interaction transitions from the familiar self- and mutual-focusing instabilities in the non-relativistic regime to a moderately relativistic regime, where an analytical description of filament interaction is not available.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probing nonlinear velocity profiles of shear-thinning, nematic platelet dispersions in Couette flow using x-ray photon correlation spectroscopy

In this study, we report experiments employing x-ray photon correlation spectroscopy (XPCS) to characterize the velocity profiles of complex fluids in Couette flow. The approach involves modeling the XPCS correlation functions obtained with the incident x-ray beam passing tangentially through the Couette cell gap at various distances from the inner wall. We first demonstrate the technique with measurements on a dilute colloidal dispersion in the Newtonian liquid glycerol, where the expected linear velocity profiles are recovered. We then employ the technique to map the shear-rate-dependent velocity profiles of a shear-thinning dispersion of nematically ordered Gibbsite platelets. The nonlinear velocity profiles of the Gibbsite dispersion include a narrow slip region adjacent to the outer wall and a band with a small velocity gradient in the interior of the gap that evolves into a region increasingly resembling plug flow with increasing shear rate. Variations in the velocity profile along the vorticity direction indicate an instability in the interface between this region of small velocity gradient and a region of high velocity gradient near the inner wall. The analysis of the small-angle scattering patterns provides information about the spatial and temporal variations in the nematic order of the Gibbsite dispersion and their coupling to the velocity profile. Additional potential applications of this XPCS-based technique and comparisons with established methods for characterizing velocity profiles are discussed.

42 ENGINEERING↗

Study of Alfven eigenmodes stability in plasma with multiple NBI driven energetic particle species

The aim of this study is to analyze the destabilization of Alfven Eigenmodes (AEs) by multiple energetic particle (EP) species in DIII-D and LHD discharges. In this work, we use the reduced MHD equations to describe the linear evolution of the poloidal flux and the toroidal component of the vorticity in a full 3D system, coupled with equations of density and parallel velocity moments for the energetic particle species, including the effect of the acoustic modes, diamagnetic currents, and helical couplings. Furthermore, we add the Landau damping and resonant destabilization effects using a closure relation. The simulations with multiple neutral beam injector (NBI) lines show three different regimes: the nondamped regime where the multibeam AE growth rate is larger compared to the growth rate of the AEs destabilized by the individual NBI lines, the interaction regime where the multibeam AE growth rate is smaller than the single NBI AEs, and the damped regime where the AEs are suppressed. Operations in the damped regime require EP species with different density profile flatness or gradient locations. In addition, the AE growth rate in the interaction regime is further reduced if the combined NBI lines have similar beam temperatures and the β of the NBI line with a flatter EP density profile increases. Additionally, optimization trends are identified in DIII-D high poloidal β and LHD low density/magnetic field discharges with multiple NBI lines as well as the configuration requirements to operate in the damped and interaction regimes. DIII-D simulations show a decrease in the n = 2 to 6 AE growth rate and n = 1 AE are stabilized in the LHD case. The helical coupling effects in LHD simulations lead to a transition from the interaction to the damped regime of the n = 2, –8, 12 helical family.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technical aspects of real time positron emission tracking for gated radiotherapy

Purpose: Respiratory motion can lead to treatment errors in the delivery of radiotherapy treatments. Respiratory gating can assist in better conforming the beam delivery to the target volume. We present a study of the technical aspects of a real time positron emission tracking system for potential use in gated radiotherapy. Methods: The tracking system, called PeTrack, uses implanted positron emission markers and position sensitive gamma ray detectors to track breathing motion in real time. PeTrack uses an expectation–maximization algorithm to track the motion of fiducial markers. A normalized least mean squares adaptive filter predicts the location of the markers a short time ahead to account for system response latency. The precision and data collection efficiency of a prototype PeTrack system were measured under conditions simulating gated radiotherapy. The lung insert of a thorax phantom was translated in the inferior–superior direction with regular sinusoidal motion and simulated patient breathing motion (maximum amplitude of motion ±10 mm, period 4 s). The system tracked the motion of a {sup 22}Na fiducial marker (0.34 MBq) embedded in the lung insert every 0.2 s. The position of the was marker was predicted 0.2 s ahead. For sinusoidal motion, the equation used to model the motion was fitted to the data. The precision of the tracking was estimated as the standard deviation of the residuals. Software was also developed to communicate with a Linac and toggle beam delivery. In a separate experiment involving a Linac, 500 monitor units of radiation were delivered to the phantom with a 3 × 3 cm photon beam and with 6 and 10 MV accelerating potential. Radiochromic films were inserted in the phantom to measure spatial dose distribution. In this experiment, the period of motion was set to 60 s to account for beam turn-on latency. The beam was turned off when the marker moved outside of a 5-mm gating window. Results: The precision of the tracking in the IS direction was 0.53 mm for a sinusoidally moving target, with an average count rate ∼250 cps. The average prediction error was 1.1 ± 0.6 mm when the marker moved according to irregular patient breathing motion. Across all beam deliveries during the radiochromic film measurements, the average prediction error was 0.8 ± 0.5 mm. The maximum error was 2.5 mm and the 95th percentile error was 1.5 mm. Clear improvement of the dose distribution was observed between gated and nongated deliveries. The full-width at halfmaximum of the dose profiles of gated deliveries differed by 3 mm or less than the static reference dose distribution. Monitoring of the beam on/off times showed synchronization with the location of the marker within the latency of the system. Conclusions: PeTrack can track the motion of internal fiducial positron emission markers with submillimeter precision. The system can be used to gate the delivery of a Linac beam based on the position of a moving fiducial marker. This highlights the potential of the system for use in respiratory-gated radiotherapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-D-209-02: A Backscatter Point Spread Function for Entrance Skin Dose Determination

Purpose: To determine the distribution of backscattered radiation to the skin resulting from a non-uniform distribution of primary radiation through convolution with a backscatter point spread function (PSF). Methods: A backscatter PSF is determined using Monte Carlo simulation of a 1 mm primary beam incident on a 30 × 30 cm × 20 cm thick PMMA phantom using EGSnrc software. A primary profile is similarly obtained without the phantom and the difference from the total provides the backscatter profile. This scatter PSF characterizes the backscatter spread for a “point” primary interaction and can be convolved with the entrance primary dose distribution to obtain the total entrance skin dose. The backscatter PSF was integrated into the skin dose tracking system (DTS), a graphical utility for displaying the color-coded skin dose distribution on a 3D graphic of the patient during interventional fluoroscopic procedures. The backscatter convolution method was validated for the non-uniform beam resulting from the use of an ROI attenuator. The ROI attenuator is a copper sheet with about 20% primary transmission (0.7 mm thick) containing a circular aperture; this attenuator is placed in the beam to reduce dose in the periphery while maintaining full dose in the region of interest. The DTS calculated primary plus backscatter distribution is compared to that measured with GafChromic film and that calculated using EGSnrc Monte-Carlo software. Results: The PSF convolution method used in the DTS software was able to account for the spread of backscatter from the ROI region to the region under the attenuator. The skin dose distribution determined using DTS with the ROI attenuator was in good agreement with the distributions measured with Gafchromic film and determined by Monte Carlo simulation Conclusion: The PSF convolution technique provides an accurate alternative for entrance skin dose determination with non-uniform primary x-ray beams. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Predictable surface ablation of dielectrics with few-cycle laser pulse even beyond air ionization

We study surface ablation of dielectrics with single-shot few-cycle optical pulse (∼10 fs) in air, at intensities below and above the onset of air ionization. We perform 3D analysis and careful calibration of the fluence distribution at the laser focus, spanning from linear– to nonlinear– focusing regimes, enabling to thoroughly characterize the severe limitation of the fluence delivered onto the sample surface upon increase of incident pulse energy. Despite significant beam reshaping taking place at high fluence, we demonstrate that it is nevertheless possible to confidently predict the resulting crater profiles on fused silica surface, even in the regime of filamentation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Urinary and Rectal Toxicity Profiles After Permanent Iodine-125 Implant Brachytherapy in Japanese Men: Nationwide J-POPS Multi-institutional Prospective Cohort Study

Purpose: To assess, in a nationwide multi-institutional cohort study begun in 2005 and in which 6927 subjects were enrolled by 2010, the urinary and rectal toxicity profiles of subjects who enrolled during the first 2 years, and evaluate the toxicity profiles for permanent seed implantation (PI) and a combination therapy with PI and external beam radiation therapy (EBRT). Methods and Materials: Baseline data for 2339 subjects out of 2354 patients were available for the analyses. Toxicities were evaluated using the National Cancer Institute's Common Terminology Criteria for Adverse Events, and the International Prostate Symptom Scores were recorded prospectively until 36 months after radiation therapy. Results: Grade 2+ acute urinary toxicities developed in 7.36% (172 of 2337) and grade 2+ acute rectal toxicities developed in 1.03% (24 of 2336) of the patients. Grade 2+ late urinary and rectal toxicities developed in 5.75% (133 of 2312) and 1.86% (43 of 2312) of the patients, respectively. A higher incidence of grade 2+ acute urinary toxicity occurred in the PI group than in the EBRT group (8.49% vs 3.66%; P<.01). Acute rectal toxicity outcomes were similar between the treatment groups. The 3-year cumulative incidence rates for grade 2+ late urinary toxicities were 6.04% versus 4.82% for the PI and the EBRT groups, respectively, with no significant differences between the treatment groups. The 3-year cumulative incidence rates for grade 2+ late rectal toxicities were 0.90% versus 5.01% (P<.01) for the PI and the EBRT groups, respectively. The mean of the postimplant International Prostate Symptom Score peaked at 3 months, but it decreased to a range that was within 2 points of the baseline score, which was observed in 1625 subjects (69.47%) at the 1-year follow-up assessment. Conclusions: The acute urinary toxicities observed were acceptable given the frequency and retention, and the late rectal toxicities were more favorable than those of other studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Adsorption of ethane, ethene, and ethyne on reconstructed Fe 3 O 4 (001)

The adsorption of the C2 hydrocarbons including ethane, ethene, and ethyne are studied on magnetite Fe 3 O 4 (001) by a combination of molecular beam dosing, temperature programmed desorption, and X-ray photoelectron spectroscopy. The ethane desorption profile has a single temperature invariant peak at 100 K while ethene and ethyne exhibit additional peaks at ~120 K and ~135 K. An inversion analysis is used to extract coverage dependent desorption energies as well as coverage-averaged prefactors for each molecule. Ethene and ethyne exhibit moderate coverage dependent desorption energies decreasing from ~80 to ~30 kJ/mol at saturation while ethane shows a relatively coverage invariant desorption energy ~28 kJ/mol. The desorption energies of the C2 hydrocarbons increase in order of increasing bond order. This is likely due to the enhanced interaction of the ethene and ethyne p system to the coordinatively unsaturated octahedral Fe sites (Fe oct ) on the ¬oxide surface. The saturation coverages of each C2 hydrocarbon at 82 K were also determined. Furthermore, these match well with the 2-dimensional spacing determined from their liquid densities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification of the acetaldehyde oxide Criegee intermediate reaction network in the ozone-assisted low-temperature oxidation of trans -2-butene

Uni- and bi-molecular reactions involving Criegee intermediates (CIs) have been the focus of many studies due to the role these molecules play in atmospheric chemistry. The reactivity of CIs is known to strongly depend on their structure. The reaction network of the second simplest CI, acetaldehyde oxide (CH 3 CHOO), is investigated in this work in an atmospheric pressure jet-stirred reactor (JSR) during the ozonolysis of trans-2-butene to explore the kinetic pathways relevant to atmospheric chemistry and low-temperature combustion. The mole fraction profiles of reactants, intermediates, and final products are determined by means of molecular-beam mass spectrometry in conjunction with single-photon ionization employing tunable synchrotron-generated vacuum ultraviolet radiation. A network of CI reactions is identified in the temperature region below 600 K, characterized by CI addition to trans-2-butene, water, formaldehyde, formic acid, and methanol. No sequential additions of the CH 3 CHOO CI are observed, in contrast with the reactivity of the simplest CI (H 2 COO) and the earlier observation of an extensive reaction network with up to four H 2 COO sequential additions (Phys. Chem. Chem. Phys., 2019, 21, 7341–7357). Experimental photoionization efficiency scans recorded at 300 K and 425 K and ab initio threshold energy calculations lead to the identification and quantification of previously elusive intermediates, such as ketohydroperoxide and hydroperoxide species. Specifically, the C 4 H 8 + O 3 adduct is identified as a ketohydroperoxide (KHP, 3-hydroperoxybutan-2-one, CH 3 C([double bond, length as m-dash]O)CH(CH 3 )OOH), while hydroxyacetaldehyde (glycolaldehyde, HCOCH 2 OH) formation is attributed to unimolecular isomerization of the CIs. Other hydroperoxide species such as methyl hydroperoxide (CH 3 OOH), ethyl hydroperoxide (C 2 H 5 OOH), butyl hydroperoxide (OOH), hydroperoxyl acetaldehyde (HOOCH 2 CHO), hydroxyethyl hydroperoxide (CH 3 CH(OH)OOH), but-1-enyl-3-hydroperoxide, and 4-hydroxy-3-methylpentan-2-one (HOCH(CH 3 )CH(CH 3 )C([double bond, length as m-dash]O)CH 3 ) are also identified. Detection of additional oxygenated species such as methanol, ethanol, ketene, and aldehydes suggests multiple active oxidation routes. Finally, these results provide additional evidence that CIs are key intermediates of the ozone-unsaturated hydrocarbon reactions providing critical inputs for improved kinetics models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mitigation of hot electrons from laser-plasma instabilities in high-Z, highly ionized plasmas

Intense lasers interacting with under-dense plasma can drive laser-plasma instabilities (LPIs) that generate largeamplitude electron plasma waves (EPWs). Suprathermal or “hot” electrons produced in the EPWs are detrimental to inertial confinement fusion (ICF), by reducing capsule implosion efficiency through preheat, and also present an unwanted source of background on x-ray diagnostics. Mitigation of hot electrons was demonstrated in the past by altering plasma conditions near the quarter-critical density, n c /4, with the interpretation of reduced growth of the twoplasmon decay (TPD) instability. Here, we present measurements of hot electrons generated in laser-irradiated planar foils of material ranging from low- to high-Z, where the fraction of laser energy converted to hot electrons, fhot was reduced by a factor of 10 3 going from CH to Au. This correlates with steepening density gradient length-scales that were also measured. Radiation hydrodynamic simulations produced electron density profiles in reasonable agreement with our measurements. According to the simulations, both multi-beam TPD and stimulated Raman scattering were predicted to be above threshold with linear threshold parameters that decreased with increasing Z due to steepening length-scales, as well as enhanced laser absorption and increased EPW collisional and Landau damping.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron Cyclotron power management for control of Neoclassical Tearing Modes in the ITER baseline scenario

Time-dependent simulations are used to evolve plasma discharges in combination with a Modified Rutherford equation (MRE) for calculation of Neoclassical Tearing Mode (NTM) stability in response to Electron Cyclotron (EC) feedback control in ITER. The main application of this integrated approach is to support the development of control algorithms by analyzing the plasma response with physics-based models and to assess how uncertainties in the detection of the magnetic island and in the EC alignment affect the ability of the ITER EC system to fulfill its purpose. These simulations indicate that it is critical to detect the island as soon as possible, before its size exceeds the EC deposition width, and that maintaining alignment with the rational surface within half of the EC deposition width is needed for stabilization and suppression of the modes, especially in the case of modes with helicity (2,1). A broadening of the deposition profile, for example due to wave scattering by turbulence fluctuations or not well aligned beams, could even be favorable in the case of the (2,1)-NTM, by relaxing an over-focussing of the EC beam and improving the stabilization at the mode onset. Pre-emptive control reduces the power needed for suppression and stabilization in the ITER baseline discharge to a maximum of 5 MW, which should be reserved and available to the Upper Launcher during the entire flattop phase. By assuming continuous triggering of NTMs, with pre-emptive control ITER would be still able to demonstrate a fusion gain of Q=10.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗