Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,621 records · Page 90

Characterization of single crystal chemical vapor deposition diamond detectors for neutron spectrometry

Detectors made from artificial chemical vapor deposition single crystal diamond have shown great potential for fast neutron spectrometry. In this paper, we present the results of measurements made at the Physikalisch-Technische Bundesanstalt accelerator using neutron fields in the energy range from 7 MeV to 16 MeV. This study presents the first results of the characterization of the detector in this energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of secondary electrons suppression on emittance measurement of an intense, low-energy beam

Transversal emittance measurements of intense low-energy beams involve use of collimators. As most of the beam is stopped by a collimator, a question arises whether the special conditions in the vicinity of the collimator influence emittance measurement. In particular, the secondary electrons emitted from the slit surface may affect the measurement of the beam phase distribution. We have observed significant modification in the measured phase space distribution of a 5–6 mA DC proton beam at the Soreq Applied Research Accelerator Facility low-energy transport after application of a weak magnetic field in the plane of the slit collimator. The periphery region of the phase distribution was mostly affected. The overall effect on the emittance value was as large as 20%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Orbiter Motion - Microgravity and pointing

The Orbiter Motion section of the Environet Data Base deals with the acceleration and pointing environment on the Space Shuttle Orbiter. This paper presents a discussion of the contents of this section, how to effectively use the material, and plans for further development and modification of the material. Topics covered in the section include types of disturbance forces, terminology, instrumentation, and sources of motion. The sources of motion are further classified as gravity-gradient, aerodynamic drag, thrusting events, crew motion, and machinery motion. Acceleration levels given are the results of direct measurement and also calculation from known force levels. Where appropriate, power spectral density has been used to evaluate frequency content of the acceleration time history. The pointing accuracy of the Orbiter and instruments carried by the Orbiter for fine pointing is also given.

Schwaniger, Arthur J., Jr.↗

A 140 mA cw deuteron electron cyclotron resonance source for the IFMIF-EVEDA project

In the framework of the IFMIF-EVEDA phase (International Fusion Materials Irradiation Facility--Engineering Validation and Engineering Design Activities), the CEA-Saclay is in charged of the design and realization of the 140 mA cw deuteron source. The IFMIF EVEDA demonstrator will be installed in Japan in the next six years and will have to accelerate the deuteron beam up to 9 MeV. CEA will build the source and the low energy beam line (LEBT) and will test the cw high intensity deuteron production at Saclay. The SILHI source is an electron cyclotron resonance (ECR) source, operating at 2.45 GHz. In 2001, it produced more than 130 mA of deuteron beam in pulsed mode to minimize neutron production. Such a result pushes to develop a new ECR source based on the SILHI design and equipped with a specific extraction system. Several options of the accelerator column will be implemented in order to improve the reliability and the efficiency of the source. The IFMIF source and LEBT design will be reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Proton irradiation at kilowatt-power and neutron production from a free-surface liquid-lithium target

The free-surface Liquid-Lithium Target, recently developed at Soreq Applied Research Accelerator Facility (SARAF), was successfully used with a 1.9 MeV, 1.2 mA (2.3 kW) continuous-wave proton beam. Neutrons (∼2 × 10{sup 10} n/s having a peak energy of ∼27 keV) from the {sup 7}Li(p,n){sup 7}Be reaction were detected with a fission-chamber detector and by gold activation targets positioned in the forward direction. The setup is being used for nuclear astrophysics experiments to study neutron-induced reactions at stellar energies and to demonstrate the feasibility of accelerator-based boron neutron capture therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Practical method using superposition of individual magnetic fields for initial arrangement of undulator magnets

We have developed a practical method for determining an excellent initial arrangement of magnetic arrays for a pure-magnet Halbach-type undulator. In this method, the longitudinal magnetic field distribution of each magnet is measured using a moving Hall probe system along the beam axis with a high positional resolution. The initial arrangement of magnetic arrays is optimized and selected by analyzing the superposition of all distribution data in order to achieve adequate spectral quality for the undulator. We applied this method to two elliptically polarizing undulators (EPUs), called U#16-2 and U#02-2, at the Photon Factory storage ring (PF ring) in the High Energy Accelerator Research Organization (KEK). The measured field distribution of the undulator was demonstrated to be excellent for the initial arrangement of the magnet array, and this method saved a great deal of effort in adjusting the magnetic fields of EPUs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing Fundamental Properties of Space with the Fermilab Holometer

Precision length measurements provide valuable insights about the fundamental properties of space-time. The Holometer is a research program to both experimentally probe signatures of the Planck scale and to extend the accessible frequency range from kHz up to MHz for gravitational wave searches. The instrument consists of separate yet identical 39-meter Michelson interferometers operated at Fermi National Accelerator Laboratory, which can reach length sensitivities better than ${10}^{-20}\mathrm{m/}\sqrt{\mathrm{Hz}}$ within the 1-10 MHz frequency range. Lastly, the Holometer is fully operational with 130 of hours of science quality data obtained during the first observational campaign.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Full-length Quench Antenna for MQXFA Production Series Quadrupole Magnet Testing

The MQXFA production series quadrupoles being built for the Hi-Lumi (HL) LHC upgrade by the US Accelerator Upgrade Project (US-HL-LHC AUP) will have very limited instrumentation for characterizing quench events that occur during magnet training and performance validation testing. In order to understand the origin of the quenches, and whether they have some implication for ongoing magnet fabrication, it was decided to build a full-length Quench Antenna (QA) with axial resolution of 50mm to be employed during cold testing in the anticryostat used for magnetic measurements. The goal is to have fineresolution, full-length coverage detection of quench events axially, as well as to have azimuthal resolution on the order of the cable width (about 1 degree for the cross-section), in a device that can be used both for vertical and horizontal testing. To achieve this, a 5m long QA with 128 channels of high-speed data acquisition has been designed and fabricated. The cylindrical antenna features an array of 12 full-length, dipole- and quadrupole-bucked coils positioned radially in the QA interior for azimuthal localization, and over 100 individual channels of short, high-sensitivity, antennas etched as flexible PCB circuits (which also buck dipole and quadrupole fields) wrapped circumferentially on the cylinder exterior in steps of 50mm along the magnet length for axial detection. This report discusses the design, construction and analysis of the MQXFA QA, and first results from using the antenna during quench testing in the production magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The Vertical, Longitudinal, and Lateral Accelerations Experienced by an S. E. 5a Airplane While Maneuvering

This investigation was carried out by the Langley Field Laboratory of the National Advisory Committee for Aeronautics for the purpose of measuring the accelerations along the three principal axes of an airplane while it was maneuvering. The airplane selected for this purpose was the fairly maneuverable SE-5A and the instruments used were the NACA three component accelerometer and the NACA recording airspeed meter. The results showed that the normal accelerations did not exceed 4.000 G. While the lateral and longitudinal accelerations did not exceed 0.60 G.

Norton, F H↗

Demonstration of the stabilization technique for nonplanar optical resonant cavities utilizing polarization

Based on our previously developed scheme to stabilize nonplanar optical resonant cavities utilizing polarization caused by a geometric phase in electromagnetic waves traveling along a twisted path, we report an application of the technique for a cavity installed in the Accelerator Test Facility, a 1.3-GeV electron beam accelerator at KEK, in which photons are generated by laser-Compton scattering. We successfully achieved a power enhancement of 1200 with 1.4% fluctuation, which means that the optical path length of the cavity has been controlled with a precision of 14 pm under an accelerator environment. In addition, polarization switching utilizing a geometric phase of the nonplanar cavity was demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remote Synchrotron Light Instrumentation Using Optical Fibers

By coupling the emitted synchrotron light into an optical fiber, it is possible to transmit the signal at substantial distances from the light port, without the need to use expensive beamlines. This would be especially beneficial in all those cases when the synchrotron is situated in areas not easily access because of their location, or due to high radiation levels. Furthermore, the fiber output can be easily switched, or even shared, between different diagnostic instruments. We present the latest results on the coupling and dispersion measurements performed at the Advanced Light Source in Berkeley. In several cases, coupling synchrotron light into optical fibers can substantially facilitate the use of beam diagnostic instrumentation that measures longitudinal beam properties by detecting synchrotron radiation. It has been discussed in with some detail, how fiberoptics can bring the light at relatively large distances from the accelerator, where a variety of devices can be used to measure beam properties and parameters. Light carried on a fiber can be easily switched between instruments so that each one of them has 100% of the photons available, rather than just a fraction, when simultaneous measurements are not indispensable. From a more general point of view, once synchrotron light is coupled into the fiber, the vast array of techniques and optoelectronic devices, developed by the telecommunication industry becomes available. In this paper we present the results of our experiments at the Advanced Light Source, where we tried to assess the challenges and limitations of the coupling process and determine what level of efficiency one can typically expect to achieve.

43 PARTICLE ACCELERATORS↗

Radiochromic film imaging spectroscopy of laser-accelerated proton beams

This article reports on an experimental method to fully reconstruct laser-accelerated proton beam parameters called radiochromic film imaging spectroscopy (RIS). RIS allows for the characterization of proton beams concerning real and virtual source size, envelope- and microdivergence, normalized transverse emittance, phase space, and proton spectrum. This technique requires particular targets and a high resolution proton detector. Therefore thin gold foils with a microgrooved rear side were manufactured and characterized. Calibrated GafChromic radiochromic film (RCF) types MD-55, HS, and HD-810 in stack configuration were used as spatial and energy resolved film detectors. The principle of the RCF imaging spectroscopy was demonstrated at four different laser systems. This can be a method to characterize a laser system with respect to its proton-acceleration capability. In addition, an algorithm to calculate the spatial and energy resolved proton distribution has been developed and tested to get a better idea of laser-accelerated proton beams and their energy deposition with respect to further applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Numerical simulation and experimental validation of accelerating voltage formation for a pulsed electron accelerator

This paper describes the development of a computation model of a pulsed voltage generator for a repetitive electron accelerator. The model is based on a principle circuit of the generator, supplemented with the parasitics elements of the construction. Verification of the principle model was achieved by comparison of simulation with experimental results, where reasonable agreement was demonstrated for a wide range of generator load resistance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics for studies of novel laser ion acceleration mechanisms

Diagnostic for investigating and distinguishing different laser ion acceleration mechanisms has been developed and successfully tested. An ion separation wide angle spectrometer can simultaneously investigate three important aspects of the laser plasma interaction: (1) acquire angularly resolved energy spectra for two ion species, (2) obtain ion energy spectra for multiple species, separated according to their charge to mass ratio, along selected axes, and (3) collect laser radiation reflected from and transmitted through the target and propagating in the same direction as the ion beam. Thus, the presented diagnostic constitutes a highly adaptable tool for accurately studying novel acceleration mechanisms in terms of their angular energy distribution, conversion efficiency, and plasma density evolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of C{sup 6+} laser ion source and RFQ linac for carbon ion radiotherapy

A prototype C{sup 6+} injector using a laser ion source has been developed for a compact synchrotron dedicated to carbon ion radiotherapy. The injector consists of a laser ion source and a 4-vane radio-frequency quadrupole (RFQ) linac. Ion beams are extracted from plasma and directly injected into the RFQ. A solenoid guides the low-energy beams into the RFQ. The RFQ is designed to accelerate high-intensity pulsed beams. A structure of monolithic vanes and cavities is adopted to reduce its power consumption. In beam acceleration tests, a solenoidal magnetic field set between the laser ion source and the RFQ helped increase both the peak currents before and after the RFQ by a factor of 4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and Operation of PIP-II Injector Test, SSR1 Cryomodule, 325 MHz Amplifiers

The PIP-II Injector Test (PIP2IT) has successfully accelerated ionized hydrogen up to 17MeV through a superconducting, single spoke resonator (SSR1) cryomodule at Fermi National Accelerator Laboratory (FNAL). Each of the SSR1 cavities is tuned to 325MHz and requires up to 6 kW of RF power to accelerate 2mA of ionized hydrogen at the design gradients. RF power amplifiers, specialized for SRF cavity beam operations, were designed by Bhabha Atomic Research Center (BARC) and constructed in a collaboration between the BARC in Mumbai, India and the Electronics Corporation of India Limited (ECIL) in Hyderabad, India. The RF amplifiers meet the specifications and requirements mutually approved between BARC and FNAL. They operate at 325 MHz with a linear power output of 7 kW in both CW and pulse mode. The amplifiers are compatible with the FNAL accelerator personnel safety system and the cavity protection interlocks. Access to controls and internal diagnostic instrumentation are compatible with EPICS control standards. This paper gives details about RF power amplifier development within the Department of Atomic Energy (DAE), India and the operational details with PIP2IT at FNAL.

43 PARTICLE ACCELERATORS↗

A data acquisition system for longitudinal beam properties in a rapid cycling synchrotron

A longitudinal beam properties, data acquisition system has been commissioned to operate in the Fermilab booster ring. This system captures real time information including beam synchronous phase, bunch length, and coupled bunch instability amplitudes as the beam is accelerated from 400 MeV to 8 GeV in 33 ms. The system uses an off-the-shelf Tektronix oscilloscope running Labview software and a synchronous pulse generator. This paper describes the hardware configuration and the software configuration used to optimize the data processing rate. The Fermilab Booster is currently pushed to its intensity limit due to the high demand from different experiments for protons. This will continue into the era of the intensity frontier. While intensity is the most critical parameter, emittance must be controlled as well. Longitudinal emittance is an important parameter for optimizing the slip stacking process in the Main Injector. Longitudinal instabilities can spoil the emittance, so it is important to monitor bunch lengths and bunch phase oscillations in the Booster. The Booster presents a special challenge when it comes to measuring beam properties. The acceleration ramp is short (33ms), and the RF frequency varies from 38-52.8 MHz. Standard instrumentation like spectrum analyzers and network analyzers cannot effectively measure beam properties, because they cannot track the changing frequencies. Early instrumentation involved a series of tracking oscillators, mixers, and diode detectors that would require vigilant calibration. There was a demand for a more robust means of gathering beam parameters.

43 PARTICLE ACCELERATORS↗